Adverse effects related to the central venous catheterization process at a neonatal and pediatric intensive care unit
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Revista Eletrônica de Enfermagem |
Texto Completo: | https://revistas.ufg.br/fen/article/view/14432 |
Resumo: | This study aimed at identifying the types of central venous catheters (CVC) used in neonatal and pediatric patients, describing the adverse effects related to the process of central venous catheterization at a neonatal and pediatric intensive care unit. It consists of a descriptive prospective cohort study, with longitudinal outlining and quantitative approach. Data were collected in the ICU of Fernandes Figueira Institute (IFF/Fiocruz), from 82 medical records, and 130 processes were analyzed. The types of CVC used were: peripherally inserted central catheter – PICC (45.4%) – central venous catheter by direct puncture – CVCP (29.2%) – venous dissection – VD (14.6%) – umbilical venous catheter – UVC (10.8%). The most frequent mechanical adverse effect was obstruction (47.4%), whereas the most frequent infectious adverse effect was clinical sepsis (41.4%). The reduction of mechanical and infectious complication rates in neonatal and pediatric ICU depends on the interventions, modifications and standardization of healthcare practices, in order to guarantee care quality and safety. Descriptors: Patient Safety; Catheterization, Central Venous; Intensive Care Units; Infant, Newborn; Child. |
id |
UFG-13_549677f9c5d4ab18a8f16a830300d461 |
---|---|
oai_identifier_str |
oai:ojs.revistas.ufg.br:article/14432 |
network_acronym_str |
UFG-13 |
network_name_str |
Revista Eletrônica de Enfermagem |
repository_id_str |
|
spelling |
Adverse effects related to the central venous catheterization process at a neonatal and pediatric intensive care unitEfectos adversos relacionados al proceso del cateterismo venoso central en unidad intensiva neonatal y pediátricaEfeitos adversos relacionados ao processo do cateterismo venoso central em unidade intensiva neonatal e pediátricaPatient SafetyCatheterizationCentral VenousIntensive Care UnitsInfantNewbornChild.Patient SafetyCatheterizationCentral VenousIntensive Care UnitsInfantNewbornChild.Seguridad del PacienteCateterismo Venoso CentralUnidades de Cuidados IntensivosRecién NacidoNiño.Seguridad del PacienteCateterismo Venoso CentralUnidades de Cuidados IntensivosRecién NacidoNiño.Segurança do PacienteCateterismo Venoso CentralUnidades de Terapia IntensivaRecém-NascidoCriança.Segurança do PacienteCateterismo Venoso CentralUnidades de Terapia IntensivaRecém-NascidoCriança.This study aimed at identifying the types of central venous catheters (CVC) used in neonatal and pediatric patients, describing the adverse effects related to the process of central venous catheterization at a neonatal and pediatric intensive care unit. It consists of a descriptive prospective cohort study, with longitudinal outlining and quantitative approach. Data were collected in the ICU of Fernandes Figueira Institute (IFF/Fiocruz), from 82 medical records, and 130 processes were analyzed. The types of CVC used were: peripherally inserted central catheter – PICC (45.4%) – central venous catheter by direct puncture – CVCP (29.2%) – venous dissection – VD (14.6%) – umbilical venous catheter – UVC (10.8%). The most frequent mechanical adverse effect was obstruction (47.4%), whereas the most frequent infectious adverse effect was clinical sepsis (41.4%). The reduction of mechanical and infectious complication rates in neonatal and pediatric ICU depends on the interventions, modifications and standardization of healthcare practices, in order to guarantee care quality and safety. Descriptors: Patient Safety; Catheterization, Central Venous; Intensive Care Units; Infant, Newborn; Child.Se objetivó identificar los tipos de catéteres venosos centrales (CVCs) utilizados en pacientes neonatales y pediátricos; describir los efectos adversos relacionados al proceso del cateterismo venoso central en unidad de terapia intensiva (UTI) neonatal y pediátrica. Investigación descriptiva, de cohorte prospectiva, con delineamiento longitudinal, abordaje cuantitativo. Datos recolectados en las UTIs del Instituto Fernandes Figueira (IFF/Fiocruz), según 82 historias clínicas, analizándose 130 procesos. Los tipos de CVCs utilizados fueron: catéter central de inserción periférica – PICC (45,4%), catéter venoso central por punción directa – CVCP (29,2%), disección venosa – DV (14,6%), catéter venoso umbilical – CVU (10,8%). El efecto adverso mecánico más frecuente fue la obstrucción (47,4%), y el infeccioso fue la sepsis clínica (41,4%). La reducción de las tasas de complicaciones mecánicas e infecciosas en UTI neonatal y pediátrica depende de intervenciones, modificaciones y estandarización de las prácticas asistenciales de salud, para garantizar la calidad y seguridad de la atención. Descriptores: Seguridad del Paciente; Cateterismo Venoso Central; Unidades de Cuidados Intensivos; Recién Nacido; Niño.Este estudo teve como objetivos identificar os tipos de cateteres venosos centrais (CVCs) que são utilizados na clientela neonatal e pediátrica, descrevendo os efeitos adversos relacionados ao processo do cateterismo venoso central em unidade de terapia intensiva (UTI) neonatal e pediátrica. Trata-se de pesquisa descritiva, de coorte prospectiva, com delineamento longitudinal e abordagem quantitativa. Os dados foram coletados nas UTIs do Instituto Fernandes Figueira (IFF/Fiocruz), em 82 prontuários, sendo analisados 130 processos. Os tipos de CVCs utilizados foram: cateter central de inserção periférica – PICC (45,4%) – cateter venoso central por punção direta – CVCP (29,2%) – dissecção venosa – DV (14,6%) – cateter venoso umbilical – CVU (10,8%). O efeito adverso mecânico mais frequente foi a obstrução (47,4%), e o infeccioso foi a sepse clínica (41,4%). A redução das taxas de complicações mecânicas e infecciosas em UTI neonatal e pediátrica depende de intervenções, modificações e padronização das práticas assistenciais de saúde, para garantir qualidade e segurança da assistência. Descritores: Segurança do Paciente; Cateterismo Venoso Central; Unidades de Terapia Intensiva; Recém-Nascido; Criança.Faculdade de Enfermagem da UFG2012-12-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.ufg.br/fen/article/view/1443210.5216/ree.v14i4.14432Revista Eletrônica de Enfermagem; Vol. 14 No. 4 (2012); 883-92Revista Eletrônica de Enfermagem; v. 14 n. 4 (2012); 883-921518-1944reponame:Revista Eletrônica de Enfermageminstname:Universidade Federal de Goiás (UFG)instacron:UFGporhttps://revistas.ufg.br/fen/article/view/14432/13353Gomes, Aline Verônica de OliveiraNascimento, Maria Aparecida de LucaSilva, Leila Rangel daSantana, Keli de Cássia Luiz deinfo:eu-repo/semantics/openAccess2020-08-11T00:30:33Zoai:ojs.revistas.ufg.br:article/14432Revistahttps://revistas.ufg.br/fenPUBhttps://revistas.ufg.br/fen/oairee.fen@ufg.br1518-19441518-1944opendoar:2020-08-11T00:30:33Revista Eletrônica de Enfermagem - Universidade Federal de Goiás (UFG)false |
dc.title.none.fl_str_mv |
Adverse effects related to the central venous catheterization process at a neonatal and pediatric intensive care unit Efectos adversos relacionados al proceso del cateterismo venoso central en unidad intensiva neonatal y pediátrica Efeitos adversos relacionados ao processo do cateterismo venoso central em unidade intensiva neonatal e pediátrica |
title |
Adverse effects related to the central venous catheterization process at a neonatal and pediatric intensive care unit |
spellingShingle |
Adverse effects related to the central venous catheterization process at a neonatal and pediatric intensive care unit Gomes, Aline Verônica de Oliveira Patient Safety Catheterization Central Venous Intensive Care Units Infant Newborn Child. Patient Safety Catheterization Central Venous Intensive Care Units Infant Newborn Child. Seguridad del Paciente Cateterismo Venoso Central Unidades de Cuidados Intensivos Recién Nacido Niño. Seguridad del Paciente Cateterismo Venoso Central Unidades de Cuidados Intensivos Recién Nacido Niño. Segurança do Paciente Cateterismo Venoso Central Unidades de Terapia Intensiva Recém-Nascido Criança. Segurança do Paciente Cateterismo Venoso Central Unidades de Terapia Intensiva Recém-Nascido Criança. |
title_short |
Adverse effects related to the central venous catheterization process at a neonatal and pediatric intensive care unit |
title_full |
Adverse effects related to the central venous catheterization process at a neonatal and pediatric intensive care unit |
title_fullStr |
Adverse effects related to the central venous catheterization process at a neonatal and pediatric intensive care unit |
title_full_unstemmed |
Adverse effects related to the central venous catheterization process at a neonatal and pediatric intensive care unit |
title_sort |
Adverse effects related to the central venous catheterization process at a neonatal and pediatric intensive care unit |
author |
Gomes, Aline Verônica de Oliveira |
author_facet |
Gomes, Aline Verônica de Oliveira Nascimento, Maria Aparecida de Luca Silva, Leila Rangel da Santana, Keli de Cássia Luiz de |
author_role |
author |
author2 |
Nascimento, Maria Aparecida de Luca Silva, Leila Rangel da Santana, Keli de Cássia Luiz de |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Gomes, Aline Verônica de Oliveira Nascimento, Maria Aparecida de Luca Silva, Leila Rangel da Santana, Keli de Cássia Luiz de |
dc.subject.por.fl_str_mv |
Patient Safety Catheterization Central Venous Intensive Care Units Infant Newborn Child. Patient Safety Catheterization Central Venous Intensive Care Units Infant Newborn Child. Seguridad del Paciente Cateterismo Venoso Central Unidades de Cuidados Intensivos Recién Nacido Niño. Seguridad del Paciente Cateterismo Venoso Central Unidades de Cuidados Intensivos Recién Nacido Niño. Segurança do Paciente Cateterismo Venoso Central Unidades de Terapia Intensiva Recém-Nascido Criança. Segurança do Paciente Cateterismo Venoso Central Unidades de Terapia Intensiva Recém-Nascido Criança. |
topic |
Patient Safety Catheterization Central Venous Intensive Care Units Infant Newborn Child. Patient Safety Catheterization Central Venous Intensive Care Units Infant Newborn Child. Seguridad del Paciente Cateterismo Venoso Central Unidades de Cuidados Intensivos Recién Nacido Niño. Seguridad del Paciente Cateterismo Venoso Central Unidades de Cuidados Intensivos Recién Nacido Niño. Segurança do Paciente Cateterismo Venoso Central Unidades de Terapia Intensiva Recém-Nascido Criança. Segurança do Paciente Cateterismo Venoso Central Unidades de Terapia Intensiva Recém-Nascido Criança. |
description |
This study aimed at identifying the types of central venous catheters (CVC) used in neonatal and pediatric patients, describing the adverse effects related to the process of central venous catheterization at a neonatal and pediatric intensive care unit. It consists of a descriptive prospective cohort study, with longitudinal outlining and quantitative approach. Data were collected in the ICU of Fernandes Figueira Institute (IFF/Fiocruz), from 82 medical records, and 130 processes were analyzed. The types of CVC used were: peripherally inserted central catheter – PICC (45.4%) – central venous catheter by direct puncture – CVCP (29.2%) – venous dissection – VD (14.6%) – umbilical venous catheter – UVC (10.8%). The most frequent mechanical adverse effect was obstruction (47.4%), whereas the most frequent infectious adverse effect was clinical sepsis (41.4%). The reduction of mechanical and infectious complication rates in neonatal and pediatric ICU depends on the interventions, modifications and standardization of healthcare practices, in order to guarantee care quality and safety. Descriptors: Patient Safety; Catheterization, Central Venous; Intensive Care Units; Infant, Newborn; Child. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-12-31 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revistas.ufg.br/fen/article/view/14432 10.5216/ree.v14i4.14432 |
url |
https://revistas.ufg.br/fen/article/view/14432 |
identifier_str_mv |
10.5216/ree.v14i4.14432 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://revistas.ufg.br/fen/article/view/14432/13353 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Faculdade de Enfermagem da UFG |
publisher.none.fl_str_mv |
Faculdade de Enfermagem da UFG |
dc.source.none.fl_str_mv |
Revista Eletrônica de Enfermagem; Vol. 14 No. 4 (2012); 883-92 Revista Eletrônica de Enfermagem; v. 14 n. 4 (2012); 883-92 1518-1944 reponame:Revista Eletrônica de Enfermagem instname:Universidade Federal de Goiás (UFG) instacron:UFG |
instname_str |
Universidade Federal de Goiás (UFG) |
instacron_str |
UFG |
institution |
UFG |
reponame_str |
Revista Eletrônica de Enfermagem |
collection |
Revista Eletrônica de Enfermagem |
repository.name.fl_str_mv |
Revista Eletrônica de Enfermagem - Universidade Federal de Goiás (UFG) |
repository.mail.fl_str_mv |
ree.fen@ufg.br |
_version_ |
1797049167798861824 |