Latex pipes: sterility of the subjected to the process of sterilization through vapor in "autoclave"
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Revista Eletrônica de Enfermagem |
Texto Completo: | https://revistas.ufg.br/fen/article/view/46958 |
Resumo: | Among the dentistry and medical articles the tubular dispositive requires special attention to the reprocessing due to lumen cleaning difficulty, and also organic material retention allowing biofilm establishment. The aim of this study was to evaluate the sterility of 30 latex pipes submitted to the sterilization process by vapor in autoclave" in a hospital of Goiania-GO. The latex pipe was cut transversely in 2 pieces of 1cm, one at the extreme(E) and middle (M).They were inoculated in BHI (Brain Heart Infusion) and incubated at 37ºC for 20 days. The samples with positive growth were seeded on sheep blood agar for microbial isolation. The colonies were characterized by morphology and biochemical tests. Microorganisms were detected in 5 latex pipes samples (16.7%), from these, 3 samples (10%) obtained from middle pieces, and 2 from extreme pieces (6.7%). The contaminants were identified as Gram-positive bacilli (BGP), coagulase negative staphylococcus (ECN), and coagulase positive staphylococcus (ECP). Multiple reprocessed of these articles are distinguished what facilitates to consuming, collapse, drying, formation of cracks, and microorganisms retention. According to our results, the latex pipes reprocess using vapor in autoclave might be a risk to the users. |
id |
UFG-13_98af6acb71310c7c774489bbe52551cc |
---|---|
oai_identifier_str |
oai:ojs.revistas.ufg.br:article/46958 |
network_acronym_str |
UFG-13 |
network_name_str |
Revista Eletrônica de Enfermagem |
repository_id_str |
|
spelling |
Latex pipes: sterility of the subjected to the process of sterilization through vapor in "autoclave"Tubos del látex: esterilidad pós-reprocesamento a través del vapor en “autoclave"Tubos de látex: esterilidade pós-reprocessamento em vapor saturado sob pressãoSterilizationQuality ControlCross InfectionCross InfectionQuality ControlSterilizationEsterilizaciónControl de CalidadInfección hospitalariaInfección HospitalariaControl de CalidadEsterilizaciónEsterilizaçãoControle de QualidadeInfecção HospitalarControle de QualidadeInfecção HospitalarEsterilizaçãoAmong the dentistry and medical articles the tubular dispositive requires special attention to the reprocessing due to lumen cleaning difficulty, and also organic material retention allowing biofilm establishment. The aim of this study was to evaluate the sterility of 30 latex pipes submitted to the sterilization process by vapor in autoclave" in a hospital of Goiania-GO. The latex pipe was cut transversely in 2 pieces of 1cm, one at the extreme(E) and middle (M).They were inoculated in BHI (Brain Heart Infusion) and incubated at 37ºC for 20 days. The samples with positive growth were seeded on sheep blood agar for microbial isolation. The colonies were characterized by morphology and biochemical tests. Microorganisms were detected in 5 latex pipes samples (16.7%), from these, 3 samples (10%) obtained from middle pieces, and 2 from extreme pieces (6.7%). The contaminants were identified as Gram-positive bacilli (BGP), coagulase negative staphylococcus (ECN), and coagulase positive staphylococcus (ECP). Multiple reprocessed of these articles are distinguished what facilitates to consuming, collapse, drying, formation of cracks, and microorganisms retention. According to our results, the latex pipes reprocess using vapor in autoclave might be a risk to the users.Entre los articulos odonto – medicos- hospitalares los tubulares merecem atención especial para el re proceso devido a la dificultad de limpieza de sus orifícios, que pueden ocacionar el exceso de materia organica e formación de biofilm. Con el fin de evaluar la esterilidad de los tubos de látex sometido al proceso de esterilización en autoclave de vapor en un hospital en Goiânia-GO fueron analizados, después de reprocesamiento, 30 tubos. Han sido realizados secciones transversales 01 cm en dos segmentos de los tubos: extremidad (E) y medio (M) que fueron inoculados en caldo BHI (Brain Heart Infusion) y incubados a 37 ° C durante 20 días. Muestras con turbidez visibles fueron sembradas en agar sangre de oveja para el aislamiento microbiano. Las colonias desarrolladas se caracterizan por la morfología y pruebas bioquímicas. Hubo un desarrollo microbiano en 05 (16,7%) muestras, de las cuales 03 (10%) en los sectores M y 02 (6,7%) en el E. Los microorganismos contaminantes fueron identificados como bacilos Gram-positivas (BGP), estafilococos coagulasa-negativos y positivos (ECN, ECP). Multiplos reprocesamientos de estos elementos facilita el desgaste, aluimiento, resecamiento, formación de rajaduras, lo que favorece la retención de los microorganismos. De acuerdo a estos resultados, he sido concluido que tubos de látex reprocesados en un autoclave de vapor pueden presentar riesgos para los usuarios.Entre os artigos odonto-médico-hospitalares, os tubulares merecem atenção especial para o reprocessamento pela dificuldade de limpeza de seu lúmen, que pode permitir acúmulo de matéria orgânica e formação de biofilme. Com o objetivo de avaliar a esterilidade dos tubos de látex submetidos ao processo de esterilização em autoclave a vapor em um hospital de Goiânia-GO foram analisados 30 tubos pós-reprocessamento. Realizaram-se cortes transversais de 01 cm em dois segmentos dos tubos: extremidade (E) e metade (M) que foram inoculados em caldo BHI (Brain Heart Infusion) e incubados a 37o C por 20 dias. Amostras com turvação visível foram semeadas em ágar sangue de carneiro para isolamento microbiano. As colônias desenvolvidas foram caracterizadas pela morfologia e por testes bioquímicos. Houve desenvolvimento microbiano em 05 (16,7%) amostras, sendo 03 (10%) segmentos M e 02 (6,7%) seguimentos E. Os microrganismos contaminantes foram identificados como bacilos Gram-positivo (BGP), estafilococos coagulase negativa e positiva (ECN, ECP). Múltiplos reprocessamentos desses artigos facilita o desgaste, colabamento, ressecamento, formação de rachaduras, o que favorece a retenção de microrganismos. De acordo com estes resultados, conclui-se que tubos de látex reprocessados em autoclave a vapor podem representar riscos aos usuários.Faculdade de Enfermagem da UFG2017-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.ufg.br/fen/article/view/4695810.5216/ree.v11.46958Revista Eletrônica de Enfermagem; Vol. 11 No. 2 (2009)Revista Eletrônica de Enfermagem; v. 11 n. 2 (2009)1518-1944reponame:Revista Eletrônica de Enfermageminstname:Universidade Federal de Goiás (UFG)instacron:UFGporhttps://revistas.ufg.br/fen/article/view/46958/23041Copyright (c) 2017 Revista Eletrônica de Enfermageminfo:eu-repo/semantics/openAccessAnders, Patrícia StaciariniTipple, Anaclara Ferreira VeigaCandé, Tcherno AliuBarros, Cynthia Assis deMiranda, Patrícia ValerianaPimenta, Fabiana Cristina2020-08-11T00:28:04Zoai:ojs.revistas.ufg.br:article/46958Revistahttps://revistas.ufg.br/fenPUBhttps://revistas.ufg.br/fen/oairee.fen@ufg.br1518-19441518-1944opendoar:2020-08-11T00:28:04Revista Eletrônica de Enfermagem - Universidade Federal de Goiás (UFG)false |
dc.title.none.fl_str_mv |
Latex pipes: sterility of the subjected to the process of sterilization through vapor in "autoclave" Tubos del látex: esterilidad pós-reprocesamento a través del vapor en “autoclave" Tubos de látex: esterilidade pós-reprocessamento em vapor saturado sob pressão |
title |
Latex pipes: sterility of the subjected to the process of sterilization through vapor in "autoclave" |
spellingShingle |
Latex pipes: sterility of the subjected to the process of sterilization through vapor in "autoclave" Anders, Patrícia Staciarini Sterilization Quality Control Cross Infection Cross Infection Quality Control Sterilization Esterilización Control de Calidad Infección hospitalaria Infección Hospitalaria Control de Calidad Esterilización Esterilização Controle de Qualidade Infecção Hospitalar Controle de Qualidade Infecção Hospitalar Esterilização |
title_short |
Latex pipes: sterility of the subjected to the process of sterilization through vapor in "autoclave" |
title_full |
Latex pipes: sterility of the subjected to the process of sterilization through vapor in "autoclave" |
title_fullStr |
Latex pipes: sterility of the subjected to the process of sterilization through vapor in "autoclave" |
title_full_unstemmed |
Latex pipes: sterility of the subjected to the process of sterilization through vapor in "autoclave" |
title_sort |
Latex pipes: sterility of the subjected to the process of sterilization through vapor in "autoclave" |
author |
Anders, Patrícia Staciarini |
author_facet |
Anders, Patrícia Staciarini Tipple, Anaclara Ferreira Veiga Candé, Tcherno Aliu Barros, Cynthia Assis de Miranda, Patrícia Valeriana Pimenta, Fabiana Cristina |
author_role |
author |
author2 |
Tipple, Anaclara Ferreira Veiga Candé, Tcherno Aliu Barros, Cynthia Assis de Miranda, Patrícia Valeriana Pimenta, Fabiana Cristina |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Anders, Patrícia Staciarini Tipple, Anaclara Ferreira Veiga Candé, Tcherno Aliu Barros, Cynthia Assis de Miranda, Patrícia Valeriana Pimenta, Fabiana Cristina |
dc.subject.por.fl_str_mv |
Sterilization Quality Control Cross Infection Cross Infection Quality Control Sterilization Esterilización Control de Calidad Infección hospitalaria Infección Hospitalaria Control de Calidad Esterilización Esterilização Controle de Qualidade Infecção Hospitalar Controle de Qualidade Infecção Hospitalar Esterilização |
topic |
Sterilization Quality Control Cross Infection Cross Infection Quality Control Sterilization Esterilización Control de Calidad Infección hospitalaria Infección Hospitalaria Control de Calidad Esterilización Esterilização Controle de Qualidade Infecção Hospitalar Controle de Qualidade Infecção Hospitalar Esterilização |
description |
Among the dentistry and medical articles the tubular dispositive requires special attention to the reprocessing due to lumen cleaning difficulty, and also organic material retention allowing biofilm establishment. The aim of this study was to evaluate the sterility of 30 latex pipes submitted to the sterilization process by vapor in autoclave" in a hospital of Goiania-GO. The latex pipe was cut transversely in 2 pieces of 1cm, one at the extreme(E) and middle (M).They were inoculated in BHI (Brain Heart Infusion) and incubated at 37ºC for 20 days. The samples with positive growth were seeded on sheep blood agar for microbial isolation. The colonies were characterized by morphology and biochemical tests. Microorganisms were detected in 5 latex pipes samples (16.7%), from these, 3 samples (10%) obtained from middle pieces, and 2 from extreme pieces (6.7%). The contaminants were identified as Gram-positive bacilli (BGP), coagulase negative staphylococcus (ECN), and coagulase positive staphylococcus (ECP). Multiple reprocessed of these articles are distinguished what facilitates to consuming, collapse, drying, formation of cracks, and microorganisms retention. According to our results, the latex pipes reprocess using vapor in autoclave might be a risk to the users. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revistas.ufg.br/fen/article/view/46958 10.5216/ree.v11.46958 |
url |
https://revistas.ufg.br/fen/article/view/46958 |
identifier_str_mv |
10.5216/ree.v11.46958 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://revistas.ufg.br/fen/article/view/46958/23041 |
dc.rights.driver.fl_str_mv |
Copyright (c) 2017 Revista Eletrônica de Enfermagem info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Copyright (c) 2017 Revista Eletrônica de Enfermagem |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Faculdade de Enfermagem da UFG |
publisher.none.fl_str_mv |
Faculdade de Enfermagem da UFG |
dc.source.none.fl_str_mv |
Revista Eletrônica de Enfermagem; Vol. 11 No. 2 (2009) Revista Eletrônica de Enfermagem; v. 11 n. 2 (2009) 1518-1944 reponame:Revista Eletrônica de Enfermagem instname:Universidade Federal de Goiás (UFG) instacron:UFG |
instname_str |
Universidade Federal de Goiás (UFG) |
instacron_str |
UFG |
institution |
UFG |
reponame_str |
Revista Eletrônica de Enfermagem |
collection |
Revista Eletrônica de Enfermagem |
repository.name.fl_str_mv |
Revista Eletrônica de Enfermagem - Universidade Federal de Goiás (UFG) |
repository.mail.fl_str_mv |
ree.fen@ufg.br |
_version_ |
1797049171051544576 |