Monitoração terapêutica do bussulfano oral, após uso de dose teste e durante condicionamento, em pacientes submetidos a transplante alogênico de células-tronco hematopoiéticas

Detalhes bibliográficos
Autor(a) principal: EFFTING, Cristiane
Data de Publicação: 2012
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFG
dARK ID: ark:/38995/00130000001sw
Texto Completo: http://repositorio.bc.ufg.br/tede/handle/tde/1539
Resumo: Busulfan is an alkylating agent, used for conditioning patients undergoing hematopoietic stem cell transplantation (HSCT). It presents narrow therapeutic range and high variability in pharmacokinetics among patients and doses in the same patient. High plasma concentrations (> 1000 ng mL-1) have been related to toxicity, such as sinusoidal obstruction syndrome, whereas low levels (< 600 ng mL-1) have been associated with primary disease relapse or graft rejection. To avoid problems related to this treatment, therapeutic drug monitoring with dose adjustment has been proposed. Among the methods described, highperformance liquid chromatography (HPLC) is often used. This study aimed at optimizing and validating a technique to dose busulfan by HPLC coupled with photodiode array detector (PDA) and applying it to patientes undergoing HSCT in Goiás. We included eight patients in the group for therapeutic monitoring (MG) and eight in the control group (CG), i.e., with no intervention. Patients in the MG received the test dose (TD) 14 days before the treatment; after determining busulfan pharmacokinetic profile for each patient, the dose was adjusted to the therapeutic objective of 900 ng mL-1. The conditions for chromatography run were: HPLC/PDA, column ACE® C18 (150 mm x 4 mm); mobile phase methanol/water/acetonitrile (65:20:15, v/v/v); eluent flow rate of 1 mL min-1; internal standard 1,6-bis-(methanesulfonyloxy)hexane; UV detection &#955; = 276 nm; derivatization with sodium diethylcarbamate; liquid-liquid extraction with ethyl acetate after precipitation with acetonitrile. We included eight patients in the group for therapeutic monitoring (MG) and eight in the control group (CG). Results obtained: linearity, analyzed through the calibration curve, of 200 5000 ng mL-1; precision, in terms of repeatability (intra-run), of 1.25%-11.25%, and intermediary (inter-run), of 2.17%-10.71%; accuracy of 89.61%-102.18%; recovery of 89%. Half of the patients required dose increase and the mean dose administered was 1.02±0.19 mg kg-1. High variability was observed in assessed pharmacokinetic parameters: 38% variation in Css ____ between TD and conditioning regimen; half-life increased by 11%; ClT/F decreased by 30%, suggesting accumulation of busulfan when the drug is administered in a multiple dose regimen. Although lower than reported in the literature, this variation may be associated with toxicity or failure in treatment, justifying patient monitoring and enhancing validity of previous pharmacokinetic evaluation using TD regimen. Compared to the CG, this variation did not present impact on toxicity, mortality, and survival rates. Other studies with intervention during monitoring and a higher number of patients may present positive impact on the results of HSCT.
id UFG-2_91da4a9aee2e316c9b45f5241407eb9b
oai_identifier_str oai:repositorio.bc.ufg.br:tde/1539
network_acronym_str UFG-2
network_name_str Repositório Institucional da UFG
repository_id_str
spelling CUNHA, Luiz Carlos dahttp://lattes.cnpq.br/6349547031976679ARANTES, Adriano de Moraeshttp://lattes.cnpq.br/2074071976957154http://lattes.cnpq.br/1445169752381815EFFTING, Cristiane2014-07-29T15:25:20Z2012-09-112012-04-13EFFTING, Cristiane. Therapeutic monitoring of oral busulfan, after the use of test dose and during conditioning regimen, in patients undergoing allogeneic hematopoietic stem cell transplantation. 2012. 181 f. Tese (Doutorado em Ciencias da Saude) - Universidade Federal de Goiás, Goiânia, 2012.http://repositorio.bc.ufg.br/tede/handle/tde/1539ark:/38995/00130000001swBusulfan is an alkylating agent, used for conditioning patients undergoing hematopoietic stem cell transplantation (HSCT). It presents narrow therapeutic range and high variability in pharmacokinetics among patients and doses in the same patient. High plasma concentrations (> 1000 ng mL-1) have been related to toxicity, such as sinusoidal obstruction syndrome, whereas low levels (< 600 ng mL-1) have been associated with primary disease relapse or graft rejection. To avoid problems related to this treatment, therapeutic drug monitoring with dose adjustment has been proposed. Among the methods described, highperformance liquid chromatography (HPLC) is often used. This study aimed at optimizing and validating a technique to dose busulfan by HPLC coupled with photodiode array detector (PDA) and applying it to patientes undergoing HSCT in Goiás. We included eight patients in the group for therapeutic monitoring (MG) and eight in the control group (CG), i.e., with no intervention. Patients in the MG received the test dose (TD) 14 days before the treatment; after determining busulfan pharmacokinetic profile for each patient, the dose was adjusted to the therapeutic objective of 900 ng mL-1. The conditions for chromatography run were: HPLC/PDA, column ACE® C18 (150 mm x 4 mm); mobile phase methanol/water/acetonitrile (65:20:15, v/v/v); eluent flow rate of 1 mL min-1; internal standard 1,6-bis-(methanesulfonyloxy)hexane; UV detection &#955; = 276 nm; derivatization with sodium diethylcarbamate; liquid-liquid extraction with ethyl acetate after precipitation with acetonitrile. We included eight patients in the group for therapeutic monitoring (MG) and eight in the control group (CG). Results obtained: linearity, analyzed through the calibration curve, of 200 5000 ng mL-1; precision, in terms of repeatability (intra-run), of 1.25%-11.25%, and intermediary (inter-run), of 2.17%-10.71%; accuracy of 89.61%-102.18%; recovery of 89%. Half of the patients required dose increase and the mean dose administered was 1.02±0.19 mg kg-1. High variability was observed in assessed pharmacokinetic parameters: 38% variation in Css ____ between TD and conditioning regimen; half-life increased by 11%; ClT/F decreased by 30%, suggesting accumulation of busulfan when the drug is administered in a multiple dose regimen. Although lower than reported in the literature, this variation may be associated with toxicity or failure in treatment, justifying patient monitoring and enhancing validity of previous pharmacokinetic evaluation using TD regimen. Compared to the CG, this variation did not present impact on toxicity, mortality, and survival rates. Other studies with intervention during monitoring and a higher number of patients may present positive impact on the results of HSCT.O bussulfano é um agente alquilante utilizado em regimes de condicionamento para ablação medular em pacientes submetidos a transplante de células-tronco hematopoiéticas (TCTH). Apresenta estreita faixa terapêutica e grande variabilidade farmacocinética entre pacientes e entre doses no mesmo paciente. Em altas concentrações plasmáticas (> 1000 ng mL-1), associa-se a toxicidade, como síndrome de obstrução sinusoidal, e em baixas (< 600 ng mL-1), a recaída da doença de base ou rejeição do enxerto. Para evitar problemas relacionados ao tratamento, tem sido proposta sua monitoração terapêutica com ajuste da dose. Entre as metodologias descritas, a cromatografia líquida de alta eficiência (CLAE) é frequentemente utilizada. Este estudo objetivou otimizar e validar técnica de dosagem de bussulfano em CLAE acoplada a detector de arranjo de diodos (DAD) e aplicá-la a pacientes submetidos a TCTH em Goiás. Foram incluídos oito pacientes no grupo para monitoração terapêutica (GM) e oito no grupo controle (GC), ou seja, sem intervenção. Os pacientes do GM receberam a dose teste (DT) 14 dias antes do tratamento; após determinação do perfil farmacocinético do fármaco para cada paciente, a dose foi ajustada para o objetivo terapêutico de 900 ng mL-1. As condições cromatográficas foram: CLAE/DAD, coluna ACE® C18 (150 mm x 4 mm); fase móvel metanol/água/acetonitrila (65:20:15, v/v/v); fluxo de 1 mL min-1; padrão interno 1,6-bis-(metanosulfoniloxi)hexano; detecção UV &#955; = 276 nm; derivatização com dietilditiocarbamato de sódio; extração líquida-líquida com acetato de etila após precipitação com acetonitrila. Os resultados incluíram: linearidade, analisada pela curva de calibração, de 200 5000 ng mL-1; precisão, em termos de repetibilidade (intracorrida), de 1,25%-11,25% e intermediária (intercorrida), de 2,17%-10,71%; exatidão de 89,61%-102,18%; recuperação de 89%. Metade dos pacientes necessitou de aumento da dose e a média da dose administrada foi de 1,02±0,19 mg kg-1. Observou-se alta variabilidade nos parâmetros farmacocinéticos avaliados: variação de 38% da Css ____ entre DT e condicionamento; meia-vida aumentada em 11%; ClT/F reduzido em 30%, sugerindo acúmulo do fármaco quando administrado em esquema de dose múltipla. Embora menor do que a relatada na literatura, essa variação pode estar associada a toxicidade ou falha do tratamento, justificando a monitoração e acentuando a validade da avaliação farmacocinética prévia usando o esquema de DT. Comparada com o GC, essa variação não apresentou impacto sobre toxicidade, mortalidade e sobrevida. Outros trabalhos com intervenções durante a monitoração e maior número de pacientes podem apresentar impacto positivo nos desfechos do TCTH.Made available in DSpace on 2014-07-29T15:25:20Z (GMT). No. of bitstreams: 1 Tese Cristiane Effting - Ciencias Saude.pdf: 411669 bytes, checksum: 16d94233a45ca7b200c1360cdad9a9d4 (MD5) Previous issue date: 2012-04-13application/pdfhttp://repositorio.bc.ufg.br/TEDE/retrieve/4363/Tese%20Cristiane%20Effting%20-%20Ciencias%20Saude.pdf.jpgporUniversidade Federal de GoiásDoutorado em Ciencias da SaudeUFGBRCiencias da SaudeBussulfanoTransplante de células-tronco hematopoiéticasCromatografia líquidaFarmacocinéticaBusulfanLiquid chromatographyHematopoietic stem cell transplantationPharmacokineticsCNPQ::CIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICAMonitoração terapêutica do bussulfano oral, após uso de dose teste e durante condicionamento, em pacientes submetidos a transplante alogênico de células-tronco hematopoiéticasTherapeutic monitoring of oral busulfan, after the use of test dose and during conditioning regimen, in patients undergoing allogeneic hematopoietic stem cell transplantationinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFGinstname:Universidade Federal de Goiás (UFG)instacron:UFGORIGINALTese Cristiane Effting - Ciencias Saude.pdfapplication/pdf411669http://repositorio.bc.ufg.br/tede/bitstreams/f8ece6ca-b7e0-4da8-8c85-25e625bc343c/download16d94233a45ca7b200c1360cdad9a9d4MD51THUMBNAILTese Cristiane Effting - Ciencias Saude.pdf.jpgTese Cristiane Effting - Ciencias Saude.pdf.jpgGenerated Thumbnailimage/jpeg2720http://repositorio.bc.ufg.br/tede/bitstreams/43dba0df-47f0-4221-92c3-a2917d915cde/download415a44f01aa8bc26043b72968a08d872MD52tde/15392014-07-30 03:13:35.261open.accessoai:repositorio.bc.ufg.br:tde/1539http://repositorio.bc.ufg.br/tedeRepositório InstitucionalPUBhttp://repositorio.bc.ufg.br/oai/requesttasesdissertacoes.bc@ufg.bropendoar:2014-07-30T06:13:35Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)false
dc.title.por.fl_str_mv Monitoração terapêutica do bussulfano oral, após uso de dose teste e durante condicionamento, em pacientes submetidos a transplante alogênico de células-tronco hematopoiéticas
dc.title.alternative.eng.fl_str_mv Therapeutic monitoring of oral busulfan, after the use of test dose and during conditioning regimen, in patients undergoing allogeneic hematopoietic stem cell transplantation
title Monitoração terapêutica do bussulfano oral, após uso de dose teste e durante condicionamento, em pacientes submetidos a transplante alogênico de células-tronco hematopoiéticas
spellingShingle Monitoração terapêutica do bussulfano oral, após uso de dose teste e durante condicionamento, em pacientes submetidos a transplante alogênico de células-tronco hematopoiéticas
EFFTING, Cristiane
Bussulfano
Transplante de células-tronco hematopoiéticas
Cromatografia líquida
Farmacocinética
Busulfan
Liquid chromatography
Hematopoietic stem cell transplantation
Pharmacokinetics
CNPQ::CIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICA
title_short Monitoração terapêutica do bussulfano oral, após uso de dose teste e durante condicionamento, em pacientes submetidos a transplante alogênico de células-tronco hematopoiéticas
title_full Monitoração terapêutica do bussulfano oral, após uso de dose teste e durante condicionamento, em pacientes submetidos a transplante alogênico de células-tronco hematopoiéticas
title_fullStr Monitoração terapêutica do bussulfano oral, após uso de dose teste e durante condicionamento, em pacientes submetidos a transplante alogênico de células-tronco hematopoiéticas
title_full_unstemmed Monitoração terapêutica do bussulfano oral, após uso de dose teste e durante condicionamento, em pacientes submetidos a transplante alogênico de células-tronco hematopoiéticas
title_sort Monitoração terapêutica do bussulfano oral, após uso de dose teste e durante condicionamento, em pacientes submetidos a transplante alogênico de células-tronco hematopoiéticas
author EFFTING, Cristiane
author_facet EFFTING, Cristiane
author_role author
dc.contributor.advisor1.fl_str_mv CUNHA, Luiz Carlos da
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/6349547031976679
dc.contributor.advisor-co1.fl_str_mv ARANTES, Adriano de Moraes
dc.contributor.advisor-co1Lattes.fl_str_mv http://lattes.cnpq.br/2074071976957154
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/1445169752381815
dc.contributor.author.fl_str_mv EFFTING, Cristiane
contributor_str_mv CUNHA, Luiz Carlos da
ARANTES, Adriano de Moraes
dc.subject.por.fl_str_mv Bussulfano
Transplante de células-tronco hematopoiéticas
Cromatografia líquida
Farmacocinética
topic Bussulfano
Transplante de células-tronco hematopoiéticas
Cromatografia líquida
Farmacocinética
Busulfan
Liquid chromatography
Hematopoietic stem cell transplantation
Pharmacokinetics
CNPQ::CIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICA
dc.subject.eng.fl_str_mv Busulfan
Liquid chromatography
Hematopoietic stem cell transplantation
Pharmacokinetics
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICA
description Busulfan is an alkylating agent, used for conditioning patients undergoing hematopoietic stem cell transplantation (HSCT). It presents narrow therapeutic range and high variability in pharmacokinetics among patients and doses in the same patient. High plasma concentrations (> 1000 ng mL-1) have been related to toxicity, such as sinusoidal obstruction syndrome, whereas low levels (< 600 ng mL-1) have been associated with primary disease relapse or graft rejection. To avoid problems related to this treatment, therapeutic drug monitoring with dose adjustment has been proposed. Among the methods described, highperformance liquid chromatography (HPLC) is often used. This study aimed at optimizing and validating a technique to dose busulfan by HPLC coupled with photodiode array detector (PDA) and applying it to patientes undergoing HSCT in Goiás. We included eight patients in the group for therapeutic monitoring (MG) and eight in the control group (CG), i.e., with no intervention. Patients in the MG received the test dose (TD) 14 days before the treatment; after determining busulfan pharmacokinetic profile for each patient, the dose was adjusted to the therapeutic objective of 900 ng mL-1. The conditions for chromatography run were: HPLC/PDA, column ACE® C18 (150 mm x 4 mm); mobile phase methanol/water/acetonitrile (65:20:15, v/v/v); eluent flow rate of 1 mL min-1; internal standard 1,6-bis-(methanesulfonyloxy)hexane; UV detection &#955; = 276 nm; derivatization with sodium diethylcarbamate; liquid-liquid extraction with ethyl acetate after precipitation with acetonitrile. We included eight patients in the group for therapeutic monitoring (MG) and eight in the control group (CG). Results obtained: linearity, analyzed through the calibration curve, of 200 5000 ng mL-1; precision, in terms of repeatability (intra-run), of 1.25%-11.25%, and intermediary (inter-run), of 2.17%-10.71%; accuracy of 89.61%-102.18%; recovery of 89%. Half of the patients required dose increase and the mean dose administered was 1.02±0.19 mg kg-1. High variability was observed in assessed pharmacokinetic parameters: 38% variation in Css ____ between TD and conditioning regimen; half-life increased by 11%; ClT/F decreased by 30%, suggesting accumulation of busulfan when the drug is administered in a multiple dose regimen. Although lower than reported in the literature, this variation may be associated with toxicity or failure in treatment, justifying patient monitoring and enhancing validity of previous pharmacokinetic evaluation using TD regimen. Compared to the CG, this variation did not present impact on toxicity, mortality, and survival rates. Other studies with intervention during monitoring and a higher number of patients may present positive impact on the results of HSCT.
publishDate 2012
dc.date.available.fl_str_mv 2012-09-11
dc.date.issued.fl_str_mv 2012-04-13
dc.date.accessioned.fl_str_mv 2014-07-29T15:25:20Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv EFFTING, Cristiane. Therapeutic monitoring of oral busulfan, after the use of test dose and during conditioning regimen, in patients undergoing allogeneic hematopoietic stem cell transplantation. 2012. 181 f. Tese (Doutorado em Ciencias da Saude) - Universidade Federal de Goiás, Goiânia, 2012.
dc.identifier.uri.fl_str_mv http://repositorio.bc.ufg.br/tede/handle/tde/1539
dc.identifier.dark.fl_str_mv ark:/38995/00130000001sw
identifier_str_mv EFFTING, Cristiane. Therapeutic monitoring of oral busulfan, after the use of test dose and during conditioning regimen, in patients undergoing allogeneic hematopoietic stem cell transplantation. 2012. 181 f. Tese (Doutorado em Ciencias da Saude) - Universidade Federal de Goiás, Goiânia, 2012.
ark:/38995/00130000001sw
url http://repositorio.bc.ufg.br/tede/handle/tde/1539
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Goiás
dc.publisher.program.fl_str_mv Doutorado em Ciencias da Saude
dc.publisher.initials.fl_str_mv UFG
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Ciencias da Saude
publisher.none.fl_str_mv Universidade Federal de Goiás
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFG
instname:Universidade Federal de Goiás (UFG)
instacron:UFG
instname_str Universidade Federal de Goiás (UFG)
instacron_str UFG
institution UFG
reponame_str Repositório Institucional da UFG
collection Repositório Institucional da UFG
bitstream.url.fl_str_mv http://repositorio.bc.ufg.br/tede/bitstreams/f8ece6ca-b7e0-4da8-8c85-25e625bc343c/download
http://repositorio.bc.ufg.br/tede/bitstreams/43dba0df-47f0-4221-92c3-a2917d915cde/download
bitstream.checksum.fl_str_mv 16d94233a45ca7b200c1360cdad9a9d4
415a44f01aa8bc26043b72968a08d872
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)
repository.mail.fl_str_mv tasesdissertacoes.bc@ufg.br
_version_ 1815172508034269184