Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UFLA |
Texto Completo: | http://repositorio.ufla.br/jspui/handle/1/55401 |
Resumo: | In this study, we aimed to assess the spatial variability of microclimate inside a closed compost-bedded pack barn (CBP) with a negative ventilation system during summer and winter. The research was carried out in a CBP located in the Zona da Mata region, Minas Gerais, Brazil. For each of the stations analyzed, the following environmental mean variables observed inside a CBP were measured: air dry-bulb temperature (tdb), air relative humidity (RH), and windspeed, Temperature-Humidity index, and specific enthalpy. The kriging maps showed that the most critical housing conditions in the thermal environment were found, mainly, from the central part of the CBP, close to the exhaust fans. The analyses also pointed out that the system presented temperature gradients along the length, up to 3°C. During the summer afternoon, the entire region of the CBP was in a discomfort situation (tdb>26°C; RH>75%). During the winter, the measured environmental data remained within the comfort zone throughout the facility. However, probably due to the lack of thermal insulation of the material used to close the sides of the CBP, it did not allow spatial thermal uniformity for both seasons. It was also inefficient to keep the animals within the comfort zone for lactating cattle during the critical summer period. |
id |
UFLA_cb40becd1d7a99548645244e25284294 |
---|---|
oai_identifier_str |
oai:localhost:1/55401 |
network_acronym_str |
UFLA |
network_name_str |
Repositório Institucional da UFLA |
repository_id_str |
|
spelling |
Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel coolingAnimal welfareCompost barnsDairy cattleEvaporative coolingHeat stressModel-based geostatisticsIn this study, we aimed to assess the spatial variability of microclimate inside a closed compost-bedded pack barn (CBP) with a negative ventilation system during summer and winter. The research was carried out in a CBP located in the Zona da Mata region, Minas Gerais, Brazil. For each of the stations analyzed, the following environmental mean variables observed inside a CBP were measured: air dry-bulb temperature (tdb), air relative humidity (RH), and windspeed, Temperature-Humidity index, and specific enthalpy. The kriging maps showed that the most critical housing conditions in the thermal environment were found, mainly, from the central part of the CBP, close to the exhaust fans. The analyses also pointed out that the system presented temperature gradients along the length, up to 3°C. During the summer afternoon, the entire region of the CBP was in a discomfort situation (tdb>26°C; RH>75%). During the winter, the measured environmental data remained within the comfort zone throughout the facility. However, probably due to the lack of thermal insulation of the material used to close the sides of the CBP, it did not allow spatial thermal uniformity for both seasons. It was also inefficient to keep the animals within the comfort zone for lactating cattle during the critical summer period.2022-11-03T20:11:48Z2022-11-03T20:11:48Z2022info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfANDRADE, R. R. et al. Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling. Anais da Academia Brasileira de Ciências, [S.l.], v. 9, n. 3, 2022.http://repositorio.ufla.br/jspui/handle/1/55401Anais da Academia Brasileira de Ciênciasreponame:Repositório Institucional da UFLAinstname:Universidade Federal de Lavras (UFLA)instacron:UFLAAttribution 4.0 Internationalhttp://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessAndrade, Rafaella R.Tinôco, Ilda de Fátima F.Damasceno, Flávio A.Ferraz, Gabriel A. S.Freitas, Letícia Cibele S. R.Ferreira, Cecília de Fátima S.Barbari, MatteoTeles Junior, Carlos G. S.eng2023-05-03T11:17:15Zoai:localhost:1/55401Repositório InstitucionalPUBhttp://repositorio.ufla.br/oai/requestnivaldo@ufla.br || repositorio.biblioteca@ufla.bropendoar:2023-05-03T11:17:15Repositório Institucional da UFLA - Universidade Federal de Lavras (UFLA)false |
dc.title.none.fl_str_mv |
Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling |
title |
Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling |
spellingShingle |
Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling Andrade, Rafaella R. Animal welfare Compost barns Dairy cattle Evaporative cooling Heat stress Model-based geostatistics |
title_short |
Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling |
title_full |
Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling |
title_fullStr |
Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling |
title_full_unstemmed |
Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling |
title_sort |
Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling |
author |
Andrade, Rafaella R. |
author_facet |
Andrade, Rafaella R. Tinôco, Ilda de Fátima F. Damasceno, Flávio A. Ferraz, Gabriel A. S. Freitas, Letícia Cibele S. R. Ferreira, Cecília de Fátima S. Barbari, Matteo Teles Junior, Carlos G. S. |
author_role |
author |
author2 |
Tinôco, Ilda de Fátima F. Damasceno, Flávio A. Ferraz, Gabriel A. S. Freitas, Letícia Cibele S. R. Ferreira, Cecília de Fátima S. Barbari, Matteo Teles Junior, Carlos G. S. |
author2_role |
author author author author author author author |
dc.contributor.author.fl_str_mv |
Andrade, Rafaella R. Tinôco, Ilda de Fátima F. Damasceno, Flávio A. Ferraz, Gabriel A. S. Freitas, Letícia Cibele S. R. Ferreira, Cecília de Fátima S. Barbari, Matteo Teles Junior, Carlos G. S. |
dc.subject.por.fl_str_mv |
Animal welfare Compost barns Dairy cattle Evaporative cooling Heat stress Model-based geostatistics |
topic |
Animal welfare Compost barns Dairy cattle Evaporative cooling Heat stress Model-based geostatistics |
description |
In this study, we aimed to assess the spatial variability of microclimate inside a closed compost-bedded pack barn (CBP) with a negative ventilation system during summer and winter. The research was carried out in a CBP located in the Zona da Mata region, Minas Gerais, Brazil. For each of the stations analyzed, the following environmental mean variables observed inside a CBP were measured: air dry-bulb temperature (tdb), air relative humidity (RH), and windspeed, Temperature-Humidity index, and specific enthalpy. The kriging maps showed that the most critical housing conditions in the thermal environment were found, mainly, from the central part of the CBP, close to the exhaust fans. The analyses also pointed out that the system presented temperature gradients along the length, up to 3°C. During the summer afternoon, the entire region of the CBP was in a discomfort situation (tdb>26°C; RH>75%). During the winter, the measured environmental data remained within the comfort zone throughout the facility. However, probably due to the lack of thermal insulation of the material used to close the sides of the CBP, it did not allow spatial thermal uniformity for both seasons. It was also inefficient to keep the animals within the comfort zone for lactating cattle during the critical summer period. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-11-03T20:11:48Z 2022-11-03T20:11:48Z 2022 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
ANDRADE, R. R. et al. Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling. Anais da Academia Brasileira de Ciências, [S.l.], v. 9, n. 3, 2022. http://repositorio.ufla.br/jspui/handle/1/55401 |
identifier_str_mv |
ANDRADE, R. R. et al. Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling. Anais da Academia Brasileira de Ciências, [S.l.], v. 9, n. 3, 2022. |
url |
http://repositorio.ufla.br/jspui/handle/1/55401 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
Attribution 4.0 International http://creativecommons.org/licenses/by/4.0/ info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Attribution 4.0 International http://creativecommons.org/licenses/by/4.0/ |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
Anais da Academia Brasileira de Ciências reponame:Repositório Institucional da UFLA instname:Universidade Federal de Lavras (UFLA) instacron:UFLA |
instname_str |
Universidade Federal de Lavras (UFLA) |
instacron_str |
UFLA |
institution |
UFLA |
reponame_str |
Repositório Institucional da UFLA |
collection |
Repositório Institucional da UFLA |
repository.name.fl_str_mv |
Repositório Institucional da UFLA - Universidade Federal de Lavras (UFLA) |
repository.mail.fl_str_mv |
nivaldo@ufla.br || repositorio.biblioteca@ufla.br |
_version_ |
1815439320263163904 |