Resumo: To evaluate corneal endothelium by means of specular microscopy exam in patients with keratoconus, before and after Cornealring® corneal intrastromal ring surgery. A hundred and two eyes of sixty-seven patients, aged between 12 and 45, with the average age of 27,31 ± 8,15 years, 30 of whom females and 37 males, were selected to be submitted to the implant of Cornealring® corneal ring segments and evaluation of the corneal endothelium in the pre and post surgery (six months after the procedure) in the External Diseases and Cornea Ward of the Instituto Panamericano da Visão. Data have been stored for later analysis by software SPSS (Statistical Package of Social Science) for Windows 15.0. Only the eyes receiving two rings with 250 μ thickness showed significant statistical difference (p = 0,008). The remaining eyes showed no statistical difference (initial x final). In relation to the thickness and to the number of implanted rings, a decrease in the final coefficient was observed in most implanted rings. However, only the eyes that received two rings 250 μ thick showed significant difference (p=0,003), with a decrease of 10,1% in the coefficients of variation average. In relation to the thickness and number of implanted rings, a decrease in the percentage of hexagonal cells was observed (before and after surgery). Only the eyes that received two rings 250 μ thick showed a highly significant decrease (p=0,001) in relation to the hexagonal percentage of 9,7%. Although the parameters in the specular microscopy showed alterations mainly in the thicker rings, all the patients showed transparent corneas without clinical signs of endothelial suffering along the six months of follow-up. A longer period of study must be considered for better understanding and interpretation of the results obtained, in order to establish any relationship between eventual complications and the thickness of the implanted ring.
id UFG-2_15c95ea7f0caaf016915f7d6c7f01e58
oai_identifier_str oai:repositorio.bc.ufg.br:tde/1546
network_acronym_str UFG-2
network_name_str Repositório Institucional da UFG
repository_id_str
spelling ÁVILA, Marcos Pereira dehttp://lattes.cnpq.br/3335187297522447PEREIRA, Ricardo Antoniohttp://lattes.cnpq.br/6293178284668220http://lattes.cnpq.br/1881369930289164SILVA, Rodrigo Salustiano Corrêa e2014-07-29T15:25:21Z2012-11-302012-06-12SILVA, Rodrigo Salustiano Corrêa e. Corneal endothelial analysis in patients undergoing corneal surgery technique for ring intrastromal. 2012. 73 f. Tese (Doutorado em Ciencias da Saude) - Universidade Federal de Goiás, Goiânia, 2012.http://repositorio.bc.ufg.br/tede/handle/tde/1546ark:/38995/001300000brpvTo evaluate corneal endothelium by means of specular microscopy exam in patients with keratoconus, before and after Cornealring® corneal intrastromal ring surgery. A hundred and two eyes of sixty-seven patients, aged between 12 and 45, with the average age of 27,31 ± 8,15 years, 30 of whom females and 37 males, were selected to be submitted to the implant of Cornealring® corneal ring segments and evaluation of the corneal endothelium in the pre and post surgery (six months after the procedure) in the External Diseases and Cornea Ward of the Instituto Panamericano da Visão. Data have been stored for later analysis by software SPSS (Statistical Package of Social Science) for Windows 15.0. Only the eyes receiving two rings with 250 μ thickness showed significant statistical difference (p = 0,008). The remaining eyes showed no statistical difference (initial x final). In relation to the thickness and to the number of implanted rings, a decrease in the final coefficient was observed in most implanted rings. However, only the eyes that received two rings 250 μ thick showed significant difference (p=0,003), with a decrease of 10,1% in the coefficients of variation average. In relation to the thickness and number of implanted rings, a decrease in the percentage of hexagonal cells was observed (before and after surgery). Only the eyes that received two rings 250 μ thick showed a highly significant decrease (p=0,001) in relation to the hexagonal percentage of 9,7%. Although the parameters in the specular microscopy showed alterations mainly in the thicker rings, all the patients showed transparent corneas without clinical signs of endothelial suffering along the six months of follow-up. A longer period of study must be considered for better understanding and interpretation of the results obtained, in order to establish any relationship between eventual complications and the thickness of the implanted ring.A tese tem por objetivo avaliar o endotélio corneal por meio de microscopia especular, de pacientes portadores de ceratocone, antes e após a cirurgia corneal pela técnica de anel intraestromal, utilizando o implante Cornealring®. Cento e dois olhos de 67 pacientes, com idade entre 12 e 45 anos (com média 27,31 ± 8,15 anos), sendo 30 do sexo feminino e 37 do sexo masculino, foram selecionados para serem submetidos ao implante dos segmentos do anel Cornealring® e avaliação do endotélio corneal no pré e pós-operatório, seis meses após o procedimento, no serviço de Doenças Externas e Córnea do Instituto Panamericano da Visão. Os dados foram armazenados, para posterior análise no software Statistical Package of Social Science (SPSS) para Windows, versão 15.0. Apenas os olhos que receberam dois anéis de espessura de 250 μ apresentaram diferença estatisticamente significativa da densidade endotelial (p = 0,008). Nos demais olhos, não houve diferença estatística (antes e após a cirurgia corneal). Notou-se que, na maioria das espessuras de anéis utilizados, houve uma diminuição do coeficiente de variação após a cirurgia corneal. Porém, só os olhos que receberam dois anéis de espessuras de 250 μ mostraram diferença significativa (p=0,003), com uma diminuição de 10,1% na média do coeficiente de variação. Observou-se diminuição no percentual de células hexagonais em relação, no tocante à espessura e à quantidade de anéis implantados. Somente os olhos que receberam os dois anéis de espessura de 250 μ mostraram diminuição altamente significativa (p=0,001), em relação ao percentual hexagonal de 9,7%. Apesar de os parâmetros na microscopia especular mostrarem-se alterados, sobretudo nos anéis com espessura maior, todos os pacientes apresentaram córneas transparentes sem sinais clínicos de sofrimento endotelial ao longo dos seis meses de seguimento. Maior tempo de estudo deve ser considerado para melhor compreensão e interpretação dos resultados encontrados, a fim de ser estabelecida alguma relação entre possíveis complicações e a espessura do anel implantado.Made available in DSpace on 2014-07-29T15:25:21Z (GMT). No. of bitstreams: 1 tesedefendidarodrigo.pdf: 1424160 bytes, checksum: ba481cb9361d272aa1bf192493e601ce (MD5) Previous issue date: 2012-06-12application/pdfhttp://repositorio.bc.ufg.br/TEDE/retrieve/4139/tesedefendidarodrigo.pdf.jpgporUniversidade Federal de GoiásDoutorado em Ciencias da SaudeUFGBRCiencias da Saudeceratoconeanel intraestromalmicroscopia especularcoeficiente de variaçãopercentual de células hexagonaiskeratoconusintraestromal ringspecular microscopycoefficients of variationpercentage of hexagonal cellsCNPQ::CIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICAAnálise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromalAnálise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromalCorneal endothelial analysis in patients undergoing corneal surgery technique for ring intrastromalCorneal endothelial analysis in patients undergoing corneal surgery technique for ring intrastromalinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFGinstname:Universidade Federal de Goiás (UFG)instacron:UFGORIGINALtesedefendidarodrigo.pdfapplication/pdf1424160http://repositorio.bc.ufg.br/tede/bitstreams/2b6f934a-a0f8-47f4-99f9-79b878b36663/downloadba481cb9361d272aa1bf192493e601ceMD51THUMBNAILtesedefendidarodrigo.pdf.jpgtesedefendidarodrigo.pdf.jpgGenerated Thumbnailimage/jpeg1943http://repositorio.bc.ufg.br/tede/bitstreams/a5b7feaa-d6f2-451a-ad82-b12bcbb88b1b/downloadcc73c4c239a4c332d642ba1e7c7a9fb2MD52tde/15462014-07-30 03:11:40.769open.accessoai:repositorio.bc.ufg.br:tde/1546http://repositorio.bc.ufg.br/tedeRepositório InstitucionalPUBhttp://repositorio.bc.ufg.br/oai/requesttasesdissertacoes.bc@ufg.bropendoar:2014-07-30T06:11:40Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)false
dc.title.por.fl_str_mv Análise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromal
Análise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromal
dc.title.alternative.eng.fl_str_mv Corneal endothelial analysis in patients undergoing corneal surgery technique for ring intrastromal
Corneal endothelial analysis in patients undergoing corneal surgery technique for ring intrastromal
title Análise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromal
spellingShingle Análise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromal
SILVA, Rodrigo Salustiano Corrêa e
ceratocone
anel intraestromal
microscopia especular
coeficiente de variação
percentual de células hexagonais
keratoconus
intraestromal ring
specular microscopy
coefficients of variation
percentage of hexagonal cells
CNPQ::CIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICA
title_short Análise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromal
title_full Análise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromal
title_fullStr Análise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromal
title_full_unstemmed Análise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromal
title_sort Análise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromal
author SILVA, Rodrigo Salustiano Corrêa e
author_facet SILVA, Rodrigo Salustiano Corrêa e
author_role author
dc.contributor.advisor1.fl_str_mv ÁVILA, Marcos Pereira de
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/3335187297522447
dc.contributor.advisor-co1.fl_str_mv PEREIRA, Ricardo Antonio
dc.contributor.advisor-co1Lattes.fl_str_mv http://lattes.cnpq.br/6293178284668220
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/1881369930289164
dc.contributor.author.fl_str_mv SILVA, Rodrigo Salustiano Corrêa e
contributor_str_mv ÁVILA, Marcos Pereira de
PEREIRA, Ricardo Antonio
dc.subject.por.fl_str_mv ceratocone
anel intraestromal
microscopia especular
coeficiente de variação
percentual de células hexagonais
topic ceratocone
anel intraestromal
microscopia especular
coeficiente de variação
percentual de células hexagonais
keratoconus
intraestromal ring
specular microscopy
coefficients of variation
percentage of hexagonal cells
CNPQ::CIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICA
dc.subject.eng.fl_str_mv keratoconus
intraestromal ring
specular microscopy
coefficients of variation
percentage of hexagonal cells
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICA
description To evaluate corneal endothelium by means of specular microscopy exam in patients with keratoconus, before and after Cornealring® corneal intrastromal ring surgery. A hundred and two eyes of sixty-seven patients, aged between 12 and 45, with the average age of 27,31 ± 8,15 years, 30 of whom females and 37 males, were selected to be submitted to the implant of Cornealring® corneal ring segments and evaluation of the corneal endothelium in the pre and post surgery (six months after the procedure) in the External Diseases and Cornea Ward of the Instituto Panamericano da Visão. Data have been stored for later analysis by software SPSS (Statistical Package of Social Science) for Windows 15.0. Only the eyes receiving two rings with 250 μ thickness showed significant statistical difference (p = 0,008). The remaining eyes showed no statistical difference (initial x final). In relation to the thickness and to the number of implanted rings, a decrease in the final coefficient was observed in most implanted rings. However, only the eyes that received two rings 250 μ thick showed significant difference (p=0,003), with a decrease of 10,1% in the coefficients of variation average. In relation to the thickness and number of implanted rings, a decrease in the percentage of hexagonal cells was observed (before and after surgery). Only the eyes that received two rings 250 μ thick showed a highly significant decrease (p=0,001) in relation to the hexagonal percentage of 9,7%. Although the parameters in the specular microscopy showed alterations mainly in the thicker rings, all the patients showed transparent corneas without clinical signs of endothelial suffering along the six months of follow-up. A longer period of study must be considered for better understanding and interpretation of the results obtained, in order to establish any relationship between eventual complications and the thickness of the implanted ring.
publishDate 2012
dc.date.available.fl_str_mv 2012-11-30
dc.date.issued.fl_str_mv 2012-06-12
dc.date.accessioned.fl_str_mv 2014-07-29T15:25:21Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv SILVA, Rodrigo Salustiano Corrêa e. Corneal endothelial analysis in patients undergoing corneal surgery technique for ring intrastromal. 2012. 73 f. Tese (Doutorado em Ciencias da Saude) - Universidade Federal de Goiás, Goiânia, 2012.
dc.identifier.uri.fl_str_mv http://repositorio.bc.ufg.br/tede/handle/tde/1546
dc.identifier.dark.fl_str_mv ark:/38995/001300000brpv
identifier_str_mv SILVA, Rodrigo Salustiano Corrêa e. Corneal endothelial analysis in patients undergoing corneal surgery technique for ring intrastromal. 2012. 73 f. Tese (Doutorado em Ciencias da Saude) - Universidade Federal de Goiás, Goiânia, 2012.
ark:/38995/001300000brpv
url http://repositorio.bc.ufg.br/tede/handle/tde/1546
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Goiás
dc.publisher.program.fl_str_mv Doutorado em Ciencias da Saude
dc.publisher.initials.fl_str_mv UFG
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Ciencias da Saude
publisher.none.fl_str_mv Universidade Federal de Goiás
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFG
instname:Universidade Federal de Goiás (UFG)
instacron:UFG
instname_str Universidade Federal de Goiás (UFG)
instacron_str UFG
institution UFG
reponame_str Repositório Institucional da UFG
collection Repositório Institucional da UFG
bitstream.url.fl_str_mv http://repositorio.bc.ufg.br/tede/bitstreams/2b6f934a-a0f8-47f4-99f9-79b878b36663/download
http://repositorio.bc.ufg.br/tede/bitstreams/a5b7feaa-d6f2-451a-ad82-b12bcbb88b1b/download
bitstream.checksum.fl_str_mv ba481cb9361d272aa1bf192493e601ce
cc73c4c239a4c332d642ba1e7c7a9fb2
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)
repository.mail.fl_str_mv tasesdissertacoes.bc@ufg.br
_version_ 1815172625132945408