Premature or small for gestational age discrimination: international multicenter trial protocol for classification of the low-birth-weight newborn through the optical properties of the skin

Detalhes bibliográficos
Autor(a) principal: Zilma Silveira Nogueira Reis
Data de Publicação: 2020
Outros Autores: Gabriela Luiza Nogueira Vitral, Rodney Nascimento Guimarães, Juliano de Souza Gaspar, Enrico Antônio Colosimo, Sérgio Augusto Taunde, Nilza Mussagy, Rita Rosado Santos, Diogo Ayres-de-Campos, Roberta Maia de Castro Romanelli
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UFMG
Texto Completo: https://doi.org/10.2196/16477
http://hdl.handle.net/1843/56728
https://orcid.org/0000-0001-6374-9295
https://orcid.org/0000-0001-7306-8776
https://orcid.org/0000-0001-5617-4470
https://orcid.org/0000-0003-0670-9021
https://orcid.org/0000-0001-8705-4674
https://orcid.org/0000-0003-3848-2861
https://orcid.org/0000-0002-0384-9574
https://orcid.org/0000-0002-9299-3366
https://orcid.org/0000-0002-7136-6240
https://orcid.org/0000-0002-1660-0751
Resumo: Introdução: O baixo peso ao nascer é um fator de risco independente para resultados adversos na infância e um preditor de doença crônica na vida adulta. Nessas situações, a diferenciação entre prematuridade e pequeno para a idade gestacional (PIG) ​​ou condições simultâneas é fundamental para garantir o cuidado adequado. Tais diagnósticos, no entanto, dependem de datações confiáveis ​​de gravidez, o que pode ser um desafio em países em desenvolvimento. Um novo dispositivo médico optoeletrônico foi desenvolvido para estimar a idade gestacional (IG) ao nascer com base na reflexão da pele do recém-nascido. Objetivo: Este estudo terá como objetivo avaliar a capacidade do dispositivo de detectar prematuridade ou PIG, ou ambas as condições simultaneamente, bem como prever complicações pulmonares de curto prazo em uma coorte de recém-nascidos de baixo peso. Métodos: Este protocolo de estudo foi desenhado para uma coorte multicêntrica incluindo hospitais de referência no Brasil e em Moçambique. Recém-nascidos com peso de 500-2500 g serão elegíveis para inclusão com a melhor IG disponível, considerando os recursos limitados dos países de baixa renda. O Comparator-GA é baseado na datação confiável do último período menstrual ou na avaliação ultrassonográfica antes de 24 semanas de gestação. A IG estimada ao nascer (IGT-Teste) será calculada pela aplicação de um novo dispositivo optoeletrônico na pele do recém-nascido sobre a planta do pé. Será analisada a diferença média entre o Teste-GA e o Comparador-GA, assim como a porcentagem de recém-nascidos diagnosticados corretamente como pré-termo ou PIG. Além disso, em um estudo de caso-controle aninhado, será avaliada a precisão da reflexão da pele na previsão de problemas respiratórios relacionados à prematuridade. O tamanho amostral necessário estimado é de 298 recém-nascidos. Resultados: Equipes de profissionais de saúde foram treinadas e procedimentos operacionais padrão foram desenvolvidos seguindo as diretrizes de boas práticas para a investigação clínica de dispositivos médicos para participantes humanos. O primeiro recrutamento começou em março de 2019 no Brasil. A coleta de dados está planejada para terminar em dezembro de 2020, e os resultados devem estar disponíveis em março de 2021. Conclusões: Os resultados deste estudo clínico têm potencial para validar um novo dispositivo para avaliar facilmente a IG pós-natal, apoiando a identificação da PIG quando a datação da gravidez não é confiável ou desconhecido.
id UFMG_7922bf9a73b87c361d2842843f1956be
oai_identifier_str oai:repositorio.ufmg.br:1843/56728
network_acronym_str UFMG
network_name_str Repositório Institucional da UFMG
repository_id_str
spelling Premature or small for gestational age discrimination: international multicenter trial protocol for classification of the low-birth-weight newborn through the optical properties of the skinPrematuro ou pequeno para discriminação da idade gestacional: protocolo de ensaio multicêntrico internacional para classificação do recém-nascido de baixo peso por meio das propriedades ópticas da pelePrematurityFetal growth restrictionChildbirthSkin physiological phenomenaPhotomedicineEquipment and suppliesRecém-nascido prematuroRetardo do crescimento fetalPartoFenômenos fisiológicos da peleEquipamentos e provisõesIntrodução: O baixo peso ao nascer é um fator de risco independente para resultados adversos na infância e um preditor de doença crônica na vida adulta. Nessas situações, a diferenciação entre prematuridade e pequeno para a idade gestacional (PIG) ​​ou condições simultâneas é fundamental para garantir o cuidado adequado. Tais diagnósticos, no entanto, dependem de datações confiáveis ​​de gravidez, o que pode ser um desafio em países em desenvolvimento. Um novo dispositivo médico optoeletrônico foi desenvolvido para estimar a idade gestacional (IG) ao nascer com base na reflexão da pele do recém-nascido. Objetivo: Este estudo terá como objetivo avaliar a capacidade do dispositivo de detectar prematuridade ou PIG, ou ambas as condições simultaneamente, bem como prever complicações pulmonares de curto prazo em uma coorte de recém-nascidos de baixo peso. Métodos: Este protocolo de estudo foi desenhado para uma coorte multicêntrica incluindo hospitais de referência no Brasil e em Moçambique. Recém-nascidos com peso de 500-2500 g serão elegíveis para inclusão com a melhor IG disponível, considerando os recursos limitados dos países de baixa renda. O Comparator-GA é baseado na datação confiável do último período menstrual ou na avaliação ultrassonográfica antes de 24 semanas de gestação. A IG estimada ao nascer (IGT-Teste) será calculada pela aplicação de um novo dispositivo optoeletrônico na pele do recém-nascido sobre a planta do pé. Será analisada a diferença média entre o Teste-GA e o Comparador-GA, assim como a porcentagem de recém-nascidos diagnosticados corretamente como pré-termo ou PIG. Além disso, em um estudo de caso-controle aninhado, será avaliada a precisão da reflexão da pele na previsão de problemas respiratórios relacionados à prematuridade. O tamanho amostral necessário estimado é de 298 recém-nascidos. Resultados: Equipes de profissionais de saúde foram treinadas e procedimentos operacionais padrão foram desenvolvidos seguindo as diretrizes de boas práticas para a investigação clínica de dispositivos médicos para participantes humanos. O primeiro recrutamento começou em março de 2019 no Brasil. A coleta de dados está planejada para terminar em dezembro de 2020, e os resultados devem estar disponíveis em março de 2021. Conclusões: Os resultados deste estudo clínico têm potencial para validar um novo dispositivo para avaliar facilmente a IG pós-natal, apoiando a identificação da PIG quando a datação da gravidez não é confiável ou desconhecido.Background: A low birth weight is an independent risk factor for adverse infant outcomes and a predictor of chronic disease in adulthood. In these situations, differentiating between prematurity and small for gestational age (SGA) or simultaneous conditions is essential to ensuring adequate care. Such diagnoses, however, depend on reliable pregnancy dating, which can be challenging in developing countries. A new medical optoelectronic device was developed to estimate gestational age (GA) at birth based on newborn skin reflection. Objective: This study will aim to evaluate the device’s ability to detect prematurity or SGA, or both conditions simultaneously as well as predict short-term pulmonary complications in a cohort of low-birth-weight newborns. Methods: This study protocol was designed for a multicenter cohort including referral hospitals in Brazil and Mozambique. Newborns weighing 500-2500 g will be eligible for inclusion with the best GA available, considering the limited resources of low-income countries. Comparator-GA is based on reliable last menstrual period dating or ultrasound assessment before 24 weeks’ gestation. Estimated GA at birth (Test-GA) will be calculated by applying a novel optoelectronic device to the newborn’s skin over the sole. The average difference between Test-GA and Comparator-GA will be analyzed, as will the percentage of newborns who are correctly diagnosed as preterm or SGA. In addition, in a nested case–control study, the accuracy of skin reflection in the prediction of prematurity-related respiratory problems will be evaluated. The estimated required sample size is 298 newborns. Results: Teams of health professionals were trained, and standard operating procedures were developed following the good practice guidelines for the clinical investigation of medical devices for human participants. The first recruitment started in March 2019 in Brazil. Data collection is planned to end in December 2020, and the results should be available in March 2021. Conclusions: The results of this clinical study have the potential to validate a new device to easily assess postnatal GA, supporting SGA identification when pregnancy dating is unreliable or unknown.FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas GeraisCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível SuperiorOutra AgênciaUniversidade Federal de Minas GeraisBrasilICX - DEPARTAMENTO DE ESTATÍSTICAMED - DEPARTAMENTO DE GINECOLOGIA OBSTETRÍCIAMED - DEPARTAMENTO DE PEDIATRIAUFMG2023-07-19T18:05:43Z2023-07-19T18:05:43Z2020-07-14info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlepdfapplication/pdfhttps://doi.org/10.2196/164771929-0748http://hdl.handle.net/1843/56728https://orcid.org/0000-0001-6374-9295https://orcid.org/0000-0001-7306-8776https://orcid.org/0000-0001-5617-4470https://orcid.org/0000-0003-0670-9021https://orcid.org/0000-0001-8705-4674https://orcid.org/0000-0003-3848-2861https://orcid.org/0000-0002-0384-9574https://orcid.org/0000-0002-9299-3366https://orcid.org/0000-0002-7136-6240https://orcid.org/0000-0002-1660-0751engJMIR Research ProtocolsZilma Silveira Nogueira ReisGabriela Luiza Nogueira VitralRodney Nascimento GuimarãesJuliano de Souza GasparEnrico Antônio ColosimoSérgio Augusto TaundeNilza MussagyRita Rosado SantosDiogo Ayres-de-CamposRoberta Maia de Castro Romanelliinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFMGinstname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMG2023-07-19T18:05:43Zoai:repositorio.ufmg.br:1843/56728Repositório InstitucionalPUBhttps://repositorio.ufmg.br/oairepositorio@ufmg.bropendoar:2023-07-19T18:05:43Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)false
dc.title.none.fl_str_mv Premature or small for gestational age discrimination: international multicenter trial protocol for classification of the low-birth-weight newborn through the optical properties of the skin
Prematuro ou pequeno para discriminação da idade gestacional: protocolo de ensaio multicêntrico internacional para classificação do recém-nascido de baixo peso por meio das propriedades ópticas da pele
title Premature or small for gestational age discrimination: international multicenter trial protocol for classification of the low-birth-weight newborn through the optical properties of the skin
spellingShingle Premature or small for gestational age discrimination: international multicenter trial protocol for classification of the low-birth-weight newborn through the optical properties of the skin
Zilma Silveira Nogueira Reis
Prematurity
Fetal growth restriction
Childbirth
Skin physiological phenomena
Photomedicine
Equipment and supplies
Recém-nascido prematuro
Retardo do crescimento fetal
Parto
Fenômenos fisiológicos da pele
Equipamentos e provisões
title_short Premature or small for gestational age discrimination: international multicenter trial protocol for classification of the low-birth-weight newborn through the optical properties of the skin
title_full Premature or small for gestational age discrimination: international multicenter trial protocol for classification of the low-birth-weight newborn through the optical properties of the skin
title_fullStr Premature or small for gestational age discrimination: international multicenter trial protocol for classification of the low-birth-weight newborn through the optical properties of the skin
title_full_unstemmed Premature or small for gestational age discrimination: international multicenter trial protocol for classification of the low-birth-weight newborn through the optical properties of the skin
title_sort Premature or small for gestational age discrimination: international multicenter trial protocol for classification of the low-birth-weight newborn through the optical properties of the skin
author Zilma Silveira Nogueira Reis
author_facet Zilma Silveira Nogueira Reis
Gabriela Luiza Nogueira Vitral
Rodney Nascimento Guimarães
Juliano de Souza Gaspar
Enrico Antônio Colosimo
Sérgio Augusto Taunde
Nilza Mussagy
Rita Rosado Santos
Diogo Ayres-de-Campos
Roberta Maia de Castro Romanelli
author_role author
author2 Gabriela Luiza Nogueira Vitral
Rodney Nascimento Guimarães
Juliano de Souza Gaspar
Enrico Antônio Colosimo
Sérgio Augusto Taunde
Nilza Mussagy
Rita Rosado Santos
Diogo Ayres-de-Campos
Roberta Maia de Castro Romanelli
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Zilma Silveira Nogueira Reis
Gabriela Luiza Nogueira Vitral
Rodney Nascimento Guimarães
Juliano de Souza Gaspar
Enrico Antônio Colosimo
Sérgio Augusto Taunde
Nilza Mussagy
Rita Rosado Santos
Diogo Ayres-de-Campos
Roberta Maia de Castro Romanelli
dc.subject.por.fl_str_mv Prematurity
Fetal growth restriction
Childbirth
Skin physiological phenomena
Photomedicine
Equipment and supplies
Recém-nascido prematuro
Retardo do crescimento fetal
Parto
Fenômenos fisiológicos da pele
Equipamentos e provisões
topic Prematurity
Fetal growth restriction
Childbirth
Skin physiological phenomena
Photomedicine
Equipment and supplies
Recém-nascido prematuro
Retardo do crescimento fetal
Parto
Fenômenos fisiológicos da pele
Equipamentos e provisões
description Introdução: O baixo peso ao nascer é um fator de risco independente para resultados adversos na infância e um preditor de doença crônica na vida adulta. Nessas situações, a diferenciação entre prematuridade e pequeno para a idade gestacional (PIG) ​​ou condições simultâneas é fundamental para garantir o cuidado adequado. Tais diagnósticos, no entanto, dependem de datações confiáveis ​​de gravidez, o que pode ser um desafio em países em desenvolvimento. Um novo dispositivo médico optoeletrônico foi desenvolvido para estimar a idade gestacional (IG) ao nascer com base na reflexão da pele do recém-nascido. Objetivo: Este estudo terá como objetivo avaliar a capacidade do dispositivo de detectar prematuridade ou PIG, ou ambas as condições simultaneamente, bem como prever complicações pulmonares de curto prazo em uma coorte de recém-nascidos de baixo peso. Métodos: Este protocolo de estudo foi desenhado para uma coorte multicêntrica incluindo hospitais de referência no Brasil e em Moçambique. Recém-nascidos com peso de 500-2500 g serão elegíveis para inclusão com a melhor IG disponível, considerando os recursos limitados dos países de baixa renda. O Comparator-GA é baseado na datação confiável do último período menstrual ou na avaliação ultrassonográfica antes de 24 semanas de gestação. A IG estimada ao nascer (IGT-Teste) será calculada pela aplicação de um novo dispositivo optoeletrônico na pele do recém-nascido sobre a planta do pé. Será analisada a diferença média entre o Teste-GA e o Comparador-GA, assim como a porcentagem de recém-nascidos diagnosticados corretamente como pré-termo ou PIG. Além disso, em um estudo de caso-controle aninhado, será avaliada a precisão da reflexão da pele na previsão de problemas respiratórios relacionados à prematuridade. O tamanho amostral necessário estimado é de 298 recém-nascidos. Resultados: Equipes de profissionais de saúde foram treinadas e procedimentos operacionais padrão foram desenvolvidos seguindo as diretrizes de boas práticas para a investigação clínica de dispositivos médicos para participantes humanos. O primeiro recrutamento começou em março de 2019 no Brasil. A coleta de dados está planejada para terminar em dezembro de 2020, e os resultados devem estar disponíveis em março de 2021. Conclusões: Os resultados deste estudo clínico têm potencial para validar um novo dispositivo para avaliar facilmente a IG pós-natal, apoiando a identificação da PIG quando a datação da gravidez não é confiável ou desconhecido.
publishDate 2020
dc.date.none.fl_str_mv 2020-07-14
2023-07-19T18:05:43Z
2023-07-19T18:05:43Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.2196/16477
1929-0748
http://hdl.handle.net/1843/56728
https://orcid.org/0000-0001-6374-9295
https://orcid.org/0000-0001-7306-8776
https://orcid.org/0000-0001-5617-4470
https://orcid.org/0000-0003-0670-9021
https://orcid.org/0000-0001-8705-4674
https://orcid.org/0000-0003-3848-2861
https://orcid.org/0000-0002-0384-9574
https://orcid.org/0000-0002-9299-3366
https://orcid.org/0000-0002-7136-6240
https://orcid.org/0000-0002-1660-0751
url https://doi.org/10.2196/16477
http://hdl.handle.net/1843/56728
https://orcid.org/0000-0001-6374-9295
https://orcid.org/0000-0001-7306-8776
https://orcid.org/0000-0001-5617-4470
https://orcid.org/0000-0003-0670-9021
https://orcid.org/0000-0001-8705-4674
https://orcid.org/0000-0003-3848-2861
https://orcid.org/0000-0002-0384-9574
https://orcid.org/0000-0002-9299-3366
https://orcid.org/0000-0002-7136-6240
https://orcid.org/0000-0002-1660-0751
identifier_str_mv 1929-0748
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv JMIR Research Protocols
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv pdf
application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Minas Gerais
Brasil
ICX - DEPARTAMENTO DE ESTATÍSTICA
MED - DEPARTAMENTO DE GINECOLOGIA OBSTETRÍCIA
MED - DEPARTAMENTO DE PEDIATRIA
UFMG
publisher.none.fl_str_mv Universidade Federal de Minas Gerais
Brasil
ICX - DEPARTAMENTO DE ESTATÍSTICA
MED - DEPARTAMENTO DE GINECOLOGIA OBSTETRÍCIA
MED - DEPARTAMENTO DE PEDIATRIA
UFMG
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFMG
instname:Universidade Federal de Minas Gerais (UFMG)
instacron:UFMG
instname_str Universidade Federal de Minas Gerais (UFMG)
instacron_str UFMG
institution UFMG
reponame_str Repositório Institucional da UFMG
collection Repositório Institucional da UFMG
repository.name.fl_str_mv Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)
repository.mail.fl_str_mv repositorio@ufmg.br
_version_ 1823248063310856192