Concreto projetado como revestimento de túneis na Ferrovia Norte-Sul: análise segundo parâmetros de durabilidade
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFG |
dARK ID: | ark:/38995/0013000005vg4 |
Texto Completo: | http://repositorio.bc.ufg.br/tede/handle/tde/1327 |
Resumo: | The present work aims to analyse the durability parameters of the shotcrete, comparing the dry and wet projection systems, of the concrete resulting from the projection in plates and from the test specimens extracted from the tunnels structures of the North-South Railway, tract 01, in Anápolis-GO. This work considers an experimental research concerning the shotcrete behavior for dry-mix and wet-mix projection systems, by using testing indicators of the main durability parameters coming from national and international specifications. So, the experimental program involves a comparative assessment among the projection systems of current use in shotcrete, considering the comparative analysis between projected plates (control) and extracted test specimens from the tunnels on what refers to meeting the requirements related to durability. Therefore, the experimental program showed as independent variables: type of projection system (whether by means of dry-mix or wet-mix shotcrete) and the extraction of test specimen (from the control plates or from the tunnels structure). For each type of projection (dry-mix and wet-mix shotcrete), three plates were cast (normally used for concrete technological control) in conditions similar to the work-site, with the test specimens extraction been carried out according to pre-established ages. Eight test specimens were extracted from the just-builts tunnels generating thus samples to the durability associated tests, such as: capillary water absorption, immersion water absorption, concrete electric resistivity, water penetration under pressure, penetrability of chloride ions and concrete compressive strenght. Test specimens extracted from the tunnels and the from the plates were also submitted to testings of compressive strenght and mix-proportion reconstruction. The concrete extracted from tunnels showed worse results comparing to the parameters expected from the projected concrete requirements for road and rail tunnels, and it also demonstrated results which were inferior to the ones obtained from the plates. From a general assessment view, we could verify losses of durability properties of the shotcrete extracted from tunnels in reference to the projected plates. |
id |
UFG-2_d6565e5467eab52b59d71a7b8498d638 |
---|---|
oai_identifier_str |
oai:repositorio.bc.ufg.br:tde/1327 |
network_acronym_str |
UFG-2 |
network_name_str |
Repositório Institucional da UFG |
repository_id_str |
|
spelling |
CASCUDO, Oswaldohttp://lattes.cnpq.br/3336749062812376http://lattes.cnpq.br/2349103868174439MENESES, Antônio Davi Barbosa de2014-07-29T15:18:20Z2011-02-282010-09-24MENESES, Antônio Davi Barbosa de. Shotcrete tunnel lining as the Railroad North-South: second analysis parameters durability. 2010. 166 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Goiás, Goiânia, 2010.http://repositorio.bc.ufg.br/tede/handle/tde/1327ark:/38995/0013000005vg4The present work aims to analyse the durability parameters of the shotcrete, comparing the dry and wet projection systems, of the concrete resulting from the projection in plates and from the test specimens extracted from the tunnels structures of the North-South Railway, tract 01, in Anápolis-GO. This work considers an experimental research concerning the shotcrete behavior for dry-mix and wet-mix projection systems, by using testing indicators of the main durability parameters coming from national and international specifications. So, the experimental program involves a comparative assessment among the projection systems of current use in shotcrete, considering the comparative analysis between projected plates (control) and extracted test specimens from the tunnels on what refers to meeting the requirements related to durability. Therefore, the experimental program showed as independent variables: type of projection system (whether by means of dry-mix or wet-mix shotcrete) and the extraction of test specimen (from the control plates or from the tunnels structure). For each type of projection (dry-mix and wet-mix shotcrete), three plates were cast (normally used for concrete technological control) in conditions similar to the work-site, with the test specimens extraction been carried out according to pre-established ages. Eight test specimens were extracted from the just-builts tunnels generating thus samples to the durability associated tests, such as: capillary water absorption, immersion water absorption, concrete electric resistivity, water penetration under pressure, penetrability of chloride ions and concrete compressive strenght. Test specimens extracted from the tunnels and the from the plates were also submitted to testings of compressive strenght and mix-proportion reconstruction. The concrete extracted from tunnels showed worse results comparing to the parameters expected from the projected concrete requirements for road and rail tunnels, and it also demonstrated results which were inferior to the ones obtained from the plates. From a general assessment view, we could verify losses of durability properties of the shotcrete extracted from tunnels in reference to the projected plates.O presente trabalho tem como objetivo analisar os parâmetros de durabilidade do concreto projetado, comparando os sistemas de projeção via seca e via úmida, dos concretos resultantes da projeção em placas e dos testemunhos extraídos das estruturas dos túneis da Ferrovia Norte-Sul, trecho 01, em Anápolis-GO. Este trabalho contempla um estudo experimental de análise do comportamento de concretos projetados por via seca e úmida, através de ensaios indicadores dos principais parâmetros de durabilidade, constantes das especificações nacionais e internacionais. O programa experimental envolve, portanto, a avaliação entre os sistemas de projeção de uso corrente em concreto projetado, considerando a análise comparativa entre as placas projetadas (de controle) e os testemunhos extraídos dos túneis, no que se refere ao atendimento aos requisitos relativos à durabilidade. Para tanto, o programa experimental teve como variáveis independentes: tipo de sistema de projeção (se por via seca ou por via úmida) e a extração dos corpos-de-prova de concreto (da placa ou do túnel). Para cada tipo de projeção (via seca e via úmida) foram moldadas três placas (normalmente utilizadas para os fins de controle tecnológico do concreto) em condições similares às da obra, tendo-se em seguida, nas idades preestabelecidas, executado-se a extração de corpos-de-prova. Foram também extraídos oito testemunhos dos túneis executados, gerando, assim, corpos-de-prova submetidos aos ensaios balizadores dos parâmetros de durabilidade adotados neste estudo, a saber: absorção de água por capilaridade, absorção por imersão e fervura, resistividade elétrica, penetração de água sob pressão, penetrabilidade de íons cloreto e resistência à compressão axial. Contribuíram também para a caracterização do material os corpos-de-prova extraídos dos túneis e das placas, que foram submetidos a ensaios de resistência à compressão axial e de reconstituição de traço. Os concretos extraídos dos túneis mostraram resultados abaixo dos parâmetros para os resultados esperados dos requisitos de concreto projetado para os túneis rodo-ferroviários, e ainda com resultados inferiores aos resultados obtidos das placas. Numa avaliação geral, constatou-se perdas de propriedades de durabilidade do concreto projetado extraídos dos túneis em referência aos das placas projetadas.Made available in DSpace on 2014-07-29T15:18:20Z (GMT). No. of bitstreams: 1 antonio davi barbosa.pdf: 7758896 bytes, checksum: ca05d091a1db99ebc27e5221e6137f79 (MD5) Previous issue date: 2010-09-24application/pdfhttp://repositorio.bc.ufg.br/TEDE/retrieve/4117/antonio%20davi%20barbosa.pdf.jpgporUniversidade Federal de GoiásMestrado em Geotecnia e Construção CivilUFGBREngenhariasconcretodurabilidadetúneisconcreto projetadovia secavia úmida1.Concreto 2.Durabilidade 3.Túneis Concreto Projetado Via seca Via úmidaconcretedurabilitytunnelssprayed concreteshotcretedry-mix and wet-mix shotcreteCNPQ::ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVILConcreto projetado como revestimento de túneis na Ferrovia Norte-Sul: análise segundo parâmetros de durabilidadeShotcrete tunnel lining as the Railroad North-South: second analysis parameters durabilityinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFGinstname:Universidade Federal de Goiás (UFG)instacron:UFGORIGINALantonio davi barbosa.pdfapplication/pdf7758896http://repositorio.bc.ufg.br/tede/bitstreams/edec0653-dfc8-4327-83e5-dc24bef8d12c/downloadca05d091a1db99ebc27e5221e6137f79MD51TEXTantonio davi barbosa.pdf.txtantonio davi barbosa.pdf.txtExtracted Texttext/plain316602http://repositorio.bc.ufg.br/tede/bitstreams/3864defe-1b35-4248-99d2-c5c27076e4df/downloada22bf1e5fa9b0fc621a84f002de5e0a2MD52THUMBNAILantonio davi barbosa.pdf.jpgantonio davi barbosa.pdf.jpgGenerated Thumbnailimage/jpeg1943http://repositorio.bc.ufg.br/tede/bitstreams/45720e3a-5b61-45c7-9115-ee27f5fcc654/downloadcc73c4c239a4c332d642ba1e7c7a9fb2MD53tde/13272014-07-30 03:11:23.727open.accessoai:repositorio.bc.ufg.br:tde/1327http://repositorio.bc.ufg.br/tedeRepositório InstitucionalPUBhttp://repositorio.bc.ufg.br/oai/requesttasesdissertacoes.bc@ufg.bropendoar:2014-07-30T06:11:23Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)false |
dc.title.por.fl_str_mv |
Concreto projetado como revestimento de túneis na Ferrovia Norte-Sul: análise segundo parâmetros de durabilidade |
dc.title.alternative.eng.fl_str_mv |
Shotcrete tunnel lining as the Railroad North-South: second analysis parameters durability |
title |
Concreto projetado como revestimento de túneis na Ferrovia Norte-Sul: análise segundo parâmetros de durabilidade |
spellingShingle |
Concreto projetado como revestimento de túneis na Ferrovia Norte-Sul: análise segundo parâmetros de durabilidade MENESES, Antônio Davi Barbosa de concreto durabilidade túneis concreto projetado via seca via úmida 1.Concreto 2.Durabilidade 3.Túneis Concreto Projetado Via seca Via úmida concrete durability tunnels sprayed concrete shotcrete dry-mix and wet-mix shotcrete CNPQ::ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVIL |
title_short |
Concreto projetado como revestimento de túneis na Ferrovia Norte-Sul: análise segundo parâmetros de durabilidade |
title_full |
Concreto projetado como revestimento de túneis na Ferrovia Norte-Sul: análise segundo parâmetros de durabilidade |
title_fullStr |
Concreto projetado como revestimento de túneis na Ferrovia Norte-Sul: análise segundo parâmetros de durabilidade |
title_full_unstemmed |
Concreto projetado como revestimento de túneis na Ferrovia Norte-Sul: análise segundo parâmetros de durabilidade |
title_sort |
Concreto projetado como revestimento de túneis na Ferrovia Norte-Sul: análise segundo parâmetros de durabilidade |
author |
MENESES, Antônio Davi Barbosa de |
author_facet |
MENESES, Antônio Davi Barbosa de |
author_role |
author |
dc.contributor.advisor1.fl_str_mv |
CASCUDO, Oswaldo |
dc.contributor.advisor1Lattes.fl_str_mv |
http://lattes.cnpq.br/3336749062812376 |
dc.contributor.authorLattes.fl_str_mv |
http://lattes.cnpq.br/2349103868174439 |
dc.contributor.author.fl_str_mv |
MENESES, Antônio Davi Barbosa de |
contributor_str_mv |
CASCUDO, Oswaldo |
dc.subject.por.fl_str_mv |
concreto durabilidade túneis concreto projetado via seca via úmida 1.Concreto 2.Durabilidade 3.Túneis Concreto Projetado Via seca Via úmida |
topic |
concreto durabilidade túneis concreto projetado via seca via úmida 1.Concreto 2.Durabilidade 3.Túneis Concreto Projetado Via seca Via úmida concrete durability tunnels sprayed concrete shotcrete dry-mix and wet-mix shotcrete CNPQ::ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVIL |
dc.subject.eng.fl_str_mv |
concrete durability tunnels sprayed concrete shotcrete dry-mix and wet-mix shotcrete |
dc.subject.cnpq.fl_str_mv |
CNPQ::ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVIL |
description |
The present work aims to analyse the durability parameters of the shotcrete, comparing the dry and wet projection systems, of the concrete resulting from the projection in plates and from the test specimens extracted from the tunnels structures of the North-South Railway, tract 01, in Anápolis-GO. This work considers an experimental research concerning the shotcrete behavior for dry-mix and wet-mix projection systems, by using testing indicators of the main durability parameters coming from national and international specifications. So, the experimental program involves a comparative assessment among the projection systems of current use in shotcrete, considering the comparative analysis between projected plates (control) and extracted test specimens from the tunnels on what refers to meeting the requirements related to durability. Therefore, the experimental program showed as independent variables: type of projection system (whether by means of dry-mix or wet-mix shotcrete) and the extraction of test specimen (from the control plates or from the tunnels structure). For each type of projection (dry-mix and wet-mix shotcrete), three plates were cast (normally used for concrete technological control) in conditions similar to the work-site, with the test specimens extraction been carried out according to pre-established ages. Eight test specimens were extracted from the just-builts tunnels generating thus samples to the durability associated tests, such as: capillary water absorption, immersion water absorption, concrete electric resistivity, water penetration under pressure, penetrability of chloride ions and concrete compressive strenght. Test specimens extracted from the tunnels and the from the plates were also submitted to testings of compressive strenght and mix-proportion reconstruction. The concrete extracted from tunnels showed worse results comparing to the parameters expected from the projected concrete requirements for road and rail tunnels, and it also demonstrated results which were inferior to the ones obtained from the plates. From a general assessment view, we could verify losses of durability properties of the shotcrete extracted from tunnels in reference to the projected plates. |
publishDate |
2010 |
dc.date.issued.fl_str_mv |
2010-09-24 |
dc.date.available.fl_str_mv |
2011-02-28 |
dc.date.accessioned.fl_str_mv |
2014-07-29T15:18:20Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
MENESES, Antônio Davi Barbosa de. Shotcrete tunnel lining as the Railroad North-South: second analysis parameters durability. 2010. 166 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Goiás, Goiânia, 2010. |
dc.identifier.uri.fl_str_mv |
http://repositorio.bc.ufg.br/tede/handle/tde/1327 |
dc.identifier.dark.fl_str_mv |
ark:/38995/0013000005vg4 |
identifier_str_mv |
MENESES, Antônio Davi Barbosa de. Shotcrete tunnel lining as the Railroad North-South: second analysis parameters durability. 2010. 166 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Goiás, Goiânia, 2010. ark:/38995/0013000005vg4 |
url |
http://repositorio.bc.ufg.br/tede/handle/tde/1327 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Goiás |
dc.publisher.program.fl_str_mv |
Mestrado em Geotecnia e Construção Civil |
dc.publisher.initials.fl_str_mv |
UFG |
dc.publisher.country.fl_str_mv |
BR |
dc.publisher.department.fl_str_mv |
Engenharias |
publisher.none.fl_str_mv |
Universidade Federal de Goiás |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFG instname:Universidade Federal de Goiás (UFG) instacron:UFG |
instname_str |
Universidade Federal de Goiás (UFG) |
instacron_str |
UFG |
institution |
UFG |
reponame_str |
Repositório Institucional da UFG |
collection |
Repositório Institucional da UFG |
bitstream.url.fl_str_mv |
http://repositorio.bc.ufg.br/tede/bitstreams/edec0653-dfc8-4327-83e5-dc24bef8d12c/download http://repositorio.bc.ufg.br/tede/bitstreams/3864defe-1b35-4248-99d2-c5c27076e4df/download http://repositorio.bc.ufg.br/tede/bitstreams/45720e3a-5b61-45c7-9115-ee27f5fcc654/download |
bitstream.checksum.fl_str_mv |
ca05d091a1db99ebc27e5221e6137f79 a22bf1e5fa9b0fc621a84f002de5e0a2 cc73c4c239a4c332d642ba1e7c7a9fb2 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFG - Universidade Federal de Goiás (UFG) |
repository.mail.fl_str_mv |
tasesdissertacoes.bc@ufg.br |
_version_ |
1815172571845361664 |