Adaptação marginal de copings metálicos confeccionados no sistema CAD/CAM CEREC
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFMG |
Texto Completo: | http://hdl.handle.net/1843/41898 |
Resumo: | The present study verified the marginal adaptation between the metallic infrastructure for metal-ceramic restoration and the anatomical trunnion-type prosthetic component for cone morse implant using the CEREC system (Sirona Dental Company, Germany). For the execution of the present laboratory study was made a rectangular aluminum base with height of 2.5cm and width of 2.5cm. In the center of the base was installed an implant of the cone morse system with 11,0mm of length and 4.0mm of diameter and fixed an anatomical trunnion cone morse. The master model was scanned by the CAD / Cerec Omnicam unit. With the image file generated, the coping was designed in the CEREC Premium Software SW 4.4.2 and exported to the software CEREC Premium CAM SW 4.4.2 for milling. Four copings were achieved using the MCXL Miller and VITA CAD-Waxx blocks with Shaper 25RZ and Finisher 10 cutters and obtained by the lost wax process using nickel-chromium alloy metal. The verification of the cervical adaptation was performed using the Mitutoyo (TM 500) optical comparator microscope at the interface between the metallic / prosthetic component at the mesial, buccal, distal and lingual surfaces. The results showed an average cervical inadaptation of 146.0 μm, however this value was higher than the clinically acceptable marginal discrepancy. |
id |
UFMG_5c5b9ee22b1d5efcaab2dce2eac80461 |
---|---|
oai_identifier_str |
oai:repositorio.ufmg.br:1843/41898 |
network_acronym_str |
UFMG |
network_name_str |
Repositório Institucional da UFMG |
repository_id_str |
|
spelling |
Adaptação marginal de copings metálicos confeccionados no sistema CAD/CAM CERECLigas metalo-cerâmicasPorcelana dentáriaSistema CAD/CAMLigas metalo-cerâmicasPorcelana dentáriaImplantação dentáriaAdaptaçãoThe present study verified the marginal adaptation between the metallic infrastructure for metal-ceramic restoration and the anatomical trunnion-type prosthetic component for cone morse implant using the CEREC system (Sirona Dental Company, Germany). For the execution of the present laboratory study was made a rectangular aluminum base with height of 2.5cm and width of 2.5cm. In the center of the base was installed an implant of the cone morse system with 11,0mm of length and 4.0mm of diameter and fixed an anatomical trunnion cone morse. The master model was scanned by the CAD / Cerec Omnicam unit. With the image file generated, the coping was designed in the CEREC Premium Software SW 4.4.2 and exported to the software CEREC Premium CAM SW 4.4.2 for milling. Four copings were achieved using the MCXL Miller and VITA CAD-Waxx blocks with Shaper 25RZ and Finisher 10 cutters and obtained by the lost wax process using nickel-chromium alloy metal. The verification of the cervical adaptation was performed using the Mitutoyo (TM 500) optical comparator microscope at the interface between the metallic / prosthetic component at the mesial, buccal, distal and lingual surfaces. The results showed an average cervical inadaptation of 146.0 μm, however this value was higher than the clinically acceptable marginal discrepancy.O presente estudo verificou a adaptação marginal entre a infraestrutura metálica para restauração metalocerâmica e o componente protético do tipo munhão anatômico para implante cone morse utilizando o sistema CEREC (Sirona Dental Company, Alemanha). Para execução do presente estudo laboratorial foi confeccionada uma base de alumínio retangular com altura de 2,5cm e largura de 2,5cm. No centro da base foi instalado um implante do sistema cone morse com 11,0mm de comprimento e 4,0mm de diâmetro e fixado um munhão anatômico cone morse. O modelo mestre foi scaneado pela unidade CAD/Cerec Omnicam. Com o arquivo de imagem gerado, o coping foi desenhado no Software CEREC Premium SW 4.4.2 e exportado para o software CEREC Premium CAM SW 4.4.2 para a fresagem. Quatro copings foram conseguidos utilizando a Fresadora MCXL e blocos VITA CAD-Waxx com fresas Shaper 25RZ e Finisher 10 e obtidos pelo processo de cera perdida utilizando liga metálica do sistema níquel-cromo. A verificação da adaptação cervical foi com auxílio de microscópio comparador óptico Mitutoyo (TM 500) na interface entre a infraestrutura metálica/componente protético nas faces mesial, vestibular, distal e lingual. Os resultados revelaram uma desadaptação cervical média de 146,0µm, entretanto esse valor foi superior à discrepância marginal clinicamente aceitável.Universidade Federal de Minas GeraisBrasilFAO - DEPARTAMENTO DE ODONTOLOGIA RESTAURADORACurso de Especialização em ImplantodontiaUFMGRicardo Rodrigues Vazhttp://lattes.cnpq.br/2507338603377062Guilherme Moraes Garcia Leão2022-05-23T19:04:22Z2022-05-23T19:04:22Z2017Monografia (especialização)info:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/1843/41898porinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFMGinstname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMG2022-05-23T19:04:22Zoai:repositorio.ufmg.br:1843/41898Repositório InstitucionalPUBhttps://repositorio.ufmg.br/oairepositorio@ufmg.bropendoar:2022-05-23T19:04:22Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)false |
dc.title.none.fl_str_mv |
Adaptação marginal de copings metálicos confeccionados no sistema CAD/CAM CEREC |
title |
Adaptação marginal de copings metálicos confeccionados no sistema CAD/CAM CEREC |
spellingShingle |
Adaptação marginal de copings metálicos confeccionados no sistema CAD/CAM CEREC Guilherme Moraes Garcia Leão Ligas metalo-cerâmicas Porcelana dentária Sistema CAD/CAM Ligas metalo-cerâmicas Porcelana dentária Implantação dentária Adaptação |
title_short |
Adaptação marginal de copings metálicos confeccionados no sistema CAD/CAM CEREC |
title_full |
Adaptação marginal de copings metálicos confeccionados no sistema CAD/CAM CEREC |
title_fullStr |
Adaptação marginal de copings metálicos confeccionados no sistema CAD/CAM CEREC |
title_full_unstemmed |
Adaptação marginal de copings metálicos confeccionados no sistema CAD/CAM CEREC |
title_sort |
Adaptação marginal de copings metálicos confeccionados no sistema CAD/CAM CEREC |
author |
Guilherme Moraes Garcia Leão |
author_facet |
Guilherme Moraes Garcia Leão |
author_role |
author |
dc.contributor.none.fl_str_mv |
Ricardo Rodrigues Vaz http://lattes.cnpq.br/2507338603377062 |
dc.contributor.author.fl_str_mv |
Guilherme Moraes Garcia Leão |
dc.subject.por.fl_str_mv |
Ligas metalo-cerâmicas Porcelana dentária Sistema CAD/CAM Ligas metalo-cerâmicas Porcelana dentária Implantação dentária Adaptação |
topic |
Ligas metalo-cerâmicas Porcelana dentária Sistema CAD/CAM Ligas metalo-cerâmicas Porcelana dentária Implantação dentária Adaptação |
description |
The present study verified the marginal adaptation between the metallic infrastructure for metal-ceramic restoration and the anatomical trunnion-type prosthetic component for cone morse implant using the CEREC system (Sirona Dental Company, Germany). For the execution of the present laboratory study was made a rectangular aluminum base with height of 2.5cm and width of 2.5cm. In the center of the base was installed an implant of the cone morse system with 11,0mm of length and 4.0mm of diameter and fixed an anatomical trunnion cone morse. The master model was scanned by the CAD / Cerec Omnicam unit. With the image file generated, the coping was designed in the CEREC Premium Software SW 4.4.2 and exported to the software CEREC Premium CAM SW 4.4.2 for milling. Four copings were achieved using the MCXL Miller and VITA CAD-Waxx blocks with Shaper 25RZ and Finisher 10 cutters and obtained by the lost wax process using nickel-chromium alloy metal. The verification of the cervical adaptation was performed using the Mitutoyo (TM 500) optical comparator microscope at the interface between the metallic / prosthetic component at the mesial, buccal, distal and lingual surfaces. The results showed an average cervical inadaptation of 146.0 μm, however this value was higher than the clinically acceptable marginal discrepancy. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017 2022-05-23T19:04:22Z 2022-05-23T19:04:22Z |
dc.type.driver.fl_str_mv |
Monografia (especialização) |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1843/41898 |
url |
http://hdl.handle.net/1843/41898 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Minas Gerais Brasil FAO - DEPARTAMENTO DE ODONTOLOGIA RESTAURADORA Curso de Especialização em Implantodontia UFMG |
publisher.none.fl_str_mv |
Universidade Federal de Minas Gerais Brasil FAO - DEPARTAMENTO DE ODONTOLOGIA RESTAURADORA Curso de Especialização em Implantodontia UFMG |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFMG instname:Universidade Federal de Minas Gerais (UFMG) instacron:UFMG |
instname_str |
Universidade Federal de Minas Gerais (UFMG) |
instacron_str |
UFMG |
institution |
UFMG |
reponame_str |
Repositório Institucional da UFMG |
collection |
Repositório Institucional da UFMG |
repository.name.fl_str_mv |
Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG) |
repository.mail.fl_str_mv |
repositorio@ufmg.br |
_version_ |
1816829869191856128 |