Análise dos efeitos da redução da dose sobre a detecção de nódulos pulmonares em tomografias de tórax de baixa e de ultrabaixa dose para rastreamento de câncer de pulmão : (um estudo em fantoma)

Detalhes bibliográficos
Autor(a) principal: Leitão, Cleverson Alex, 1992-
Data de Publicação: 2020
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFPR
Texto Completo: https://hdl.handle.net/1884/70714
Resumo: Orientador: Prof. Dr. Dante Luiz Escuissato
id UFPR_bcd3e7a28b543ed194c58a93a69a3ff3
oai_identifier_str oai:acervodigital.ufpr.br:1884/70714
network_acronym_str UFPR
network_name_str Repositório Institucional da UFPR
repository_id_str 308
spelling Leitão, Cleverson Alex, 1992-Jakubiaki, Rosângela RekiUniversidade Federal do Paraná. Setor de Ciências da Saúde. Programa de Pós-Graduação em Medicina Interna e Ciências da SaúdeEscuissato, Dante Luiz2021-12-30T12:07:12Z2021-12-30T12:07:12Z2020https://hdl.handle.net/1884/70714Orientador: Prof. Dr. Dante Luiz EscuissatoCoorientadora: Profa. Dra. Rosângela Reki JakubiakiDissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Medicina Interna. Defesa : Curitiba, 28/08/2020Inclui referências: p. 57-61Resumo: A detecção de nódulos pulmonares por meio da tomografia computadorizada permite o diagnóstico precoce do câncer de pulmão, ajudando a reduzir sua mortalidade. Contudo, sabe-se que o uso da radiação ionizante inerente ao método está relacionado a potenciais efeitos deletérios, inclusive carcinogênese. Dessa forma, diferentes protocolos utilizando doses cada vez mais baixas de raios X têm sido desenvolvidos, na tentativa de dirimir a ocorrência dessas complicações. Doses menores, entretanto, podem comprometer a qualidade da imagem, levando a imagens não-diagnósticas, o que torna a busca do equilíbrio entre quantidade de radiação e qualidade de imagem um desafio da radiologia moderna. Este trabalho tem por objetivo avaliar o efeito da redução da dose em exames de tomografia computadorizada sobre a detecção de nódulos pulmonares, utilizando imagens de um fantoma que simula pulmões contendo nódulos. O simulador foi estudado com cinco protocolos diferentes (um protocolo de ultrabaixa dose, três de baixa dose e um convencional). Dentre os três protocolos de baixa dose, utilizamos aquele sugerido pela Associação Americana de Física Médica (baixa dose convencional) e dois protocolos experimentais (com kV reduzido e com mAs reduzido). Comparamos o desempenho de quatro especialistas em radiologia torácica na detecção dos nódulos em cada protocolo e o grau de concordância entre os diferentes observadores. Realizamos também o estudo da quantidade de dose em cada protocolo utilizando dosímetros termoluminescentes, a fim de comparar com precisão os níveis de radiação ionizante de cada protocolo. A dose equivalente no protocolo de ultrabaixa dose foi menor do que um terço (0,5 mSv) da dose do protocolo de baixa dose convencional (1,8 mSv). Os protocolos de baixa dose experimentais (com menor kV e menor mAs) levaram a discreta redução na dose efetiva em relação ao protocolo de baixa dose convencional (doses equivalentes de 1,34 mSv e 1,32 mSv). O protocolo convencional apresentou a dose mais alta (9 mSv). Não houve diferença estatisticamente significativa no desempenho dos participantes na detecção dos nódulos pulmonares comparando os protocolos de baixa dose entre si e com o protocolo de ultrabaixa dose (p = 0,208 a p=1,000), contudo, houve diferença significativa comparando-os com o protocolo convencional (p < 0,001). Para nódulos com menor densidade tomográfica (<-600 UH) também houve diferença significativa na taxa de detecção quando comparados os protocolos de ultrabaixa dose e baixa dose com a tomografia convencional (p < 0,001 a p = 0,007). O grau de concordância entre os diferentes observadores em todos os protocolos variou entre moderado (k = 0,41) e perfeito (k = 1,0). Esses fatos mostram que a performance dos radiologistas em protocolos de ultrabaixa dose e de baixa dose é comparável, oferecendo alternativas com doses inferiores a 1 mSv para a realização do rastreamento do câncer de pulmão. Palavras-chave: Tomografia computadorizada do tórax. Dosimetria. Nódulos pulmonares. Radiologia. Baixa dose.Abstract: The detection of lung nodules in computed tomography of the chest plays a major role in the early diagnosis of lung cancer, potentially reducing this disease's mortality. However, the use of ionizing radiation inherent to the method can eventually determine side effects, including carcinogenesis. This problem led to the development of protocols that use lower X ray doses as a way to minimize the risk of adverse outcomes. Though, lower doses can compromise the quality of the exam, even resulting in non-diagnostic images. This pursuit for the perfect balance between dose and image-quality is a challenge of modern radiology. This study aims to analyze the effects of dose reduction in computed tomography of the chest over the detection of simulated lung nodules in a phantom. The phantom was scanned using five different protocols (one ultra-low-dose, three low-dose and a conventional chest computed tomography). The three different low dose protocols consisted of the one recommended by the American Association of Physicists in Medicine (conventional low dose protocol) and two experimental protocols (lower kV and lower mAs). We compared the performance of four radiologists with expertise in chest radiology in detecting the nodules in each protocol and avaliated interobserver agreement. We also measured the ammount of radiation in each protocol using thermoluminescent dosimeters, in order to precisely compare their respective doses. The equivalent dose in the ultra-low-dose protocol was less than a third (0.5 mSv) of that of the conventional low-dose protocol (1.8 mSv). The experimental low-dose protocols (lower kV and lower mAs) led to discrete effective-dose reduction (1.34 and 1.32 mSv, respectively). There was no statistically significant difference in lung nodule detection when comparing different low-dose protocols with each other or with ultralow- dose protocol (p = 0.208 to p=1.000), however, difference was significant when comparing them to conventional CT (p < 0.001). Lower-attenuating nodules (<-600 UH) also had significant difference in detection rates when comparing ultra-low-dose and low-dose CT with conventional CT (p < 0.001 a p = 0.007). The level of agreement between different observers in all protocols ranged from moderate (k = 0.41) to perfect (k = 1.0). These facts show that the performance of radiologists is similar in low and ultra-low-dose protocols, offering alternatives with doses lower than 1 mSv to perform lung cancer screening. Keywords: Screening. Chest. Computed Tomography. Lung Cancer. Low dose61 p. : il. (algumas color.).application/pdfTomografia computadorizadaToraxPulmões - DoençasRadiologiaPulmão - CâncerNódulos Pulmonares MúltiplosAnálise dos efeitos da redução da dose sobre a detecção de nódulos pulmonares em tomografias de tórax de baixa e de ultrabaixa dose para rastreamento de câncer de pulmão : (um estudo em fantoma)info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisporreponame:Repositório Institucional da UFPRinstname:Universidade Federal do Paraná (UFPR)instacron:UFPRinfo:eu-repo/semantics/openAccessORIGINALR - D - CLEVERSON ALEX LEITAO.pdfapplication/pdf10254425https://acervodigital.ufpr.br/bitstream/1884/70714/1/R%20-%20D%20-%20CLEVERSON%20ALEX%20LEITAO.pdf08fe0887d1aa586f64b64f143b9ef288MD51open access1884/707142021-12-30 09:07:12.455open accessoai:acervodigital.ufpr.br:1884/70714Repositório de PublicaçõesPUBhttp://acervodigital.ufpr.br/oai/requestopendoar:3082021-12-30T12:07:12Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)false
dc.title.pt_BR.fl_str_mv Análise dos efeitos da redução da dose sobre a detecção de nódulos pulmonares em tomografias de tórax de baixa e de ultrabaixa dose para rastreamento de câncer de pulmão : (um estudo em fantoma)
title Análise dos efeitos da redução da dose sobre a detecção de nódulos pulmonares em tomografias de tórax de baixa e de ultrabaixa dose para rastreamento de câncer de pulmão : (um estudo em fantoma)
spellingShingle Análise dos efeitos da redução da dose sobre a detecção de nódulos pulmonares em tomografias de tórax de baixa e de ultrabaixa dose para rastreamento de câncer de pulmão : (um estudo em fantoma)
Leitão, Cleverson Alex, 1992-
Tomografia computadorizada
Torax
Pulmões - Doenças
Radiologia
Pulmão - Câncer
Nódulos Pulmonares Múltiplos
title_short Análise dos efeitos da redução da dose sobre a detecção de nódulos pulmonares em tomografias de tórax de baixa e de ultrabaixa dose para rastreamento de câncer de pulmão : (um estudo em fantoma)
title_full Análise dos efeitos da redução da dose sobre a detecção de nódulos pulmonares em tomografias de tórax de baixa e de ultrabaixa dose para rastreamento de câncer de pulmão : (um estudo em fantoma)
title_fullStr Análise dos efeitos da redução da dose sobre a detecção de nódulos pulmonares em tomografias de tórax de baixa e de ultrabaixa dose para rastreamento de câncer de pulmão : (um estudo em fantoma)
title_full_unstemmed Análise dos efeitos da redução da dose sobre a detecção de nódulos pulmonares em tomografias de tórax de baixa e de ultrabaixa dose para rastreamento de câncer de pulmão : (um estudo em fantoma)
title_sort Análise dos efeitos da redução da dose sobre a detecção de nódulos pulmonares em tomografias de tórax de baixa e de ultrabaixa dose para rastreamento de câncer de pulmão : (um estudo em fantoma)
author Leitão, Cleverson Alex, 1992-
author_facet Leitão, Cleverson Alex, 1992-
author_role author
dc.contributor.other.pt_BR.fl_str_mv Jakubiaki, Rosângela Reki
Universidade Federal do Paraná. Setor de Ciências da Saúde. Programa de Pós-Graduação em Medicina Interna e Ciências da Saúde
dc.contributor.author.fl_str_mv Leitão, Cleverson Alex, 1992-
dc.contributor.advisor1.fl_str_mv Escuissato, Dante Luiz
contributor_str_mv Escuissato, Dante Luiz
dc.subject.por.fl_str_mv Tomografia computadorizada
Torax
Pulmões - Doenças
Radiologia
Pulmão - Câncer
Nódulos Pulmonares Múltiplos
topic Tomografia computadorizada
Torax
Pulmões - Doenças
Radiologia
Pulmão - Câncer
Nódulos Pulmonares Múltiplos
description Orientador: Prof. Dr. Dante Luiz Escuissato
publishDate 2020
dc.date.issued.fl_str_mv 2020
dc.date.accessioned.fl_str_mv 2021-12-30T12:07:12Z
dc.date.available.fl_str_mv 2021-12-30T12:07:12Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1884/70714
url https://hdl.handle.net/1884/70714
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 61 p. : il. (algumas color.).
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFPR
instname:Universidade Federal do Paraná (UFPR)
instacron:UFPR
instname_str Universidade Federal do Paraná (UFPR)
instacron_str UFPR
institution UFPR
reponame_str Repositório Institucional da UFPR
collection Repositório Institucional da UFPR
bitstream.url.fl_str_mv https://acervodigital.ufpr.br/bitstream/1884/70714/1/R%20-%20D%20-%20CLEVERSON%20ALEX%20LEITAO.pdf
bitstream.checksum.fl_str_mv 08fe0887d1aa586f64b64f143b9ef288
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)
repository.mail.fl_str_mv
_version_ 1813898706812928000