Resumo: Objective: To detect the mucous retention cyst of maxillary sinus (MRCMS) through panoramic radiography and cone beam computed tomography (CBCT). Methods: Six thousand panoramic radiographs were selected from digital database for diagnostic analysis of MRCMS. We detected suggestive images of MRCMS in 185 radiographs of patients who were located and invited to return to control. Thirty patients returned for the realization of panoramic radiography for control between 6 and 46 months. Given the presence of MRCMS by radiographic control we performed the CBCT for a better evaluation of the maxillary sinus. Cysts were measured and compared through the images of two methods. The Wilcoxon, Spearman and Kolmorogov-Smirnov tests were used for statistical analysis. The level of significance was set at 5%. Results: There was statistically significant difference between the methods for detection of MRCMS (p <0.05); 23 MRCMS detected by panoramic radiography control were confirmed by CBCT, however, 5 MRCMS detected in CBCT images were not identified by panoramic radiographs. Eight MRCMS detected by X-ray control were not confirmed by CBCT. The discrepancy of extent of MRCMS between images of initial panoramic radiographs and control ones for the CBCT were not statistically significant (p = 0.617 and p = 0.626, respectively) as well as the correlation between time and discrepancy of extent of MRCMS (r = -0.16, p = 0.381). Conclusion: The cone beam computed tomography examination provides more accurate detection of MRCMS than panoramic radiography
id UFG-2_0a6f2f22bd670ef06067120e712b812a
oai_identifier_str oai:repositorio.bc.ufg.br:tde/1524
network_acronym_str UFG-2
network_name_str Repositório Institucional da UFG
repository_id_str
spelling ESTRELA, Carloshttp://lattes.cnpq.br/3611967334176683http://lattes.cnpq.br/9404341324541608RODRIGUES, Cleomar Donizeth2014-07-29T15:25:17Z2012-03-022011-05-31RODRIGUES, Cleomar Donizeth. Three-dimensional Image Contributing to the diagnosis of Mucous Retention cyst in Maxillary Sinus. 2011. 63 f. Tese (Doutorado em Ciencias da Saude) - Universidade Federal de Goiás, Goiânia, 2011.http://repositorio.bc.ufg.br/tede/handle/tde/1524Objective: To detect the mucous retention cyst of maxillary sinus (MRCMS) through panoramic radiography and cone beam computed tomography (CBCT). Methods: Six thousand panoramic radiographs were selected from digital database for diagnostic analysis of MRCMS. We detected suggestive images of MRCMS in 185 radiographs of patients who were located and invited to return to control. Thirty patients returned for the realization of panoramic radiography for control between 6 and 46 months. Given the presence of MRCMS by radiographic control we performed the CBCT for a better evaluation of the maxillary sinus. Cysts were measured and compared through the images of two methods. The Wilcoxon, Spearman and Kolmorogov-Smirnov tests were used for statistical analysis. The level of significance was set at 5%. Results: There was statistically significant difference between the methods for detection of MRCMS (p <0.05); 23 MRCMS detected by panoramic radiography control were confirmed by CBCT, however, 5 MRCMS detected in CBCT images were not identified by panoramic radiographs. Eight MRCMS detected by X-ray control were not confirmed by CBCT. The discrepancy of extent of MRCMS between images of initial panoramic radiographs and control ones for the CBCT were not statistically significant (p = 0.617 and p = 0.626, respectively) as well as the correlation between time and discrepancy of extent of MRCMS (r = -0.16, p = 0.381). Conclusion: The cone beam computed tomography examination provides more accurate detection of MRCMS than panoramic radiographyObjetivos: Detectar o cisto de retenção mucoso do seio maxilar (CRMSM) por meio da radiografia panorâmica e tomografia computadorizada de feixe cônico (TCFC). Metodologia: Seis mil radiografias panorâmicas foram selecionadas do banco digital de dados para análise de diagnóstico de CRMSM. Foram detectadas imagens sugestivas de CRMSM em 185 radiografias, cujos pacientes foram localizados e convidados a retornar para controle. Trinta indivíduos retornaram para a realização de radiografia panorâmica para controle entre 6 e 46 meses. Constatada a presença do CRMSM pelo controle radiográfico realizava-se a TCFC, para uma melhor avaliação do seio maxilar. Cistos foram mensurados e comparados por meio das imagens dos dois métodos. Os testes de Wilcoxon, de Spearman e Kolmorogov-Smirnov foram utilizados para análise estatística. O Nível de significância estabelecido foi de 5%. Resultados: Foi observada diferença estatisticamente significante entre os métodos para detecção dos CRMSM (p<0,05); 23 CRMSM diagnosticados por meio da radiografia panorâmica controle foram confirmados por TCFC, no entanto, 5 CRMSM detectados em TCFC não foram identificados pelas imagens de radiografias panorâmicas. Oito CRMSM detectados pelo controle radiográfico não foram confirmados pela TCFC. A discrepância da extensão do CRMSM entre as imagens das radiografias panorâmicas inicial e controle e da panorâmica controle e TCFC não foram estatisticamente significantes (p=0,617 e p=0,626, respectivamente), bem como a correlação entre tempo e a discrepância da extensão dos CRMSM (r= -0,16 e p= 0,381). Conclusão: O exame por tomografia computadorizada do feixe cônico apresentou maior potencial de detecção de CRMSM que a radiografia panorâmica.Made available in DSpace on 2014-07-29T15:25:17Z (GMT). No. of bitstreams: 1 TESE CLEOMAR D RODRIGUES -Cisto Ret Mucoso Seio Maxilar.pdf: 1752210 bytes, checksum: 164b291567764c89587221e7d462d819 (MD5) Previous issue date: 2011-05-31application/pdfhttp://repositorio.bc.ufg.br/TEDE/retrieve/4376/TESE%20CLEOMAR%20D%20RODRIGUES%20-Cisto%20Ret%20Mucoso%20Seio%20Maxilar.pdf.jpgporUniversidade Federal de GoiásDoutorado em Ciencias da SaudeUFGBRCiencias da Saudecisto mucoso, seios maxilares, radiografia panorâmica, tomografia computadorizada do feixe cônicomucous cyst, maxillary sinus, panoramic radiograph, cone beam computed tomography.CNPQ::CIENCIAS DA SAUDEContribuição da imagem tridimensional para o diagnóstico do cisto de retenção mucoso do seio maxilarThree-dimensional Image Contributing to the diagnosis of Mucous Retention cyst in Maxillary Sinusinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFGinstname:Universidade Federal de Goiás (UFG)instacron:UFGORIGINALTESE CLEOMAR D RODRIGUES -Cisto Ret Mucoso Seio Maxilar.pdfapplication/pdf1752210http://repositorio.bc.ufg.br/tede/bitstreams/1dfb2d94-9a18-478e-b71d-07c5ec479b5d/download164b291567764c89587221e7d462d819MD51THUMBNAILTESE CLEOMAR D RODRIGUES -Cisto Ret Mucoso Seio Maxilar.pdf.jpgTESE CLEOMAR D RODRIGUES -Cisto Ret Mucoso Seio Maxilar.pdf.jpgGenerated Thumbnailimage/jpeg2411http://repositorio.bc.ufg.br/tede/bitstreams/c185c7a6-eaec-41e5-a4f1-5be3483272f6/download03b37b9a983591b9cce1609742864902MD52tde/15242014-07-30 03:13:40.802open.accessoai:repositorio.bc.ufg.br:tde/1524http://repositorio.bc.ufg.br/tedeRepositório InstitucionalPUBhttp://repositorio.bc.ufg.br/oai/requesttasesdissertacoes.bc@ufg.bropendoar:2014-07-30T06:13:40Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)false
dc.title.por.fl_str_mv Contribuição da imagem tridimensional para o diagnóstico do cisto de retenção mucoso do seio maxilar
dc.title.alternative.eng.fl_str_mv Three-dimensional Image Contributing to the diagnosis of Mucous Retention cyst in Maxillary Sinus
title Contribuição da imagem tridimensional para o diagnóstico do cisto de retenção mucoso do seio maxilar
spellingShingle Contribuição da imagem tridimensional para o diagnóstico do cisto de retenção mucoso do seio maxilar
RODRIGUES, Cleomar Donizeth
cisto mucoso, seios maxilares, radiografia panorâmica, tomografia computadorizada do feixe cônico
mucous cyst, maxillary sinus, panoramic radiograph, cone beam computed tomography.
CNPQ::CIENCIAS DA SAUDE
title_short Contribuição da imagem tridimensional para o diagnóstico do cisto de retenção mucoso do seio maxilar
title_full Contribuição da imagem tridimensional para o diagnóstico do cisto de retenção mucoso do seio maxilar
title_fullStr Contribuição da imagem tridimensional para o diagnóstico do cisto de retenção mucoso do seio maxilar
title_full_unstemmed Contribuição da imagem tridimensional para o diagnóstico do cisto de retenção mucoso do seio maxilar
title_sort Contribuição da imagem tridimensional para o diagnóstico do cisto de retenção mucoso do seio maxilar
author RODRIGUES, Cleomar Donizeth
author_facet RODRIGUES, Cleomar Donizeth
author_role author
dc.contributor.advisor1.fl_str_mv ESTRELA, Carlos
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/3611967334176683
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/9404341324541608
dc.contributor.author.fl_str_mv RODRIGUES, Cleomar Donizeth
contributor_str_mv ESTRELA, Carlos
dc.subject.por.fl_str_mv cisto mucoso, seios maxilares, radiografia panorâmica, tomografia computadorizada do feixe cônico
topic cisto mucoso, seios maxilares, radiografia panorâmica, tomografia computadorizada do feixe cônico
mucous cyst, maxillary sinus, panoramic radiograph, cone beam computed tomography.
CNPQ::CIENCIAS DA SAUDE
dc.subject.eng.fl_str_mv mucous cyst, maxillary sinus, panoramic radiograph, cone beam computed tomography.
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS DA SAUDE
description Objective: To detect the mucous retention cyst of maxillary sinus (MRCMS) through panoramic radiography and cone beam computed tomography (CBCT). Methods: Six thousand panoramic radiographs were selected from digital database for diagnostic analysis of MRCMS. We detected suggestive images of MRCMS in 185 radiographs of patients who were located and invited to return to control. Thirty patients returned for the realization of panoramic radiography for control between 6 and 46 months. Given the presence of MRCMS by radiographic control we performed the CBCT for a better evaluation of the maxillary sinus. Cysts were measured and compared through the images of two methods. The Wilcoxon, Spearman and Kolmorogov-Smirnov tests were used for statistical analysis. The level of significance was set at 5%. Results: There was statistically significant difference between the methods for detection of MRCMS (p <0.05); 23 MRCMS detected by panoramic radiography control were confirmed by CBCT, however, 5 MRCMS detected in CBCT images were not identified by panoramic radiographs. Eight MRCMS detected by X-ray control were not confirmed by CBCT. The discrepancy of extent of MRCMS between images of initial panoramic radiographs and control ones for the CBCT were not statistically significant (p = 0.617 and p = 0.626, respectively) as well as the correlation between time and discrepancy of extent of MRCMS (r = -0.16, p = 0.381). Conclusion: The cone beam computed tomography examination provides more accurate detection of MRCMS than panoramic radiography
publishDate 2011
dc.date.issued.fl_str_mv 2011-05-31
dc.date.available.fl_str_mv 2012-03-02
dc.date.accessioned.fl_str_mv 2014-07-29T15:25:17Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv RODRIGUES, Cleomar Donizeth. Three-dimensional Image Contributing to the diagnosis of Mucous Retention cyst in Maxillary Sinus. 2011. 63 f. Tese (Doutorado em Ciencias da Saude) - Universidade Federal de Goiás, Goiânia, 2011.
dc.identifier.uri.fl_str_mv http://repositorio.bc.ufg.br/tede/handle/tde/1524
identifier_str_mv RODRIGUES, Cleomar Donizeth. Three-dimensional Image Contributing to the diagnosis of Mucous Retention cyst in Maxillary Sinus. 2011. 63 f. Tese (Doutorado em Ciencias da Saude) - Universidade Federal de Goiás, Goiânia, 2011.
url http://repositorio.bc.ufg.br/tede/handle/tde/1524
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Goiás
dc.publisher.program.fl_str_mv Doutorado em Ciencias da Saude
dc.publisher.initials.fl_str_mv UFG
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Ciencias da Saude
publisher.none.fl_str_mv Universidade Federal de Goiás
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFG
instname:Universidade Federal de Goiás (UFG)
instacron:UFG
instname_str Universidade Federal de Goiás (UFG)
instacron_str UFG
institution UFG
reponame_str Repositório Institucional da UFG
collection Repositório Institucional da UFG
bitstream.url.fl_str_mv http://repositorio.bc.ufg.br/tede/bitstreams/1dfb2d94-9a18-478e-b71d-07c5ec479b5d/download
http://repositorio.bc.ufg.br/tede/bitstreams/c185c7a6-eaec-41e5-a4f1-5be3483272f6/download
bitstream.checksum.fl_str_mv 164b291567764c89587221e7d462d819
03b37b9a983591b9cce1609742864902
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)
repository.mail.fl_str_mv tasesdissertacoes.bc@ufg.br
_version_ 1798044411022540800