Desenvolvimento de sistemas adesivos empregando monômeros surfactantes como alternativa ao hidróxietil metacrilato (HEMA)

Detalhes bibliográficos
Autor(a) principal: Zanchi, Cesar Henrique
Data de Publicação: 2010
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFPel - Guaiaca
Texto Completo: http://repositorio.ufpel.edu.br/handle/ri/2255
Resumo: This study evaluated the influence of surfactant dimethacrylates (SD) on the resin-to-dentin immediate and long term microtensile bond strength (μTBS) and characterized the interfacial micromorphology of hybrid layer of the experimental HEMA-free self-etching systems. Five experimental HEMA-free two step self-etching systems containing different surfactant dimetacrylates (SD) (Bis-EMA 10, Bis-EMA 30, PEG 400, PEG 1000 and PEG 400 UDMA) and a HEMA-containing systems (control) were formulated. Sixty bovine incisors were allocated into six groups according each experimental adhesive system used. The teeth had the superficial coronal dentins exposed and were restored and sectioned to obtain sticks randomly allocated into 3 storage periods: 24h, 6 and 12 months. Thereafter the specimens were subjected to the μTBS test. Immediate μTBS data were analyzed by One-way ANOVA and Tukey s test. Long term μTBS data were analyzed by Kruskall-Wallis and Dunn test (α = 0.05). Analysis of the adhesive-dentin interfaces were performed through scanning electron microscopy. Between the HEMA-free groups, the adhesive system formulated with PEG 400 UDMA produced the highest μTBS and was similar to HEMA-containing group. Specimens of the 24 hours of storage were statistically higher for all groups tested when compared those after 6 and 12 months storage. None difference was found between 6 months and 12 months storage for each group. All the adhesives systems presented similar partially demineralized hybrid layer (1.5-3.0 μm thickness) with well formed resin tags. All SD present reasonable μTBS, being the PEG 400 UDMA a promising monomer to be considered as HEMA substitute in adhesive systems compositions.
id UFPL_187608eb98bd846a79b0b6bd0f7451e0
oai_identifier_str oai:guaiaca.ufpel.edu.br:123456789/2255
network_acronym_str UFPL
network_name_str Repositório Institucional da UFPel - Guaiaca
repository_id_str
spelling http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4268826P3http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4701753T0Demarco, Flávio Fernandohttp://lattes.cnpq.br/5439768560638141Piva, EvandroZanchi, Cesar Henrique2014-08-20T14:30:11Z2013-12-162014-08-20T14:30:11Z2010-05-07ZANCHI, Cesar Henrique. Development of adhesive systems employing surfactant monomers as substitute to hydroxyethyl methacrylate (HEMA). 2010. 110 f. Tese (Doutorado em Odontologia) - Universidade Federal de Pelotas, Pelotas, 2010.http://repositorio.ufpel.edu.br/handle/ri/2255This study evaluated the influence of surfactant dimethacrylates (SD) on the resin-to-dentin immediate and long term microtensile bond strength (μTBS) and characterized the interfacial micromorphology of hybrid layer of the experimental HEMA-free self-etching systems. Five experimental HEMA-free two step self-etching systems containing different surfactant dimetacrylates (SD) (Bis-EMA 10, Bis-EMA 30, PEG 400, PEG 1000 and PEG 400 UDMA) and a HEMA-containing systems (control) were formulated. Sixty bovine incisors were allocated into six groups according each experimental adhesive system used. The teeth had the superficial coronal dentins exposed and were restored and sectioned to obtain sticks randomly allocated into 3 storage periods: 24h, 6 and 12 months. Thereafter the specimens were subjected to the μTBS test. Immediate μTBS data were analyzed by One-way ANOVA and Tukey s test. Long term μTBS data were analyzed by Kruskall-Wallis and Dunn test (α = 0.05). Analysis of the adhesive-dentin interfaces were performed through scanning electron microscopy. Between the HEMA-free groups, the adhesive system formulated with PEG 400 UDMA produced the highest μTBS and was similar to HEMA-containing group. Specimens of the 24 hours of storage were statistically higher for all groups tested when compared those after 6 and 12 months storage. None difference was found between 6 months and 12 months storage for each group. All the adhesives systems presented similar partially demineralized hybrid layer (1.5-3.0 μm thickness) with well formed resin tags. All SD present reasonable μTBS, being the PEG 400 UDMA a promising monomer to be considered as HEMA substitute in adhesive systems compositions.Este estudo avaliou a influência de dimetacrilatos surfactantes (DS) na resistência de união à dentina por microtração (RU), imediata e após armazenagem, além de caracterizar a micromorfologia da camada híbrida de sistemas adesivos experimentais autocondicionantes livres de HEMA. Foram formulados cinco sistemas adesivos autocondicionantes de dois passos livres de HEMA contendo diferentes DS (Bis-EMA 10, Bis-EMA 30, PEG 400, PEG 1000 and PEG 400 UDMA) e um sistema contendo HEMA, empregado como controle. Foi realizada a exposição da dentina superficial de sessenta incisivos bovinos posteriormente alocados em seis grupos experimentais de acordo com o sistema adesivo empregado. Os dentes foram restaurados e seccionados para obter espécimes (palitos) posteriormente divididos em três períodos de armazenagem: 24h, 6 e 12 meses. Após, os espécimes foram sujeitos ao teste de RU. Resultados de RU imediata foram analisados por ANOVA 1-fator e teste complementar de Tukey. Resultados de RU após envelhecimento foram analisados por Kruskall-Wallis e teste de Dunn (α = 0.05). Analises das interfaces de união dente-restauração foram realizadas através de microscopia eletrônica de varredura. Entre os grupos livres de HEMA, o sistema adesivo formulado com PEG 400 UDMA produziu maior RU e foi estatisticamente similar ao grupo controle contendo HEMA. Os espécimes testados após 24 horas de armazenamento apresentaram RU estatisticamente maior para todos os grupos quando comparados os espécimes testados após 6 e 12 meses de armazenagem. Não foram observadas diferenças significativas entre os grupos testados após 6 e 12 meses. Todos os sistemas adesivos apresentaram camada hibrida parcialmente desmineralizada (1.5-3 μm de espessura) com formação de prolongamentos resinosos. Em geral os sistemas adesivos demonstraram valores de RU satisfatórios, sendo o PEG 400 UDMA um monômero promissor para o desenvolvimento de sistemas adesivos livres de HEMA.application/pdfporUniversidade Federal de PelotasPrograma de Pós-Graduação em OdontologiaUFPelBROdontologiaAdesivos dentáriosSurfactanteResistência de união por microtraçãoInterface resina-dentinaBiodegradaçãoDental adhesiveSurfactantMicrotensile bond strength testResin-dentin interfaceBiodegradationCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIADesenvolvimento de sistemas adesivos empregando monômeros surfactantes como alternativa ao hidróxietil metacrilato (HEMA)Development of adhesive systems employing surfactant monomers as substitute to hydroxyethyl methacrylate (HEMA)info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFPel - Guaiacainstname:Universidade Federal de Pelotas (UFPEL)instacron:UFPELORIGINALTese_Cesar_Henrique_Zanchi.pdfapplication/pdf1068579http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2255/1/Tese_Cesar_Henrique_Zanchi.pdf8e2ef86f128f91b16a71c1a2e41952f6MD51open accessTEXTTese_Cesar_Henrique_Zanchi.pdf.txtTese_Cesar_Henrique_Zanchi.pdf.txtExtracted Texttext/plain159308http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2255/2/Tese_Cesar_Henrique_Zanchi.pdf.txt14a1f4765a4bd336f505080f5b027616MD52open accessTHUMBNAILTese_Cesar_Henrique_Zanchi.pdf.jpgTese_Cesar_Henrique_Zanchi.pdf.jpgGenerated Thumbnailimage/jpeg1853http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2255/3/Tese_Cesar_Henrique_Zanchi.pdf.jpg6d6be5104ca60a2ed138db7af04b2d13MD53open access123456789/22552018-07-13 09:42:03.834open accessoai:guaiaca.ufpel.edu.br:123456789/2255Repositório InstitucionalPUBhttp://repositorio.ufpel.edu.br/oai/requestrippel@ufpel.edu.br || repositorio@ufpel.edu.br || aline.batista@ufpel.edu.bropendoar:2018-07-13T12:42:03Repositório Institucional da UFPel - Guaiaca - Universidade Federal de Pelotas (UFPEL)false
dc.title.por.fl_str_mv Desenvolvimento de sistemas adesivos empregando monômeros surfactantes como alternativa ao hidróxietil metacrilato (HEMA)
dc.title.alternative.eng.fl_str_mv Development of adhesive systems employing surfactant monomers as substitute to hydroxyethyl methacrylate (HEMA)
title Desenvolvimento de sistemas adesivos empregando monômeros surfactantes como alternativa ao hidróxietil metacrilato (HEMA)
spellingShingle Desenvolvimento de sistemas adesivos empregando monômeros surfactantes como alternativa ao hidróxietil metacrilato (HEMA)
Zanchi, Cesar Henrique
Adesivos dentários
Surfactante
Resistência de união por microtração
Interface resina-dentina
Biodegradação
Dental adhesive
Surfactant
Microtensile bond strength test
Resin-dentin interface
Biodegradation
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
title_short Desenvolvimento de sistemas adesivos empregando monômeros surfactantes como alternativa ao hidróxietil metacrilato (HEMA)
title_full Desenvolvimento de sistemas adesivos empregando monômeros surfactantes como alternativa ao hidróxietil metacrilato (HEMA)
title_fullStr Desenvolvimento de sistemas adesivos empregando monômeros surfactantes como alternativa ao hidróxietil metacrilato (HEMA)
title_full_unstemmed Desenvolvimento de sistemas adesivos empregando monômeros surfactantes como alternativa ao hidróxietil metacrilato (HEMA)
title_sort Desenvolvimento de sistemas adesivos empregando monômeros surfactantes como alternativa ao hidróxietil metacrilato (HEMA)
author Zanchi, Cesar Henrique
author_facet Zanchi, Cesar Henrique
author_role author
dc.contributor.authorLattes.por.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4268826P3
dc.contributor.advisorLattes.por.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4701753T0
dc.contributor.advisor-co1.fl_str_mv Demarco, Flávio Fernando
dc.contributor.advisor-co1Lattes.fl_str_mv http://lattes.cnpq.br/5439768560638141
dc.contributor.advisor1.fl_str_mv Piva, Evandro
dc.contributor.author.fl_str_mv Zanchi, Cesar Henrique
contributor_str_mv Demarco, Flávio Fernando
Piva, Evandro
dc.subject.por.fl_str_mv Adesivos dentários
Surfactante
Resistência de união por microtração
Interface resina-dentina
Biodegradação
topic Adesivos dentários
Surfactante
Resistência de união por microtração
Interface resina-dentina
Biodegradação
Dental adhesive
Surfactant
Microtensile bond strength test
Resin-dentin interface
Biodegradation
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
dc.subject.eng.fl_str_mv Dental adhesive
Surfactant
Microtensile bond strength test
Resin-dentin interface
Biodegradation
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
description This study evaluated the influence of surfactant dimethacrylates (SD) on the resin-to-dentin immediate and long term microtensile bond strength (μTBS) and characterized the interfacial micromorphology of hybrid layer of the experimental HEMA-free self-etching systems. Five experimental HEMA-free two step self-etching systems containing different surfactant dimetacrylates (SD) (Bis-EMA 10, Bis-EMA 30, PEG 400, PEG 1000 and PEG 400 UDMA) and a HEMA-containing systems (control) were formulated. Sixty bovine incisors were allocated into six groups according each experimental adhesive system used. The teeth had the superficial coronal dentins exposed and were restored and sectioned to obtain sticks randomly allocated into 3 storage periods: 24h, 6 and 12 months. Thereafter the specimens were subjected to the μTBS test. Immediate μTBS data were analyzed by One-way ANOVA and Tukey s test. Long term μTBS data were analyzed by Kruskall-Wallis and Dunn test (α = 0.05). Analysis of the adhesive-dentin interfaces were performed through scanning electron microscopy. Between the HEMA-free groups, the adhesive system formulated with PEG 400 UDMA produced the highest μTBS and was similar to HEMA-containing group. Specimens of the 24 hours of storage were statistically higher for all groups tested when compared those after 6 and 12 months storage. None difference was found between 6 months and 12 months storage for each group. All the adhesives systems presented similar partially demineralized hybrid layer (1.5-3.0 μm thickness) with well formed resin tags. All SD present reasonable μTBS, being the PEG 400 UDMA a promising monomer to be considered as HEMA substitute in adhesive systems compositions.
publishDate 2010
dc.date.issued.fl_str_mv 2010-05-07
dc.date.available.fl_str_mv 2013-12-16
2014-08-20T14:30:11Z
dc.date.accessioned.fl_str_mv 2014-08-20T14:30:11Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv ZANCHI, Cesar Henrique. Development of adhesive systems employing surfactant monomers as substitute to hydroxyethyl methacrylate (HEMA). 2010. 110 f. Tese (Doutorado em Odontologia) - Universidade Federal de Pelotas, Pelotas, 2010.
dc.identifier.uri.fl_str_mv http://repositorio.ufpel.edu.br/handle/ri/2255
identifier_str_mv ZANCHI, Cesar Henrique. Development of adhesive systems employing surfactant monomers as substitute to hydroxyethyl methacrylate (HEMA). 2010. 110 f. Tese (Doutorado em Odontologia) - Universidade Federal de Pelotas, Pelotas, 2010.
url http://repositorio.ufpel.edu.br/handle/ri/2255
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Pelotas
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Odontologia
dc.publisher.initials.fl_str_mv UFPel
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Odontologia
publisher.none.fl_str_mv Universidade Federal de Pelotas
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFPel - Guaiaca
instname:Universidade Federal de Pelotas (UFPEL)
instacron:UFPEL
instname_str Universidade Federal de Pelotas (UFPEL)
instacron_str UFPEL
institution UFPEL
reponame_str Repositório Institucional da UFPel - Guaiaca
collection Repositório Institucional da UFPel - Guaiaca
bitstream.url.fl_str_mv http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2255/1/Tese_Cesar_Henrique_Zanchi.pdf
http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2255/2/Tese_Cesar_Henrique_Zanchi.pdf.txt
http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2255/3/Tese_Cesar_Henrique_Zanchi.pdf.jpg
bitstream.checksum.fl_str_mv 8e2ef86f128f91b16a71c1a2e41952f6
14a1f4765a4bd336f505080f5b027616
6d6be5104ca60a2ed138db7af04b2d13
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFPel - Guaiaca - Universidade Federal de Pelotas (UFPEL)
repository.mail.fl_str_mv rippel@ufpel.edu.br || repositorio@ufpel.edu.br || aline.batista@ufpel.edu.br
_version_ 1813710170439548928