Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UFLA |
Texto Completo: | http://repositorio.ufla.br/jspui/handle/1/49661 |
Resumo: | Pilot-scale test stations make it possible to obtain reliable and comparable results applicable to full–scale systems by conforming to specified proportional limits. Therefore, in this study, normal and frictional pressures were evaluated in a pilot-scale test station composed of a slender cylinder silo using maize, a free-flowing product, as the stored product. Temporal effects were analyzed and verified during filling, static, and discharge conditions. The maximum normal and frictional pressures were also evaluated. The results were compared with ISO 11697: 1995. During filling, accommodation peaks occurred only in the α: 30° hopper. In general, normal pressures were higher for the flat bottom whereas higher frictional pressures occurred for the 30° hopper. The maximum experimental pressures (normal and frictional) were lower than those provided by ISO 11697. Therefore, it is concluded that the coefficients used in the ISO standard are sufficient to promote safety in silo projects. |
id |
UFLA_a68482005bb80da30d7c8c8ace37024f |
---|---|
oai_identifier_str |
oai:localhost:1/49661 |
network_acronym_str |
UFLA |
network_name_str |
Repositório Institucional da UFLA |
repository_id_str |
|
spelling |
Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697Funnel flowNormal pressuresFrictional pressuresTest siloFluxo de funilPressões normaisPressões de atritoPilot-scale test stations make it possible to obtain reliable and comparable results applicable to full–scale systems by conforming to specified proportional limits. Therefore, in this study, normal and frictional pressures were evaluated in a pilot-scale test station composed of a slender cylinder silo using maize, a free-flowing product, as the stored product. Temporal effects were analyzed and verified during filling, static, and discharge conditions. The maximum normal and frictional pressures were also evaluated. The results were compared with ISO 11697: 1995. During filling, accommodation peaks occurred only in the α: 30° hopper. In general, normal pressures were higher for the flat bottom whereas higher frictional pressures occurred for the 30° hopper. The maximum experimental pressures (normal and frictional) were lower than those provided by ISO 11697. Therefore, it is concluded that the coefficients used in the ISO standard are sufficient to promote safety in silo projects.Associação Brasileira de Engenharia Agrícola2022-04-01T20:46:17Z2022-04-01T20:46:17Z2011-11info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfGANDIA, R. M. et al. Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697. Engenharia Agrícola, Jaboticabal, v. 41, n. 6, p. 576-590, nov./dec. 2021.http://repositorio.ufla.br/jspui/handle/1/49661Engenharia Agrícolareponame:Repositório Institucional da UFLAinstname:Universidade Federal de Lavras (UFLA)instacron:UFLAAttribution 4.0 Internationalhttp://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessGandia, Rômulo M.Oliveira Júnior, Estácio A. deGomes, Francisco C.Paula, Wisner C. deDornelas, Karoline C.eng2023-05-03T11:44:40Zoai:localhost:1/49661Repositório InstitucionalPUBhttp://repositorio.ufla.br/oai/requestnivaldo@ufla.br || repositorio.biblioteca@ufla.bropendoar:2023-05-03T11:44:40Repositório Institucional da UFLA - Universidade Federal de Lavras (UFLA)false |
dc.title.none.fl_str_mv |
Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697 |
title |
Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697 |
spellingShingle |
Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697 Gandia, Rômulo M. Funnel flow Normal pressures Frictional pressures Test silo Fluxo de funil Pressões normais Pressões de atrito |
title_short |
Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697 |
title_full |
Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697 |
title_fullStr |
Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697 |
title_full_unstemmed |
Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697 |
title_sort |
Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697 |
author |
Gandia, Rômulo M. |
author_facet |
Gandia, Rômulo M. Oliveira Júnior, Estácio A. de Gomes, Francisco C. Paula, Wisner C. de Dornelas, Karoline C. |
author_role |
author |
author2 |
Oliveira Júnior, Estácio A. de Gomes, Francisco C. Paula, Wisner C. de Dornelas, Karoline C. |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Gandia, Rômulo M. Oliveira Júnior, Estácio A. de Gomes, Francisco C. Paula, Wisner C. de Dornelas, Karoline C. |
dc.subject.por.fl_str_mv |
Funnel flow Normal pressures Frictional pressures Test silo Fluxo de funil Pressões normais Pressões de atrito |
topic |
Funnel flow Normal pressures Frictional pressures Test silo Fluxo de funil Pressões normais Pressões de atrito |
description |
Pilot-scale test stations make it possible to obtain reliable and comparable results applicable to full–scale systems by conforming to specified proportional limits. Therefore, in this study, normal and frictional pressures were evaluated in a pilot-scale test station composed of a slender cylinder silo using maize, a free-flowing product, as the stored product. Temporal effects were analyzed and verified during filling, static, and discharge conditions. The maximum normal and frictional pressures were also evaluated. The results were compared with ISO 11697: 1995. During filling, accommodation peaks occurred only in the α: 30° hopper. In general, normal pressures were higher for the flat bottom whereas higher frictional pressures occurred for the 30° hopper. The maximum experimental pressures (normal and frictional) were lower than those provided by ISO 11697. Therefore, it is concluded that the coefficients used in the ISO standard are sufficient to promote safety in silo projects. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011-11 2022-04-01T20:46:17Z 2022-04-01T20:46:17Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
GANDIA, R. M. et al. Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697. Engenharia Agrícola, Jaboticabal, v. 41, n. 6, p. 576-590, nov./dec. 2021. http://repositorio.ufla.br/jspui/handle/1/49661 |
identifier_str_mv |
GANDIA, R. M. et al. Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697. Engenharia Agrícola, Jaboticabal, v. 41, n. 6, p. 576-590, nov./dec. 2021. |
url |
http://repositorio.ufla.br/jspui/handle/1/49661 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
Attribution 4.0 International http://creativecommons.org/licenses/by/4.0/ info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Attribution 4.0 International http://creativecommons.org/licenses/by/4.0/ |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Engenharia Agrícola |
publisher.none.fl_str_mv |
Associação Brasileira de Engenharia Agrícola |
dc.source.none.fl_str_mv |
Engenharia Agrícola reponame:Repositório Institucional da UFLA instname:Universidade Federal de Lavras (UFLA) instacron:UFLA |
instname_str |
Universidade Federal de Lavras (UFLA) |
instacron_str |
UFLA |
institution |
UFLA |
reponame_str |
Repositório Institucional da UFLA |
collection |
Repositório Institucional da UFLA |
repository.name.fl_str_mv |
Repositório Institucional da UFLA - Universidade Federal de Lavras (UFLA) |
repository.mail.fl_str_mv |
nivaldo@ufla.br || repositorio.biblioteca@ufla.br |
_version_ |
1815439287351508992 |