Optimization of a homogeneous ternary solvent system for the quantification of lead in crystal sugar samples.

Detalhes bibliográficos
Autor(a) principal: Chagas, Júnior Olair
Data de Publicação: 2017
Outros Autores: Corrêa, Silviana, Melo, Isabela Cristina Silva, Lobo, Fabiana Aparecida, Almeida, Alex Magalhães de
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UFOP
Texto Completo: http://www.repositorio.ufop.br/handle/123456789/9954
Resumo: During sugar production, contamination of the sugar by potentially toxic metals may occur. Therefore, it is necessary to develop methods to quantify these contaminants. Analytical method for monitoring of lead in sugar samples was developed with the use of homogeneous ternary system of solvents and UV-Vis spectrophotometry. Ternary system was optimized using multivariate experiments and the best condition was: 10% water, 80% ethanol and 10% methyl isobutyl ketone. As the complexing agent, monosodium 4-(2-pyridylazo) resorcinol used. Calibration curve was linear from 0.64 to 5.00 mg L-1, ABS = 0.0873 [Pb2 +] - 0.0032 and R² = 0.9988. The limit of quantification was 0.53 mg L-1 and limit of detection was 0.45 mg L-1 with 95% confidence level, the standard addition curve was linear, ABS = 0.0736 [Pb2+] + 0.0846 And R² = 0.9971. Three samples were analyzed in triplicate and the concentration of lead obtained ranged from 84.74 ± 3.70 mg kg-1; 69.93 ± 11.84 mg kg-1 and 76.45 ± 7.12 mg kg-1. For the standard addition curve, the concentration found was approximately 230.00 mg kg-1. Considering the Brazilian standard, the lead concentration should not exceed 2.00 mg kg-1, thus, it’s concluded that the values obtained were not within the norm for this metal.
id UFOP_6c30015a4b27a6bbe519f7dffdfcb6b5
oai_identifier_str oai:repositorio.ufop.br:123456789/9954
network_acronym_str UFOP
network_name_str Repositório Institucional da UFOP
repository_id_str 3233
spelling Optimization of a homogeneous ternary solvent system for the quantification of lead in crystal sugar samples.LeadQuantificationCristal sugarHomogeneous ternary systemDuring sugar production, contamination of the sugar by potentially toxic metals may occur. Therefore, it is necessary to develop methods to quantify these contaminants. Analytical method for monitoring of lead in sugar samples was developed with the use of homogeneous ternary system of solvents and UV-Vis spectrophotometry. Ternary system was optimized using multivariate experiments and the best condition was: 10% water, 80% ethanol and 10% methyl isobutyl ketone. As the complexing agent, monosodium 4-(2-pyridylazo) resorcinol used. Calibration curve was linear from 0.64 to 5.00 mg L-1, ABS = 0.0873 [Pb2 +] - 0.0032 and R² = 0.9988. The limit of quantification was 0.53 mg L-1 and limit of detection was 0.45 mg L-1 with 95% confidence level, the standard addition curve was linear, ABS = 0.0736 [Pb2+] + 0.0846 And R² = 0.9971. Three samples were analyzed in triplicate and the concentration of lead obtained ranged from 84.74 ± 3.70 mg kg-1; 69.93 ± 11.84 mg kg-1 and 76.45 ± 7.12 mg kg-1. For the standard addition curve, the concentration found was approximately 230.00 mg kg-1. Considering the Brazilian standard, the lead concentration should not exceed 2.00 mg kg-1, thus, it’s concluded that the values obtained were not within the norm for this metal.2018-05-18T17:31:16Z2018-05-18T17:31:16Z2017info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfCHAGAS, J. O. et al. Optimization of a homogeneous ternary solvent system for the quantification of lead in crystal sugar samples. Eclética Química Journal, v. 42, p. 65-70, 2017. Disponível em: <http://revista.iq.unesp.br/ojs/index.php/ecletica/article/view/37>. Acesso em: 05 abr. 2018.19839278http://www.repositorio.ufop.br/handle/123456789/9954Todo o conteúdo do periódico Eclética Química, exceto onde identificado, está licenciado sob uma licença Creative Commons 4.0 que permite copiar, distribuir e transmitir o trabalho em qualquer suporte ou formato desde que sejam citados o autor e o licenciante. Fonte: Eclética Química <http://www.scielo.br/scielo.php?script=sci_serial&pid=0100-4670&lng=en&nrm=iso>. Acesso em: 07 nov. 2016info:eu-repo/semantics/openAccessChagas, Júnior OlairCorrêa, SilvianaMelo, Isabela Cristina SilvaLobo, Fabiana AparecidaAlmeida, Alex Magalhães deengreponame:Repositório Institucional da UFOPinstname:Universidade Federal de Ouro Preto (UFOP)instacron:UFOP2018-05-18T17:31:16Zoai:repositorio.ufop.br:123456789/9954Repositório InstitucionalPUBhttp://www.repositorio.ufop.br/oai/requestrepositorio@ufop.edu.bropendoar:32332018-05-18T17:31:16Repositório Institucional da UFOP - Universidade Federal de Ouro Preto (UFOP)false
dc.title.none.fl_str_mv Optimization of a homogeneous ternary solvent system for the quantification of lead in crystal sugar samples.
title Optimization of a homogeneous ternary solvent system for the quantification of lead in crystal sugar samples.
spellingShingle Optimization of a homogeneous ternary solvent system for the quantification of lead in crystal sugar samples.
Chagas, Júnior Olair
Lead
Quantification
Cristal sugar
Homogeneous ternary system
title_short Optimization of a homogeneous ternary solvent system for the quantification of lead in crystal sugar samples.
title_full Optimization of a homogeneous ternary solvent system for the quantification of lead in crystal sugar samples.
title_fullStr Optimization of a homogeneous ternary solvent system for the quantification of lead in crystal sugar samples.
title_full_unstemmed Optimization of a homogeneous ternary solvent system for the quantification of lead in crystal sugar samples.
title_sort Optimization of a homogeneous ternary solvent system for the quantification of lead in crystal sugar samples.
author Chagas, Júnior Olair
author_facet Chagas, Júnior Olair
Corrêa, Silviana
Melo, Isabela Cristina Silva
Lobo, Fabiana Aparecida
Almeida, Alex Magalhães de
author_role author
author2 Corrêa, Silviana
Melo, Isabela Cristina Silva
Lobo, Fabiana Aparecida
Almeida, Alex Magalhães de
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Chagas, Júnior Olair
Corrêa, Silviana
Melo, Isabela Cristina Silva
Lobo, Fabiana Aparecida
Almeida, Alex Magalhães de
dc.subject.por.fl_str_mv Lead
Quantification
Cristal sugar
Homogeneous ternary system
topic Lead
Quantification
Cristal sugar
Homogeneous ternary system
description During sugar production, contamination of the sugar by potentially toxic metals may occur. Therefore, it is necessary to develop methods to quantify these contaminants. Analytical method for monitoring of lead in sugar samples was developed with the use of homogeneous ternary system of solvents and UV-Vis spectrophotometry. Ternary system was optimized using multivariate experiments and the best condition was: 10% water, 80% ethanol and 10% methyl isobutyl ketone. As the complexing agent, monosodium 4-(2-pyridylazo) resorcinol used. Calibration curve was linear from 0.64 to 5.00 mg L-1, ABS = 0.0873 [Pb2 +] - 0.0032 and R² = 0.9988. The limit of quantification was 0.53 mg L-1 and limit of detection was 0.45 mg L-1 with 95% confidence level, the standard addition curve was linear, ABS = 0.0736 [Pb2+] + 0.0846 And R² = 0.9971. Three samples were analyzed in triplicate and the concentration of lead obtained ranged from 84.74 ± 3.70 mg kg-1; 69.93 ± 11.84 mg kg-1 and 76.45 ± 7.12 mg kg-1. For the standard addition curve, the concentration found was approximately 230.00 mg kg-1. Considering the Brazilian standard, the lead concentration should not exceed 2.00 mg kg-1, thus, it’s concluded that the values obtained were not within the norm for this metal.
publishDate 2017
dc.date.none.fl_str_mv 2017
2018-05-18T17:31:16Z
2018-05-18T17:31:16Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv CHAGAS, J. O. et al. Optimization of a homogeneous ternary solvent system for the quantification of lead in crystal sugar samples. Eclética Química Journal, v. 42, p. 65-70, 2017. Disponível em: <http://revista.iq.unesp.br/ojs/index.php/ecletica/article/view/37>. Acesso em: 05 abr. 2018.
19839278
http://www.repositorio.ufop.br/handle/123456789/9954
identifier_str_mv CHAGAS, J. O. et al. Optimization of a homogeneous ternary solvent system for the quantification of lead in crystal sugar samples. Eclética Química Journal, v. 42, p. 65-70, 2017. Disponível em: <http://revista.iq.unesp.br/ojs/index.php/ecletica/article/view/37>. Acesso em: 05 abr. 2018.
19839278
url http://www.repositorio.ufop.br/handle/123456789/9954
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFOP
instname:Universidade Federal de Ouro Preto (UFOP)
instacron:UFOP
instname_str Universidade Federal de Ouro Preto (UFOP)
instacron_str UFOP
institution UFOP
reponame_str Repositório Institucional da UFOP
collection Repositório Institucional da UFOP
repository.name.fl_str_mv Repositório Institucional da UFOP - Universidade Federal de Ouro Preto (UFOP)
repository.mail.fl_str_mv repositorio@ufop.edu.br
_version_ 1813002848291520512