Desenvolvimento de um Sensor de Deformação a Base de Óxido de Grafeno Reduzido sobre Substrato Flexível

Detalhes bibliográficos
Autor(a) principal: Felipe Alencar Motta
Data de Publicação: 2021
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFMS
Texto Completo: https://repositorio.ufms.br/handle/123456789/4263
Resumo: This work is based on the development and study about an strain sensor based on reduced graphene oxide (rGO) deposited on a flexible polydimethylsiloxane (PDMS) substrate. It also consists of studying the effect of the addition of biogenic silica nanoparticles to the rGO film and further investigation of the new sensor’s performance. To obtain biogenic nanosilica, calcination methods combined with acid leaching, and manual grinding combined with sonochemical erosion were used. The rGO sensors were produced by an automated spray-coating method, with subsequent termal-laser reduction. To carry out the deformation tests, an electromechanical equipment was developed which, mounted with a dial indicator, made it possible to automatically control the applied stretches. The morphological and chemical characterizations of the GO and rGO films were performed via scanning electron microscopy, energy dispersion X-ray spectroscopy, and X-ray diffraction. Electrical measurements showed that the produced rGO sensors exhibit high strain sensitivity, were the highest gauge factor (GF) observed was 185 in a deformation range of 0 to 4%, with nonlinear response. Sensors decorated with silica particles did not show a measurable response to this strain range, as they resulted in an insulating material, probably due to the excess of silica added to the GO matrix.
id UFMS_326e8d8b8b8f4799be29fe5f8f63b2b5
oai_identifier_str oai:repositorio.ufms.br:123456789/4263
network_acronym_str UFMS
network_name_str Repositório Institucional da UFMS
repository_id_str 2124
spelling 2022-01-10T13:15:15Z2022-01-10T13:15:15Z2021https://repositorio.ufms.br/handle/123456789/4263This work is based on the development and study about an strain sensor based on reduced graphene oxide (rGO) deposited on a flexible polydimethylsiloxane (PDMS) substrate. It also consists of studying the effect of the addition of biogenic silica nanoparticles to the rGO film and further investigation of the new sensor’s performance. To obtain biogenic nanosilica, calcination methods combined with acid leaching, and manual grinding combined with sonochemical erosion were used. The rGO sensors were produced by an automated spray-coating method, with subsequent termal-laser reduction. To carry out the deformation tests, an electromechanical equipment was developed which, mounted with a dial indicator, made it possible to automatically control the applied stretches. The morphological and chemical characterizations of the GO and rGO films were performed via scanning electron microscopy, energy dispersion X-ray spectroscopy, and X-ray diffraction. Electrical measurements showed that the produced rGO sensors exhibit high strain sensitivity, were the highest gauge factor (GF) observed was 185 in a deformation range of 0 to 4%, with nonlinear response. Sensors decorated with silica particles did not show a measurable response to this strain range, as they resulted in an insulating material, probably due to the excess of silica added to the GO matrix.O objetivo deste trabalho consiste no desenvolvimento e estudo de um sensor de deformação mecânica à base de óxido de grafeno reduzido (OGr) depositado sobre substrato flexível de polidimetilsiloxano (PDMS). Consiste, ainda, no estudo do efeito da adição de nanopartículas de sílica biogênica no filme de OGr e posterior investigação do desempenho do novo sensor. Para a obtenção da nanosílica biogênica, foram utilizados métodos de calcinação combinada com lixiviação ácida, e moagem manual combinada com erosão sonoquímica. Os sensores de OGr foram produzidos pelo método de spray coating automatizado, com posterior redução térmica a laser. Para realização dos testes de deformação, foi desenvolvido um equipamento eletromecânico que, montado com um relógio comparador, possibilitou controlar de forma automatizada os alongamentos aplicados. As caracterizações morfológicas e químicas dos filmes de OG e OGr foram realizadas via microscopia eletrônica de varredura, espectroscopia de raios-X por dispersão em energia, e difração de raios-x. Medidas elétricas realizadas mostraram que os sensores de OGr produzidos apresentaram alta sensibilidade à deformação, sendo que o maior fator de ganho (FG) observado foi de 185 em uma faixa de deformação de 0 a 4%, com resposta não linear. Os sensores decorados com partículas de sílica não apresentaram resposta mensurável à essa faixa de deformação, pois resultaram em um material isolante, provavelmente devido ao excesso de sílica adicionado à matriz de OG.Fundação Universidade Federal de Mato Grosso do SulUFMSBrasilciência dos materiaisDesenvolvimento de um Sensor de Deformação a Base de Óxido de Grafeno Reduzido sobre Substrato Flexívelinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisDiogo Duarte dos ReisFelipe Alencar Mottainfo:eu-repo/semantics/openAccessporreponame:Repositório Institucional da UFMSinstname:Universidade Federal de Mato Grosso do Sul (UFMS)instacron:UFMSTHUMBNAILDissertação_FelipeAlencar_Final.pdf.jpgDissertação_FelipeAlencar_Final.pdf.jpgGenerated Thumbnailimage/jpeg1328https://repositorio.ufms.br/bitstream/123456789/4263/3/Disserta%c3%a7%c3%a3o_FelipeAlencar_Final.pdf.jpgca4a3b19fedbca2511b8331a39c37b68MD53TEXTDissertação_FelipeAlencar_Final.pdf.txtDissertação_FelipeAlencar_Final.pdf.txtExtracted texttext/plain196353https://repositorio.ufms.br/bitstream/123456789/4263/2/Disserta%c3%a7%c3%a3o_FelipeAlencar_Final.pdf.txt743fcb45e52309438bbfb8da4e0c439aMD52ORIGINALDissertação_FelipeAlencar_Final.pdfDissertação_FelipeAlencar_Final.pdfapplication/pdf11863425https://repositorio.ufms.br/bitstream/123456789/4263/1/Disserta%c3%a7%c3%a3o_FelipeAlencar_Final.pdf3c0976f3f951dcd208efb6ac4989e177MD51123456789/42632022-01-11 03:02:34.267oai:repositorio.ufms.br:123456789/4263Repositório InstitucionalPUBhttps://repositorio.ufms.br/oai/requestri.prograd@ufms.bropendoar:21242022-01-11T07:02:34Repositório Institucional da UFMS - Universidade Federal de Mato Grosso do Sul (UFMS)false
dc.title.pt_BR.fl_str_mv Desenvolvimento de um Sensor de Deformação a Base de Óxido de Grafeno Reduzido sobre Substrato Flexível
title Desenvolvimento de um Sensor de Deformação a Base de Óxido de Grafeno Reduzido sobre Substrato Flexível
spellingShingle Desenvolvimento de um Sensor de Deformação a Base de Óxido de Grafeno Reduzido sobre Substrato Flexível
Felipe Alencar Motta
ciência dos materiais
title_short Desenvolvimento de um Sensor de Deformação a Base de Óxido de Grafeno Reduzido sobre Substrato Flexível
title_full Desenvolvimento de um Sensor de Deformação a Base de Óxido de Grafeno Reduzido sobre Substrato Flexível
title_fullStr Desenvolvimento de um Sensor de Deformação a Base de Óxido de Grafeno Reduzido sobre Substrato Flexível
title_full_unstemmed Desenvolvimento de um Sensor de Deformação a Base de Óxido de Grafeno Reduzido sobre Substrato Flexível
title_sort Desenvolvimento de um Sensor de Deformação a Base de Óxido de Grafeno Reduzido sobre Substrato Flexível
author Felipe Alencar Motta
author_facet Felipe Alencar Motta
author_role author
dc.contributor.advisor1.fl_str_mv Diogo Duarte dos Reis
dc.contributor.author.fl_str_mv Felipe Alencar Motta
contributor_str_mv Diogo Duarte dos Reis
dc.subject.por.fl_str_mv ciência dos materiais
topic ciência dos materiais
description This work is based on the development and study about an strain sensor based on reduced graphene oxide (rGO) deposited on a flexible polydimethylsiloxane (PDMS) substrate. It also consists of studying the effect of the addition of biogenic silica nanoparticles to the rGO film and further investigation of the new sensor’s performance. To obtain biogenic nanosilica, calcination methods combined with acid leaching, and manual grinding combined with sonochemical erosion were used. The rGO sensors were produced by an automated spray-coating method, with subsequent termal-laser reduction. To carry out the deformation tests, an electromechanical equipment was developed which, mounted with a dial indicator, made it possible to automatically control the applied stretches. The morphological and chemical characterizations of the GO and rGO films were performed via scanning electron microscopy, energy dispersion X-ray spectroscopy, and X-ray diffraction. Electrical measurements showed that the produced rGO sensors exhibit high strain sensitivity, were the highest gauge factor (GF) observed was 185 in a deformation range of 0 to 4%, with nonlinear response. Sensors decorated with silica particles did not show a measurable response to this strain range, as they resulted in an insulating material, probably due to the excess of silica added to the GO matrix.
publishDate 2021
dc.date.issued.fl_str_mv 2021
dc.date.accessioned.fl_str_mv 2022-01-10T13:15:15Z
dc.date.available.fl_str_mv 2022-01-10T13:15:15Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://repositorio.ufms.br/handle/123456789/4263
url https://repositorio.ufms.br/handle/123456789/4263
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Fundação Universidade Federal de Mato Grosso do Sul
dc.publisher.initials.fl_str_mv UFMS
dc.publisher.country.fl_str_mv Brasil
publisher.none.fl_str_mv Fundação Universidade Federal de Mato Grosso do Sul
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFMS
instname:Universidade Federal de Mato Grosso do Sul (UFMS)
instacron:UFMS
instname_str Universidade Federal de Mato Grosso do Sul (UFMS)
instacron_str UFMS
institution UFMS
reponame_str Repositório Institucional da UFMS
collection Repositório Institucional da UFMS
bitstream.url.fl_str_mv https://repositorio.ufms.br/bitstream/123456789/4263/3/Disserta%c3%a7%c3%a3o_FelipeAlencar_Final.pdf.jpg
https://repositorio.ufms.br/bitstream/123456789/4263/2/Disserta%c3%a7%c3%a3o_FelipeAlencar_Final.pdf.txt
https://repositorio.ufms.br/bitstream/123456789/4263/1/Disserta%c3%a7%c3%a3o_FelipeAlencar_Final.pdf
bitstream.checksum.fl_str_mv ca4a3b19fedbca2511b8331a39c37b68
743fcb45e52309438bbfb8da4e0c439a
3c0976f3f951dcd208efb6ac4989e177
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFMS - Universidade Federal de Mato Grosso do Sul (UFMS)
repository.mail.fl_str_mv ri.prograd@ufms.br
_version_ 1815447978356244480