Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFPel - Guaiaca |
Texto Completo: | http://repositorio.ufpel.edu.br/handle/ri/2291 |
Resumo: | This study evaluated the effects of immediate and delayed polishing on surface roughness (Ra), microhardness (KHN) and microleakage of a microfilled composite (Filtek A110) and a hybrid composite (Filtek Z250) restorations after one-year storage. Standardized cavities preparations were made in the buccal surface of 256 bovine teeth; half were restored with each composite. Immediately after photo activation finishing was carried out with #280 grit sandpaper. For each composite, the specimens were randomly allocated for two sub-groups. The first group (IM) was immediately polished, using three different systems (n=16): A- Sof-Lex; B- Flexicups; and C- a sequential technique using Flexicups, Jiffy Polishing Brush and Flexibuffs. The specimens were stored in saline solution at 37ºC. The second group (DE) was stored for two weeks and then polished with the same systems. Part of the specimens had their surface properties analyzed at the baseline, and the remaining specimens were stored for one-year in distilled water at 37ºC. Five readings per specimen were taken for each specimen regarding surface roughness and microhardness. After immersion in basic fuchsin, microleakage was evaluated (X40) using standardized scores. Data were analyzed at significance level of 0.05 with analysis of variance and a SNK test (surface roughness and microhardness) or with Mann-Whitney and Kruskal-Wallis (microleakage). For comparison between baseline and one-year Student´s t test (Ra) and Mann-Withney (microleakage) were carried out. After one-year, in general microfilled composite specimens showed lower roughness and hardness. No difference regarding microleakage was observed among different groups, but better sealing was observed in enamel margins. The sequential technique provided the lowest roughness and the Sof-Lex the lowest hardness in the most of the experimental conditions. Aging increased composite roughness. Immediate polishing showed similar or better performance than delayed polishing for microleakage and surface roughness, but this was not observed for microhardness, except in sequential technique groups |
id |
UFPL_d9660b2fb7ef8501ef956438d34fdb77 |
---|---|
oai_identifier_str |
oai:guaiaca.ufpel.edu.br:123456789/2291 |
network_acronym_str |
UFPL |
network_name_str |
Repositório Institucional da UFPel - Guaiaca |
repository_id_str |
|
spelling |
2014-08-20T14:30:17Z2014-02-112014-08-20T14:30:17Z2006-06-30VENTURINI, Daniela. Effect of polishing techniques and time on surface roughness, microhardness and microleakage of resin composite restorations after oneyear storage. 2006. 71 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Pelotas, Pelotas, 2006.http://repositorio.ufpel.edu.br/handle/ri/2291This study evaluated the effects of immediate and delayed polishing on surface roughness (Ra), microhardness (KHN) and microleakage of a microfilled composite (Filtek A110) and a hybrid composite (Filtek Z250) restorations after one-year storage. Standardized cavities preparations were made in the buccal surface of 256 bovine teeth; half were restored with each composite. Immediately after photo activation finishing was carried out with #280 grit sandpaper. For each composite, the specimens were randomly allocated for two sub-groups. The first group (IM) was immediately polished, using three different systems (n=16): A- Sof-Lex; B- Flexicups; and C- a sequential technique using Flexicups, Jiffy Polishing Brush and Flexibuffs. The specimens were stored in saline solution at 37ºC. The second group (DE) was stored for two weeks and then polished with the same systems. Part of the specimens had their surface properties analyzed at the baseline, and the remaining specimens were stored for one-year in distilled water at 37ºC. Five readings per specimen were taken for each specimen regarding surface roughness and microhardness. After immersion in basic fuchsin, microleakage was evaluated (X40) using standardized scores. Data were analyzed at significance level of 0.05 with analysis of variance and a SNK test (surface roughness and microhardness) or with Mann-Whitney and Kruskal-Wallis (microleakage). For comparison between baseline and one-year Student´s t test (Ra) and Mann-Withney (microleakage) were carried out. After one-year, in general microfilled composite specimens showed lower roughness and hardness. No difference regarding microleakage was observed among different groups, but better sealing was observed in enamel margins. The sequential technique provided the lowest roughness and the Sof-Lex the lowest hardness in the most of the experimental conditions. Aging increased composite roughness. Immediate polishing showed similar or better performance than delayed polishing for microleakage and surface roughness, but this was not observed for microhardness, except in sequential technique groupsEste estudo avaliou os efeitos do polimento imediato e mediato na rugosidade média superficial (Ra), dureza Knoop (KHN) e microinfiltração de um compósito microparticulado (Filtek A110) e um híbrido (Filtek Z250), após um ano de armazenagem dos espécimes. Preparos padronizados de 3mm mesio-distais, 3mm inciso-cervicais e 2mm de profundidade foram realizados na face vestibular de 256 incisivos bovinos, metade destes foi restaurada com cada tipo de compósito. Imediatamente após a fotoativação realizado o acabamento com lixa d água de granulação 280. Os espécimes restaurados com cada compósito foram divididos em dois grupos. O primeiro grupo (IM) foi polido imediatamente após o acabamento, usando três sistemas diferentes (n=16): A- Sof-Lex (3M-ESPE), B- FlexiCups (Cosmedent), C- (técnica seqüencial)- a seqüência de FlexiCups, Jiffy Polishing Brush (Ultradent) e FlexiBuffs (Cosmedent). Os espécimes foram então armazenados em solução salina a 37ºC. O segundo grupo (ME) foi armazenado por duas semanas e então polido com os mesmos sistemas. Parte dos espécimes foi analisada numa primeira etapa do experimento e o restante ficou armazenado por um ano em água destilada a 37ºC. Cinco leituras por espécimes foram realizadas para Ra e KHN. Após imersão em fucsina básica realizou-se o teste de penetração de corante sendo após analisado sob aumento (40x) usando escores padrão. Os dados foram verificados através de Análise de Variância e teste SNK (Ra e KHN). Também foram utilizados os testes de Mann-Whitney ou Kruskal-Wallis (microinfiltração). Para comparação com os dados baseline foram utilizados os testes t de Student (Ra) e Mann-Withney (infiltração marginal). Todos os testes foram executados com significância de 5%. Após um ano de armazenagem os espécimes do compósito A110 apresentaram significativamente menor rugosidade e menor dureza. A técnica seqüencial promoveu a menor rugosidade e os discos Sof-Lex a menor dureza, essas diferenças foram estatisticamente significantes. Os escores de infiltração marginal foram semelhantes entre os grupos. Após um ano de armazenagem os espécimes apresentaram um aumento significativo na rugosidade. O polimento IM mostrou-se igual, ou melhor, que o ME tanto para a infiltração marginal como para a rugosidade superficial para a maioria dos grupos analisados, no entanto tal fato não foi observado quanto à dureza superficial, exceto quando foi utilizada a técnica seqüencialapplication/pdfporUniversidade Federal de PelotasPrograma de Pós-Graduação em OdontologiaUFPelBROdontologiaPolimento dentárioResina compostaArmazenagemMicroinfiltraçãoDurezaRugosidade superficialDental PolishingComposite ResinStorageDental microleakageMicrohardnessSurface roughnessCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIAEfeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagemEffect of polishing techniques and time on surface roughness, microhardness and microleakage of resin composite restorations after oneyear storageinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://lattes.cnpq.br/0623833844256426http://lattes.cnpq.br/5439768560638141Piva, Evandrohttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4701753T0Demarco, Flávio FernandoVenturini, Danielainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFPel - Guaiacainstname:Universidade Federal de Pelotas (UFPEL)instacron:UFPELORIGINALDissertacao_Daniela_Venturini.pdfapplication/pdf913438http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2291/1/Dissertacao_Daniela_Venturini.pdfe17fa4ddbe1c025e3411319cac841d1eMD51open accessTEXTDissertacao_Daniela_Venturini.pdf.txtDissertacao_Daniela_Venturini.pdf.txtExtracted Texttext/plain128628http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2291/2/Dissertacao_Daniela_Venturini.pdf.txte3b424bbb78dce89072f1c6ede6f9da3MD52open accessTHUMBNAILDissertacao_Daniela_Venturini.pdf.jpgDissertacao_Daniela_Venturini.pdf.jpgGenerated Thumbnailimage/jpeg1453http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2291/3/Dissertacao_Daniela_Venturini.pdf.jpg2e00b3bf23e283fc15771a9712b5edf4MD53open access123456789/22912019-09-13 09:33:59.867open accessoai:guaiaca.ufpel.edu.br:123456789/2291Repositório InstitucionalPUBhttp://repositorio.ufpel.edu.br/oai/requestrippel@ufpel.edu.br || repositorio@ufpel.edu.br || aline.batista@ufpel.edu.bropendoar:2019-09-13T12:33:59Repositório Institucional da UFPel - Guaiaca - Universidade Federal de Pelotas (UFPEL)false |
dc.title.por.fl_str_mv |
Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem |
dc.title.alternative.eng.fl_str_mv |
Effect of polishing techniques and time on surface roughness, microhardness and microleakage of resin composite restorations after oneyear storage |
title |
Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem |
spellingShingle |
Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem Venturini, Daniela Polimento dentário Resina composta Armazenagem Microinfiltração Dureza Rugosidade superficial Dental Polishing Composite Resin Storage Dental microleakage Microhardness Surface roughness CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
title_short |
Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem |
title_full |
Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem |
title_fullStr |
Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem |
title_full_unstemmed |
Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem |
title_sort |
Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem |
author |
Venturini, Daniela |
author_facet |
Venturini, Daniela |
author_role |
author |
dc.contributor.authorLattes.por.fl_str_mv |
http://lattes.cnpq.br/0623833844256426 |
dc.contributor.advisorLattes.por.fl_str_mv |
http://lattes.cnpq.br/5439768560638141 |
dc.contributor.advisor-co1.fl_str_mv |
Piva, Evandro |
dc.contributor.advisor-co1Lattes.fl_str_mv |
http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4701753T0 |
dc.contributor.advisor1.fl_str_mv |
Demarco, Flávio Fernando |
dc.contributor.author.fl_str_mv |
Venturini, Daniela |
contributor_str_mv |
Piva, Evandro Demarco, Flávio Fernando |
dc.subject.por.fl_str_mv |
Polimento dentário Resina composta Armazenagem Microinfiltração Dureza Rugosidade superficial |
topic |
Polimento dentário Resina composta Armazenagem Microinfiltração Dureza Rugosidade superficial Dental Polishing Composite Resin Storage Dental microleakage Microhardness Surface roughness CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
dc.subject.eng.fl_str_mv |
Dental Polishing Composite Resin Storage Dental microleakage Microhardness Surface roughness |
dc.subject.cnpq.fl_str_mv |
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
description |
This study evaluated the effects of immediate and delayed polishing on surface roughness (Ra), microhardness (KHN) and microleakage of a microfilled composite (Filtek A110) and a hybrid composite (Filtek Z250) restorations after one-year storage. Standardized cavities preparations were made in the buccal surface of 256 bovine teeth; half were restored with each composite. Immediately after photo activation finishing was carried out with #280 grit sandpaper. For each composite, the specimens were randomly allocated for two sub-groups. The first group (IM) was immediately polished, using three different systems (n=16): A- Sof-Lex; B- Flexicups; and C- a sequential technique using Flexicups, Jiffy Polishing Brush and Flexibuffs. The specimens were stored in saline solution at 37ºC. The second group (DE) was stored for two weeks and then polished with the same systems. Part of the specimens had their surface properties analyzed at the baseline, and the remaining specimens were stored for one-year in distilled water at 37ºC. Five readings per specimen were taken for each specimen regarding surface roughness and microhardness. After immersion in basic fuchsin, microleakage was evaluated (X40) using standardized scores. Data were analyzed at significance level of 0.05 with analysis of variance and a SNK test (surface roughness and microhardness) or with Mann-Whitney and Kruskal-Wallis (microleakage). For comparison between baseline and one-year Student´s t test (Ra) and Mann-Withney (microleakage) were carried out. After one-year, in general microfilled composite specimens showed lower roughness and hardness. No difference regarding microleakage was observed among different groups, but better sealing was observed in enamel margins. The sequential technique provided the lowest roughness and the Sof-Lex the lowest hardness in the most of the experimental conditions. Aging increased composite roughness. Immediate polishing showed similar or better performance than delayed polishing for microleakage and surface roughness, but this was not observed for microhardness, except in sequential technique groups |
publishDate |
2006 |
dc.date.issued.fl_str_mv |
2006-06-30 |
dc.date.accessioned.fl_str_mv |
2014-08-20T14:30:17Z |
dc.date.available.fl_str_mv |
2014-02-11 2014-08-20T14:30:17Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
VENTURINI, Daniela. Effect of polishing techniques and time on surface roughness, microhardness and microleakage of resin composite restorations after oneyear storage. 2006. 71 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Pelotas, Pelotas, 2006. |
dc.identifier.uri.fl_str_mv |
http://repositorio.ufpel.edu.br/handle/ri/2291 |
identifier_str_mv |
VENTURINI, Daniela. Effect of polishing techniques and time on surface roughness, microhardness and microleakage of resin composite restorations after oneyear storage. 2006. 71 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Pelotas, Pelotas, 2006. |
url |
http://repositorio.ufpel.edu.br/handle/ri/2291 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Pelotas |
dc.publisher.program.fl_str_mv |
Programa de Pós-Graduação em Odontologia |
dc.publisher.initials.fl_str_mv |
UFPel |
dc.publisher.country.fl_str_mv |
BR |
dc.publisher.department.fl_str_mv |
Odontologia |
publisher.none.fl_str_mv |
Universidade Federal de Pelotas |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFPel - Guaiaca instname:Universidade Federal de Pelotas (UFPEL) instacron:UFPEL |
instname_str |
Universidade Federal de Pelotas (UFPEL) |
instacron_str |
UFPEL |
institution |
UFPEL |
reponame_str |
Repositório Institucional da UFPel - Guaiaca |
collection |
Repositório Institucional da UFPel - Guaiaca |
bitstream.url.fl_str_mv |
http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2291/1/Dissertacao_Daniela_Venturini.pdf http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2291/2/Dissertacao_Daniela_Venturini.pdf.txt http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2291/3/Dissertacao_Daniela_Venturini.pdf.jpg |
bitstream.checksum.fl_str_mv |
e17fa4ddbe1c025e3411319cac841d1e e3b424bbb78dce89072f1c6ede6f9da3 2e00b3bf23e283fc15771a9712b5edf4 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFPel - Guaiaca - Universidade Federal de Pelotas (UFPEL) |
repository.mail.fl_str_mv |
rippel@ufpel.edu.br || repositorio@ufpel.edu.br || aline.batista@ufpel.edu.br |
_version_ |
1801846987922866176 |