Programa de controle de qualidade em hematologia : variaçoes interlaboratoriais para eritrograma e plaquetas em Curitiba e regiao metropolitada-PR.

Detalhes bibliográficos
Autor(a) principal: Hauser, Aline Borsato
Data de Publicação: 2003
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFPR
Texto Completo: https://hdl.handle.net/1884/27847
Resumo: Orientadora : Maria Suely Soares Leonart
id UFPR_32af597a6df75aa882f7e9e80ba58cef
oai_identifier_str oai:acervodigital.ufpr.br:1884/27847
network_acronym_str UFPR
network_name_str Repositório Institucional da UFPR
repository_id_str 308
spelling Hauser, Aline BorsatoNascimento, Aguinaldo José do, 1946-Universidade Federal do Paraná. Setor de Ciências da SaúdeLeonart, Maria Suely Soares, 1949-2020-03-10T20:11:32Z2020-03-10T20:11:32Z2003https://hdl.handle.net/1884/27847Orientadora : Maria Suely Soares LeonartCo-orientador : Aguinaldo José do NascimentoDissertaçao (mestrado) - Universidade Federal do Paraná, Setor de Ciencias da SaúdeResumo: O Controle de Qualidade em Laboratórios de Análises Clínicas visa aumentar a probabilidade de se obter resultados adequados para o diagnóstico e a terapêutica. Para a obtenção de valores hematológicos confiáveis, é imprescindível o emprego de amostras controle estáveis, como parte de programas de Controle de Qualidade. Esse projeto teve como objetivo avaliar a padronização e o controle de qualidade em hematologia, através do estudo das possíveis variações interlaboratoriais em 14 Laboratórios de Análises Clínicas em Curitiba e Região Metropolitana - PR, na análise de amostras controle estáveis para os valores do eritrograma e contagem de plaquetas. Foram preparadas amostras estáveis para os valores de eritrócitos, hemoglobina, VG, VCM, HCM, CHCM e contagem de plaquetas, a partir de unidades de sangue venoso de 3 doadores considerados normais, após seu consentimento informado, coletadas no Banco de Sangue do Hospital de Clínicas da UFPR. Os eritrócitos foram isolados e ressuspensos em meio CE após fixação parcial com glutaraldeído 5 mmoles/l durante 60 min, com volume globular aproximado de 60, 45 e 30%, respectivamente, para amostras controle altas, médias e baixas. Alíquotas das amostras, mantidas a 4°C, foram distribuídas aos laboratórios numerados aleatoriamente de 1 a 14, que determinaram os valores do eritrograma e plaquetas semanalmente, de acordo com instruções pré-estabelecidas, empregando os aparelhos automatizados T890 e STKS (Coulter), CellDyn 1400, 1700 e 3500 (Abbott) e Sysmex (Roche). Comprovou-se a estabilidade das amostras durante a preservação para os valores hematimétricos, pela obtenção do coeficiente de determinação (r2) próximo de zero. A comparação dos valores médios de r2 em função do tempo para as medidas hematimétricas mostrou que não houve diferença estatisticamente significativa para os 3 níveis de controle (p>0,05). A amostra controle média mostrou menor dispersão em torno da média que as amostras altas e baixas para eritrócitos, hemoglobina e volume globular (p<0,05). Esses resultados sugerem que a relação mais equivalente entre o volume de células e o volume de meio CE resulta em menor variabilidade dos dados durante o armazenamento. Verificou-se o desempenho dos laboratórios por meio dos gráficos de controle de qualidade, detemninando-se a frequência com que os laboratórios e os equipamentos apresentaram resultados fora dos limites controle e observando-se uma ocorrência mínima fora desses limites para os laboratórios que realizam CQE e CQI. Considerou-se as amostras adequadas para uso em controle de qualidade em laboratórios, mantendo-se estáveis durante 11 semanas e que os resultados obtidos incentivam a utilização de sistemas de qualidade para assegurar a padronização das técnicas e garantir o controle de qualidade nos Laboratórios de Análises Clínicas.Abstract: The Quality Control in Laboratories of Clinical Analyses seeks to increase the probability of obtaining adequate results for the diagnosis and the therapeutics. In order to obtain reliable values in hematology it is necessary the employment of stable control samples, as part of programs of Quality Control. The aim of this work was to analyze the standardization and the quality control in hematology, through the study of the possible interlaboratorial variations in 14 Laboratories of Clinical Analyses in Curitiba and Metropolitan Area-PR, using stable control samples for the values of the red cells and platelets. Stable samples for the red cell values, hemoglobin, PCV, MCV, MCH, MCHC and platelets counts were prepared from 3 healthy donors' venous blood. The bloods were collected at the Blood Bank of the Hospital de Clinicas, UFPR after the informed consent. The isolated red blood cells were partially fixed with glutaraldehyde 5 mmoles/l during 60 min, and ressuspended in CE solution at approximated 60, 45, and 30% PCV, called respectively, high, medium, and low control samples. Aliquots of the samples maintained at 4 °C were randomly numbered 1 - 1 4 and distributed to the participant laboratories that weekly determined the red cell values and platelets according to previous instructions, using automated equipments T890 and STKS (Coulter), CellDyn 1400, 1700 and 3500 (Abbott) and Sysmex (Roche). Stability of the samples for the hematology values as a function of time was observed during the preservation, obtaining the determination coefficient (r2) close to zero. The r2 was analyzed for average and variance values and compared for the high, medium, and low control samples. The comparison of the average values of r2 for the hematology values showed that there were no statistically significant differences among the 3 control levels (p>0.05). The medium control sample showed smaller dispersion around the average then the high and low controls for hemoglobin and PCV (p <0.05), i.e. best results were obtained with the medium control sample (control sample at 45% PCV). The performance of the laboratories was analyzed by means of the quality control charts observing the frequency the laboratories and the equipments presented results out of the control limits. Minimum occurrences were observed with laboratories that accomplish EQC and IQC programs. It can be concluded that the analyzed samples presented stability during 11 weeks and was adequate for use in quality control in hematology, and we expect that the obtained results can motivate the use of quality systems to assure the standardization of the techniques and to guarantee the quality control in the Laboratories of Clinical Analyses.xvii, 118f. : il. color., tabs., grafs.application/pdfHematologiaLaboratorios - Controle de qualidadePrograma de controle de qualidade em hematologia : variaçoes interlaboratoriais para eritrograma e plaquetas em Curitiba e regiao metropolitada-PR.info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisporreponame:Repositório Institucional da UFPRinstname:Universidade Federal do Paraná (UFPR)instacron:UFPRinfo:eu-repo/semantics/openAccessORIGINALD - HAUSER, ALINE BORSATO.pdfapplication/pdf4398555https://acervodigital.ufpr.br/bitstream/1884/27847/1/D%20-%20HAUSER%2c%20ALINE%20BORSATO.pdf434917d6b42fb9ac951ed0c27352d9faMD51open accessTEXTD - HAUSER, ALINE BORSATO.pdf.txtExtracted Texttext/plain195695https://acervodigital.ufpr.br/bitstream/1884/27847/2/D%20-%20HAUSER%2c%20ALINE%20BORSATO.pdf.txt91295fb90f2008a3a4eb7501c08edbf4MD52open accessTHUMBNAILD - HAUSER, ALINE BORSATO.pdf.jpgGenerated Thumbnailimage/jpeg1316https://acervodigital.ufpr.br/bitstream/1884/27847/3/D%20-%20HAUSER%2c%20ALINE%20BORSATO.pdf.jpg305a7cd3ecf593b5af1108dedce5e6d5MD53open access1884/278472020-03-10 17:11:32.826open accessoai:acervodigital.ufpr.br:1884/27847Repositório de PublicaçõesPUBhttp://acervodigital.ufpr.br/oai/requestopendoar:3082020-03-10T20:11:32Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)false
dc.title.pt_BR.fl_str_mv Programa de controle de qualidade em hematologia : variaçoes interlaboratoriais para eritrograma e plaquetas em Curitiba e regiao metropolitada-PR.
title Programa de controle de qualidade em hematologia : variaçoes interlaboratoriais para eritrograma e plaquetas em Curitiba e regiao metropolitada-PR.
spellingShingle Programa de controle de qualidade em hematologia : variaçoes interlaboratoriais para eritrograma e plaquetas em Curitiba e regiao metropolitada-PR.
Hauser, Aline Borsato
Hematologia
Laboratorios - Controle de qualidade
title_short Programa de controle de qualidade em hematologia : variaçoes interlaboratoriais para eritrograma e plaquetas em Curitiba e regiao metropolitada-PR.
title_full Programa de controle de qualidade em hematologia : variaçoes interlaboratoriais para eritrograma e plaquetas em Curitiba e regiao metropolitada-PR.
title_fullStr Programa de controle de qualidade em hematologia : variaçoes interlaboratoriais para eritrograma e plaquetas em Curitiba e regiao metropolitada-PR.
title_full_unstemmed Programa de controle de qualidade em hematologia : variaçoes interlaboratoriais para eritrograma e plaquetas em Curitiba e regiao metropolitada-PR.
title_sort Programa de controle de qualidade em hematologia : variaçoes interlaboratoriais para eritrograma e plaquetas em Curitiba e regiao metropolitada-PR.
author Hauser, Aline Borsato
author_facet Hauser, Aline Borsato
author_role author
dc.contributor.other.pt_BR.fl_str_mv Nascimento, Aguinaldo José do, 1946-
Universidade Federal do Paraná. Setor de Ciências da Saúde
dc.contributor.author.fl_str_mv Hauser, Aline Borsato
dc.contributor.advisor1.fl_str_mv Leonart, Maria Suely Soares, 1949-
contributor_str_mv Leonart, Maria Suely Soares, 1949-
dc.subject.por.fl_str_mv Hematologia
Laboratorios - Controle de qualidade
topic Hematologia
Laboratorios - Controle de qualidade
description Orientadora : Maria Suely Soares Leonart
publishDate 2003
dc.date.issued.fl_str_mv 2003
dc.date.accessioned.fl_str_mv 2020-03-10T20:11:32Z
dc.date.available.fl_str_mv 2020-03-10T20:11:32Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1884/27847
url https://hdl.handle.net/1884/27847
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv xvii, 118f. : il. color., tabs., grafs.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFPR
instname:Universidade Federal do Paraná (UFPR)
instacron:UFPR
instname_str Universidade Federal do Paraná (UFPR)
instacron_str UFPR
institution UFPR
reponame_str Repositório Institucional da UFPR
collection Repositório Institucional da UFPR
bitstream.url.fl_str_mv https://acervodigital.ufpr.br/bitstream/1884/27847/1/D%20-%20HAUSER%2c%20ALINE%20BORSATO.pdf
https://acervodigital.ufpr.br/bitstream/1884/27847/2/D%20-%20HAUSER%2c%20ALINE%20BORSATO.pdf.txt
https://acervodigital.ufpr.br/bitstream/1884/27847/3/D%20-%20HAUSER%2c%20ALINE%20BORSATO.pdf.jpg
bitstream.checksum.fl_str_mv 434917d6b42fb9ac951ed0c27352d9fa
91295fb90f2008a3a4eb7501c08edbf4
305a7cd3ecf593b5af1108dedce5e6d5
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)
repository.mail.fl_str_mv
_version_ 1813898727554809856