Hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) operated with an adopted hydraulic retention time (HRT) of 12 hours

Detalhes bibliográficos
Autor(a) principal: Lourenço, Aguinaldo Menegassi Pereira
Data de Publicação: 2009
Outros Autores: Campos, Cláudio Milton Montenegro
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UFLA
Texto Completo: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1413-70542009000400027
http://repositorio.ufla.br/jspui/handle/1/7009
Resumo: The present research was carried out in the Laboratory of Water Analysis at the Engineering Department at Federal University of Lavras (LWAED-UFLA), in order to evaluate the hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) that was continuously fed with liquid effluent from swine manure with solid separation over 2mm. The hydrodynamic parameters were determined by a tracer study, under hydraulic retention time (HRT) of 12 hours, using Lithium Chloride (LiCl) as a tracer. The system was monitored periodically through physical analysis of samples collected at UASB, during the steady-state operational conditions. The physical-chemical analyses were accomplished using a flame photometry. The operational average temperature in the UASB reactor was 23.9ºC .The UASB hydrodynamic parameters determined were: average residence time (<img src="/img/revistas/cagro/v33n4/t4_barra.gif" align="absmiddle">) of 38.3 h, number of dispersion d= 0.27, and the flow type was characterized as dispersed flow of great intensity. This research is of great importance due to the fact that the scaling-up of biological reactors is based on the hydrodynamic behavior, through which the bacterial kinetic is directly influenced, as reported by Saleh (2004).
id UFLA_8a55610b426674bbec78027d7659c3a2
oai_identifier_str oai:localhost:1/7009
network_acronym_str UFLA
network_name_str Repositório Institucional da UFLA
repository_id_str
spelling Hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) operated with an adopted hydraulic retention time (HRT) of 12 hoursComportamento hidrodinâmico de um reator anaeróbio de manta de lodo (UASB) em escala de bancada operando com tempo de detenção hidráulica (TDH) de 12 horasHydrodynamicHydraulic retention timeTracer studiesUASB reactorHidrodinâmicaTempo de detenção hidráulicaTraçadorReator UASBThe present research was carried out in the Laboratory of Water Analysis at the Engineering Department at Federal University of Lavras (LWAED-UFLA), in order to evaluate the hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) that was continuously fed with liquid effluent from swine manure with solid separation over 2mm. The hydrodynamic parameters were determined by a tracer study, under hydraulic retention time (HRT) of 12 hours, using Lithium Chloride (LiCl) as a tracer. The system was monitored periodically through physical analysis of samples collected at UASB, during the steady-state operational conditions. The physical-chemical analyses were accomplished using a flame photometry. The operational average temperature in the UASB reactor was 23.9ºC .The UASB hydrodynamic parameters determined were: average residence time (<img src="/img/revistas/cagro/v33n4/t4_barra.gif" align="absmiddle">) of 38.3 h, number of dispersion d= 0.27, and the flow type was characterized as dispersed flow of great intensity. This research is of great importance due to the fact that the scaling-up of biological reactors is based on the hydrodynamic behavior, through which the bacterial kinetic is directly influenced, as reported by Saleh (2004).A presente pesquisa foi realizada no Laboratório de Análise de Água do Departamento de Engenharia na Universidade Federal de Lavras (LAADEG-UFLA), para avaliar o comportamento hidrodinâmico de um reator anaeróbio de manta de lodo (UASB), em escala laboratorial, alimentado continuamente com água residuária do confinamento de suínos isenta de sólidos com diâmetro acima de 2 mm. Na avaliação dos parâmetros hidrodinâmicos foi utilizado o cloreto de lítio (LiCl) como traçador, sob tempo de detenção hidráulica (TDH) de 12 horas. O monitoramento foi realizado, quando o reator UASB apresentava condições permanentes "steady-state". As análises físico-químicas foram realizadas em fotômetro de chama, de amostras retiradas na saída da unidade de tratamento, em intervalos constantes de tempo. A temperatura média operacional do reator UASB foi de 23,9ºC. Os parâmetros hidrodinâmicos do reator UASB, determinados por meio da avaliação foram: tempo médio de residência = 38,3 h, número de dispersão d= 0,27 e tipo de fluxo, o qual foi caracterizado como disperso de grande intensidade. A pesquisa se reveste de importância, uma vez que o escalonamento "scale-up" de reatores biológicos, se baseia diretamente nos comportamentos hidrodinâmicos do mesmo, em função da elevada influência que os referidos comportamentos possuem sobre a cinética bacteriana, conforme relatado por Saleh (2004).Editora da Universidade Federal de Lavras2009-08-012015-04-30T13:35:20Z2015-04-30T13:35:20Z2015-04-30info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S1413-70542009000400027LOURENCO, A. M. P.; CAMPOS, C. M. M. Hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) operated with an adopted hydraulic retention time (HRT) of 12 hours. Ciência e Agrotecnologia, Lavras, v. 33, n. 4, p. 1139-1144, jul./ago. 2009.http://repositorio.ufla.br/jspui/handle/1/7009Ciência e Agrotecnologia v.33 n.4 2009reponame:Repositório Institucional da UFLAinstname:Universidade Federal de Lavras (UFLA)instacron:UFLALourenço, Aguinaldo Menegassi PereiraCampos, Cláudio Milton Montenegroenginfo:eu-repo/semantics/openAccess2016-06-28T14:30:42Zoai:localhost:1/7009Repositório InstitucionalPUBhttp://repositorio.ufla.br/oai/requestnivaldo@ufla.br || repositorio.biblioteca@ufla.bropendoar:2016-06-28T14:30:42Repositório Institucional da UFLA - Universidade Federal de Lavras (UFLA)false
dc.title.none.fl_str_mv Hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) operated with an adopted hydraulic retention time (HRT) of 12 hours
Comportamento hidrodinâmico de um reator anaeróbio de manta de lodo (UASB) em escala de bancada operando com tempo de detenção hidráulica (TDH) de 12 horas
title Hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) operated with an adopted hydraulic retention time (HRT) of 12 hours
spellingShingle Hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) operated with an adopted hydraulic retention time (HRT) of 12 hours
Lourenço, Aguinaldo Menegassi Pereira
Hydrodynamic
Hydraulic retention time
Tracer studies
UASB reactor
Hidrodinâmica
Tempo de detenção hidráulica
Traçador
Reator UASB
title_short Hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) operated with an adopted hydraulic retention time (HRT) of 12 hours
title_full Hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) operated with an adopted hydraulic retention time (HRT) of 12 hours
title_fullStr Hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) operated with an adopted hydraulic retention time (HRT) of 12 hours
title_full_unstemmed Hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) operated with an adopted hydraulic retention time (HRT) of 12 hours
title_sort Hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) operated with an adopted hydraulic retention time (HRT) of 12 hours
author Lourenço, Aguinaldo Menegassi Pereira
author_facet Lourenço, Aguinaldo Menegassi Pereira
Campos, Cláudio Milton Montenegro
author_role author
author2 Campos, Cláudio Milton Montenegro
author2_role author
dc.contributor.author.fl_str_mv Lourenço, Aguinaldo Menegassi Pereira
Campos, Cláudio Milton Montenegro
dc.subject.por.fl_str_mv Hydrodynamic
Hydraulic retention time
Tracer studies
UASB reactor
Hidrodinâmica
Tempo de detenção hidráulica
Traçador
Reator UASB
topic Hydrodynamic
Hydraulic retention time
Tracer studies
UASB reactor
Hidrodinâmica
Tempo de detenção hidráulica
Traçador
Reator UASB
description The present research was carried out in the Laboratory of Water Analysis at the Engineering Department at Federal University of Lavras (LWAED-UFLA), in order to evaluate the hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) that was continuously fed with liquid effluent from swine manure with solid separation over 2mm. The hydrodynamic parameters were determined by a tracer study, under hydraulic retention time (HRT) of 12 hours, using Lithium Chloride (LiCl) as a tracer. The system was monitored periodically through physical analysis of samples collected at UASB, during the steady-state operational conditions. The physical-chemical analyses were accomplished using a flame photometry. The operational average temperature in the UASB reactor was 23.9ºC .The UASB hydrodynamic parameters determined were: average residence time (<img src="/img/revistas/cagro/v33n4/t4_barra.gif" align="absmiddle">) of 38.3 h, number of dispersion d= 0.27, and the flow type was characterized as dispersed flow of great intensity. This research is of great importance due to the fact that the scaling-up of biological reactors is based on the hydrodynamic behavior, through which the bacterial kinetic is directly influenced, as reported by Saleh (2004).
publishDate 2009
dc.date.none.fl_str_mv 2009-08-01
2015-04-30T13:35:20Z
2015-04-30T13:35:20Z
2015-04-30
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1413-70542009000400027
LOURENCO, A. M. P.; CAMPOS, C. M. M. Hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) operated with an adopted hydraulic retention time (HRT) of 12 hours. Ciência e Agrotecnologia, Lavras, v. 33, n. 4, p. 1139-1144, jul./ago. 2009.
http://repositorio.ufla.br/jspui/handle/1/7009
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1413-70542009000400027
http://repositorio.ufla.br/jspui/handle/1/7009
identifier_str_mv LOURENCO, A. M. P.; CAMPOS, C. M. M. Hydrodynamic behavior of a lab-scale upflow anaerobic sludge blanket reactor (UASB) operated with an adopted hydraulic retention time (HRT) of 12 hours. Ciência e Agrotecnologia, Lavras, v. 33, n. 4, p. 1139-1144, jul./ago. 2009.
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Editora da Universidade Federal de Lavras
publisher.none.fl_str_mv Editora da Universidade Federal de Lavras
dc.source.none.fl_str_mv Ciência e Agrotecnologia v.33 n.4 2009
reponame:Repositório Institucional da UFLA
instname:Universidade Federal de Lavras (UFLA)
instacron:UFLA
instname_str Universidade Federal de Lavras (UFLA)
instacron_str UFLA
institution UFLA
reponame_str Repositório Institucional da UFLA
collection Repositório Institucional da UFLA
repository.name.fl_str_mv Repositório Institucional da UFLA - Universidade Federal de Lavras (UFLA)
repository.mail.fl_str_mv nivaldo@ufla.br || repositorio.biblioteca@ufla.br
_version_ 1784550202507526144