Resumo: In this exploratory research a comparative analysis of the requirements of the ABNT ISO/IEC Guide 58:1993 and of the Final Draft Standard ISO/IEC FDIS 17011:2004, which will replace the Guide, is performed . This analysis also takes into account the requirements of mutual recognition arrangements maintained by regional and international co-operations laboratory accreditation bodies. The present study discusses the critical issues in the changes of the requirements, as well as identifies all the differences between the two documents. The differences identified were used to put together a model for the diagnosis of adequacy of a laboratory accreditation system to the new requirements of the future ISO/IEC 17011. In order to verify the applicability of the proposed model, a case study was performed at the General Coordination for Accreditation (CGCRE) of the National Institute of Metrology, Standardization and Industrial Quality (INMETRO) which allowed for the identification of points for improvement of the proposed model as well as provided information aiming at facilitating the implementation of the ISO/IEC 17011 by CGCRE, when the standards is approved
id UFF-2_d77b86853ce91753382def0639ddd243
oai_identifier_str oai:app.uff.br:1/17486
network_acronym_str UFF-2
network_name_str Repositório Institucional da Universidade Federal Fluminense (RIUFF)
repository_id_str 2120
spelling ANÁLISE COMPARATIVA DOS REQUISITOS DO ABNT ISO/IEC GUIA 58 E DA ISO/IEC 17011: Proposta de ModeloAcreditaçãocredenciamentolaboratórioISO/IEC 17011AccreditationlaboratoryISO/IEC 17011CNPQ::ENGENHARIAS::ENGENHARIA DE PRODUCAOIn this exploratory research a comparative analysis of the requirements of the ABNT ISO/IEC Guide 58:1993 and of the Final Draft Standard ISO/IEC FDIS 17011:2004, which will replace the Guide, is performed . This analysis also takes into account the requirements of mutual recognition arrangements maintained by regional and international co-operations laboratory accreditation bodies. The present study discusses the critical issues in the changes of the requirements, as well as identifies all the differences between the two documents. The differences identified were used to put together a model for the diagnosis of adequacy of a laboratory accreditation system to the new requirements of the future ISO/IEC 17011. In order to verify the applicability of the proposed model, a case study was performed at the General Coordination for Accreditation (CGCRE) of the National Institute of Metrology, Standardization and Industrial Quality (INMETRO) which allowed for the identification of points for improvement of the proposed model as well as provided information aiming at facilitating the implementation of the ISO/IEC 17011 by CGCRE, when the standards is approvedUniversidade Federal FluminenseNesta pesquisa exploratória é realizada uma análise comparativa entre os requisitos do ABNT ISO/IEC Guia 58:1993 e a Minuta Final de Norma ISO/IEC FDIS 17011:2004 que substituirá o Guia. A análise considera ainda os requisitos dos acordos de reconhecimento mútuo mantidos pelas cooperações regionais e internacionais de organismos de credenciamento de laboratórios. No presente estudo são discutidos os pontos críticos das mudanças nos requisitos, além de serem identificadas todas as diferenças entre os dois documentos. As diferenças identificadas foram utilizadas para compor um modelo para diagnóstico da situação de adequação de um sistema de credenciamento de laboratórios aos requisitos novos da futura ISO/IEC 17011. A fim de verificar a aplicabilidade do modelo proposto realizou-se um estudo de caso na Coordenação Geral de Credenciamento (CGCRE) Instituto Nacional de Metrologia, Normalização e Qualidade Industrial (INMETRO) que permitiu identificar pontos de melhoria no modelo proposto, bem como fornecer informações objetivando facilitar a implementação da ISO/IEC 17011 pela CGCRE, quando da sua aprovaçãoPrograma de Pós-graduação em Sistemas de GestãoSegurança do Trabalho, Meio-ambiente, Gestão pela Qualidade TotalCosta, Helder GomesCPF:11133344422http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4782862T9&dataRevisao=nullGutierrez, Ruben HuamanchumoCPF:87745796322http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4706492A8&dataRevisao=nullCampos, Renato deCPF:08895115864Soares, Mauricio Araujo2021-03-10T19:12:02Z2008-10-072021-03-10T19:12:02Z2004-05-25info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttps://app.uff.br/riuff/handle/1/17486porCC-BY-SAinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da Universidade Federal Fluminense (RIUFF)instname:Universidade Federal Fluminense (UFF)instacron:UFF2021-03-10T19:12:02Zoai:app.uff.br:1/17486Repositório InstitucionalPUBhttps://app.uff.br/oai/requestriuff@id.uff.bropendoar:21202021-03-10T19:12:02Repositório Institucional da Universidade Federal Fluminense (RIUFF) - Universidade Federal Fluminense (UFF)false
dc.title.none.fl_str_mv ANÁLISE COMPARATIVA DOS REQUISITOS DO ABNT ISO/IEC GUIA 58 E DA ISO/IEC 17011: Proposta de Modelo
title ANÁLISE COMPARATIVA DOS REQUISITOS DO ABNT ISO/IEC GUIA 58 E DA ISO/IEC 17011: Proposta de Modelo
spellingShingle ANÁLISE COMPARATIVA DOS REQUISITOS DO ABNT ISO/IEC GUIA 58 E DA ISO/IEC 17011: Proposta de Modelo
Soares, Mauricio Araujo
Acreditação
credenciamento
laboratório
ISO/IEC 17011
Accreditation
laboratory
ISO/IEC 17011
CNPQ::ENGENHARIAS::ENGENHARIA DE PRODUCAO
title_short ANÁLISE COMPARATIVA DOS REQUISITOS DO ABNT ISO/IEC GUIA 58 E DA ISO/IEC 17011: Proposta de Modelo
title_full ANÁLISE COMPARATIVA DOS REQUISITOS DO ABNT ISO/IEC GUIA 58 E DA ISO/IEC 17011: Proposta de Modelo
title_fullStr ANÁLISE COMPARATIVA DOS REQUISITOS DO ABNT ISO/IEC GUIA 58 E DA ISO/IEC 17011: Proposta de Modelo
title_full_unstemmed ANÁLISE COMPARATIVA DOS REQUISITOS DO ABNT ISO/IEC GUIA 58 E DA ISO/IEC 17011: Proposta de Modelo
title_sort ANÁLISE COMPARATIVA DOS REQUISITOS DO ABNT ISO/IEC GUIA 58 E DA ISO/IEC 17011: Proposta de Modelo
author Soares, Mauricio Araujo
author_facet Soares, Mauricio Araujo
author_role author
dc.contributor.none.fl_str_mv Costa, Helder Gomes
CPF:11133344422
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4782862T9&dataRevisao=null
Gutierrez, Ruben Huamanchumo
CPF:87745796322
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4706492A8&dataRevisao=null
Campos, Renato de
CPF:08895115864
dc.contributor.author.fl_str_mv Soares, Mauricio Araujo
dc.subject.por.fl_str_mv Acreditação
credenciamento
laboratório
ISO/IEC 17011
Accreditation
laboratory
ISO/IEC 17011
CNPQ::ENGENHARIAS::ENGENHARIA DE PRODUCAO
topic Acreditação
credenciamento
laboratório
ISO/IEC 17011
Accreditation
laboratory
ISO/IEC 17011
CNPQ::ENGENHARIAS::ENGENHARIA DE PRODUCAO
description In this exploratory research a comparative analysis of the requirements of the ABNT ISO/IEC Guide 58:1993 and of the Final Draft Standard ISO/IEC FDIS 17011:2004, which will replace the Guide, is performed . This analysis also takes into account the requirements of mutual recognition arrangements maintained by regional and international co-operations laboratory accreditation bodies. The present study discusses the critical issues in the changes of the requirements, as well as identifies all the differences between the two documents. The differences identified were used to put together a model for the diagnosis of adequacy of a laboratory accreditation system to the new requirements of the future ISO/IEC 17011. In order to verify the applicability of the proposed model, a case study was performed at the General Coordination for Accreditation (CGCRE) of the National Institute of Metrology, Standardization and Industrial Quality (INMETRO) which allowed for the identification of points for improvement of the proposed model as well as provided information aiming at facilitating the implementation of the ISO/IEC 17011 by CGCRE, when the standards is approved
publishDate 2004
dc.date.none.fl_str_mv 2004-05-25
2008-10-07
2021-03-10T19:12:02Z
2021-03-10T19:12:02Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://app.uff.br/riuff/handle/1/17486
url https://app.uff.br/riuff/handle/1/17486
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv CC-BY-SA
info:eu-repo/semantics/openAccess
rights_invalid_str_mv CC-BY-SA
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Programa de Pós-graduação em Sistemas de Gestão
Segurança do Trabalho, Meio-ambiente, Gestão pela Qualidade Total
publisher.none.fl_str_mv Programa de Pós-graduação em Sistemas de Gestão
Segurança do Trabalho, Meio-ambiente, Gestão pela Qualidade Total
dc.source.none.fl_str_mv reponame:Repositório Institucional da Universidade Federal Fluminense (RIUFF)
instname:Universidade Federal Fluminense (UFF)
instacron:UFF
instname_str Universidade Federal Fluminense (UFF)
instacron_str UFF
institution UFF
reponame_str Repositório Institucional da Universidade Federal Fluminense (RIUFF)
collection Repositório Institucional da Universidade Federal Fluminense (RIUFF)
repository.name.fl_str_mv Repositório Institucional da Universidade Federal Fluminense (RIUFF) - Universidade Federal Fluminense (UFF)
repository.mail.fl_str_mv riuff@id.uff.br
_version_ 1802135450669809664