FACTORS THAT CAN INVALIDATE THE RESULTS OF GLYCEMIC LEVELS IN DOGS USING A PORTABLE GLUCOMETER
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Ciência animal brasileira (Online) |
Texto Completo: | https://revistas.ufg.br/vet/article/view/875 |
Resumo: | The portable glucometer is a very useful tool for the human or veterinary health care professionals to obtain information about the patient’s glycemic state. The equipment is easy to handle and still gives precise results, however there are some factors that can alter its accuracy. Those should be avoided, so that inadequate therapeutic decisions are not made and dangerous situations for the patient’s life do not pass unnoticed. The object of this trial was to show the main factors of risk that can alter the results obtained with a portable glucometer. For the study 53 canines were used. 17 did not have precise results because they presented low hematocrit, the amount of blood collected was not enough or either a part was over the test strip or still, the accomplishment of the test passed the 15 seconds recommended by the manufacturer. It was concluded that those factors are susceptible to happen when a portable glucometer is used, and that the results obtained in those situations are not accurate, therefore, when observing them during the accomplishment of a glucose exam, the test should be repeated. KEY WORDS: Accuracy, glycemia, glucose monitor. |
id |
UFG-7_e5af7780a58f133fe8392c470b938fc5 |
---|---|
oai_identifier_str |
oai:ojs.revistas.ufg.br:article/875 |
network_acronym_str |
UFG-7 |
network_name_str |
Ciência animal brasileira (Online) |
repository_id_str |
|
spelling |
FACTORS THAT CAN INVALIDATE THE RESULTS OF GLYCEMIC LEVELS IN DOGS USING A PORTABLE GLUCOMETERFATORES QUE PODEM INVALIDAR OS RESULTADOS DA MENSURAÇÃO DOS NÍVEIS GLICÊMICOS EM CÃES UTILIZANDO O GLICOSÍMETRO PORTÁTILThe portable glucometer is a very useful tool for the human or veterinary health care professionals to obtain information about the patient’s glycemic state. The equipment is easy to handle and still gives precise results, however there are some factors that can alter its accuracy. Those should be avoided, so that inadequate therapeutic decisions are not made and dangerous situations for the patient’s life do not pass unnoticed. The object of this trial was to show the main factors of risk that can alter the results obtained with a portable glucometer. For the study 53 canines were used. 17 did not have precise results because they presented low hematocrit, the amount of blood collected was not enough or either a part was over the test strip or still, the accomplishment of the test passed the 15 seconds recommended by the manufacturer. It was concluded that those factors are susceptible to happen when a portable glucometer is used, and that the results obtained in those situations are not accurate, therefore, when observing them during the accomplishment of a glucose exam, the test should be repeated. KEY WORDS: Accuracy, glycemia, glucose monitor.O glicosímetro portátil é uma ferramenta útil para os profissionais da área de saúde, seja humana ou veterinária, obterem informações relacionadas ao estado glicêmico dos seus pacientes. O aparelho é de fácil manuseio e ainda fornece resultados precisos, apesar da possiblidade de alguns fatores alterarem a sua acurácia. Tais fatores, portanto, devem ser evitados, para impedir que decisões terapêuticas inadequadas sejam tomadas e para que o paciente não seja exposto a situações de risco para sua saúde. Assim, neste trabalho relatam-se os principais fatores que podem alterar os resultados obtidos com um glicosímetro portátil, medinate estudo em que se utilizaram 53 animais da espécie canina. Desses, dezessete não tiveram resultados precisos, porque apresentavam baixo hematócrito, a quantidade de sangue coletado não foi suficiente ou uma parte ficou por cima da tira teste ou, ainda, a realização do teste ultrapassou os quinze segundos recomendados pelo fabricante. Conclui-se que esses fatores são passíveis de acontecerem quando se emprega o glicosímetro portátil e que os resultados alcançados nessas situações não são precisos. Diante disso, recomenda-se, ao se far um exame de glicose, repetir o teste. PALAVRAS-CHAVE: Acurácia, glicemia, monitor de glicose.Universidade Federal de Goiás2006-12-25info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionAvaliado por paresapplication/pdfhttps://revistas.ufg.br/vet/article/view/87510.5216/cab.v7i4.875Brazilian Animal Science/ Ciência Animal Brasileira; Vol. 7 No. 4 (2006); 447-454Ciência Animal Brasileira / Brazilian Animal Science; v. 7 n. 4 (2006); 447-4541809-68911518-2797reponame:Ciência animal brasileira (Online)instname:Universidade Federal de Goiás (UFG)instacron:UFGporhttps://revistas.ufg.br/vet/article/view/875/1014Aleixo, Grazielle Anahy de SousaCoelho, Maria Cristina de Oliveira CardosoGuimarães, Ana Luiza NevesAndrade, Moacir BezerraLopes Júnior, Clodomir GuedesSilva, Rafaella Alves de AraújoCavalcanti, Humberto Barrosinfo:eu-repo/semantics/openAccess2007-02-05T11:15:17Zoai:ojs.revistas.ufg.br:article/875Revistahttps://revistas.ufg.br/vetPUBhttps://revistas.ufg.br/vet/oai||revistacab@gmail.com1809-68911518-2797opendoar:2024-05-21T19:54:45.701401Ciência animal brasileira (Online) - Universidade Federal de Goiás (UFG)true |
dc.title.none.fl_str_mv |
FACTORS THAT CAN INVALIDATE THE RESULTS OF GLYCEMIC LEVELS IN DOGS USING A PORTABLE GLUCOMETER FATORES QUE PODEM INVALIDAR OS RESULTADOS DA MENSURAÇÃO DOS NÍVEIS GLICÊMICOS EM CÃES UTILIZANDO O GLICOSÍMETRO PORTÁTIL |
title |
FACTORS THAT CAN INVALIDATE THE RESULTS OF GLYCEMIC LEVELS IN DOGS USING A PORTABLE GLUCOMETER |
spellingShingle |
FACTORS THAT CAN INVALIDATE THE RESULTS OF GLYCEMIC LEVELS IN DOGS USING A PORTABLE GLUCOMETER Aleixo, Grazielle Anahy de Sousa |
title_short |
FACTORS THAT CAN INVALIDATE THE RESULTS OF GLYCEMIC LEVELS IN DOGS USING A PORTABLE GLUCOMETER |
title_full |
FACTORS THAT CAN INVALIDATE THE RESULTS OF GLYCEMIC LEVELS IN DOGS USING A PORTABLE GLUCOMETER |
title_fullStr |
FACTORS THAT CAN INVALIDATE THE RESULTS OF GLYCEMIC LEVELS IN DOGS USING A PORTABLE GLUCOMETER |
title_full_unstemmed |
FACTORS THAT CAN INVALIDATE THE RESULTS OF GLYCEMIC LEVELS IN DOGS USING A PORTABLE GLUCOMETER |
title_sort |
FACTORS THAT CAN INVALIDATE THE RESULTS OF GLYCEMIC LEVELS IN DOGS USING A PORTABLE GLUCOMETER |
author |
Aleixo, Grazielle Anahy de Sousa |
author_facet |
Aleixo, Grazielle Anahy de Sousa Coelho, Maria Cristina de Oliveira Cardoso Guimarães, Ana Luiza Neves Andrade, Moacir Bezerra Lopes Júnior, Clodomir Guedes Silva, Rafaella Alves de Araújo Cavalcanti, Humberto Barros |
author_role |
author |
author2 |
Coelho, Maria Cristina de Oliveira Cardoso Guimarães, Ana Luiza Neves Andrade, Moacir Bezerra Lopes Júnior, Clodomir Guedes Silva, Rafaella Alves de Araújo Cavalcanti, Humberto Barros |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Aleixo, Grazielle Anahy de Sousa Coelho, Maria Cristina de Oliveira Cardoso Guimarães, Ana Luiza Neves Andrade, Moacir Bezerra Lopes Júnior, Clodomir Guedes Silva, Rafaella Alves de Araújo Cavalcanti, Humberto Barros |
description |
The portable glucometer is a very useful tool for the human or veterinary health care professionals to obtain information about the patient’s glycemic state. The equipment is easy to handle and still gives precise results, however there are some factors that can alter its accuracy. Those should be avoided, so that inadequate therapeutic decisions are not made and dangerous situations for the patient’s life do not pass unnoticed. The object of this trial was to show the main factors of risk that can alter the results obtained with a portable glucometer. For the study 53 canines were used. 17 did not have precise results because they presented low hematocrit, the amount of blood collected was not enough or either a part was over the test strip or still, the accomplishment of the test passed the 15 seconds recommended by the manufacturer. It was concluded that those factors are susceptible to happen when a portable glucometer is used, and that the results obtained in those situations are not accurate, therefore, when observing them during the accomplishment of a glucose exam, the test should be repeated. KEY WORDS: Accuracy, glycemia, glucose monitor. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006-12-25 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Avaliado por pares |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://revistas.ufg.br/vet/article/view/875 10.5216/cab.v7i4.875 |
url |
https://revistas.ufg.br/vet/article/view/875 |
identifier_str_mv |
10.5216/cab.v7i4.875 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
https://revistas.ufg.br/vet/article/view/875/1014 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Goiás |
publisher.none.fl_str_mv |
Universidade Federal de Goiás |
dc.source.none.fl_str_mv |
Brazilian Animal Science/ Ciência Animal Brasileira; Vol. 7 No. 4 (2006); 447-454 Ciência Animal Brasileira / Brazilian Animal Science; v. 7 n. 4 (2006); 447-454 1809-6891 1518-2797 reponame:Ciência animal brasileira (Online) instname:Universidade Federal de Goiás (UFG) instacron:UFG |
instname_str |
Universidade Federal de Goiás (UFG) |
instacron_str |
UFG |
institution |
UFG |
reponame_str |
Ciência animal brasileira (Online) |
collection |
Ciência animal brasileira (Online) |
repository.name.fl_str_mv |
Ciência animal brasileira (Online) - Universidade Federal de Goiás (UFG) |
repository.mail.fl_str_mv |
||revistacab@gmail.com |
_version_ |
1799874782755291136 |