Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697

Detalhes bibliográficos
Autor(a) principal: Gandia, Rômulo M.
Data de Publicação: 2011
Outros Autores: Oliveira Júnior, Estácio A. de, Gomes, Francisco C., Paula, Wisner C. de, Dornelas, Karoline C.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UFLA
Texto Completo: http://repositorio.ufla.br/jspui/handle/1/49661
Resumo: Pilot-scale test stations make it possible to obtain reliable and comparable results applicable to full–scale systems by conforming to specified proportional limits. Therefore, in this study, normal and frictional pressures were evaluated in a pilot-scale test station composed of a slender cylinder silo using maize, a free-flowing product, as the stored product. Temporal effects were analyzed and verified during filling, static, and discharge conditions. The maximum normal and frictional pressures were also evaluated. The results were compared with ISO 11697: 1995. During filling, accommodation peaks occurred only in the α: 30° hopper. In general, normal pressures were higher for the flat bottom whereas higher frictional pressures occurred for the 30° hopper. The maximum experimental pressures (normal and frictional) were lower than those provided by ISO 11697. Therefore, it is concluded that the coefficients used in the ISO standard are sufficient to promote safety in silo projects.
id UFLA_a68482005bb80da30d7c8c8ace37024f
oai_identifier_str oai:localhost:1/49661
network_acronym_str UFLA
network_name_str Repositório Institucional da UFLA
repository_id_str
spelling Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697Funnel flowNormal pressuresFrictional pressuresTest siloFluxo de funilPressões normaisPressões de atritoPilot-scale test stations make it possible to obtain reliable and comparable results applicable to full–scale systems by conforming to specified proportional limits. Therefore, in this study, normal and frictional pressures were evaluated in a pilot-scale test station composed of a slender cylinder silo using maize, a free-flowing product, as the stored product. Temporal effects were analyzed and verified during filling, static, and discharge conditions. The maximum normal and frictional pressures were also evaluated. The results were compared with ISO 11697: 1995. During filling, accommodation peaks occurred only in the α: 30° hopper. In general, normal pressures were higher for the flat bottom whereas higher frictional pressures occurred for the 30° hopper. The maximum experimental pressures (normal and frictional) were lower than those provided by ISO 11697. Therefore, it is concluded that the coefficients used in the ISO standard are sufficient to promote safety in silo projects.Associação Brasileira de Engenharia Agrícola2022-04-01T20:46:17Z2022-04-01T20:46:17Z2011-11info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfGANDIA, R. M. et al. Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697. Engenharia Agrícola, Jaboticabal, v. 41, n. 6, p. 576-590, nov./dec. 2021.http://repositorio.ufla.br/jspui/handle/1/49661Engenharia Agrícolareponame:Repositório Institucional da UFLAinstname:Universidade Federal de Lavras (UFLA)instacron:UFLAAttribution 4.0 Internationalhttp://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessGandia, Rômulo M.Oliveira Júnior, Estácio A. deGomes, Francisco C.Paula, Wisner C. deDornelas, Karoline C.eng2023-05-03T11:44:40Zoai:localhost:1/49661Repositório InstitucionalPUBhttp://repositorio.ufla.br/oai/requestnivaldo@ufla.br || repositorio.biblioteca@ufla.bropendoar:2023-05-03T11:44:40Repositório Institucional da UFLA - Universidade Federal de Lavras (UFLA)false
dc.title.none.fl_str_mv Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697
title Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697
spellingShingle Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697
Gandia, Rômulo M.
Funnel flow
Normal pressures
Frictional pressures
Test silo
Fluxo de funil
Pressões normais
Pressões de atrito
title_short Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697
title_full Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697
title_fullStr Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697
title_full_unstemmed Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697
title_sort Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697
author Gandia, Rômulo M.
author_facet Gandia, Rômulo M.
Oliveira Júnior, Estácio A. de
Gomes, Francisco C.
Paula, Wisner C. de
Dornelas, Karoline C.
author_role author
author2 Oliveira Júnior, Estácio A. de
Gomes, Francisco C.
Paula, Wisner C. de
Dornelas, Karoline C.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Gandia, Rômulo M.
Oliveira Júnior, Estácio A. de
Gomes, Francisco C.
Paula, Wisner C. de
Dornelas, Karoline C.
dc.subject.por.fl_str_mv Funnel flow
Normal pressures
Frictional pressures
Test silo
Fluxo de funil
Pressões normais
Pressões de atrito
topic Funnel flow
Normal pressures
Frictional pressures
Test silo
Fluxo de funil
Pressões normais
Pressões de atrito
description Pilot-scale test stations make it possible to obtain reliable and comparable results applicable to full–scale systems by conforming to specified proportional limits. Therefore, in this study, normal and frictional pressures were evaluated in a pilot-scale test station composed of a slender cylinder silo using maize, a free-flowing product, as the stored product. Temporal effects were analyzed and verified during filling, static, and discharge conditions. The maximum normal and frictional pressures were also evaluated. The results were compared with ISO 11697: 1995. During filling, accommodation peaks occurred only in the α: 30° hopper. In general, normal pressures were higher for the flat bottom whereas higher frictional pressures occurred for the 30° hopper. The maximum experimental pressures (normal and frictional) were lower than those provided by ISO 11697. Therefore, it is concluded that the coefficients used in the ISO standard are sufficient to promote safety in silo projects.
publishDate 2011
dc.date.none.fl_str_mv 2011-11
2022-04-01T20:46:17Z
2022-04-01T20:46:17Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv GANDIA, R. M. et al. Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697. Engenharia Agrícola, Jaboticabal, v. 41, n. 6, p. 576-590, nov./dec. 2021.
http://repositorio.ufla.br/jspui/handle/1/49661
identifier_str_mv GANDIA, R. M. et al. Experimental pressures exerted by maize in slender cylindrical silo: comparison with ISO 11697. Engenharia Agrícola, Jaboticabal, v. 41, n. 6, p. 576-590, nov./dec. 2021.
url http://repositorio.ufla.br/jspui/handle/1/49661
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv Attribution 4.0 International
http://creativecommons.org/licenses/by/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Attribution 4.0 International
http://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Associação Brasileira de Engenharia Agrícola
publisher.none.fl_str_mv Associação Brasileira de Engenharia Agrícola
dc.source.none.fl_str_mv Engenharia Agrícola
reponame:Repositório Institucional da UFLA
instname:Universidade Federal de Lavras (UFLA)
instacron:UFLA
instname_str Universidade Federal de Lavras (UFLA)
instacron_str UFLA
institution UFLA
reponame_str Repositório Institucional da UFLA
collection Repositório Institucional da UFLA
repository.name.fl_str_mv Repositório Institucional da UFLA - Universidade Federal de Lavras (UFLA)
repository.mail.fl_str_mv nivaldo@ufla.br || repositorio.biblioteca@ufla.br
_version_ 1815439287351508992