Análise do conforto ambiental em salas de aula da Universidade Federal de Goiás

Detalhes bibliográficos
Autor(a) principal: Ochoa, Juliana Herlemann
Data de Publicação: 2010
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFG
Texto Completo: http://repositorio.bc.ufg.br/tede/handle/tede/12166
Resumo: Provide users good physical conditions in educational institutions is essential for the proper development of teaching and learning. This work deals with the verification in-loco of the environmental comfort of classrooms in two buildings with different architectural and construction techniques, that are part of the structure of the Federal University of Goiás. So the research aimed at exploring these buildings in order to identify the peculiarities of its thermal, acoustic and light performance which are being influenced by the technologies adopted and the physical conformation of the same. The technical data collected were analyzed by type of comfort. In lighting comfort, measurements were carried out near the solstices and equinoxes and the data collected were analyzed by means of ambient illuminance, uniformity coefficient and contribution of artificial light. The thermal comfort data collected were temperature and relative humidity for a period of approximately 11 months, which were assessed using the concept of comfort zone, degree-hours analysis and absolute maximum and minimum values. The acoustic measurements collected the sound pressure levels and occurred over a day of daily activities in both buildings. It was noted that there is an influence of the architectural elements of environmental comfort in buildings. Among other factors, one that can be highlighted is that despite having similar solar orientation, which is a comfort condition, the results of the environmental performance of each of the buildings were quite different. Parallel to these technical assessments were also done a periodic application of questionnaires to the users of the classroom, one per season, which sought to characterize the perception of these in relation to each of the types of comfort. Finally, a correlation was established between the technical data collected and perceptive. In most of cases, the opinions expressed by users were not consistent with the results evaluated by measurement techniques, thus demonstrating a difference between the comfort zone adopted and the actual user satisfaction of the buildings.
id UFG-2_eafdbcb085cfa96b2af89ea06053e183
oai_identifier_str oai:repositorio.bc.ufg.br:tede/12166
network_acronym_str UFG-2
network_name_str Repositório Institucional da UFG
repository_id_str
spelling Araújo, Daniel de Limahttp://lattes.cnpq.br/8801080897723883Brandstetter, Maria Carolina Gomes de OliveiraSattler, Miguel AloysioMorais, Ludmila Rodrigues dehttp://lattes.cnpq.br/6524317625011180Ochoa, Juliana Herlemann2022-07-06T21:30:38Z2022-07-06T21:30:38Z2010-09-24OCHOA, Juliana Herlemann. Análise do conforto ambiental em salas de aula da Universidade Federal de Goiás. 2010. 247 f. Dissertação (Mestrado em Geotecnia, Estruturas e Construção Civil) - Universidade Federal de Goiás, Goiânia, 2010.http://repositorio.bc.ufg.br/tede/handle/tede/12166ark:/38995/0013000007hbwProvide users good physical conditions in educational institutions is essential for the proper development of teaching and learning. This work deals with the verification in-loco of the environmental comfort of classrooms in two buildings with different architectural and construction techniques, that are part of the structure of the Federal University of Goiás. So the research aimed at exploring these buildings in order to identify the peculiarities of its thermal, acoustic and light performance which are being influenced by the technologies adopted and the physical conformation of the same. The technical data collected were analyzed by type of comfort. In lighting comfort, measurements were carried out near the solstices and equinoxes and the data collected were analyzed by means of ambient illuminance, uniformity coefficient and contribution of artificial light. The thermal comfort data collected were temperature and relative humidity for a period of approximately 11 months, which were assessed using the concept of comfort zone, degree-hours analysis and absolute maximum and minimum values. The acoustic measurements collected the sound pressure levels and occurred over a day of daily activities in both buildings. It was noted that there is an influence of the architectural elements of environmental comfort in buildings. Among other factors, one that can be highlighted is that despite having similar solar orientation, which is a comfort condition, the results of the environmental performance of each of the buildings were quite different. Parallel to these technical assessments were also done a periodic application of questionnaires to the users of the classroom, one per season, which sought to characterize the perception of these in relation to each of the types of comfort. Finally, a correlation was established between the technical data collected and perceptive. In most of cases, the opinions expressed by users were not consistent with the results evaluated by measurement techniques, thus demonstrating a difference between the comfort zone adopted and the actual user satisfaction of the buildings.Proporcionar aos usuários boas condições físicas nas instituições educacionais é determinante para o adequado desenvolvimento das atividades de ensino e aprendizado. Este trabalho trata da avaliação in loco do conforto ambiental de salas de aula de duas edificações com arquitetura e técnicas construtivas diferentes, que compõe a estrutura da Universidade Federal de Goiás. Desta maneira, a pesquisa objetiva explorar estas edificações buscando identificar, em cada uma delas, peculiaridades de seu desempenho térmico, acústico e lumínico, que estejam sendo influenciadas pelas tecnologias adotadas e pela conformação física das mesmas. Os dados técnicos levantados foram avaliados por tipologia de conforto. No conforto lumínico, realizaram-se medições próximas aos solstícios e equinócios e os dados coletados foram analisados pelas iluminâncias médias dos ambientes, coeficiente de uniformidade e contribuição da luz artificial. Os dados de conforto térmico coletados foram: temperatura e umidade relativa, por um período de aproximadamente 11 meses, os quais foram avaliados por meio do conceito de zona de conforto, análise graus-hora e valores máximos e mínimos absolutos. As medições acústicas coletaram os níveis de pressão sonora e ocorreram ao longo de um dia de atividades cotidianas, em ambas as edificações. Notou-se, que há uma influência dos elementos arquitetônicos no conforto ambiental das edificações. Entre outros fatores, um que pode ser destacado é que, apesar de possuírem orientação solar similar, que é um aspecto condicionante de conforto, os resultados do desempenho ambiental, de cada um dos edifícios, foram bastante diferenciados. Paralela a estas avaliações técnicas, foi também realizada uma aplicação periódica de questionários aos usuários das salas estudadas, sendo uma por estação do ano, que buscou caracterizar a percepção destes, em relação a cada uma das tipologias de conforto. Finalmente, foi estabelecida uma correlação entre os dados técnicos levantados e os perceptivos. Em parte dos casos, as opiniões expressadas pelos usuários não foram condizentes com os resultados avaliados por meio das medições técnicas, demonstrando assim uma divergência entre a zona de conforto adotada e a real satisfação dos usuários das edificações.Submitted by Jaqueline Silva (jtas29@gmail.com) on 2022-07-06T21:30:01Z No. of bitstreams: 2 Dissertação - Juliana Herlemann Ochoa - 2010.pdf: 15913457 bytes, checksum: 5213d8470065fa2c192bfa70cbb4313a (MD5) license_rdf: 805 bytes, checksum: 4460e5956bc1d1639be9ae6146a50347 (MD5)Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2022-07-06T21:30:38Z (GMT) No. of bitstreams: 2 Dissertação - Juliana Herlemann Ochoa - 2010.pdf: 15913457 bytes, checksum: 5213d8470065fa2c192bfa70cbb4313a (MD5) license_rdf: 805 bytes, checksum: 4460e5956bc1d1639be9ae6146a50347 (MD5)Made available in DSpace on 2022-07-06T21:30:38Z (GMT). No. of bitstreams: 2 Dissertação - Juliana Herlemann Ochoa - 2010.pdf: 15913457 bytes, checksum: 5213d8470065fa2c192bfa70cbb4313a (MD5) license_rdf: 805 bytes, checksum: 4460e5956bc1d1639be9ae6146a50347 (MD5) Previous issue date: 2010-09-24Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPqporUniversidade Federal de GoiásPrograma de Pós-graduação em Geotecnia, Estruturas e Construção Civil (EEC)UFGBrasilEscola de Engenharia Civil e Ambiental - EECA (RG)Attribution-NonCommercial-NoDerivatives 4.0 Internationalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessUser's perceptionEnvironmental comfortUniversity BuildingsConforto ambientalEdificações escolares de nível superiorPercepção dos usuáriosENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVILAnálise do conforto ambiental em salas de aula da Universidade Federal de GoiásAnalysis of environmental comfort in classrooms at the Federal University of Goiasinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis6350050050050033970reponame:Repositório Institucional da UFGinstname:Universidade Federal de Goiás (UFG)instacron:UFGLICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://repositorio.bc.ufg.br/tede/bitstreams/10f9bad8-a970-4e7b-8309-dd637a36aeda/download8a4605be74aa9ea9d79846c1fba20a33MD51CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8805http://repositorio.bc.ufg.br/tede/bitstreams/f01012e1-634b-4cca-98b4-31c1a8bd1221/download4460e5956bc1d1639be9ae6146a50347MD52ORIGINALDissertação - Juliana Herlemann Ochoa - 2010.pdfDissertação - Juliana Herlemann Ochoa - 2010.pdfapplication/pdf15913457http://repositorio.bc.ufg.br/tede/bitstreams/00d2440a-6840-4135-8fa7-85e23ec3074c/download5213d8470065fa2c192bfa70cbb4313aMD53tede/121662022-07-06 18:30:38.934http://creativecommons.org/licenses/by-nc-nd/4.0/Attribution-NonCommercial-NoDerivatives 4.0 Internationalopen.accessoai:repositorio.bc.ufg.br:tede/12166http://repositorio.bc.ufg.br/tedeRepositório InstitucionalPUBhttp://repositorio.bc.ufg.br/oai/requesttasesdissertacoes.bc@ufg.bropendoar:2022-07-06T21:30:38Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)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
dc.title.pt_BR.fl_str_mv Análise do conforto ambiental em salas de aula da Universidade Federal de Goiás
dc.title.alternative.por.fl_str_mv Analysis of environmental comfort in classrooms at the Federal University of Goias
title Análise do conforto ambiental em salas de aula da Universidade Federal de Goiás
spellingShingle Análise do conforto ambiental em salas de aula da Universidade Federal de Goiás
Ochoa, Juliana Herlemann
User's perception
Environmental comfort
University Buildings
Conforto ambiental
Edificações escolares de nível superior
Percepção dos usuários
ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVIL
title_short Análise do conforto ambiental em salas de aula da Universidade Federal de Goiás
title_full Análise do conforto ambiental em salas de aula da Universidade Federal de Goiás
title_fullStr Análise do conforto ambiental em salas de aula da Universidade Federal de Goiás
title_full_unstemmed Análise do conforto ambiental em salas de aula da Universidade Federal de Goiás
title_sort Análise do conforto ambiental em salas de aula da Universidade Federal de Goiás
author Ochoa, Juliana Herlemann
author_facet Ochoa, Juliana Herlemann
author_role author
dc.contributor.advisor1.fl_str_mv Araújo, Daniel de Lima
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/8801080897723883
dc.contributor.referee1.fl_str_mv Brandstetter, Maria Carolina Gomes de Oliveira
dc.contributor.referee2.fl_str_mv Sattler, Miguel Aloysio
dc.contributor.referee3.fl_str_mv Morais, Ludmila Rodrigues de
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/6524317625011180
dc.contributor.author.fl_str_mv Ochoa, Juliana Herlemann
contributor_str_mv Araújo, Daniel de Lima
Brandstetter, Maria Carolina Gomes de Oliveira
Sattler, Miguel Aloysio
Morais, Ludmila Rodrigues de
dc.subject.eng.fl_str_mv User's perception
Environmental comfort
University Buildings
topic User's perception
Environmental comfort
University Buildings
Conforto ambiental
Edificações escolares de nível superior
Percepção dos usuários
ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVIL
dc.subject.por.fl_str_mv Conforto ambiental
Edificações escolares de nível superior
Percepção dos usuários
dc.subject.cnpq.fl_str_mv ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVIL
description Provide users good physical conditions in educational institutions is essential for the proper development of teaching and learning. This work deals with the verification in-loco of the environmental comfort of classrooms in two buildings with different architectural and construction techniques, that are part of the structure of the Federal University of Goiás. So the research aimed at exploring these buildings in order to identify the peculiarities of its thermal, acoustic and light performance which are being influenced by the technologies adopted and the physical conformation of the same. The technical data collected were analyzed by type of comfort. In lighting comfort, measurements were carried out near the solstices and equinoxes and the data collected were analyzed by means of ambient illuminance, uniformity coefficient and contribution of artificial light. The thermal comfort data collected were temperature and relative humidity for a period of approximately 11 months, which were assessed using the concept of comfort zone, degree-hours analysis and absolute maximum and minimum values. The acoustic measurements collected the sound pressure levels and occurred over a day of daily activities in both buildings. It was noted that there is an influence of the architectural elements of environmental comfort in buildings. Among other factors, one that can be highlighted is that despite having similar solar orientation, which is a comfort condition, the results of the environmental performance of each of the buildings were quite different. Parallel to these technical assessments were also done a periodic application of questionnaires to the users of the classroom, one per season, which sought to characterize the perception of these in relation to each of the types of comfort. Finally, a correlation was established between the technical data collected and perceptive. In most of cases, the opinions expressed by users were not consistent with the results evaluated by measurement techniques, thus demonstrating a difference between the comfort zone adopted and the actual user satisfaction of the buildings.
publishDate 2010
dc.date.issued.fl_str_mv 2010-09-24
dc.date.accessioned.fl_str_mv 2022-07-06T21:30:38Z
dc.date.available.fl_str_mv 2022-07-06T21:30:38Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv OCHOA, Juliana Herlemann. Análise do conforto ambiental em salas de aula da Universidade Federal de Goiás. 2010. 247 f. Dissertação (Mestrado em Geotecnia, Estruturas e Construção Civil) - Universidade Federal de Goiás, Goiânia, 2010.
dc.identifier.uri.fl_str_mv http://repositorio.bc.ufg.br/tede/handle/tede/12166
dc.identifier.dark.fl_str_mv ark:/38995/0013000007hbw
identifier_str_mv OCHOA, Juliana Herlemann. Análise do conforto ambiental em salas de aula da Universidade Federal de Goiás. 2010. 247 f. Dissertação (Mestrado em Geotecnia, Estruturas e Construção Civil) - Universidade Federal de Goiás, Goiânia, 2010.
ark:/38995/0013000007hbw
url http://repositorio.bc.ufg.br/tede/handle/tede/12166
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv 63
dc.relation.confidence.fl_str_mv 500
500
500
500
dc.relation.department.fl_str_mv 3
dc.relation.cnpq.fl_str_mv 397
dc.relation.sponsorship.fl_str_mv 0
dc.rights.driver.fl_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Attribution-NonCommercial-NoDerivatives 4.0 International
http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade Federal de Goiás
dc.publisher.program.fl_str_mv Programa de Pós-graduação em Geotecnia, Estruturas e Construção Civil (EEC)
dc.publisher.initials.fl_str_mv UFG
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Escola de Engenharia Civil e Ambiental - EECA (RG)
publisher.none.fl_str_mv Universidade Federal de Goiás
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFG
instname:Universidade Federal de Goiás (UFG)
instacron:UFG
instname_str Universidade Federal de Goiás (UFG)
instacron_str UFG
institution UFG
reponame_str Repositório Institucional da UFG
collection Repositório Institucional da UFG
bitstream.url.fl_str_mv http://repositorio.bc.ufg.br/tede/bitstreams/10f9bad8-a970-4e7b-8309-dd637a36aeda/download
http://repositorio.bc.ufg.br/tede/bitstreams/f01012e1-634b-4cca-98b4-31c1a8bd1221/download
http://repositorio.bc.ufg.br/tede/bitstreams/00d2440a-6840-4135-8fa7-85e23ec3074c/download
bitstream.checksum.fl_str_mv 8a4605be74aa9ea9d79846c1fba20a33
4460e5956bc1d1639be9ae6146a50347
5213d8470065fa2c192bfa70cbb4313a
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFG - Universidade Federal de Goiás (UFG)
repository.mail.fl_str_mv tasesdissertacoes.bc@ufg.br
_version_ 1811721435217920000