Influence of cooling methods on the residual mechanical behavior of fire-exposed concrete : an experimental study.
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UFOP |
Texto Completo: | http://www.repositorio.ufop.br/jspui/handle/123456789/14516 https://doi.org/10.3390/ma12213512 |
Resumo: | This work reports the main conclusions of a study on the mechanical behavior of concrete under ISO 834 fire with different cooling methods. The aim of this research was to provide reliable data for the analysis of structures damaged by fire. The experimental program used cylindrical concrete test specimens subjected to ISO 834 heating in a furnace up to maximum gas temperatures of 400, 500, 600, 700, and 800 ◦C. The compressive strength was measured in three situations: (a) at the different temperature levels reached in the furnace; (b) after a natural cooling process; and (c) after aspersion with water at ambient temperature. The results indicate that the concrete residual compressive strength is fairly dependent on the maximum temperature reached in the furnace and revealed that concrete of a lower strength preserved relatively higher levels of strength. The cooling method significantly influenced the strength, albeit at a lower intensity. In all cases, the residual strength remained in the range of 38% to 67% of the strength at ambient temperature. The statistical analysis showed that the data obtained by the experimental program are significant and confirmed the influence of the conditions imposed on the residual strength. |
id |
UFOP_e24296fc501e294cbd1945063309c1ec |
---|---|
oai_identifier_str |
oai:repositorio.ufop.br:123456789/14516 |
network_acronym_str |
UFOP |
network_name_str |
Repositório Institucional da UFOP |
repository_id_str |
3233 |
spelling |
Influence of cooling methods on the residual mechanical behavior of fire-exposed concrete : an experimental study.Concrete fire degradationResidual mechanical behaviorThis work reports the main conclusions of a study on the mechanical behavior of concrete under ISO 834 fire with different cooling methods. The aim of this research was to provide reliable data for the analysis of structures damaged by fire. The experimental program used cylindrical concrete test specimens subjected to ISO 834 heating in a furnace up to maximum gas temperatures of 400, 500, 600, 700, and 800 ◦C. The compressive strength was measured in three situations: (a) at the different temperature levels reached in the furnace; (b) after a natural cooling process; and (c) after aspersion with water at ambient temperature. The results indicate that the concrete residual compressive strength is fairly dependent on the maximum temperature reached in the furnace and revealed that concrete of a lower strength preserved relatively higher levels of strength. The cooling method significantly influenced the strength, albeit at a lower intensity. In all cases, the residual strength remained in the range of 38% to 67% of the strength at ambient temperature. The statistical analysis showed that the data obtained by the experimental program are significant and confirmed the influence of the conditions imposed on the residual strength.2022-02-17T16:00:07Z2022-02-17T16:00:07Z2019info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfCARVALHO, E. F. T. de. et al. Influence of cooling methods on the residual mechanical behavior of fire-exposed concrete: an experimental study. Materials, v. 12, p. 3512, set./out. 2019. Disponível em: <https://www.mdpi.com/1996-1944/12/21/3512>. Acesso em: 12 set. 2021.1996-1944http://www.repositorio.ufop.br/jspui/handle/123456789/14516https://doi.org/10.3390/ma12213512This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Fonte: o PDF do artigo.info:eu-repo/semantics/openAccessCarvalho, Espedito Felipe Teixeira deSilva Neto, João Trajano daSoares Junior, Paulo Roberto RibeiroMaciel, Priscila de SouzaFransozo, Hélder LuísBezerra, Augusto Cesar da SilvaGouveia, Antônio Maria Claret deengreponame:Repositório Institucional da UFOPinstname:Universidade Federal de Ouro Preto (UFOP)instacron:UFOP2022-02-17T16:00:17Zoai:repositorio.ufop.br:123456789/14516Repositório InstitucionalPUBhttp://www.repositorio.ufop.br/oai/requestrepositorio@ufop.edu.bropendoar:32332022-02-17T16:00:17Repositório Institucional da UFOP - Universidade Federal de Ouro Preto (UFOP)false |
dc.title.none.fl_str_mv |
Influence of cooling methods on the residual mechanical behavior of fire-exposed concrete : an experimental study. |
title |
Influence of cooling methods on the residual mechanical behavior of fire-exposed concrete : an experimental study. |
spellingShingle |
Influence of cooling methods on the residual mechanical behavior of fire-exposed concrete : an experimental study. Carvalho, Espedito Felipe Teixeira de Concrete fire degradation Residual mechanical behavior |
title_short |
Influence of cooling methods on the residual mechanical behavior of fire-exposed concrete : an experimental study. |
title_full |
Influence of cooling methods on the residual mechanical behavior of fire-exposed concrete : an experimental study. |
title_fullStr |
Influence of cooling methods on the residual mechanical behavior of fire-exposed concrete : an experimental study. |
title_full_unstemmed |
Influence of cooling methods on the residual mechanical behavior of fire-exposed concrete : an experimental study. |
title_sort |
Influence of cooling methods on the residual mechanical behavior of fire-exposed concrete : an experimental study. |
author |
Carvalho, Espedito Felipe Teixeira de |
author_facet |
Carvalho, Espedito Felipe Teixeira de Silva Neto, João Trajano da Soares Junior, Paulo Roberto Ribeiro Maciel, Priscila de Souza Fransozo, Hélder Luís Bezerra, Augusto Cesar da Silva Gouveia, Antônio Maria Claret de |
author_role |
author |
author2 |
Silva Neto, João Trajano da Soares Junior, Paulo Roberto Ribeiro Maciel, Priscila de Souza Fransozo, Hélder Luís Bezerra, Augusto Cesar da Silva Gouveia, Antônio Maria Claret de |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Carvalho, Espedito Felipe Teixeira de Silva Neto, João Trajano da Soares Junior, Paulo Roberto Ribeiro Maciel, Priscila de Souza Fransozo, Hélder Luís Bezerra, Augusto Cesar da Silva Gouveia, Antônio Maria Claret de |
dc.subject.por.fl_str_mv |
Concrete fire degradation Residual mechanical behavior |
topic |
Concrete fire degradation Residual mechanical behavior |
description |
This work reports the main conclusions of a study on the mechanical behavior of concrete under ISO 834 fire with different cooling methods. The aim of this research was to provide reliable data for the analysis of structures damaged by fire. The experimental program used cylindrical concrete test specimens subjected to ISO 834 heating in a furnace up to maximum gas temperatures of 400, 500, 600, 700, and 800 ◦C. The compressive strength was measured in three situations: (a) at the different temperature levels reached in the furnace; (b) after a natural cooling process; and (c) after aspersion with water at ambient temperature. The results indicate that the concrete residual compressive strength is fairly dependent on the maximum temperature reached in the furnace and revealed that concrete of a lower strength preserved relatively higher levels of strength. The cooling method significantly influenced the strength, albeit at a lower intensity. In all cases, the residual strength remained in the range of 38% to 67% of the strength at ambient temperature. The statistical analysis showed that the data obtained by the experimental program are significant and confirmed the influence of the conditions imposed on the residual strength. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019 2022-02-17T16:00:07Z 2022-02-17T16:00:07Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
CARVALHO, E. F. T. de. et al. Influence of cooling methods on the residual mechanical behavior of fire-exposed concrete: an experimental study. Materials, v. 12, p. 3512, set./out. 2019. Disponível em: <https://www.mdpi.com/1996-1944/12/21/3512>. Acesso em: 12 set. 2021. 1996-1944 http://www.repositorio.ufop.br/jspui/handle/123456789/14516 https://doi.org/10.3390/ma12213512 |
identifier_str_mv |
CARVALHO, E. F. T. de. et al. Influence of cooling methods on the residual mechanical behavior of fire-exposed concrete: an experimental study. Materials, v. 12, p. 3512, set./out. 2019. Disponível em: <https://www.mdpi.com/1996-1944/12/21/3512>. Acesso em: 12 set. 2021. 1996-1944 |
url |
http://www.repositorio.ufop.br/jspui/handle/123456789/14516 https://doi.org/10.3390/ma12213512 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFOP instname:Universidade Federal de Ouro Preto (UFOP) instacron:UFOP |
instname_str |
Universidade Federal de Ouro Preto (UFOP) |
instacron_str |
UFOP |
institution |
UFOP |
reponame_str |
Repositório Institucional da UFOP |
collection |
Repositório Institucional da UFOP |
repository.name.fl_str_mv |
Repositório Institucional da UFOP - Universidade Federal de Ouro Preto (UFOP) |
repository.mail.fl_str_mv |
repositorio@ufop.edu.br |
_version_ |
1813002837122088960 |