Tratamento de efluente de frigorífico bovino utilizando a técnica de eletrocoagulação
Autor(a) principal: | |
---|---|
Data de Publicação: | 2023 |
Tipo de documento: | Trabalho de conclusão de curso |
Idioma: | por |
Título da fonte: | Biblioteca Digital de Monografias da UFMT |
Texto Completo: | http://bdm.ufmt.br/handle/1/3281 |
Resumo: | In recent years, a significant growth in industrial demand has been observed, mainly in the processed food industry. However, this increase in production, especially in the meat processing industries, has resulted in a negative consequence: the generation of solid and liquid waste, which often represent a potential source of pollution for water bodies. In view of this, these wastewaters must receive appropriate treatment before being released into rivers. In this context, the electrocoagulation technique has been gaining prominence as an alternative for the treatment of agro-industrial effluents. In the study presented, the use of this technique was evaluated in the treatment of effluent from a bovine slaughterhouse, using mixed aluminum and graphite electrodes. In a first step, with the aluminum electrode connected to the positive pole (anode), the influence of the variables potential, time and distance between electrodes on color removal and ultraviolet absorbance at 254 nm (UV254nm) was studied. After optimizing these variables, a study was carried out comparing the efficiency in the treatment of the effluent, inverting the polarity of the electrodes. Therefore, in addition to the evaluation of color removal and UV254nm, analyzes of total solids, Imhoff Cone, Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD) were carried out. Using aluminum as the anode, the best results for color removal (87.27%) and absorbance (88.8%) were achieved using a power of 25.0 V, in a time of 90 min and distance of 0.5 cm between electrodes. In addition, an efficient removal of COD (55.02%) and BOD (82.30%) was obtained. The results obtained by reversing the polarities of the electrodes (aluminum as cathode) were also promising, but a little less efficient in removing parameters. However, for purposes of operational cost analysis, the application of the technique using the aluminum electrode on the cathode proved to be more economically viable. This study proves that the electrocoagulation technique can become an alternative with low installation and operating costs for the treatment of effluents from slaughterhouses. |
id |
UFMT-1_95fb82362c0f533a9f2a45bcdb498773 |
---|---|
oai_identifier_str |
oai:localhost:1/3281 |
network_acronym_str |
UFMT-1 |
network_name_str |
Biblioteca Digital de Monografias da UFMT |
repository_id_str |
|
spelling |
Tratamento de efluente de frigorífico bovino utilizando a técnica de eletrocoagulaçãoCNPQ::CIENCIAS AGRARIAS::ENGENHARIA AGRICOLAAlumínioCarbono grafiteEfluenteEletrocoagulaçãoAluminumCarbon graphiteEffluentElectrocoagulationIn recent years, a significant growth in industrial demand has been observed, mainly in the processed food industry. However, this increase in production, especially in the meat processing industries, has resulted in a negative consequence: the generation of solid and liquid waste, which often represent a potential source of pollution for water bodies. In view of this, these wastewaters must receive appropriate treatment before being released into rivers. In this context, the electrocoagulation technique has been gaining prominence as an alternative for the treatment of agro-industrial effluents. In the study presented, the use of this technique was evaluated in the treatment of effluent from a bovine slaughterhouse, using mixed aluminum and graphite electrodes. In a first step, with the aluminum electrode connected to the positive pole (anode), the influence of the variables potential, time and distance between electrodes on color removal and ultraviolet absorbance at 254 nm (UV254nm) was studied. After optimizing these variables, a study was carried out comparing the efficiency in the treatment of the effluent, inverting the polarity of the electrodes. Therefore, in addition to the evaluation of color removal and UV254nm, analyzes of total solids, Imhoff Cone, Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD) were carried out. Using aluminum as the anode, the best results for color removal (87.27%) and absorbance (88.8%) were achieved using a power of 25.0 V, in a time of 90 min and distance of 0.5 cm between electrodes. In addition, an efficient removal of COD (55.02%) and BOD (82.30%) was obtained. The results obtained by reversing the polarities of the electrodes (aluminum as cathode) were also promising, but a little less efficient in removing parameters. However, for purposes of operational cost analysis, the application of the technique using the aluminum electrode on the cathode proved to be more economically viable. This study proves that the electrocoagulation technique can become an alternative with low installation and operating costs for the treatment of effluents from slaughterhouses.Nos últimos anos, tem sido observado um crescimento expressivo na demanda industrial, principalmente na indústria de alimentos processados. No entanto, esse aumento na produção, especialmente nas indústrias de processamento de carnes, tem acarretado em uma consequência negativa: a geração de resíduos sólidos e líquidos, que frequentemente representam um potencial de poluição para corpos d'água. Diante disso, essas águas residuárias devem receber tratamento apropriado antes do seu lançamento nos rios. Nesse contexto, a técnica da eletrocoagulação vem ganhando destaque como uma alternativa para tratamento de efluentes agroindustriais. No estudo apresentado, avaliou-se o emprego desta técnica no tratamento de efluente proveniente de abatedouro bovino, utilizando-se eletrodos mistos de alumínio e grafite. Numa primeira etapa, com o eletrodo de alumínio ligado ao polo positivo (ânodo), estudou-se a influência das variáveis potencial, tempo e distância entre eletrodos na remoção de cor e absorbância ultravioleta em 254 nm (UV254nm). Após a otimização dessas variáveis, realizou-se um estudo comparando a eficiência no tratamento do efluente, invertendo-se a polaridade dos eletrodos. Para tanto, além da avaliação na remoção de cor e UV254nm, foram realizadas análises de sólidos totais, Cone Imhoff, Demanda Química de Oxigênio (DQO) e Demanda Bioquímica de Oxigênio (DBO). Utilizando-se o alumínio como ânodo, os melhores resultados para remoção de cor (87,27%) e absorbância (88,8%) foram alcançados com o uso de uma potência de 25,0 V, em um tempo de 90 min e distância de 0,5 cm entre eletrodos. Além disso, obteve-se uma remoção eficiente de DQO (55,02%) e DBO (82,30%). Os resultados obtidos invertendo-se as polaridades dos eletrodos (alumínio como cátodo), também se mostraram promissores, porém um pouco menos eficiente na remoção dos parâmetros. No entanto, para fins de análise de custo operacional, a aplicação da técnica utilizando o eletrodo de alumínio no cátodo, apresentou-se mais viável economicamente. Através desse estudo comprova-se que a técnica de eletrocoagulação pode se tornar uma alternativa com baixo custo de instalação e operação para o tratamento de efluentes de abatedouros.Universidade Federal de Mato GrossoBrasilInstituto de Ciências Agrárias e Ambientais (ICAA) – SinopUFMT CUS - SinopEngenharia Agrícola e Ambiental - CUSMattos, Luciana Vieirahttp://lattes.cnpq.br/8138348622472033Mattos, Luciana Vieirahttp://lattes.cnpq.br/8138348622472033Carvalho, Marcos Fernandes dehttp://lattes.cnpq.br/0922916090536806Oliveira, Tânia Lopes dehttp://lattes.cnpq.br/8062887421542885Pereira, Victor Mateus Ponte2023-07-12T22:05:48Z2023-06-132023-07-12T22:05:48Z2023-05-13info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisinfo:eu-repo/semantics/datasetPEREIRA, Victor Mateus Ponte. Tratamento de efluente de frigorífico bovino utilizando a técnica de eletrocoagulação. 2022. 44f. Trabalho de Conclusão de Curso (Graduação em Engenharia Agrícola e Ambiental) – Universidade Federal de Mato Grosso, Instituto de Ciências Agrárias e Ambientais, Sinop, 2022.http://bdm.ufmt.br/handle/1/3281porinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Monografias da UFMTinstname:Universidade Federal de Mato Grosso (UFMT)instacron:UFMT2023-07-16T07:04:04Zoai:localhost:1/3281Biblioteca Digital de Monografiahttps://bdm.ufmt.br/PUBhttp://200.129.241.122/oai/requestopendoar:2023-07-16T07:04:04falseBiblioteca Digital de Monografiahttps://bdm.ufmt.br/PUBhttp://200.129.241.122/oai/requestbibliotecacentral@ufmt.br||opendoar:2023-07-16T07:04:04Biblioteca Digital de Monografias da UFMT - Universidade Federal de Mato Grosso (UFMT)false |
dc.title.none.fl_str_mv |
Tratamento de efluente de frigorífico bovino utilizando a técnica de eletrocoagulação |
title |
Tratamento de efluente de frigorífico bovino utilizando a técnica de eletrocoagulação |
spellingShingle |
Tratamento de efluente de frigorífico bovino utilizando a técnica de eletrocoagulação Pereira, Victor Mateus Ponte CNPQ::CIENCIAS AGRARIAS::ENGENHARIA AGRICOLA Alumínio Carbono grafite Efluente Eletrocoagulação Aluminum Carbon graphite Effluent Electrocoagulation |
title_short |
Tratamento de efluente de frigorífico bovino utilizando a técnica de eletrocoagulação |
title_full |
Tratamento de efluente de frigorífico bovino utilizando a técnica de eletrocoagulação |
title_fullStr |
Tratamento de efluente de frigorífico bovino utilizando a técnica de eletrocoagulação |
title_full_unstemmed |
Tratamento de efluente de frigorífico bovino utilizando a técnica de eletrocoagulação |
title_sort |
Tratamento de efluente de frigorífico bovino utilizando a técnica de eletrocoagulação |
author |
Pereira, Victor Mateus Ponte |
author_facet |
Pereira, Victor Mateus Ponte |
author_role |
author |
dc.contributor.none.fl_str_mv |
Mattos, Luciana Vieira http://lattes.cnpq.br/8138348622472033 Mattos, Luciana Vieira http://lattes.cnpq.br/8138348622472033 Carvalho, Marcos Fernandes de http://lattes.cnpq.br/0922916090536806 Oliveira, Tânia Lopes de http://lattes.cnpq.br/8062887421542885 |
dc.contributor.author.fl_str_mv |
Pereira, Victor Mateus Ponte |
dc.subject.por.fl_str_mv |
CNPQ::CIENCIAS AGRARIAS::ENGENHARIA AGRICOLA Alumínio Carbono grafite Efluente Eletrocoagulação Aluminum Carbon graphite Effluent Electrocoagulation |
topic |
CNPQ::CIENCIAS AGRARIAS::ENGENHARIA AGRICOLA Alumínio Carbono grafite Efluente Eletrocoagulação Aluminum Carbon graphite Effluent Electrocoagulation |
description |
In recent years, a significant growth in industrial demand has been observed, mainly in the processed food industry. However, this increase in production, especially in the meat processing industries, has resulted in a negative consequence: the generation of solid and liquid waste, which often represent a potential source of pollution for water bodies. In view of this, these wastewaters must receive appropriate treatment before being released into rivers. In this context, the electrocoagulation technique has been gaining prominence as an alternative for the treatment of agro-industrial effluents. In the study presented, the use of this technique was evaluated in the treatment of effluent from a bovine slaughterhouse, using mixed aluminum and graphite electrodes. In a first step, with the aluminum electrode connected to the positive pole (anode), the influence of the variables potential, time and distance between electrodes on color removal and ultraviolet absorbance at 254 nm (UV254nm) was studied. After optimizing these variables, a study was carried out comparing the efficiency in the treatment of the effluent, inverting the polarity of the electrodes. Therefore, in addition to the evaluation of color removal and UV254nm, analyzes of total solids, Imhoff Cone, Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD) were carried out. Using aluminum as the anode, the best results for color removal (87.27%) and absorbance (88.8%) were achieved using a power of 25.0 V, in a time of 90 min and distance of 0.5 cm between electrodes. In addition, an efficient removal of COD (55.02%) and BOD (82.30%) was obtained. The results obtained by reversing the polarities of the electrodes (aluminum as cathode) were also promising, but a little less efficient in removing parameters. However, for purposes of operational cost analysis, the application of the technique using the aluminum electrode on the cathode proved to be more economically viable. This study proves that the electrocoagulation technique can become an alternative with low installation and operating costs for the treatment of effluents from slaughterhouses. |
publishDate |
2023 |
dc.date.none.fl_str_mv |
2023-07-12T22:05:48Z 2023-06-13 2023-07-12T22:05:48Z 2023-05-13 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/bachelorThesis info:eu-repo/semantics/dataset |
format |
bachelorThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
PEREIRA, Victor Mateus Ponte. Tratamento de efluente de frigorífico bovino utilizando a técnica de eletrocoagulação. 2022. 44f. Trabalho de Conclusão de Curso (Graduação em Engenharia Agrícola e Ambiental) – Universidade Federal de Mato Grosso, Instituto de Ciências Agrárias e Ambientais, Sinop, 2022. http://bdm.ufmt.br/handle/1/3281 |
identifier_str_mv |
PEREIRA, Victor Mateus Ponte. Tratamento de efluente de frigorífico bovino utilizando a técnica de eletrocoagulação. 2022. 44f. Trabalho de Conclusão de Curso (Graduação em Engenharia Agrícola e Ambiental) – Universidade Federal de Mato Grosso, Instituto de Ciências Agrárias e Ambientais, Sinop, 2022. |
url |
http://bdm.ufmt.br/handle/1/3281 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Universidade Federal de Mato Grosso Brasil Instituto de Ciências Agrárias e Ambientais (ICAA) – Sinop UFMT CUS - Sinop Engenharia Agrícola e Ambiental - CUS |
publisher.none.fl_str_mv |
Universidade Federal de Mato Grosso Brasil Instituto de Ciências Agrárias e Ambientais (ICAA) – Sinop UFMT CUS - Sinop Engenharia Agrícola e Ambiental - CUS |
dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Monografias da UFMT instname:Universidade Federal de Mato Grosso (UFMT) instacron:UFMT |
instname_str |
Universidade Federal de Mato Grosso (UFMT) |
instacron_str |
UFMT |
institution |
UFMT |
reponame_str |
Biblioteca Digital de Monografias da UFMT |
collection |
Biblioteca Digital de Monografias da UFMT |
repository.name.fl_str_mv |
Biblioteca Digital de Monografias da UFMT - Universidade Federal de Mato Grosso (UFMT) |
repository.mail.fl_str_mv |
bibliotecacentral@ufmt.br|| |
_version_ |
1813012969968107520 |