O efeito da espessura do esmalte e dentina na interpretação do oxímetro de pulso

Detalhes bibliográficos
Autor(a) principal: Sestari, Larissa Emanuelle
Data de Publicação: 2020
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFG
dARK ID: ark:/38995/001300000c465
Texto Completo: http://repositorio.bc.ufg.br/tede/handle/tede/12783
Resumo: Introduction: The thickness of the dental substrate is a factor that interferes with the result of the evaluation of the pulp oxygen saturation level, capable of reducing the pulse oximeter accuracy. This study evaluated the interference of enamel-dentin thickness in the interpretation of the pulse oximeter, having as variation factors the finger oxygen saturation and the presence and absence of light. Materials and Methods: Forty-two healthy human lower molars were sectioned centrally in the mesiodistal direction. After sectioning, the buccal and lingual faces were worn on the dentin surface and evaluated at 4.0mm, 3.0mm and 2.0mm thickness. A reference device was made for the alignment of the pulse oximeter diode, buccal tooth face, participant's little finger, lingual face and receiving diode. The positive control of the experiment was performed on the participant's finger without interposition of the dental faces, and the negative by juxtaposition of the dental faces without the participant's finger. All measurements were performed in the presence and absence of light. The variables were described by the mean and standard deviation, and the confidence interval presented. To compare the groups, analysis of variance (ANOVA) was used, followed by Bonferroni correction. Student's t-test was used to compare paired samples, and to assess the correlation between oxygen saturation and pulse level, the Pearson Correlation Coefficient was used. The significance level of 5%. Results: The average level of oxygen saturation in the finger was lower when the dental structure of 4.00.2mm, 92.7% and 89.3% was interposed, in the presence and absence of light, respectively, than when it was 3.00.2mm, 95.5% and 94.5%, and 2.00.2mm, 96.4% and 96.0% (P <0.001). The mean oxygen saturation level in the positive control was 96.1%. In the negative control samples, no oximetry and pulse results were recorded. Conclusions: The thickness of the dental structure interfered with the pulse oximeter interpretation, with significant reduction of oxygen saturation level for larger thicknesses, and the presence and absence of light changed the pulse oximeter interpretation.
id UFG-2_c54dc74fd4b69fafaaf248d8de5cb05e
oai_identifier_str oai:repositorio.bc.ufg.br:tede/12783
network_acronym_str UFG-2
network_name_str Repositório Institucional da UFG
repository_id_str
spelling Silva, Julio Almeidahttp://lattes.cnpq.br/1022830186974104Alencar, Ana Helena Gonçalves dehttp://lattes.cnpq.br/2039898015468283Silva, Julio AlmeidaEstrela, CarlosGuedes, Orlando Aguirrehttp://lattes.cnpq.br/7699689104635768Sestari, Larissa Emanuelle2023-04-25T12:49:08Z2023-04-25T12:49:08Z2020-02-28SESTARI, L. E. O efeito da espessura do esmalte e dentina na interpretação do oxímetro de pulso. 2020. 47 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Goiás, Goiânia, 2020.http://repositorio.bc.ufg.br/tede/handle/tede/12783ark:/38995/001300000c465Introduction: The thickness of the dental substrate is a factor that interferes with the result of the evaluation of the pulp oxygen saturation level, capable of reducing the pulse oximeter accuracy. This study evaluated the interference of enamel-dentin thickness in the interpretation of the pulse oximeter, having as variation factors the finger oxygen saturation and the presence and absence of light. Materials and Methods: Forty-two healthy human lower molars were sectioned centrally in the mesiodistal direction. After sectioning, the buccal and lingual faces were worn on the dentin surface and evaluated at 4.0mm, 3.0mm and 2.0mm thickness. A reference device was made for the alignment of the pulse oximeter diode, buccal tooth face, participant's little finger, lingual face and receiving diode. The positive control of the experiment was performed on the participant's finger without interposition of the dental faces, and the negative by juxtaposition of the dental faces without the participant's finger. All measurements were performed in the presence and absence of light. The variables were described by the mean and standard deviation, and the confidence interval presented. To compare the groups, analysis of variance (ANOVA) was used, followed by Bonferroni correction. Student's t-test was used to compare paired samples, and to assess the correlation between oxygen saturation and pulse level, the Pearson Correlation Coefficient was used. The significance level of 5%. Results: The average level of oxygen saturation in the finger was lower when the dental structure of 4.00.2mm, 92.7% and 89.3% was interposed, in the presence and absence of light, respectively, than when it was 3.00.2mm, 95.5% and 94.5%, and 2.00.2mm, 96.4% and 96.0% (P <0.001). The mean oxygen saturation level in the positive control was 96.1%. In the negative control samples, no oximetry and pulse results were recorded. Conclusions: The thickness of the dental structure interfered with the pulse oximeter interpretation, with significant reduction of oxygen saturation level for larger thicknesses, and the presence and absence of light changed the pulse oximeter interpretation.Introdução: A espessura do substrato dentário constitui-se um fator que interfere no resultado da avaliação do nível de saturação de oxigênio da polpa, capaz de reduzir a acurácia do oxímetro de pulso. Este estudo avaliou a interferência da espessura de esmalte-dentina na interpretação do oxímetro de pulso, tendo como fatores de variação a saturação de oxigênio do dedo e a presença e ausência de luz. Materiais e Métodos: Quarenta e dois molares inferiores humanos hígidos foram seccionados na porção central no sentido mesiodistal. Após o seccionamento, as faces vestibular e lingual foram desgastadas na superfície correspondente à dentina e avaliadas nas espessuras de 4,0mm, 3,0mm e 2,0mm. Foi confeccionado um dispositivo de referência para o alinhamento do diodo emissor do oxímetro de pulso, face vestibular do dente, dedo mínimo do participante, face lingual e diodo receptor. O controle positivo do experimento foi realizado no dedo do participante sem a interposição das faces dentárias, e o negativo, por meio da justaposição das faces dentárias, sem o dedo do participante. Todas as mensurações foram efetuadas na presença e ausência de luz. As variáveis foram descritas pela média e desvio-padrão, e o intervalo de confiança apresentado. Para comparar os grupos foi empregada a análise de variância (ANOVA), seguida da Correção de Bonferroni. O teste t de Student foi usado para comparar amostras emparelhadas, e para avaliar a correlação entre o nível de saturação de oxigênio e do pulso foi utilizado o Coeficiente de Correlação de Pearson. Considerou-se o nível de significância de 5%. Resultados: O nível médio de saturação de oxigênio no dedo mostrou-se mais baixo quando foi interposta a estrutura dentária de 4,00,2mm, 92,7% e 89,3%, na presença e ausência de luz, respectivamente, do que quando foi a de 3,00,2mm, 95,5% e 94,5%, e a de 2,00,2mm, 96,4% e 96,0% (P<0,001). O nível médio de oxigênio no controle positivo foi de 96,1%. Na amostras do controle negativo não foi registrado resultado de oximetria e de pulso. Conclusões: A espessura da estrutura dentária interferiu na interpretação do oxímetro de pulso, com redução significativa do nível de saturação de oxigênio para espessuras maiores, e a presença e ausência de luz alteraram a interpretação do oxímetro de pulso.Submitted by Marlene Santos (marlene.bc.ufg@gmail.com) on 2023-04-24T20:16:47Z No. of bitstreams: 2 Dissertação - Larissa Emanuelle Sestari - 2020.pdf: 1009153 bytes, checksum: e6cc9d1aa000550fef30ffda3564a1a7 (MD5) license_rdf: 805 bytes, checksum: 4460e5956bc1d1639be9ae6146a50347 (MD5)Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2023-04-25T12:49:08Z (GMT) No. of bitstreams: 2 Dissertação - Larissa Emanuelle Sestari - 2020.pdf: 1009153 bytes, checksum: e6cc9d1aa000550fef30ffda3564a1a7 (MD5) license_rdf: 805 bytes, checksum: 4460e5956bc1d1639be9ae6146a50347 (MD5)Made available in DSpace on 2023-04-25T12:49:08Z (GMT). No. of bitstreams: 2 Dissertação - Larissa Emanuelle Sestari - 2020.pdf: 1009153 bytes, checksum: e6cc9d1aa000550fef30ffda3564a1a7 (MD5) license_rdf: 805 bytes, checksum: 4460e5956bc1d1639be9ae6146a50347 (MD5) Previous issue date: 2020-02-28OutroporUniversidade Federal de GoiásPrograma de Pós-graduação em Odontologia (FO)UFGBrasilFaculdade de Odontologia - FO (RMG)Attribution-NonCommercial-NoDerivatives 4.0 Internationalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessOximetria de pulsoEndodontiaPolpa dentáriaPulse oximetryEndodonticsDental pulpCIENCIAS DA SAUDE::ODONTOLOGIA::ENDODONTIAO efeito da espessura do esmalte e dentina na interpretação do oxímetro de pulsoInterference of coronal enamel and dentin thickness and ambient light on pulse oximetry interpretationinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis79500500500500219145reponame:Repositório Institucional da UFGinstname:Universidade Federal de Goiás (UFG)instacron:UFGLICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://repositorio.bc.ufg.br/tede/bitstreams/c1624701-309c-475d-bda9-cb60a35e0bc3/download8a4605be74aa9ea9d79846c1fba20a33MD51CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8805http://repositorio.bc.ufg.br/tede/bitstreams/484c8874-69d1-4d51-a0f9-bf10d3984d9e/download4460e5956bc1d1639be9ae6146a50347MD52ORIGINALDissertação - Larissa Emanuelle Sestari - 2020.pdfDissertação - Larissa Emanuelle Sestari - 2020.pdfapplication/pdf1009153http://repositorio.bc.ufg.br/tede/bitstreams/8fc6ea49-5738-40df-a40f-77074d1744c7/downloade6cc9d1aa000550fef30ffda3564a1a7MD53tede/127832023-04-25 09:49:08.414http://creativecommons.org/licenses/by-nc-nd/4.0/Attribution-NonCommercial-NoDerivatives 4.0 Internationalopen.accessoai:repositorio.bc.ufg.br:tede/12783http://repositorio.bc.ufg.br/tedeRepositório InstitucionalPUBhttp://repositorio.bc.ufg.br/oai/requesttasesdissertacoes.bc@ufg.bropendoar:2023-04-25T12:49:08Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)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
dc.title.pt_BR.fl_str_mv O efeito da espessura do esmalte e dentina na interpretação do oxímetro de pulso
dc.title.alternative.eng.fl_str_mv Interference of coronal enamel and dentin thickness and ambient light on pulse oximetry interpretation
title O efeito da espessura do esmalte e dentina na interpretação do oxímetro de pulso
spellingShingle O efeito da espessura do esmalte e dentina na interpretação do oxímetro de pulso
Sestari, Larissa Emanuelle
Oximetria de pulso
Endodontia
Polpa dentária
Pulse oximetry
Endodontics
Dental pulp
CIENCIAS DA SAUDE::ODONTOLOGIA::ENDODONTIA
title_short O efeito da espessura do esmalte e dentina na interpretação do oxímetro de pulso
title_full O efeito da espessura do esmalte e dentina na interpretação do oxímetro de pulso
title_fullStr O efeito da espessura do esmalte e dentina na interpretação do oxímetro de pulso
title_full_unstemmed O efeito da espessura do esmalte e dentina na interpretação do oxímetro de pulso
title_sort O efeito da espessura do esmalte e dentina na interpretação do oxímetro de pulso
author Sestari, Larissa Emanuelle
author_facet Sestari, Larissa Emanuelle
author_role author
dc.contributor.advisor1.fl_str_mv Silva, Julio Almeida
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/1022830186974104
dc.contributor.advisor-co1.fl_str_mv Alencar, Ana Helena Gonçalves de
dc.contributor.advisor-co1Lattes.fl_str_mv http://lattes.cnpq.br/2039898015468283
dc.contributor.referee1.fl_str_mv Silva, Julio Almeida
dc.contributor.referee2.fl_str_mv Estrela, Carlos
dc.contributor.referee3.fl_str_mv Guedes, Orlando Aguirre
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/7699689104635768
dc.contributor.author.fl_str_mv Sestari, Larissa Emanuelle
contributor_str_mv Silva, Julio Almeida
Alencar, Ana Helena Gonçalves de
Silva, Julio Almeida
Estrela, Carlos
Guedes, Orlando Aguirre
dc.subject.por.fl_str_mv Oximetria de pulso
Endodontia
Polpa dentária
topic Oximetria de pulso
Endodontia
Polpa dentária
Pulse oximetry
Endodontics
Dental pulp
CIENCIAS DA SAUDE::ODONTOLOGIA::ENDODONTIA
dc.subject.eng.fl_str_mv Pulse oximetry
Endodontics
Dental pulp
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE::ODONTOLOGIA::ENDODONTIA
description Introduction: The thickness of the dental substrate is a factor that interferes with the result of the evaluation of the pulp oxygen saturation level, capable of reducing the pulse oximeter accuracy. This study evaluated the interference of enamel-dentin thickness in the interpretation of the pulse oximeter, having as variation factors the finger oxygen saturation and the presence and absence of light. Materials and Methods: Forty-two healthy human lower molars were sectioned centrally in the mesiodistal direction. After sectioning, the buccal and lingual faces were worn on the dentin surface and evaluated at 4.0mm, 3.0mm and 2.0mm thickness. A reference device was made for the alignment of the pulse oximeter diode, buccal tooth face, participant's little finger, lingual face and receiving diode. The positive control of the experiment was performed on the participant's finger without interposition of the dental faces, and the negative by juxtaposition of the dental faces without the participant's finger. All measurements were performed in the presence and absence of light. The variables were described by the mean and standard deviation, and the confidence interval presented. To compare the groups, analysis of variance (ANOVA) was used, followed by Bonferroni correction. Student's t-test was used to compare paired samples, and to assess the correlation between oxygen saturation and pulse level, the Pearson Correlation Coefficient was used. The significance level of 5%. Results: The average level of oxygen saturation in the finger was lower when the dental structure of 4.00.2mm, 92.7% and 89.3% was interposed, in the presence and absence of light, respectively, than when it was 3.00.2mm, 95.5% and 94.5%, and 2.00.2mm, 96.4% and 96.0% (P <0.001). The mean oxygen saturation level in the positive control was 96.1%. In the negative control samples, no oximetry and pulse results were recorded. Conclusions: The thickness of the dental structure interfered with the pulse oximeter interpretation, with significant reduction of oxygen saturation level for larger thicknesses, and the presence and absence of light changed the pulse oximeter interpretation.
publishDate 2020
dc.date.issued.fl_str_mv 2020-02-28
dc.date.accessioned.fl_str_mv 2023-04-25T12:49:08Z
dc.date.available.fl_str_mv 2023-04-25T12:49:08Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv SESTARI, L. E. O efeito da espessura do esmalte e dentina na interpretação do oxímetro de pulso. 2020. 47 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Goiás, Goiânia, 2020.
dc.identifier.uri.fl_str_mv http://repositorio.bc.ufg.br/tede/handle/tede/12783
dc.identifier.dark.fl_str_mv ark:/38995/001300000c465
identifier_str_mv SESTARI, L. E. O efeito da espessura do esmalte e dentina na interpretação do oxímetro de pulso. 2020. 47 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Goiás, Goiânia, 2020.
ark:/38995/001300000c465
url http://repositorio.bc.ufg.br/tede/handle/tede/12783
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv 79
dc.relation.confidence.fl_str_mv 500
500
500
500
dc.relation.department.fl_str_mv 21
dc.relation.cnpq.fl_str_mv 914
dc.relation.sponsorship.fl_str_mv 5
dc.rights.driver.fl_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade Federal de Goiás
dc.publisher.program.fl_str_mv Programa de Pós-graduação em Odontologia (FO)
dc.publisher.initials.fl_str_mv UFG
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Faculdade de Odontologia - FO (RMG)
publisher.none.fl_str_mv Universidade Federal de Goiás
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFG
instname:Universidade Federal de Goiás (UFG)
instacron:UFG
instname_str Universidade Federal de Goiás (UFG)
instacron_str UFG
institution UFG
reponame_str Repositório Institucional da UFG
collection Repositório Institucional da UFG
bitstream.url.fl_str_mv http://repositorio.bc.ufg.br/tede/bitstreams/c1624701-309c-475d-bda9-cb60a35e0bc3/download
http://repositorio.bc.ufg.br/tede/bitstreams/484c8874-69d1-4d51-a0f9-bf10d3984d9e/download
http://repositorio.bc.ufg.br/tede/bitstreams/8fc6ea49-5738-40df-a40f-77074d1744c7/download
bitstream.checksum.fl_str_mv 8a4605be74aa9ea9d79846c1fba20a33
4460e5956bc1d1639be9ae6146a50347
e6cc9d1aa000550fef30ffda3564a1a7
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)
repository.mail.fl_str_mv tasesdissertacoes.bc@ufg.br
_version_ 1815172628650917888