Detalhes bibliográficos
Título da fonte: Repositório Institucional da UFMG
id UFMG_ca830230e71cf8df96da8ea9a0a2d9ff
oai_identifier_str oai:repositorio.ufmg.br:1843/LMCA-7E6EYW
network_acronym_str UFMG
network_name_str Repositório Institucional da UFMG
repository_id_str
reponame_str Repositório Institucional da UFMG
instacron_str UFMG
institution Universidade Federal de Minas Gerais (UFMG)
instname_str Universidade Federal de Minas Gerais (UFMG)
spelling Ney Amorim SilvaArmando Cesar Campos LavallAlcebiades de Vasconcelos FilhoJoão Batista Marques de Sousa JuniorJosé Samuel GiongoDanielle Meireles de Oliveira2019-08-10T04:51:46Z2019-08-10T04:51:46Z2007-08-24http://hdl.handle.net/1843/LMCA-7E6EYWNeste trabalho estudam-se os processos aproximados usualmente empregados para a consideração das não-linearidades física e geométrica na análise global das estruturas de concreto armado. Assim, diversos pórticos planos e edifícios de médio porte são processados utilizando o programa ANSYS. Os resultados obtidos permitiram determinar quais valores de redução de inércia, dentre aqueles recomendados pela NBR 6118:2003 e segundo a formulação de BRANSON (1966), melhor representam o comportamento real das estruturas. Verificou-se que, no estado limite de serviço, a análise que reduz em 20% a rigidez dos pilares e utiliza a inércia equivalente de BRANSON (1966) para as vigas pôde ser considerada a mais eficiente. Para o carregamento sem majoração e o correspondente ao estado limite último, a utilização dos valores de redução de inércia adotados pela NBR 6118:2003 para os casos mais gerais se mostrou a mais apropriada. Realiza-se também uma avaliação da eficiência do coeficiente gz como majorador dos esforços de primeira ordem (momentos fletores, forças normais e cortantes) e como majorador dasações horizontais, para a obtenção dos esforços finais, que incluem os de segunda ordem. Constatou-se que o coeficiente gz deve ser utilizado como majorador dos momentos de primeira ordem (e não das ações horizontais) para a obtenção dos momentos finais. No caso da força normal nos pilares e da força cortante nas vigas, a majoração pelo coeficiente gz não se faz necessária, uma vez que, para estes esforços, os valores obtidos em primeira e em segunda ordem são praticamente os mesmos. Finalmente, o processo simplificado de avaliação dos momentos finais utilizando o coeficiente gz como majorador dos momentos de primeira ordem é estudado levando-se em conta a variação dos efeitos de segunda ordem ao longo da altura dos edifícios.In this work, the simplified methods generally used to take into account physical and geometric non-linearities in reinforced concrete structures global analysis are studied. With this purpose, several plane frames and buildings of medium height are analysed using ANSYS software. The results provided which inertia reduction values, among thoserecommended by Brazilian Code, NBR 6118:2003, and BRANSON (1966) formulation, better represent the actual behavior of the structures. At the service limit state, the analysis that reduces the stiffness of columns in 20% and uses BRANSON (1966) equivalent inertia for beams was considered the most efficient. For the unfactored loading and at the ultimate limit state, the use of inertia reduction values recommended byNBR 6118:2003 for the most general cases showed to be the most appropriated. The accuracy of gz coefficient as magnifier of first order efforts (bending moments, axial and shearing forces) and as magnifier of horizontal loads to evaluate final second order efforts is also studied. It was checked that the gz coefficient should be used as magnifier of firstorder moments (and not for horizontal loads) to evaluate final second order moments. In case of axial force in columns and shearing force in beams, the magnification by gz coefficient is not necessary, since that, for these efforts, the values obtained in first and in second order analysis are almost the same. Finally, the simplified method to evaluate finalsecond order moments using the gz coefficient as magnifier of first order moments is studied considering the variation of the second order effects with the height of the buildings.Universidade Federal de Minas GeraisUFMGEngenharia de estruturasConcreto armadoAnálise global das estruturas de concreto armadoPrograma ANSYSEstudo dos processos aproximados utilizados para a consideração das não-linearidades física e geométrica na análise global das estruturas de concreto armadoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessporreponame:Repositório Institucional da UFMGinstname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMGORIGINALtesefinal.pdfapplication/pdf1962545https://repositorio.ufmg.br/bitstream/1843/LMCA-7E6EYW/1/tesefinal.pdff182484b1d25863972fc4076914c61d1MD51TEXTtesefinal.pdf.txttesefinal.pdf.txtExtracted texttext/plain488265https://repositorio.ufmg.br/bitstream/1843/LMCA-7E6EYW/2/tesefinal.pdf.txt82a7e837003ac9d3c0d36109d09915c0MD521843/LMCA-7E6EYW2019-11-14 07:34:43.406oai:repositorio.ufmg.br:1843/LMCA-7E6EYWRepositório InstitucionalPUBhttps://repositorio.ufmg.br/oaiopendoar:2019-11-14T10:34:43Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)false
_version_ 1813547654760628224