Cost assessment of efficiency losses in hydroelectric plants.
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UFOP |
Texto Completo: | http://www.repositorio.ufop.br/handle/123456789/4253 https://doi.org/10.1016/j.epsr.2011.05.006 |
Resumo: | Some important real-time tasks of the independent system operator (ISO) are the monitoring and control of power system events (load deviations and contingencies). These events are usually managed by the ISO using operating reserve ancillary services. These services represent an additional capacity (MW) available in generators and some interruptible loads. Generators must change their operating points in order that this capacity can remain available. These changes might lead to efficiency losses in energy production. In systems with a high percentage of hydroelectric production, hydroelectric plants need to know the impact of ancillary services on their profits. This work therefore analyzes the cost of efficiency losses due to operating reserve availability in hydroelectric generators. A method to calculate this cost component is proposed using a unit commitment dispatch for a single hydroelectric plant. This dispatch is performed without considering the operating reserve availability and is compared with the traditional dispatch, which takes into account the availability of operating reserve. The proposal is used to calculate the cost of efficiency losses on a Brazilian hydroelectric generator. We found that the cost of efficiency losses can be considerable when compared to the incomes of a hydroelectric plant in the short-term market. |
id |
UFOP_bab52a5cfd32d7a0db018519ce7ee440 |
---|---|
oai_identifier_str |
oai:repositorio.ufop.br:123456789/4253 |
network_acronym_str |
UFOP |
network_name_str |
Repositório Institucional da UFOP |
repository_id_str |
3233 |
spelling |
Cost assessment of efficiency losses in hydroelectric plants.Ancillary servicesEfficiency lossesHydroelectric generatorsOperating reserveSome important real-time tasks of the independent system operator (ISO) are the monitoring and control of power system events (load deviations and contingencies). These events are usually managed by the ISO using operating reserve ancillary services. These services represent an additional capacity (MW) available in generators and some interruptible loads. Generators must change their operating points in order that this capacity can remain available. These changes might lead to efficiency losses in energy production. In systems with a high percentage of hydroelectric production, hydroelectric plants need to know the impact of ancillary services on their profits. This work therefore analyzes the cost of efficiency losses due to operating reserve availability in hydroelectric generators. A method to calculate this cost component is proposed using a unit commitment dispatch for a single hydroelectric plant. This dispatch is performed without considering the operating reserve availability and is compared with the traditional dispatch, which takes into account the availability of operating reserve. The proposal is used to calculate the cost of efficiency losses on a Brazilian hydroelectric generator. We found that the cost of efficiency losses can be considerable when compared to the incomes of a hydroelectric plant in the short-term market.2015-01-16T15:58:38Z2015-01-16T15:58:38Z2011info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfMANSO, J. C. G.; FELTRIN, A. P.; YUSTA LOYO, J. M. Cost assessment of efficiency losses in hydroelectric plants. Electric Power Systems Research, v. 81, p. 1866-1873, 2011. Disponível em: <http://www.sciencedirect.com/science/article/pii/S0378779611001180>. Acesso em: 09 jan. 2015.0378-7796http://www.repositorio.ufop.br/handle/123456789/4253https://doi.org/10.1016/j.epsr.2011.05.006O periódico Electric Power Systems Research concede permissão para depósito do artigo no Repositório Institucional da UFOP. Número da licença: 3544811366967.info:eu-repo/semantics/openAccessManso, Juan Carlos GalvisFeltrin, Antonio PadilhaYusta Loyo, Jose Mariaengreponame:Repositório Institucional da UFOPinstname:Universidade Federal de Ouro Preto (UFOP)instacron:UFOP2024-11-10T23:09:54Zoai:repositorio.ufop.br:123456789/4253Repositório InstitucionalPUBhttp://www.repositorio.ufop.br/oai/requestrepositorio@ufop.edu.bropendoar:32332024-11-10T23:09:54Repositório Institucional da UFOP - Universidade Federal de Ouro Preto (UFOP)false |
dc.title.none.fl_str_mv |
Cost assessment of efficiency losses in hydroelectric plants. |
title |
Cost assessment of efficiency losses in hydroelectric plants. |
spellingShingle |
Cost assessment of efficiency losses in hydroelectric plants. Manso, Juan Carlos Galvis Ancillary services Efficiency losses Hydroelectric generators Operating reserve |
title_short |
Cost assessment of efficiency losses in hydroelectric plants. |
title_full |
Cost assessment of efficiency losses in hydroelectric plants. |
title_fullStr |
Cost assessment of efficiency losses in hydroelectric plants. |
title_full_unstemmed |
Cost assessment of efficiency losses in hydroelectric plants. |
title_sort |
Cost assessment of efficiency losses in hydroelectric plants. |
author |
Manso, Juan Carlos Galvis |
author_facet |
Manso, Juan Carlos Galvis Feltrin, Antonio Padilha Yusta Loyo, Jose Maria |
author_role |
author |
author2 |
Feltrin, Antonio Padilha Yusta Loyo, Jose Maria |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Manso, Juan Carlos Galvis Feltrin, Antonio Padilha Yusta Loyo, Jose Maria |
dc.subject.por.fl_str_mv |
Ancillary services Efficiency losses Hydroelectric generators Operating reserve |
topic |
Ancillary services Efficiency losses Hydroelectric generators Operating reserve |
description |
Some important real-time tasks of the independent system operator (ISO) are the monitoring and control of power system events (load deviations and contingencies). These events are usually managed by the ISO using operating reserve ancillary services. These services represent an additional capacity (MW) available in generators and some interruptible loads. Generators must change their operating points in order that this capacity can remain available. These changes might lead to efficiency losses in energy production. In systems with a high percentage of hydroelectric production, hydroelectric plants need to know the impact of ancillary services on their profits. This work therefore analyzes the cost of efficiency losses due to operating reserve availability in hydroelectric generators. A method to calculate this cost component is proposed using a unit commitment dispatch for a single hydroelectric plant. This dispatch is performed without considering the operating reserve availability and is compared with the traditional dispatch, which takes into account the availability of operating reserve. The proposal is used to calculate the cost of efficiency losses on a Brazilian hydroelectric generator. We found that the cost of efficiency losses can be considerable when compared to the incomes of a hydroelectric plant in the short-term market. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011 2015-01-16T15:58:38Z 2015-01-16T15:58:38Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
MANSO, J. C. G.; FELTRIN, A. P.; YUSTA LOYO, J. M. Cost assessment of efficiency losses in hydroelectric plants. Electric Power Systems Research, v. 81, p. 1866-1873, 2011. Disponível em: <http://www.sciencedirect.com/science/article/pii/S0378779611001180>. Acesso em: 09 jan. 2015. 0378-7796 http://www.repositorio.ufop.br/handle/123456789/4253 https://doi.org/10.1016/j.epsr.2011.05.006 |
identifier_str_mv |
MANSO, J. C. G.; FELTRIN, A. P.; YUSTA LOYO, J. M. Cost assessment of efficiency losses in hydroelectric plants. Electric Power Systems Research, v. 81, p. 1866-1873, 2011. Disponível em: <http://www.sciencedirect.com/science/article/pii/S0378779611001180>. Acesso em: 09 jan. 2015. 0378-7796 |
url |
http://www.repositorio.ufop.br/handle/123456789/4253 https://doi.org/10.1016/j.epsr.2011.05.006 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFOP instname:Universidade Federal de Ouro Preto (UFOP) instacron:UFOP |
instname_str |
Universidade Federal de Ouro Preto (UFOP) |
instacron_str |
UFOP |
institution |
UFOP |
reponame_str |
Repositório Institucional da UFOP |
collection |
Repositório Institucional da UFOP |
repository.name.fl_str_mv |
Repositório Institucional da UFOP - Universidade Federal de Ouro Preto (UFOP) |
repository.mail.fl_str_mv |
repositorio@ufop.edu.br |
_version_ |
1823329435310358528 |