B-mode and Doppler ultrasonography of adrenal glands of healthy dogs

Detalhes bibliográficos
Autor(a) principal: Fernandez,S.
Data de Publicação: 2016
Outros Autores: Feliciano,M.A.R., Crivellenti,S.B., Crivellenti,L.Z., Simões,A.P.R., Maronezi,M.C., Uscategui,R.R., Capela,C.R., Gilor,C., Santana,A.E., Vicente,W.R.R.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivo brasileiro de medicina veterinária e zootecnia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352016000400907
Resumo: ABSTRACT The aim of this study was to determine the vascular indices of adrenal blood flow in healthy dogs (systolic velocity - SV; diastolic velocity - DV; resistance index - RI). Eighteen dogs (thirty six adrenal) were studied. Physical examination, biochemical profile and dexamethasone suppression test were performed to determine general health status. Echotexture, size, contours and margins, and overall shape of the adrenal gland (right and left) were assessed via ultrasound. By spectral Doppler of the phrenic-abdominal artery, the SV, DV, and RI were acquired. Animals did not show alterations in clinical and laboratory examination and suppression of cortisol. Normal homogeneous and echotexture, regular contours and margins and normal shape and size were verified via B mode. Spectral Doppler of the phrenic-abdominal artery showed monophasic-patterned waves and low vascular resistance and systolic peak evident with means values: left adrenal - SV = 31.34cm/s, DV = 9.54cm/s and RI = 0.69; and right adrenal - SV = 27.83cm/s, DV = 7.71cm/s and RI = 0.68. Doppler evaluation of adrenal was easily implemented and may provide base line data in the study, allowing for the use of this technique as a diagnostic tool for diseases of the dog's adrenal.
id UFMG-8_7e559907c8bab06a5a580e7fbb61650c
oai_identifier_str oai:scielo:S0102-09352016000400907
network_acronym_str UFMG-8
network_name_str Arquivo brasileiro de medicina veterinária e zootecnia (Online)
repository_id_str
spelling B-mode and Doppler ultrasonography of adrenal glands of healthy dogscanineadrenal glandsultrasoundvascularizationABSTRACT The aim of this study was to determine the vascular indices of adrenal blood flow in healthy dogs (systolic velocity - SV; diastolic velocity - DV; resistance index - RI). Eighteen dogs (thirty six adrenal) were studied. Physical examination, biochemical profile and dexamethasone suppression test were performed to determine general health status. Echotexture, size, contours and margins, and overall shape of the adrenal gland (right and left) were assessed via ultrasound. By spectral Doppler of the phrenic-abdominal artery, the SV, DV, and RI were acquired. Animals did not show alterations in clinical and laboratory examination and suppression of cortisol. Normal homogeneous and echotexture, regular contours and margins and normal shape and size were verified via B mode. Spectral Doppler of the phrenic-abdominal artery showed monophasic-patterned waves and low vascular resistance and systolic peak evident with means values: left adrenal - SV = 31.34cm/s, DV = 9.54cm/s and RI = 0.69; and right adrenal - SV = 27.83cm/s, DV = 7.71cm/s and RI = 0.68. Doppler evaluation of adrenal was easily implemented and may provide base line data in the study, allowing for the use of this technique as a diagnostic tool for diseases of the dog's adrenal.Universidade Federal de Minas Gerais, Escola de Veterinária2016-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352016000400907Arquivo Brasileiro de Medicina Veterinária e Zootecnia v.68 n.4 2016reponame:Arquivo brasileiro de medicina veterinária e zootecnia (Online)instname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMG10.1590/1678-4162-8644info:eu-repo/semantics/openAccessFernandez,S.Feliciano,M.A.R.Crivellenti,S.B.Crivellenti,L.Z.Simões,A.P.R.Maronezi,M.C.Uscategui,R.R.Capela,C.R.Gilor,C.Santana,A.E.Vicente,W.R.R.eng2016-08-18T00:00:00Zoai:scielo:S0102-09352016000400907Revistahttps://www.scielo.br/j/abmvz/PUBhttps://old.scielo.br/oai/scielo-oai.phpjournal@vet.ufmg.br||abmvz.artigo@abmvz.org.br1678-41620102-0935opendoar:2016-08-18T00:00Arquivo brasileiro de medicina veterinária e zootecnia (Online) - Universidade Federal de Minas Gerais (UFMG)false
dc.title.none.fl_str_mv B-mode and Doppler ultrasonography of adrenal glands of healthy dogs
title B-mode and Doppler ultrasonography of adrenal glands of healthy dogs
spellingShingle B-mode and Doppler ultrasonography of adrenal glands of healthy dogs
Fernandez,S.
canine
adrenal glands
ultrasound
vascularization
title_short B-mode and Doppler ultrasonography of adrenal glands of healthy dogs
title_full B-mode and Doppler ultrasonography of adrenal glands of healthy dogs
title_fullStr B-mode and Doppler ultrasonography of adrenal glands of healthy dogs
title_full_unstemmed B-mode and Doppler ultrasonography of adrenal glands of healthy dogs
title_sort B-mode and Doppler ultrasonography of adrenal glands of healthy dogs
author Fernandez,S.
author_facet Fernandez,S.
Feliciano,M.A.R.
Crivellenti,S.B.
Crivellenti,L.Z.
Simões,A.P.R.
Maronezi,M.C.
Uscategui,R.R.
Capela,C.R.
Gilor,C.
Santana,A.E.
Vicente,W.R.R.
author_role author
author2 Feliciano,M.A.R.
Crivellenti,S.B.
Crivellenti,L.Z.
Simões,A.P.R.
Maronezi,M.C.
Uscategui,R.R.
Capela,C.R.
Gilor,C.
Santana,A.E.
Vicente,W.R.R.
author2_role author
author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Fernandez,S.
Feliciano,M.A.R.
Crivellenti,S.B.
Crivellenti,L.Z.
Simões,A.P.R.
Maronezi,M.C.
Uscategui,R.R.
Capela,C.R.
Gilor,C.
Santana,A.E.
Vicente,W.R.R.
dc.subject.por.fl_str_mv canine
adrenal glands
ultrasound
vascularization
topic canine
adrenal glands
ultrasound
vascularization
description ABSTRACT The aim of this study was to determine the vascular indices of adrenal blood flow in healthy dogs (systolic velocity - SV; diastolic velocity - DV; resistance index - RI). Eighteen dogs (thirty six adrenal) were studied. Physical examination, biochemical profile and dexamethasone suppression test were performed to determine general health status. Echotexture, size, contours and margins, and overall shape of the adrenal gland (right and left) were assessed via ultrasound. By spectral Doppler of the phrenic-abdominal artery, the SV, DV, and RI were acquired. Animals did not show alterations in clinical and laboratory examination and suppression of cortisol. Normal homogeneous and echotexture, regular contours and margins and normal shape and size were verified via B mode. Spectral Doppler of the phrenic-abdominal artery showed monophasic-patterned waves and low vascular resistance and systolic peak evident with means values: left adrenal - SV = 31.34cm/s, DV = 9.54cm/s and RI = 0.69; and right adrenal - SV = 27.83cm/s, DV = 7.71cm/s and RI = 0.68. Doppler evaluation of adrenal was easily implemented and may provide base line data in the study, allowing for the use of this technique as a diagnostic tool for diseases of the dog's adrenal.
publishDate 2016
dc.date.none.fl_str_mv 2016-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352016000400907
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352016000400907
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1678-4162-8644
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Universidade Federal de Minas Gerais, Escola de Veterinária
publisher.none.fl_str_mv Universidade Federal de Minas Gerais, Escola de Veterinária
dc.source.none.fl_str_mv Arquivo Brasileiro de Medicina Veterinária e Zootecnia v.68 n.4 2016
reponame:Arquivo brasileiro de medicina veterinária e zootecnia (Online)
instname:Universidade Federal de Minas Gerais (UFMG)
instacron:UFMG
instname_str Universidade Federal de Minas Gerais (UFMG)
instacron_str UFMG
institution UFMG
reponame_str Arquivo brasileiro de medicina veterinária e zootecnia (Online)
collection Arquivo brasileiro de medicina veterinária e zootecnia (Online)
repository.name.fl_str_mv Arquivo brasileiro de medicina veterinária e zootecnia (Online) - Universidade Federal de Minas Gerais (UFMG)
repository.mail.fl_str_mv journal@vet.ufmg.br||abmvz.artigo@abmvz.org.br
_version_ 1750220889934266368