Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem

Detalhes bibliográficos
Autor(a) principal: Venturini, Daniela
Data de Publicação: 2006
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFPel - Guaiaca
Texto Completo: http://repositorio.ufpel.edu.br/handle/ri/2291
Resumo: This study evaluated the effects of immediate and delayed polishing on surface roughness (Ra), microhardness (KHN) and microleakage of a microfilled composite (Filtek A110) and a hybrid composite (Filtek Z250) restorations after one-year storage. Standardized cavities preparations were made in the buccal surface of 256 bovine teeth; half were restored with each composite. Immediately after photo activation finishing was carried out with #280 grit sandpaper. For each composite, the specimens were randomly allocated for two sub-groups. The first group (IM) was immediately polished, using three different systems (n=16): A- Sof-Lex; B- Flexicups; and C- a sequential technique using Flexicups, Jiffy Polishing Brush and Flexibuffs. The specimens were stored in saline solution at 37ºC. The second group (DE) was stored for two weeks and then polished with the same systems. Part of the specimens had their surface properties analyzed at the baseline, and the remaining specimens were stored for one-year in distilled water at 37ºC. Five readings per specimen were taken for each specimen regarding surface roughness and microhardness. After immersion in basic fuchsin, microleakage was evaluated (X40) using standardized scores. Data were analyzed at significance level of 0.05 with analysis of variance and a SNK test (surface roughness and microhardness) or with Mann-Whitney and Kruskal-Wallis (microleakage). For comparison between baseline and one-year Student´s t test (Ra) and Mann-Withney (microleakage) were carried out. After one-year, in general microfilled composite specimens showed lower roughness and hardness. No difference regarding microleakage was observed among different groups, but better sealing was observed in enamel margins. The sequential technique provided the lowest roughness and the Sof-Lex the lowest hardness in the most of the experimental conditions. Aging increased composite roughness. Immediate polishing showed similar or better performance than delayed polishing for microleakage and surface roughness, but this was not observed for microhardness, except in sequential technique groups
id UFPL_d9660b2fb7ef8501ef956438d34fdb77
oai_identifier_str oai:guaiaca.ufpel.edu.br:123456789/2291
network_acronym_str UFPL
network_name_str Repositório Institucional da UFPel - Guaiaca
repository_id_str
spelling 2014-08-20T14:30:17Z2014-02-112014-08-20T14:30:17Z2006-06-30VENTURINI, Daniela. Effect of polishing techniques and time on surface roughness, microhardness and microleakage of resin composite restorations after oneyear storage. 2006. 71 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Pelotas, Pelotas, 2006.http://repositorio.ufpel.edu.br/handle/ri/2291This study evaluated the effects of immediate and delayed polishing on surface roughness (Ra), microhardness (KHN) and microleakage of a microfilled composite (Filtek A110) and a hybrid composite (Filtek Z250) restorations after one-year storage. Standardized cavities preparations were made in the buccal surface of 256 bovine teeth; half were restored with each composite. Immediately after photo activation finishing was carried out with #280 grit sandpaper. For each composite, the specimens were randomly allocated for two sub-groups. The first group (IM) was immediately polished, using three different systems (n=16): A- Sof-Lex; B- Flexicups; and C- a sequential technique using Flexicups, Jiffy Polishing Brush and Flexibuffs. The specimens were stored in saline solution at 37ºC. The second group (DE) was stored for two weeks and then polished with the same systems. Part of the specimens had their surface properties analyzed at the baseline, and the remaining specimens were stored for one-year in distilled water at 37ºC. Five readings per specimen were taken for each specimen regarding surface roughness and microhardness. After immersion in basic fuchsin, microleakage was evaluated (X40) using standardized scores. Data were analyzed at significance level of 0.05 with analysis of variance and a SNK test (surface roughness and microhardness) or with Mann-Whitney and Kruskal-Wallis (microleakage). For comparison between baseline and one-year Student´s t test (Ra) and Mann-Withney (microleakage) were carried out. After one-year, in general microfilled composite specimens showed lower roughness and hardness. No difference regarding microleakage was observed among different groups, but better sealing was observed in enamel margins. The sequential technique provided the lowest roughness and the Sof-Lex the lowest hardness in the most of the experimental conditions. Aging increased composite roughness. Immediate polishing showed similar or better performance than delayed polishing for microleakage and surface roughness, but this was not observed for microhardness, except in sequential technique groupsEste estudo avaliou os efeitos do polimento imediato e mediato na rugosidade média superficial (Ra), dureza Knoop (KHN) e microinfiltração de um compósito microparticulado (Filtek A110) e um híbrido (Filtek Z250), após um ano de armazenagem dos espécimes. Preparos padronizados de 3mm mesio-distais, 3mm inciso-cervicais e 2mm de profundidade foram realizados na face vestibular de 256 incisivos bovinos, metade destes foi restaurada com cada tipo de compósito. Imediatamente após a fotoativação realizado o acabamento com lixa d água de granulação 280. Os espécimes restaurados com cada compósito foram divididos em dois grupos. O primeiro grupo (IM) foi polido imediatamente após o acabamento, usando três sistemas diferentes (n=16): A- Sof-Lex (3M-ESPE), B- FlexiCups (Cosmedent), C- (técnica seqüencial)- a seqüência de FlexiCups, Jiffy Polishing Brush (Ultradent) e FlexiBuffs (Cosmedent). Os espécimes foram então armazenados em solução salina a 37ºC. O segundo grupo (ME) foi armazenado por duas semanas e então polido com os mesmos sistemas. Parte dos espécimes foi analisada numa primeira etapa do experimento e o restante ficou armazenado por um ano em água destilada a 37ºC. Cinco leituras por espécimes foram realizadas para Ra e KHN. Após imersão em fucsina básica realizou-se o teste de penetração de corante sendo após analisado sob aumento (40x) usando escores padrão. Os dados foram verificados através de Análise de Variância e teste SNK (Ra e KHN). Também foram utilizados os testes de Mann-Whitney ou Kruskal-Wallis (microinfiltração). Para comparação com os dados baseline foram utilizados os testes t de Student (Ra) e Mann-Withney (infiltração marginal). Todos os testes foram executados com significância de 5%. Após um ano de armazenagem os espécimes do compósito A110 apresentaram significativamente menor rugosidade e menor dureza. A técnica seqüencial promoveu a menor rugosidade e os discos Sof-Lex a menor dureza, essas diferenças foram estatisticamente significantes. Os escores de infiltração marginal foram semelhantes entre os grupos. Após um ano de armazenagem os espécimes apresentaram um aumento significativo na rugosidade. O polimento IM mostrou-se igual, ou melhor, que o ME tanto para a infiltração marginal como para a rugosidade superficial para a maioria dos grupos analisados, no entanto tal fato não foi observado quanto à dureza superficial, exceto quando foi utilizada a técnica seqüencialapplication/pdfporUniversidade Federal de PelotasPrograma de Pós-Graduação em OdontologiaUFPelBROdontologiaPolimento dentárioResina compostaArmazenagemMicroinfiltraçãoDurezaRugosidade superficialDental PolishingComposite ResinStorageDental microleakageMicrohardnessSurface roughnessCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIAEfeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagemEffect of polishing techniques and time on surface roughness, microhardness and microleakage of resin composite restorations after oneyear storageinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://lattes.cnpq.br/0623833844256426http://lattes.cnpq.br/5439768560638141Piva, Evandrohttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4701753T0Demarco, Flávio FernandoVenturini, Danielainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFPel - Guaiacainstname:Universidade Federal de Pelotas (UFPEL)instacron:UFPELORIGINALDissertacao_Daniela_Venturini.pdfapplication/pdf913438http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2291/1/Dissertacao_Daniela_Venturini.pdfe17fa4ddbe1c025e3411319cac841d1eMD51open accessTEXTDissertacao_Daniela_Venturini.pdf.txtDissertacao_Daniela_Venturini.pdf.txtExtracted Texttext/plain128628http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2291/2/Dissertacao_Daniela_Venturini.pdf.txte3b424bbb78dce89072f1c6ede6f9da3MD52open accessTHUMBNAILDissertacao_Daniela_Venturini.pdf.jpgDissertacao_Daniela_Venturini.pdf.jpgGenerated Thumbnailimage/jpeg1453http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2291/3/Dissertacao_Daniela_Venturini.pdf.jpg2e00b3bf23e283fc15771a9712b5edf4MD53open access123456789/22912019-09-13 09:33:59.867open accessoai:guaiaca.ufpel.edu.br:123456789/2291Repositório InstitucionalPUBhttp://repositorio.ufpel.edu.br/oai/requestrippel@ufpel.edu.br || repositorio@ufpel.edu.br || aline.batista@ufpel.edu.bropendoar:2019-09-13T12:33:59Repositório Institucional da UFPel - Guaiaca - Universidade Federal de Pelotas (UFPEL)false
dc.title.por.fl_str_mv Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem
dc.title.alternative.eng.fl_str_mv Effect of polishing techniques and time on surface roughness, microhardness and microleakage of resin composite restorations after oneyear storage
title Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem
spellingShingle Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem
Venturini, Daniela
Polimento dentário
Resina composta
Armazenagem
Microinfiltração
Dureza
Rugosidade superficial
Dental Polishing
Composite Resin
Storage
Dental microleakage
Microhardness
Surface roughness
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
title_short Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem
title_full Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem
title_fullStr Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem
title_full_unstemmed Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem
title_sort Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem
author Venturini, Daniela
author_facet Venturini, Daniela
author_role author
dc.contributor.authorLattes.por.fl_str_mv http://lattes.cnpq.br/0623833844256426
dc.contributor.advisorLattes.por.fl_str_mv http://lattes.cnpq.br/5439768560638141
dc.contributor.advisor-co1.fl_str_mv Piva, Evandro
dc.contributor.advisor-co1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4701753T0
dc.contributor.advisor1.fl_str_mv Demarco, Flávio Fernando
dc.contributor.author.fl_str_mv Venturini, Daniela
contributor_str_mv Piva, Evandro
Demarco, Flávio Fernando
dc.subject.por.fl_str_mv Polimento dentário
Resina composta
Armazenagem
Microinfiltração
Dureza
Rugosidade superficial
topic Polimento dentário
Resina composta
Armazenagem
Microinfiltração
Dureza
Rugosidade superficial
Dental Polishing
Composite Resin
Storage
Dental microleakage
Microhardness
Surface roughness
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
dc.subject.eng.fl_str_mv Dental Polishing
Composite Resin
Storage
Dental microleakage
Microhardness
Surface roughness
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
description This study evaluated the effects of immediate and delayed polishing on surface roughness (Ra), microhardness (KHN) and microleakage of a microfilled composite (Filtek A110) and a hybrid composite (Filtek Z250) restorations after one-year storage. Standardized cavities preparations were made in the buccal surface of 256 bovine teeth; half were restored with each composite. Immediately after photo activation finishing was carried out with #280 grit sandpaper. For each composite, the specimens were randomly allocated for two sub-groups. The first group (IM) was immediately polished, using three different systems (n=16): A- Sof-Lex; B- Flexicups; and C- a sequential technique using Flexicups, Jiffy Polishing Brush and Flexibuffs. The specimens were stored in saline solution at 37ºC. The second group (DE) was stored for two weeks and then polished with the same systems. Part of the specimens had their surface properties analyzed at the baseline, and the remaining specimens were stored for one-year in distilled water at 37ºC. Five readings per specimen were taken for each specimen regarding surface roughness and microhardness. After immersion in basic fuchsin, microleakage was evaluated (X40) using standardized scores. Data were analyzed at significance level of 0.05 with analysis of variance and a SNK test (surface roughness and microhardness) or with Mann-Whitney and Kruskal-Wallis (microleakage). For comparison between baseline and one-year Student´s t test (Ra) and Mann-Withney (microleakage) were carried out. After one-year, in general microfilled composite specimens showed lower roughness and hardness. No difference regarding microleakage was observed among different groups, but better sealing was observed in enamel margins. The sequential technique provided the lowest roughness and the Sof-Lex the lowest hardness in the most of the experimental conditions. Aging increased composite roughness. Immediate polishing showed similar or better performance than delayed polishing for microleakage and surface roughness, but this was not observed for microhardness, except in sequential technique groups
publishDate 2006
dc.date.issued.fl_str_mv 2006-06-30
dc.date.accessioned.fl_str_mv 2014-08-20T14:30:17Z
dc.date.available.fl_str_mv 2014-02-11
2014-08-20T14:30:17Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv VENTURINI, Daniela. Effect of polishing techniques and time on surface roughness, microhardness and microleakage of resin composite restorations after oneyear storage. 2006. 71 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Pelotas, Pelotas, 2006.
dc.identifier.uri.fl_str_mv http://repositorio.ufpel.edu.br/handle/ri/2291
identifier_str_mv VENTURINI, Daniela. Effect of polishing techniques and time on surface roughness, microhardness and microleakage of resin composite restorations after oneyear storage. 2006. 71 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Pelotas, Pelotas, 2006.
url http://repositorio.ufpel.edu.br/handle/ri/2291
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Pelotas
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Odontologia
dc.publisher.initials.fl_str_mv UFPel
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Odontologia
publisher.none.fl_str_mv Universidade Federal de Pelotas
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFPel - Guaiaca
instname:Universidade Federal de Pelotas (UFPEL)
instacron:UFPEL
instname_str Universidade Federal de Pelotas (UFPEL)
instacron_str UFPEL
institution UFPEL
reponame_str Repositório Institucional da UFPel - Guaiaca
collection Repositório Institucional da UFPel - Guaiaca
bitstream.url.fl_str_mv http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2291/1/Dissertacao_Daniela_Venturini.pdf
http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2291/2/Dissertacao_Daniela_Venturini.pdf.txt
http://guaiaca.ufpel.edu.br/xmlui/bitstream/123456789/2291/3/Dissertacao_Daniela_Venturini.pdf.jpg
bitstream.checksum.fl_str_mv e17fa4ddbe1c025e3411319cac841d1e
e3b424bbb78dce89072f1c6ede6f9da3
2e00b3bf23e283fc15771a9712b5edf4
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFPel - Guaiaca - Universidade Federal de Pelotas (UFPEL)
repository.mail.fl_str_mv rippel@ufpel.edu.br || repositorio@ufpel.edu.br || aline.batista@ufpel.edu.br
_version_ 1801846987922866176