Desenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímica

Detalhes bibliográficos
Autor(a) principal: SOARES, Leonardo Carvalho
Data de Publicação: 2019
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UFMA
Texto Completo: https://tedebc.ufma.br/jspui/handle/tede/tede/2683
Resumo: This work describes the development of a novel method for glucose detection exploiting a photoelectrochemical-assisted batch injection analysis cell designed and constructed with aid of 3D printer technology. The PEC-BIA cell was coupled to a LED lamp in order to control the incidence of light on the Cu2O/Ni(OH)2/FTO photoelectro-active platform. The electrochemical characteristics of Cu2O/Ni(OH)2/FTO photoelec-troactive platform were evaluated by cyclic voltammetry, amperometry and electro-chemical impedance spectroscopy. The PEC-BIA cell presented linear response range, limit of detection and sensitivity of 1 – 1000 μmol L-1, 0.59 mol L-1 and 0.578 A L mol-1, respectively. The PEC-BIA method has presented a mean value of the recovery values of 97.0 % to 102.0% when it was applied to glucose determination in artificial blood plasma samples which indicates the promising performance of the proposed sys-tem to determine glucose.
id UFMA_48e7510a4aa8c0806a3acef329dc7c65
oai_identifier_str oai:tede2:tede/2683
network_acronym_str UFMA
network_name_str Biblioteca Digital de Teses e Dissertações da UFMA
repository_id_str 2131
spelling DAMOS, Flávio Santos846255703-87http://lattes.cnpq.br/0915687070195770DAMOS, Flávio Santos846255703-87http://lattes.cnpq.br/0915687070195770SILVA, Iranaldo Santos dahttp://lattes.cnpq.br/1281555528581499ARAÚJO, Adriana Barbosahttp://lattes.cnpq.br/1008844766307732054239053-11http://lattes.cnpq.br/3200985865107967SOARES, Leonardo Carvalho2019-05-21T19:23:51Z2019-03-22SOARES, Leonardo Carvalho. Desenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímica. 2019. 81 f. Dissertação (Programa de Pós-Graduação em Química/CCET) - Universidade Federal do Maranhão, São Luis.https://tedebc.ufma.br/jspui/handle/tede/tede/2683This work describes the development of a novel method for glucose detection exploiting a photoelectrochemical-assisted batch injection analysis cell designed and constructed with aid of 3D printer technology. The PEC-BIA cell was coupled to a LED lamp in order to control the incidence of light on the Cu2O/Ni(OH)2/FTO photoelectro-active platform. The electrochemical characteristics of Cu2O/Ni(OH)2/FTO photoelec-troactive platform were evaluated by cyclic voltammetry, amperometry and electro-chemical impedance spectroscopy. The PEC-BIA cell presented linear response range, limit of detection and sensitivity of 1 – 1000 μmol L-1, 0.59 mol L-1 and 0.578 A L mol-1, respectively. The PEC-BIA method has presented a mean value of the recovery values of 97.0 % to 102.0% when it was applied to glucose determination in artificial blood plasma samples which indicates the promising performance of the proposed sys-tem to determine glucose.Este trabalho descreve o desenvolvimento de um novo método para a detec-ção de glicose explorando uma célula de análise por injeção em batelada assistida por fotoeletroquímica, projetada e construída com auxílio de tecnologia de impressão 3D. A célula BIA foi acoplada a uma lâmpada LED para controlara a incidência de luz na plataforma fotoeletroativa Cu2O/Ni(OH)2/FTO. As características eletroquímicas da plataforma fotoeletroativa Cu2O/Ni(OH)2/FTO foram avaliadas por voltametria cí-clica, amperometria e espectroscopia de impedância eletroquímica. A célula PEC-BIA apresentou faixa de resposta linear, limite de detecção e sensibilidade de 1 - 1000 μmol L-1, 0,59 μmol L-1, respectivamente. O método PEC-BIA apresentou um valor médio de recuperação de 97,0% a 102,0% quando aplicado à determinação de glicose em amostras de plasma sanguíneo artificial, o que indica desempenho promissor do sis-tema proposto para determinação de glicose.Submitted by Sheila MONTEIRO (sheila.monteiro@ufma.br) on 2019-05-21T19:23:51Z No. of bitstreams: 1 Dissertação_Leonardo_Carvalho_Soares.pdf: 2102356 bytes, checksum: deacda83b2c98656345916438964f0ae (MD5)Made available in DSpace on 2019-05-21T19:23:51Z (GMT). No. of bitstreams: 1 Dissertação_Leonardo_Carvalho_Soares.pdf: 2102356 bytes, checksum: deacda83b2c98656345916438964f0ae (MD5) Previous issue date: 2019-03-22FAPEMACAPESCNPqapplication/pdfporUniversidade Federal do MaranhãoPROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCETUFMABrasilDEPARTAMENTO DE QUÍMICA/CCETSensor fotoeletroquímicoGlicoseAnálise por injeção em bateladaÓxido cuproso (Cu2O)Hidróxido de Níquel (Ni(OH)2)Photoelectrochemical sensorGlucoseBatch injection analysisCuprous oxide (Cu2O)Nickel Hydroxide (Ni(OH)2)QuímicaDesenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímicaDevelopment of a system for glucose determination using batch injection analysis by photoelectrochemistryinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UFMAinstname:Universidade Federal do Maranhão (UFMA)instacron:UFMAORIGINALDissertação_Leonardo_Carvalho_Soares.pdfDissertação_Leonardo_Carvalho_Soares.pdfapplication/pdf2102356http://tedebc.ufma.br:8080/bitstream/tede/2683/2/Disserta%C3%A7%C3%A3o_Leonardo_Carvalho_Soares.pdfdeacda83b2c98656345916438964f0aeMD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82255http://tedebc.ufma.br:8080/bitstream/tede/2683/1/license.txt97eeade1fce43278e63fe063657f8083MD51tede/26832019-05-21 16:23:51.479oai:tede2: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Biblioteca Digital de Teses e Dissertaçõeshttps://tedebc.ufma.br/jspui/PUBhttp://tedebc.ufma.br:8080/oai/requestrepositorio@ufma.br||repositorio@ufma.bropendoar:21312019-05-21T19:23:51Biblioteca Digital de Teses e Dissertações da UFMA - Universidade Federal do Maranhão (UFMA)false
dc.title.por.fl_str_mv Desenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímica
dc.title.alternative.eng.fl_str_mv Development of a system for glucose determination using batch injection analysis by photoelectrochemistry
title Desenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímica
spellingShingle Desenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímica
SOARES, Leonardo Carvalho
Sensor fotoeletroquímico
Glicose
Análise por injeção em batelada
Óxido cuproso (Cu2O)
Hidróxido de Níquel (Ni(OH)2)
Photoelectrochemical sensor
Glucose
Batch injection analysis
Cuprous oxide (Cu2O)
Nickel Hydroxide (Ni(OH)2)
Química
title_short Desenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímica
title_full Desenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímica
title_fullStr Desenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímica
title_full_unstemmed Desenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímica
title_sort Desenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímica
author SOARES, Leonardo Carvalho
author_facet SOARES, Leonardo Carvalho
author_role author
dc.contributor.advisor1.fl_str_mv DAMOS, Flávio Santos
dc.contributor.advisor1ID.fl_str_mv 846255703-87
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/0915687070195770
dc.contributor.referee1.fl_str_mv DAMOS, Flávio Santos
dc.contributor.referee1ID.fl_str_mv 846255703-87
dc.contributor.referee1Lattes.fl_str_mv http://lattes.cnpq.br/0915687070195770
dc.contributor.referee2.fl_str_mv SILVA, Iranaldo Santos da
dc.contributor.referee2Lattes.fl_str_mv http://lattes.cnpq.br/1281555528581499
dc.contributor.referee3.fl_str_mv ARAÚJO, Adriana Barbosa
dc.contributor.referee3Lattes.fl_str_mv http://lattes.cnpq.br/1008844766307732
dc.contributor.authorID.fl_str_mv 054239053-11
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/3200985865107967
dc.contributor.author.fl_str_mv SOARES, Leonardo Carvalho
contributor_str_mv DAMOS, Flávio Santos
DAMOS, Flávio Santos
SILVA, Iranaldo Santos da
ARAÚJO, Adriana Barbosa
dc.subject.por.fl_str_mv Sensor fotoeletroquímico
Glicose
Análise por injeção em batelada
Óxido cuproso (Cu2O)
Hidróxido de Níquel (Ni(OH)2)
topic Sensor fotoeletroquímico
Glicose
Análise por injeção em batelada
Óxido cuproso (Cu2O)
Hidróxido de Níquel (Ni(OH)2)
Photoelectrochemical sensor
Glucose
Batch injection analysis
Cuprous oxide (Cu2O)
Nickel Hydroxide (Ni(OH)2)
Química
dc.subject.eng.fl_str_mv Photoelectrochemical sensor
Glucose
Batch injection analysis
Cuprous oxide (Cu2O)
Nickel Hydroxide (Ni(OH)2)
dc.subject.cnpq.fl_str_mv Química
description This work describes the development of a novel method for glucose detection exploiting a photoelectrochemical-assisted batch injection analysis cell designed and constructed with aid of 3D printer technology. The PEC-BIA cell was coupled to a LED lamp in order to control the incidence of light on the Cu2O/Ni(OH)2/FTO photoelectro-active platform. The electrochemical characteristics of Cu2O/Ni(OH)2/FTO photoelec-troactive platform were evaluated by cyclic voltammetry, amperometry and electro-chemical impedance spectroscopy. The PEC-BIA cell presented linear response range, limit of detection and sensitivity of 1 – 1000 μmol L-1, 0.59 mol L-1 and 0.578 A L mol-1, respectively. The PEC-BIA method has presented a mean value of the recovery values of 97.0 % to 102.0% when it was applied to glucose determination in artificial blood plasma samples which indicates the promising performance of the proposed sys-tem to determine glucose.
publishDate 2019
dc.date.accessioned.fl_str_mv 2019-05-21T19:23:51Z
dc.date.issued.fl_str_mv 2019-03-22
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv SOARES, Leonardo Carvalho. Desenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímica. 2019. 81 f. Dissertação (Programa de Pós-Graduação em Química/CCET) - Universidade Federal do Maranhão, São Luis.
dc.identifier.uri.fl_str_mv https://tedebc.ufma.br/jspui/handle/tede/tede/2683
identifier_str_mv SOARES, Leonardo Carvalho. Desenvolvimento de um sistema para determinação de glicose usando análise por injeção em batelada assistida por fotoeletroquímica. 2019. 81 f. Dissertação (Programa de Pós-Graduação em Química/CCET) - Universidade Federal do Maranhão, São Luis.
url https://tedebc.ufma.br/jspui/handle/tede/tede/2683
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal do Maranhão
dc.publisher.program.fl_str_mv PROGRAMA DE PÓS-GRADUAÇÃO EM QUÍMICA/CCET
dc.publisher.initials.fl_str_mv UFMA
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv DEPARTAMENTO DE QUÍMICA/CCET
publisher.none.fl_str_mv Universidade Federal do Maranhão
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UFMA
instname:Universidade Federal do Maranhão (UFMA)
instacron:UFMA
instname_str Universidade Federal do Maranhão (UFMA)
instacron_str UFMA
institution UFMA
reponame_str Biblioteca Digital de Teses e Dissertações da UFMA
collection Biblioteca Digital de Teses e Dissertações da UFMA
bitstream.url.fl_str_mv http://tedebc.ufma.br:8080/bitstream/tede/2683/2/Disserta%C3%A7%C3%A3o_Leonardo_Carvalho_Soares.pdf
http://tedebc.ufma.br:8080/bitstream/tede/2683/1/license.txt
bitstream.checksum.fl_str_mv deacda83b2c98656345916438964f0ae
97eeade1fce43278e63fe063657f8083
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da UFMA - Universidade Federal do Maranhão (UFMA)
repository.mail.fl_str_mv repositorio@ufma.br||repositorio@ufma.br
_version_ 1809926192602546176