CONECTOR DE CISALHAMENTO EM PERFIL FORMADO A FRIO: ANÁLISE VIA MODELAGEM COMPUTACIONAL

Detalhes bibliográficos
Autor(a) principal: SILVA, Paulo Henrique Menezes
Data de Publicação: 2006
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFG
dARK ID: ark:/38995/0013000002261
Texto Completo: http://repositorio.bc.ufg.br/tede/handle/tde/672
Resumo: In a composite system, a steel beam (laminated, welded or cold formed) is associated with a concrete slab, forming a composite beam. The interaction between concrete and steel can be mechanical, by friction or, in some cases, only by adherence. One of the major advantages of the composite beams is the increase in strength and stiffness due to association of steel and concrete that makes possible the reduction of the height of the structural elements, implicating in material economy. The present research has the purpose to present a general vision of the structural behavior of the composite steel-concrete beams and to proceed to a more detailed study of the behavior of the shear connectors made from cold formed steel. A modeling study of the push-out test is accomplished with the intention to find the factors that influences the resistance and rigidity of the connection. The numerical study consists in the elaboration of a three-dimensional numerical model to simulate the push-out test from which is obtained the force-displacement curve, ultimate load, deformations and tensions along the connector. The numeric results are compared with obtained experimental values of rehearsals accomplished at laboratory for validation of the same ones. For the accomplishment of the numeric modeling the computational program ANSYS® 6.1 was used, which uses non-linear material and geometric Finite Element Method models. The numeric models present as variables of interest the thickness, the height of the shear connectors made of cold formed steel and the resistance of the concrete used in the premolded slab with reinforced concrete lattice joist. Results showed that the thickness of the connector is the most important variable in the connection strength, however the height of the connector also has influence in the resistance and, mainly, in the rigidity of the connection.
id UFG-2_9a2f2de1622df989b44d4ad0dac8ad06
oai_identifier_str oai:repositorio.bc.ufg.br:tde/672
network_acronym_str UFG-2
network_name_str Repositório Institucional da UFG
repository_id_str
spelling ARAÚJO, Daniel de Limahttp://lattes.cnpq.br/8801080897723883http://lattes.cnpq.br/0629193052837904SILVA, Paulo Henrique Menezes2014-07-29T15:03:37Z2010-01-122006-09-14SILVA, Paulo Henrique Menezes. CONECTOR DE CISALHAMENTO EM PERFIL FORMADO A FRIO: ANÁLISE VIA MODELAGEM COMPUTACIONAL. 2006. 185 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Goiás, Goiânia, 2006.http://repositorio.bc.ufg.br/tede/handle/tde/672ark:/38995/0013000002261In a composite system, a steel beam (laminated, welded or cold formed) is associated with a concrete slab, forming a composite beam. The interaction between concrete and steel can be mechanical, by friction or, in some cases, only by adherence. One of the major advantages of the composite beams is the increase in strength and stiffness due to association of steel and concrete that makes possible the reduction of the height of the structural elements, implicating in material economy. The present research has the purpose to present a general vision of the structural behavior of the composite steel-concrete beams and to proceed to a more detailed study of the behavior of the shear connectors made from cold formed steel. A modeling study of the push-out test is accomplished with the intention to find the factors that influences the resistance and rigidity of the connection. The numerical study consists in the elaboration of a three-dimensional numerical model to simulate the push-out test from which is obtained the force-displacement curve, ultimate load, deformations and tensions along the connector. The numeric results are compared with obtained experimental values of rehearsals accomplished at laboratory for validation of the same ones. For the accomplishment of the numeric modeling the computational program ANSYS® 6.1 was used, which uses non-linear material and geometric Finite Element Method models. The numeric models present as variables of interest the thickness, the height of the shear connectors made of cold formed steel and the resistance of the concrete used in the premolded slab with reinforced concrete lattice joist. Results showed that the thickness of the connector is the most important variable in the connection strength, however the height of the connector also has influence in the resistance and, mainly, in the rigidity of the connection.Denomina-se sistema misto aço-concreto aquele no qual um perfil de aço (laminado, dobrado ou soldado) trabalha em conjunto com uma laje de concreto, formando uma viga mista. A interação entre o concreto e o perfil de aço pode se dar por meios mecânicos, por atrito, ou, em alguns casos, por simples aderência. Uma das vantagens da utilização de vigas mistas em sistemas de pisos é o acréscimo de resistência e de rigidez propiciados pela associação dos elementos de aço e de concreto, o que possibilita a redução da altura dos elementos estruturais, implicando em economia de material. O presente trabalho tem por finalidade apresentar uma visão geral do comportamento estrutural das vigas mistas aço-concreto e proceder a um estudo mais detalhado do comportamento da ligação com conectores de cisalhamento tipo U em perfil formado a frio. É realizada a modelagem computacional do ensaio de cisalhamento direto (push-out test) com o intuito de determinar os fatores que mais influenciam na resistência e rigidez da ligação A modelagem computacional consiste na elaboração de um modelo numérico tridimensional para simular o ensaio de cisalhamento direto, do qual se obtém a curva força-deslocamento, a força última e as deformações e tensões ao longo do conector. Os resultados numéricos são confrontados com valores experimentais obtidos de ensaios realizados em laboratório para validação dos mesmos. Para a realização da modelagem computacional, foi utilizado o programa comercial ANSYS® 6.1, elaborado com base no Método dos Elementos Finitos, cujas ferramentas disponibilizadas permitem análises em regime de não-linearidade física e geométrica. Os modelos computacionais apresentam como variáveis de interesse a espessura e a altura do conector tipo perfil U formado a frio e a resistência do concreto utilizado na confecção das lajes treliçadas. Os resultados obtidos mostram que a espessura do conector é a variável que mais influência a resistência da ligação, porém a altura do conector também tem influência na resistência e, principalmente, na rigidez da ligação.Made available in DSpace on 2014-07-29T15:03:37Z (GMT). No. of bitstreams: 1 dissertacao paulo menezes.pdf: 3080026 bytes, checksum: 27fc4469f9413ad9117d4813295e9db7 (MD5) Previous issue date: 2006-09-14application/pdfhttp://repositorio.bc.ufg.br/TEDE/retrieve/3286/dissertacao%20paulo%20menezes.pdf.jpgporUniversidade Federal de GoiásMestrado em Engenharia CivilUFGBREngenhariasconector de cisalhamentoviga mista aço-concretoanálise computacionalnão-linearidade físicashear connectorcomposite steel-concrete beamnumerical analysisphysical non linearityCNPQ::ENGENHARIAS::ENGENHARIA CIVILCONECTOR DE CISALHAMENTO EM PERFIL FORMADO A FRIO: ANÁLISE VIA MODELAGEM COMPUTACIONALinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFGinstname:Universidade Federal de Goiás (UFG)instacron:UFGORIGINALdissertacao paulo menezes.pdfapplication/pdf3080026http://repositorio.bc.ufg.br/tede/bitstreams/e9718a0a-672a-484c-82c3-f3295dde6766/download27fc4469f9413ad9117d4813295e9db7MD51THUMBNAILdissertacao paulo menezes.pdf.jpgdissertacao paulo menezes.pdf.jpgGenerated Thumbnailimage/jpeg3075http://repositorio.bc.ufg.br/tede/bitstreams/f9d321c7-d3ae-4301-83b3-ad39c23e6c88/downloadff25c169569197c5208d57cbba612eceMD52tde/6722014-07-30 03:04:23.67open.accessoai:repositorio.bc.ufg.br:tde/672http://repositorio.bc.ufg.br/tedeRepositório InstitucionalPUBhttp://repositorio.bc.ufg.br/oai/requesttasesdissertacoes.bc@ufg.bropendoar:2014-07-30T06:04:23Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)false
dc.title.por.fl_str_mv CONECTOR DE CISALHAMENTO EM PERFIL FORMADO A FRIO: ANÁLISE VIA MODELAGEM COMPUTACIONAL
title CONECTOR DE CISALHAMENTO EM PERFIL FORMADO A FRIO: ANÁLISE VIA MODELAGEM COMPUTACIONAL
spellingShingle CONECTOR DE CISALHAMENTO EM PERFIL FORMADO A FRIO: ANÁLISE VIA MODELAGEM COMPUTACIONAL
SILVA, Paulo Henrique Menezes
conector de cisalhamento
viga mista aço-concreto
análise computacional
não-linearidade física
shear connector
composite steel-concrete beam
numerical analysis
physical non linearity
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
title_short CONECTOR DE CISALHAMENTO EM PERFIL FORMADO A FRIO: ANÁLISE VIA MODELAGEM COMPUTACIONAL
title_full CONECTOR DE CISALHAMENTO EM PERFIL FORMADO A FRIO: ANÁLISE VIA MODELAGEM COMPUTACIONAL
title_fullStr CONECTOR DE CISALHAMENTO EM PERFIL FORMADO A FRIO: ANÁLISE VIA MODELAGEM COMPUTACIONAL
title_full_unstemmed CONECTOR DE CISALHAMENTO EM PERFIL FORMADO A FRIO: ANÁLISE VIA MODELAGEM COMPUTACIONAL
title_sort CONECTOR DE CISALHAMENTO EM PERFIL FORMADO A FRIO: ANÁLISE VIA MODELAGEM COMPUTACIONAL
author SILVA, Paulo Henrique Menezes
author_facet SILVA, Paulo Henrique Menezes
author_role author
dc.contributor.advisor1.fl_str_mv ARAÚJO, Daniel de Lima
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/8801080897723883
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/0629193052837904
dc.contributor.author.fl_str_mv SILVA, Paulo Henrique Menezes
contributor_str_mv ARAÚJO, Daniel de Lima
dc.subject.por.fl_str_mv conector de cisalhamento
viga mista aço-concreto
análise computacional
não-linearidade física
topic conector de cisalhamento
viga mista aço-concreto
análise computacional
não-linearidade física
shear connector
composite steel-concrete beam
numerical analysis
physical non linearity
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
dc.subject.eng.fl_str_mv shear connector
composite steel-concrete beam
numerical analysis
physical non linearity
dc.subject.cnpq.fl_str_mv CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
description In a composite system, a steel beam (laminated, welded or cold formed) is associated with a concrete slab, forming a composite beam. The interaction between concrete and steel can be mechanical, by friction or, in some cases, only by adherence. One of the major advantages of the composite beams is the increase in strength and stiffness due to association of steel and concrete that makes possible the reduction of the height of the structural elements, implicating in material economy. The present research has the purpose to present a general vision of the structural behavior of the composite steel-concrete beams and to proceed to a more detailed study of the behavior of the shear connectors made from cold formed steel. A modeling study of the push-out test is accomplished with the intention to find the factors that influences the resistance and rigidity of the connection. The numerical study consists in the elaboration of a three-dimensional numerical model to simulate the push-out test from which is obtained the force-displacement curve, ultimate load, deformations and tensions along the connector. The numeric results are compared with obtained experimental values of rehearsals accomplished at laboratory for validation of the same ones. For the accomplishment of the numeric modeling the computational program ANSYS® 6.1 was used, which uses non-linear material and geometric Finite Element Method models. The numeric models present as variables of interest the thickness, the height of the shear connectors made of cold formed steel and the resistance of the concrete used in the premolded slab with reinforced concrete lattice joist. Results showed that the thickness of the connector is the most important variable in the connection strength, however the height of the connector also has influence in the resistance and, mainly, in the rigidity of the connection.
publishDate 2006
dc.date.issued.fl_str_mv 2006-09-14
dc.date.available.fl_str_mv 2010-01-12
dc.date.accessioned.fl_str_mv 2014-07-29T15:03:37Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv SILVA, Paulo Henrique Menezes. CONECTOR DE CISALHAMENTO EM PERFIL FORMADO A FRIO: ANÁLISE VIA MODELAGEM COMPUTACIONAL. 2006. 185 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Goiás, Goiânia, 2006.
dc.identifier.uri.fl_str_mv http://repositorio.bc.ufg.br/tede/handle/tde/672
dc.identifier.dark.fl_str_mv ark:/38995/0013000002261
identifier_str_mv SILVA, Paulo Henrique Menezes. CONECTOR DE CISALHAMENTO EM PERFIL FORMADO A FRIO: ANÁLISE VIA MODELAGEM COMPUTACIONAL. 2006. 185 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Goiás, Goiânia, 2006.
ark:/38995/0013000002261
url http://repositorio.bc.ufg.br/tede/handle/tde/672
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Goiás
dc.publisher.program.fl_str_mv Mestrado em Engenharia Civil
dc.publisher.initials.fl_str_mv UFG
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Engenharias
publisher.none.fl_str_mv Universidade Federal de Goiás
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFG
instname:Universidade Federal de Goiás (UFG)
instacron:UFG
instname_str Universidade Federal de Goiás (UFG)
instacron_str UFG
institution UFG
reponame_str Repositório Institucional da UFG
collection Repositório Institucional da UFG
bitstream.url.fl_str_mv http://repositorio.bc.ufg.br/tede/bitstreams/e9718a0a-672a-484c-82c3-f3295dde6766/download
http://repositorio.bc.ufg.br/tede/bitstreams/f9d321c7-d3ae-4301-83b3-ad39c23e6c88/download
bitstream.checksum.fl_str_mv 27fc4469f9413ad9117d4813295e9db7
ff25c169569197c5208d57cbba612ece
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)
repository.mail.fl_str_mv tasesdissertacoes.bc@ufg.br
_version_ 1815172530466455552