Resumo: O objetivo deste trabalho foi avaliar o desempenho de um sistema composto de reator anaeróbio compartimentado (RAC) seguido por filtro anaeróbio (FA), tratando águas residuárias de uma granja suinícola de pequeno porte. Foram analisados os parâmetros: pH, ácidos voláteis totais (AVT), demanda química de oxigênio total (DQOt), demanda química de oxigênio dissolvida (DQOdiss), demanda química de oxigênio devida aos sólidos suspensos (DQOSS), sólidos suspensos totais (SST), sólidos suspensos voláteis (SSV) e nitrogênio total kjeldhal (NTK). Os valores efluentes no RAC e no FA, de DQOt, SST e NTK, foram 6.633 e 4.361 mg.L-1, 2.418 e 595 mg.L-1 e 888 e 954 mg.L-1, respectivamente, para uma carga orgânica volumétrica (COV) de 7,01 kgDQO(m3.d)-1 no RAC e 28,3 kgDQO(m3.d)-1 no FA, e tempo de detenção hidráulico de 70,5 e 17,8 h no RAC e no FA, respectivamente. O sistema RAC seguido de FA mostrou eficiência de remoção média de 88,8% para DQOt e 80,5% de SST. Conclui-se que o sistema de tratamento anaeróbio, composto por RAC seguido de FA, foi eficiente na remoção de DQO e SST, possibilitando, nas condições operacionais impostas, alcançar valores médios de remoção acima de 80%, tornando-se uma ótima alternativa de tratamento de efluentes de suinocultura para granjas de pequeno porte.
id UFMG_4a817d56c54c70fd64349bc6c414d966
oai_identifier_str oai:repositorio.ufmg.br:1843/67500
network_acronym_str UFMG
network_name_str Repositório Institucional da UFMG
repository_id_str
spelling 2024-04-19T19:19:13Z2024-04-19T19:19:13Z2020253451456https://doi.org/10.1590/S1413-415220201376611809-4457http://hdl.handle.net/1843/67500https://orcid.org/0000-0003-0555-8305https://orcid.org/0000-0002-2816-3317https://orcid.org/0000-0002-1771-0821https://orcid.org/0000-0003-2050-6706https://orcid.org/0000-0002-6345-3256https://orcid.org/0000-0001-6670-2628O objetivo deste trabalho foi avaliar o desempenho de um sistema composto de reator anaeróbio compartimentado (RAC) seguido por filtro anaeróbio (FA), tratando águas residuárias de uma granja suinícola de pequeno porte. Foram analisados os parâmetros: pH, ácidos voláteis totais (AVT), demanda química de oxigênio total (DQOt), demanda química de oxigênio dissolvida (DQOdiss), demanda química de oxigênio devida aos sólidos suspensos (DQOSS), sólidos suspensos totais (SST), sólidos suspensos voláteis (SSV) e nitrogênio total kjeldhal (NTK). Os valores efluentes no RAC e no FA, de DQOt, SST e NTK, foram 6.633 e 4.361 mg.L-1, 2.418 e 595 mg.L-1 e 888 e 954 mg.L-1, respectivamente, para uma carga orgânica volumétrica (COV) de 7,01 kgDQO(m3.d)-1 no RAC e 28,3 kgDQO(m3.d)-1 no FA, e tempo de detenção hidráulico de 70,5 e 17,8 h no RAC e no FA, respectivamente. O sistema RAC seguido de FA mostrou eficiência de remoção média de 88,8% para DQOt e 80,5% de SST. Conclui-se que o sistema de tratamento anaeróbio, composto por RAC seguido de FA, foi eficiente na remoção de DQO e SST, possibilitando, nas condições operacionais impostas, alcançar valores médios de remoção acima de 80%, tornando-se uma ótima alternativa de tratamento de efluentes de suinocultura para granjas de pequeno porte.The aim of this work was to assess the performance of a system composed by a compartmentalized anaerobic reactor (CAR) followed by anaerobic filter (AF) in the treatment of the wastewater of as mall pigfarm.The following parameters were analyzed: pH, total volatilefatty acids (VFA), total demand of chemical oxygen (DCOt), dissolved chemical oxygen demand (CODdiss), chemical oxygen demand due to suspended solids (CODSS), total suspended solids (TSS), volatile suspended solids (VSS) and total kjeldhal nitrogen (TKN). The effluents and AF values for the CAR, the DCOt, TSS and TKN were 6,633 and 4,361mg.L-1, 2,418 and 595 mg.L-1, and 888 and 954 mg.L-1, respectively, for a volumetric organic load (VOL) of 7.01 kgDCO(m3.d)-1 in CAR and 28.3 kgDCO(m3.d)-1 in AF, and hydraulic detention time of 70.5 hand 17.8 hin CAR and AF, respectively. The CAR system followed by FA presented a mean removal efficiency of 88.8% for COD and 80.5% for TSS. It is concluded that the anaerobic treatment system consisting of CAR followed by AF was efficient in removing DCO and TSS, allowing with the imposed operating conditions to achieve average removal values above 80%, becoming a great alternative for wastewater treatment in small swinefarms.porUniversidade Federal de Minas GeraisUFMGBrasilVET - DEPARTAMENTO DE MEDICINA VETERINÁRIA PREVENTIVAVETER - ESCOLA DE VETERINARIAEngenharia Sanitária e AmbientalMeio AmbientePoluição AmbientalÁguas ResiduáriasAgropecuáriaDigestão AnaeróbiaAgropecuáriaÁguas residuáriasImpacto ambientalDigestão AnaeróbiaDejeitos de suínosAplicabilidade de sistema reator anaeróbio compartimentado seguida de filtro anaeróbio no tratamento de efluentes de suinocultura de pequeno porteApplicability of compartmentalized anaerobic reactor system followed by anaerobic filter on small swine wastewater treatmentinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttps://www.scielo.br/j/esa/a/YDq6vpsf8vbfGYSHJf7mFhr/?lang=ptLuciano Dos Santos RodriguesEdnardi Pereira TorresLucas Alves RodriguesJoyce da Cruz Ferraz DutraRenata Rodrigues SampaioIsrael José da Silvaapplication/pdfinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFMGinstname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMGLICENSELicense.txtLicense.txttext/plain; charset=utf-82042https://repositorio.ufmg.br/bitstream/1843/67500/1/License.txtfa505098d172de0bc8864fc1287ffe22MD51ORIGINALAplicabilidade de sistema reator anaeróbio compartimentado seguida de filtro anaeróbio no tratamento de efluentes de suinocultura de pequeno porte.pdfAplicabilidade de sistema reator anaeróbio compartimentado seguida de filtro anaeróbio no tratamento de efluentes de suinocultura de pequeno porte.pdfapplication/pdf321643https://repositorio.ufmg.br/bitstream/1843/67500/2/Aplicabilidade%20de%20sistema%20reator%20anaer%c3%b3bio%20compartimentado%20seguida%20de%20filtro%20anaer%c3%b3bio%20no%20tratamento%20de%20efluentes%20de%20suinocultura%20de%20pequeno%20porte.pdf8d3a9130b5aadc47aa72941770e205eeMD521843/675002024-04-19 16:19:14.957oai:repositorio.ufmg.br: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Repositório de PublicaçõesPUBhttps://repositorio.ufmg.br/oaiopendoar:2024-04-19T19:19:14Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)false
dc.title.pt_BR.fl_str_mv Aplicabilidade de sistema reator anaeróbio compartimentado seguida de filtro anaeróbio no tratamento de efluentes de suinocultura de pequeno porte
dc.title.alternative.pt_BR.fl_str_mv Applicability of compartmentalized anaerobic reactor system followed by anaerobic filter on small swine wastewater treatment
title Aplicabilidade de sistema reator anaeróbio compartimentado seguida de filtro anaeróbio no tratamento de efluentes de suinocultura de pequeno porte
spellingShingle Aplicabilidade de sistema reator anaeróbio compartimentado seguida de filtro anaeróbio no tratamento de efluentes de suinocultura de pequeno porte
Luciano Dos Santos Rodrigues
Agropecuária
Águas residuárias
Impacto ambiental
Digestão Anaeróbia
Dejeitos de suínos
Meio Ambiente
Poluição Ambiental
Águas Residuárias
Agropecuária
Digestão Anaeróbia
title_short Aplicabilidade de sistema reator anaeróbio compartimentado seguida de filtro anaeróbio no tratamento de efluentes de suinocultura de pequeno porte
title_full Aplicabilidade de sistema reator anaeróbio compartimentado seguida de filtro anaeróbio no tratamento de efluentes de suinocultura de pequeno porte
title_fullStr Aplicabilidade de sistema reator anaeróbio compartimentado seguida de filtro anaeróbio no tratamento de efluentes de suinocultura de pequeno porte
title_full_unstemmed Aplicabilidade de sistema reator anaeróbio compartimentado seguida de filtro anaeróbio no tratamento de efluentes de suinocultura de pequeno porte
title_sort Aplicabilidade de sistema reator anaeróbio compartimentado seguida de filtro anaeróbio no tratamento de efluentes de suinocultura de pequeno porte
author Luciano Dos Santos Rodrigues
author_facet Luciano Dos Santos Rodrigues
Ednardi Pereira Torres
Lucas Alves Rodrigues
Joyce da Cruz Ferraz Dutra
Renata Rodrigues Sampaio
Israel José da Silva
author_role author
author2 Ednardi Pereira Torres
Lucas Alves Rodrigues
Joyce da Cruz Ferraz Dutra
Renata Rodrigues Sampaio
Israel José da Silva
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Luciano Dos Santos Rodrigues
Ednardi Pereira Torres
Lucas Alves Rodrigues
Joyce da Cruz Ferraz Dutra
Renata Rodrigues Sampaio
Israel José da Silva
dc.subject.por.fl_str_mv Agropecuária
Águas residuárias
Impacto ambiental
Digestão Anaeróbia
Dejeitos de suínos
topic Agropecuária
Águas residuárias
Impacto ambiental
Digestão Anaeróbia
Dejeitos de suínos
Meio Ambiente
Poluição Ambiental
Águas Residuárias
Agropecuária
Digestão Anaeróbia
dc.subject.other.pt_BR.fl_str_mv Meio Ambiente
Poluição Ambiental
Águas Residuárias
Agropecuária
Digestão Anaeróbia
description O objetivo deste trabalho foi avaliar o desempenho de um sistema composto de reator anaeróbio compartimentado (RAC) seguido por filtro anaeróbio (FA), tratando águas residuárias de uma granja suinícola de pequeno porte. Foram analisados os parâmetros: pH, ácidos voláteis totais (AVT), demanda química de oxigênio total (DQOt), demanda química de oxigênio dissolvida (DQOdiss), demanda química de oxigênio devida aos sólidos suspensos (DQOSS), sólidos suspensos totais (SST), sólidos suspensos voláteis (SSV) e nitrogênio total kjeldhal (NTK). Os valores efluentes no RAC e no FA, de DQOt, SST e NTK, foram 6.633 e 4.361 mg.L-1, 2.418 e 595 mg.L-1 e 888 e 954 mg.L-1, respectivamente, para uma carga orgânica volumétrica (COV) de 7,01 kgDQO(m3.d)-1 no RAC e 28,3 kgDQO(m3.d)-1 no FA, e tempo de detenção hidráulico de 70,5 e 17,8 h no RAC e no FA, respectivamente. O sistema RAC seguido de FA mostrou eficiência de remoção média de 88,8% para DQOt e 80,5% de SST. Conclui-se que o sistema de tratamento anaeróbio, composto por RAC seguido de FA, foi eficiente na remoção de DQO e SST, possibilitando, nas condições operacionais impostas, alcançar valores médios de remoção acima de 80%, tornando-se uma ótima alternativa de tratamento de efluentes de suinocultura para granjas de pequeno porte.
publishDate 2020
dc.date.issued.fl_str_mv 2020
dc.date.accessioned.fl_str_mv 2024-04-19T19:19:13Z
dc.date.available.fl_str_mv 2024-04-19T19:19:13Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1843/67500
dc.identifier.doi.pt_BR.fl_str_mv https://doi.org/10.1590/S1413-41522020137661
dc.identifier.issn.pt_BR.fl_str_mv 1809-4457
dc.identifier.orcid.pt_BR.fl_str_mv https://orcid.org/0000-0003-0555-8305
https://orcid.org/0000-0002-2816-3317
https://orcid.org/0000-0002-1771-0821
https://orcid.org/0000-0003-2050-6706
https://orcid.org/0000-0002-6345-3256
https://orcid.org/0000-0001-6670-2628
url https://doi.org/10.1590/S1413-41522020137661
http://hdl.handle.net/1843/67500
https://orcid.org/0000-0003-0555-8305
https://orcid.org/0000-0002-2816-3317
https://orcid.org/0000-0002-1771-0821
https://orcid.org/0000-0003-2050-6706
https://orcid.org/0000-0002-6345-3256
https://orcid.org/0000-0001-6670-2628
identifier_str_mv 1809-4457
dc.language.iso.fl_str_mv por
language por
dc.relation.ispartof.pt_BR.fl_str_mv Engenharia Sanitária e Ambiental
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Minas Gerais
dc.publisher.initials.fl_str_mv UFMG
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv VET - DEPARTAMENTO DE MEDICINA VETERINÁRIA PREVENTIVA
VETER - ESCOLA DE VETERINARIA
publisher.none.fl_str_mv Universidade Federal de Minas Gerais
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFMG
instname:Universidade Federal de Minas Gerais (UFMG)
instacron:UFMG
instname_str Universidade Federal de Minas Gerais (UFMG)
instacron_str UFMG
institution UFMG
reponame_str Repositório Institucional da UFMG
collection Repositório Institucional da UFMG
bitstream.url.fl_str_mv https://repositorio.ufmg.br/bitstream/1843/67500/1/License.txt
https://repositorio.ufmg.br/bitstream/1843/67500/2/Aplicabilidade%20de%20sistema%20reator%20anaer%c3%b3bio%20compartimentado%20seguida%20de%20filtro%20anaer%c3%b3bio%20no%20tratamento%20de%20efluentes%20de%20suinocultura%20de%20pequeno%20porte.pdf
bitstream.checksum.fl_str_mv fa505098d172de0bc8864fc1287ffe22
8d3a9130b5aadc47aa72941770e205ee
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)
repository.mail.fl_str_mv
_version_ 1803589465891930112