Influência da espessura da camada de opaco na capacidade de mascaramento de metalocerâmicas
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFPel - Guaiaca |
Texto Completo: | http://repositorio.ufpel.edu.br/handle/ri/2275 |
Resumo: | The aim of this study was to evaluate the ability of two ceramic opaque masking applied in different thicknesses in a metallic substrate. 80 Ni-Cr (High Bond) metalic discs were fabricated, each with 1.6 mm diameter and 1 mm thickness, by lost wax technique. After disks obtaining, they were divided into 8 groups (n = 10) and opaque ceramic (Noritake) "paste" (groups 1 to 4) and "powder" (groups 5 to 8) was applied with a camel hair brush and distilled water. The opaque layers were machined with aluminum oxide burs to achieve the following thickness: G1 = G5 and 0.10 mm thick; G2 and G6 = 0.15 mm; G3 and G7 = 0.20 mm and G4 and G8 = 0.30 mm thick. Than opaque dentin ceramic was applied (two sintering cicles, totaling 0.7 mm) and glazed. The color was evaluated with the aid of a portable spectrocolorimeter (Konica - Minolta CR-10), which registered the color of specimens in the CIE L*a*b* scale. The absolute values of L *, a * and b * were statistically analyzed as isolated variables.The ΔE were also analyzed, considering the mean values of L * a * b * in the control group (G4) as reference values. Once data showed normality and homogeneity, it were applied 2-way ANOVA and Tukey s complementary test, when needed, with p < 5%. Results: Powder opaque presented statistically significant greater values in (L*) and (ΔE) and the reverse happened to other two variables. Analysing opaque thickness, values may be grouped as followed: (L*) variable: (0,10mm = 0,15mm) < (0,20mm = 0,30mm); (a*) variable: (0,10mm) < (0,15mm = 0,20mm) < (0,30mm); (b*) variable showed no statistically significant differences; (ΔE) variable: (0,10mm) < (0,15mm = 0,20mm = 0,30mms). It could be concluded that paste and powder opaque have different behavior and all thickness, except 0,10 mm, may be used without significant color change |
id |
UFPL_5dca9c87f868a5683ac4ea292f92740b |
---|---|
oai_identifier_str |
oai:guaiaca.ufpel.edu.br:123456789/2275 |
network_acronym_str |
UFPL |
network_name_str |
Repositório Institucional da UFPel - Guaiaca |
repository_id_str |
|
spelling |
2014-08-20T14:30:14Z2014-01-242014-08-20T14:30:14Z2012-12-19PIEPER, Cari Maristela. Capacity opaque masking layer in thicknesses of metal laminated ceramics application. 2012. 58 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Pelotas, Pelotas, 2012.http://repositorio.ufpel.edu.br/handle/ri/2275The aim of this study was to evaluate the ability of two ceramic opaque masking applied in different thicknesses in a metallic substrate. 80 Ni-Cr (High Bond) metalic discs were fabricated, each with 1.6 mm diameter and 1 mm thickness, by lost wax technique. After disks obtaining, they were divided into 8 groups (n = 10) and opaque ceramic (Noritake) "paste" (groups 1 to 4) and "powder" (groups 5 to 8) was applied with a camel hair brush and distilled water. The opaque layers were machined with aluminum oxide burs to achieve the following thickness: G1 = G5 and 0.10 mm thick; G2 and G6 = 0.15 mm; G3 and G7 = 0.20 mm and G4 and G8 = 0.30 mm thick. Than opaque dentin ceramic was applied (two sintering cicles, totaling 0.7 mm) and glazed. The color was evaluated with the aid of a portable spectrocolorimeter (Konica - Minolta CR-10), which registered the color of specimens in the CIE L*a*b* scale. The absolute values of L *, a * and b * were statistically analyzed as isolated variables.The ΔE were also analyzed, considering the mean values of L * a * b * in the control group (G4) as reference values. Once data showed normality and homogeneity, it were applied 2-way ANOVA and Tukey s complementary test, when needed, with p < 5%. Results: Powder opaque presented statistically significant greater values in (L*) and (ΔE) and the reverse happened to other two variables. Analysing opaque thickness, values may be grouped as followed: (L*) variable: (0,10mm = 0,15mm) < (0,20mm = 0,30mm); (a*) variable: (0,10mm) < (0,15mm = 0,20mm) < (0,30mm); (b*) variable showed no statistically significant differences; (ΔE) variable: (0,10mm) < (0,15mm = 0,20mm = 0,30mms). It could be concluded that paste and powder opaque have different behavior and all thickness, except 0,10 mm, may be used without significant color changeO objetivo deste estudo foi avaliar a capacidade de mascaramento de duas cerâmicas opacas aplicadas em espessuras diferentes num substrato metálico. Para isso foram confeccionados 80 discos metálicos de Ni-Cr (High Bond) com 16 mm de diâmetro e 1mm de espessura, através da técnica da cera perdida. Após a obtenção dos discos estes foram divididos em 8 grupos (n=10) e foi aplicada a cerâmica opaca (Noritake) em pasta (grupos de 1 à 4) e em pó (grupos de 5 à 8) com pincel de pêlo de camelo e água destilada. As camadas opacas foram usinadas com pontas de óxido de alumínio até atingirem as seguintes espessuras: G1 e G5 = 0,10mm de espessura; G2 e G6 = 0,15mm; G3 e G7 = 0,20mm e G4 e G8 = 0,30mm de espessura. Após, foi aplicada cerâmica de dentina opaca (em dois ciclos de sinterização totalizando 0,7mm), e em seguida à sinterização foi realizado o glaze final.A avaliação da cor foi realizada com o auxílio do Espectrocolorímetro portátil (Konica - Minolta CR-10), que registrou a cor dos 80 corpos de prova metalocerâmicos nos eixos da escala CIE - L*, a* b* após o ciclo de glaze. Os valores absolutos de L*, a* e b* dos grupos foram analisados estatísticamente como variáveis isoladas. Também foi analisado o valor da variável ΔE, sendo que os valores médios de L* a* e b* do grupo controle (G4) foram considerados como os valores de referência para os cálculos do Δa, Δb, ΔL e ΔE dos demais grupos. Após constatada normalidade e homogeneidade dos dados foi aplicada análise de variância para dois fatores de variação (2-way ANOVA) e teste complementar de Tukey ambos para p<5%. Resultados: O opaco em pó apresentou valores maiores estaticamente significantes nas variáveis (L*) e (ΔE), ocorrendo o inverso nas outras duas variáveis.Quanto à espessura de opaco, os valores podem ser agrupados da seguinte forma, segundo os testes complementares aplicados: variável (L*): (0,10mm = 0,15mm) < (0,20mm = 0,30mm); variável (a*): (0,10mm) < (0,15mm = 0,20mm) < (0,30mm); variável (b*): não houveram diferenças estatisticamente significantes; variável (ΔE): (0,10mm) < (0,15mm = 0,20mm = 0,30mm). Conclui-se que houve diferença entre os tipos de opaco em pasta e em pó e que todas as espessuras testadas, exceto a de 0,10 mm, podem ser usadas sem alteração significativa da corapplication/pdfporUniversidade Federal de PelotasPrograma de Pós-Graduação em OdontologiaUFPelBROdontologiaLigas metalo-cerâmicasCerâmica opacaOpacidadeMetal-ceramic alloysCeramic opaqueOpacityCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIAInfluência da espessura da camada de opaco na capacidade de mascaramento de metalocerâmicasCapacity opaque masking layer in thicknesses of metal laminated ceramics applicationinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://lattes.cnpq.br/3907489657746199Waldemarin, Renato Fabrício de Andradehttp://lattes.cnpq.br/6542284107758719Camacho, Guilherme BriãoPieper, Cari Maristelainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFPel - Guaiacainstname:Universidade Federal de Pelotas (UFPEL)instacron:UFPELORIGINALDissertacao_Cari_Maristela_Pieper.pdfapplication/pdf422459http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2275/1/Dissertacao_Cari_Maristela_Pieper.pdf06736de352d724ef840d5461683237cdMD51open accessTEXTDissertacao_Cari_Maristela_Pieper.pdf.txtDissertacao_Cari_Maristela_Pieper.pdf.txtExtracted Texttext/plain83343http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2275/2/Dissertacao_Cari_Maristela_Pieper.pdf.txt814da1ea26691ca0aa498359603bf004MD52open accessTHUMBNAILDissertacao_Cari_Maristela_Pieper.pdf.jpgDissertacao_Cari_Maristela_Pieper.pdf.jpgGenerated Thumbnailimage/jpeg1911http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2275/3/Dissertacao_Cari_Maristela_Pieper.pdf.jpg81595dc7ece7b79c1a55f0f96dfc87b3MD53open access123456789/22752019-09-19 08:50:16.663open accessoai:guaiaca.ufpel.edu.br:123456789/2275Repositório InstitucionalPUBhttp://repositorio.ufpel.edu.br/oai/requestrippel@ufpel.edu.br || repositorio@ufpel.edu.br || aline.batista@ufpel.edu.bropendoar:2019-09-19T11:50:16Repositório Institucional da UFPel - Guaiaca - Universidade Federal de Pelotas (UFPEL)false |
dc.title.por.fl_str_mv |
Influência da espessura da camada de opaco na capacidade de mascaramento de metalocerâmicas |
dc.title.alternative.eng.fl_str_mv |
Capacity opaque masking layer in thicknesses of metal laminated ceramics application |
title |
Influência da espessura da camada de opaco na capacidade de mascaramento de metalocerâmicas |
spellingShingle |
Influência da espessura da camada de opaco na capacidade de mascaramento de metalocerâmicas Pieper, Cari Maristela Ligas metalo-cerâmicas Cerâmica opaca Opacidade Metal-ceramic alloys Ceramic opaque Opacity CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
title_short |
Influência da espessura da camada de opaco na capacidade de mascaramento de metalocerâmicas |
title_full |
Influência da espessura da camada de opaco na capacidade de mascaramento de metalocerâmicas |
title_fullStr |
Influência da espessura da camada de opaco na capacidade de mascaramento de metalocerâmicas |
title_full_unstemmed |
Influência da espessura da camada de opaco na capacidade de mascaramento de metalocerâmicas |
title_sort |
Influência da espessura da camada de opaco na capacidade de mascaramento de metalocerâmicas |
author |
Pieper, Cari Maristela |
author_facet |
Pieper, Cari Maristela |
author_role |
author |
dc.contributor.authorLattes.por.fl_str_mv |
http://lattes.cnpq.br/3907489657746199 |
dc.contributor.advisor-co1.fl_str_mv |
Waldemarin, Renato Fabrício de Andrade |
dc.contributor.advisor-co1Lattes.fl_str_mv |
http://lattes.cnpq.br/6542284107758719 |
dc.contributor.advisor1.fl_str_mv |
Camacho, Guilherme Brião |
dc.contributor.author.fl_str_mv |
Pieper, Cari Maristela |
contributor_str_mv |
Waldemarin, Renato Fabrício de Andrade Camacho, Guilherme Brião |
dc.subject.por.fl_str_mv |
Ligas metalo-cerâmicas Cerâmica opaca Opacidade |
topic |
Ligas metalo-cerâmicas Cerâmica opaca Opacidade Metal-ceramic alloys Ceramic opaque Opacity CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
dc.subject.eng.fl_str_mv |
Metal-ceramic alloys Ceramic opaque Opacity |
dc.subject.cnpq.fl_str_mv |
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
description |
The aim of this study was to evaluate the ability of two ceramic opaque masking applied in different thicknesses in a metallic substrate. 80 Ni-Cr (High Bond) metalic discs were fabricated, each with 1.6 mm diameter and 1 mm thickness, by lost wax technique. After disks obtaining, they were divided into 8 groups (n = 10) and opaque ceramic (Noritake) "paste" (groups 1 to 4) and "powder" (groups 5 to 8) was applied with a camel hair brush and distilled water. The opaque layers were machined with aluminum oxide burs to achieve the following thickness: G1 = G5 and 0.10 mm thick; G2 and G6 = 0.15 mm; G3 and G7 = 0.20 mm and G4 and G8 = 0.30 mm thick. Than opaque dentin ceramic was applied (two sintering cicles, totaling 0.7 mm) and glazed. The color was evaluated with the aid of a portable spectrocolorimeter (Konica - Minolta CR-10), which registered the color of specimens in the CIE L*a*b* scale. The absolute values of L *, a * and b * were statistically analyzed as isolated variables.The ΔE were also analyzed, considering the mean values of L * a * b * in the control group (G4) as reference values. Once data showed normality and homogeneity, it were applied 2-way ANOVA and Tukey s complementary test, when needed, with p < 5%. Results: Powder opaque presented statistically significant greater values in (L*) and (ΔE) and the reverse happened to other two variables. Analysing opaque thickness, values may be grouped as followed: (L*) variable: (0,10mm = 0,15mm) < (0,20mm = 0,30mm); (a*) variable: (0,10mm) < (0,15mm = 0,20mm) < (0,30mm); (b*) variable showed no statistically significant differences; (ΔE) variable: (0,10mm) < (0,15mm = 0,20mm = 0,30mms). It could be concluded that paste and powder opaque have different behavior and all thickness, except 0,10 mm, may be used without significant color change |
publishDate |
2012 |
dc.date.issued.fl_str_mv |
2012-12-19 |
dc.date.accessioned.fl_str_mv |
2014-08-20T14:30:14Z |
dc.date.available.fl_str_mv |
2014-01-24 2014-08-20T14:30:14Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
PIEPER, Cari Maristela. Capacity opaque masking layer in thicknesses of metal laminated ceramics application. 2012. 58 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Pelotas, Pelotas, 2012. |
dc.identifier.uri.fl_str_mv |
http://repositorio.ufpel.edu.br/handle/ri/2275 |
identifier_str_mv |
PIEPER, Cari Maristela. Capacity opaque masking layer in thicknesses of metal laminated ceramics application. 2012. 58 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Pelotas, Pelotas, 2012. |
url |
http://repositorio.ufpel.edu.br/handle/ri/2275 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Pelotas |
dc.publisher.program.fl_str_mv |
Programa de Pós-Graduação em Odontologia |
dc.publisher.initials.fl_str_mv |
UFPel |
dc.publisher.country.fl_str_mv |
BR |
dc.publisher.department.fl_str_mv |
Odontologia |
publisher.none.fl_str_mv |
Universidade Federal de Pelotas |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFPel - Guaiaca instname:Universidade Federal de Pelotas (UFPEL) instacron:UFPEL |
instname_str |
Universidade Federal de Pelotas (UFPEL) |
instacron_str |
UFPEL |
institution |
UFPEL |
reponame_str |
Repositório Institucional da UFPel - Guaiaca |
collection |
Repositório Institucional da UFPel - Guaiaca |
bitstream.url.fl_str_mv |
http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2275/1/Dissertacao_Cari_Maristela_Pieper.pdf http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2275/2/Dissertacao_Cari_Maristela_Pieper.pdf.txt http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2275/3/Dissertacao_Cari_Maristela_Pieper.pdf.jpg |
bitstream.checksum.fl_str_mv |
06736de352d724ef840d5461683237cd 814da1ea26691ca0aa498359603bf004 81595dc7ece7b79c1a55f0f96dfc87b3 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFPel - Guaiaca - Universidade Federal de Pelotas (UFPEL) |
repository.mail.fl_str_mv |
rippel@ufpel.edu.br || repositorio@ufpel.edu.br || aline.batista@ufpel.edu.br |
_version_ |
1813710136126996480 |