Detalhes bibliográficos
Título da fonte: Repositório Institucional da UFMG
id UFMG_eedb88acec6027540a067f1463d5ad53
oai_identifier_str oai:repositorio.ufmg.br:1843/RAOA-BB4K94
network_acronym_str UFMG
network_name_str Repositório Institucional da UFMG
repository_id_str
reponame_str Repositório Institucional da UFMG
instacron_str UFMG
institution Universidade Federal de Minas Gerais (UFMG)
instname_str Universidade Federal de Minas Gerais (UFMG)
spelling Estevam Barbosa de Las CasasEduardo Jose Lima IIMarina Spyer Las-casas2019-08-11T16:27:01Z2019-08-11T16:27:01Z2018-10-16http://hdl.handle.net/1843/RAOA-BB4K94O objetivo deste estudo é projetar e construir um novo aspirador de secreção pulmonar com oxigenação e umidificação das vias aéreas, de baixo custo, fácil utilização, para procedimento realizado em sistema aberto, uso residencial ou hospitalar. O novo aspirador pretende tornar o procedimento mais seguro e menos desconfortável para o paciente e facilitar a execução do procedimento que requer experiência e habilidade do profissional que o executa. O novo equipamento permite a configuração do modo de sucção que pode ser contínuo ou alternado, do tempo do procedimento que não pode ser maior que 15 segundos e no caso do modo de sucção alternado o tempo que o vácuo fica aberto e fechado. Com a umidificação pretende-se fluidificar a secreção e facilitar a sua retirada, assim como ocorre na prática de instilação de solução salina, sem que haja a queda da oxigenação e aumento do risco de infecção que estão relacionados por essa prática. Com a oxigenação pretende-se atenuar o risco de hipoxemia, compensando o ar que inevitavelmente é retirado das vias aéreas do paciente durante o procedimento. O estudo da dinâmica dos fluidos dentro da sonda de um lúmen foi realizado utilizando o programa Ansys Fluent e validado por testes de bancada, para identificar quais são os pontos importantes de projeto que levam a um cateter eficiente e com menor chance de lesão ao paciente. Neste estudo foram consideradas diferentes pressões e propriedades do muco. Para os testes de bancada foram utilizados mimetizadores de muco viscoelásticos elaborados a partir do polietilenoglicol, com peso molecular de 5.000.000 g/mol, caracterizados por meio de um reômetro TA Intruments ARG2. A perda de carga mais significativa para o cateter é a perda de carga distribuída, portanto, o cateter deve ter o menor comprimento possível. Entretanto, quando a redução do comprimento do cateter não é mais possível, maiores áreas para entrada da secreção, orifícios laterais desalinhados e menor quantidade de orifícios aumenta a eficiência do cateterThe objective of this study is to design and assemble a new suction machine for endotracheal aspiration with oxygenation and humidification of the airways, low cost, easy to use, for open suctioning, residential or hospital use. The new suction machine intends to make the procedure safer and less uncomfortable for the patient and to facilitate the execution of the procedure that requires experience and skill of the professional who performs it. The new equipment allows the configuration of the suction mode which can be continuous or alternating, of the procedure time which cannot last longer than 15 seconds and in the case of the suction mode alternating the opened and closed vacuum time. With the humidification it is intended to fluidize the secretion and facilitate its removal, similarly to what occurs with the use of saline instillation, without the reduction in oxygenation and increased risk of infection that are related to this practice. With oxygenation it is intended to attenuate the risk of hypoxemia. offsetting the air which is inevitably removed from the patient's airway during the procedure. The fluid dynamics study within the one lumen catheter was performed using the Ansys Fluent program and validated by bench tests, to identify the important design points that lead to an efficient catheter and with less chance of patient injury. In this study, different pressures and mucus properties were considered. For the bench tests were used viscoelastics mucus simulators made from polyethylene glycol with molecular weight of 5,000,000 g/mol solutions, characterized by a TA Intruments ARG2 rheometer. The most significant pressure drop for the catheter is the distributed pressure drop, so the catheter should be as short as possible. However, when reduction of catheter length is no longer possible, larger areas for secretion entry, misaligned lateral orifices and fewer orifices increase catheter efficiencyUniversidade Federal de Minas GeraisUFMGSucçãoBiomecânicaPulmões SecreçõesReologiaEngenharia mecânicaMucoCFDSucçãoPulmãoReologiaCateterMateriais biomiméticosDesenvolvimento de um novo aspirador de secreção pulmonar com oxigenação e umidificaçãoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessporreponame:Repositório Institucional da UFMGinstname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMGORIGINALlas_casas_m.s._tese.pdfapplication/pdf2250913https://repositorio.ufmg.br/bitstream/1843/RAOA-BB4K94/1/las_casas_m.s._tese.pdff42444086f33baf0f9e364b376b71428MD51TEXTlas_casas_m.s._tese.pdf.txtlas_casas_m.s._tese.pdf.txtExtracted texttext/plain173617https://repositorio.ufmg.br/bitstream/1843/RAOA-BB4K94/2/las_casas_m.s._tese.pdf.txte75b4b6e6e0cdd8be64621a0a4f78f76MD521843/RAOA-BB4K942019-11-14 08:47:22.806oai:repositorio.ufmg.br:1843/RAOA-BB4K94Repositório InstitucionalPUBhttps://repositorio.ufmg.br/oaiopendoar:2019-11-14T11:47:22Repositório Institucional da UFMG - Universidade Federal de Minas Gerais (UFMG)false
_version_ 1813547282899927040