Desenvolvimento de sensores potenciométricos baseados em filmes de polipirrol para detecção de lactato e cloreto em amostras de fluídos biológicos

Detalhes bibliográficos
Autor(a) principal: Mengarda, Priscilla
Data de Publicação: 2018
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFPR
Texto Completo: https://hdl.handle.net/1884/58935
Resumo: Orientador: Prof. Dr. Luiz Humberto Marcolino Junior
id UFPR_c89243a19573ed6cc737d15cc576b840
oai_identifier_str oai:acervodigital.ufpr.br:1884/58935
network_acronym_str UFPR
network_name_str Repositório Institucional da UFPR
repository_id_str 308
spelling Mengarda, PriscillaBergamini, Márcio FernandoUniversidade Federal do Paraná. Setor de Ciências Exatas. Programa de Pós-Graduação em QuímicaMarcolino Junior, Luiz Humberto2019-03-29T16:47:57Z2019-03-29T16:47:57Z2018https://hdl.handle.net/1884/58935Orientador: Prof. Dr. Luiz Humberto Marcolino JuniorCoorientador: Prof. Dr. Márcio Fernando BergaminiTese (doutorado) - Universidade Federal do Paraná, Setor de Ciências Exatas, Programa de Pós-Graduação em Química. Defesa : Curitiba, 31/08/2018Inclui referências: p.107-119Resumo: Neste trabalho, sensores potenciométricos seletivos a lactato e cloreto baseados em filmes de polipirrol foram apresentados como alternativas promissoras para aplicação em diferentes fluidos biológicos. A determinação dessas duas espécies apresenta importante relevância devido ao lactato ser um indicador de produção de energia pelo sistema glicolítico anaeróbio e tem sido amplamente utilizado para avaliar a capacidade de exercício e monitorar a intensidade de treinamento de atletas, além de ser um biomarcador de algumas doenças. O cloreto é um marcador padrão para o diagnóstico de fibrose cística, uma doença genética sem cura, que requer diagnóstico precoce e métodos precisos de análise. A seletividade dos sensores propostos foi baseada em uma matriz de polipirrol dopada com esses íons em sua estrutura, que ocorre durante a etapa de polimerização galvanostática (1,2 mA cm-2, 720 s). Após a otimização, ambos os sensores seletivos aos íons foram analisados sob condições potenciométricas e mostraram uma ampla faixa linear entre 0,1 e 10,0 mmol L-1 com inclinação de 23,7 ± 0,2 mV déc-1 e limite de detecção (LD) de 78 ??mol L-1 para o sensor de lactato e uma inclinação de 35,0 ± 1,3 mV déc-1 e LD de 85 ??mol L-1 para o sensor de cloreto. Excelente repetibilidade, reprodutibilidade e seletividade também foram obtidas. O primeiro sensor foi aplicado para avaliar os níveis de lactato em amostras de lágrima humana e uma correlação linear com os níveis de lactato em amostras de sangue (R2 = 0,977) foi encontrada. A fim de avaliar os níveis de lactato antes e após a atividade física intensa, foram analisadas amostras de sangue de ratos e amostras de suor humano. Para ambos os fluidos, a variação potencial foi obtida, e em comparação com a análise de lactato no sangue por dispositivo portátil, a resposta em suor humano foi confirmada pelo método proposto. O segundo sensor foi aplicado em amostras de lágrimas e saliva de grupos saudáveis e fibrocísticos para determinar a concentração de cloreto. Os resultados mostraram maior concentração de cloreto na saliva dos voluntários fibrocísticos e podem validar os valores de referência limítrofes e melhorar a análise da resposta. Um estudo comparativo foi realizado entre o método potenciométrico utilizando o sensor proposto e o método coulométrico e apresentou uma correlação significativa para a determinação de cloreto neste fluido (R2 = 0,892). Dessa forma, os sensores potenciométricos desenvolvidos demonstraram uma ferramenta eletroanalítica viável e eficiente para os atuais dispositivos e metodologias comerciais, especialmente para suporte em avaliações de desempenho físico - sensor de lactato - e como um novo método para o diagnóstico de fibrose cística - sensor de cloreto. Palavras-chave: Lactato, cloreto, polipirrol, eletrodos seletivos a íons, sensor, potenciometria, fluidos biológicos.Abstract: In this work, selective potentiometric sensors to lactate and chloride based on polypyrrole films were presented as promising alternatives for application in different biological fluids. The determination of these two species presents important relevance due to lactate is an indicator of energy production by the anaerobic glycolytic system and has been extensively used to evaluate exercise capacity and to monitor the training intensity of athletes, besides being a biomarker of some diseases. Chloride is a standard marker for the diagnosis of cystic fibrosis, a genetic disease without cure, which requires early diagnosis and accurate methods of analysis. The selectivity of proposed sensors was based on a polypyrrole matrix doped with these ions in its structure which occurs during galvanostatic polymerization step (1.2 mA cm-2, 720 s). After optimization, both ion-selective sensors were analyzed under potentiometric conditions and showed a wide linear range between 0.1 and 10.0 mmol L-1 with a slope of 23.7 ± 0.2 mV dec-1 and a limit of detection (LOD) of 78 ??mol L-1 to lactate sensor and a slope of 35.0 ± 1.3 mV dec-1 and a LOD of 85 ??mol L-1 to chloride sensor. Excellent repeatability, reproducibility and selectivity were also achieved. The first sensor was applied to evaluate lactate levels in human tear samples and a linear correlation with lactate levels in blood samples (R2 = 0.977) was found. In order to assess lactate levels before and after intense physical activity, blood samples from rats and human sweat samples were analyzed. For both fluids the potential variation was obtained, and in comparison to the lactate analysis in blood by portable device, the human sweat response was confirmed by the proposed method. The second sensor was performed in tears and saliva samples of healthy and fibrocystic groups to determinate chloride concentration. The results showed a higher chloride concentration in saliva of fibrocystic volunteers and can validate the borderline reference values and improve the analysis of the response. A comparative study between the potentiometric method using the proposed sensor and the coulometric method was performed and showed a significant correlation for the determination of chloride in this fluid (R2 = 0.892). Thus, the developed potentiometric sensors demonstrated a viable and efficient electroanalytical tool to the current commercial devices and methodologies, especially to support in physical performance evaluations - lactate sensor - and as a new method for Cystic Fibrosis diagnosis - chloride sensor. Keywords: Lactate, chloride, polypyrrole, ion-selective electrode, sensor, potentiometry, biological fluids.124 p. : il. (algumas color.).application/pdfDetectoresQuímicaFluidosPolimerizaçãoDesenvolvimento de sensores potenciométricos baseados em filmes de polipirrol para detecção de lactato e cloreto em amostras de fluídos biológicosinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisporreponame:Repositório Institucional da UFPRinstname:Universidade Federal do Paraná (UFPR)instacron:UFPRinfo:eu-repo/semantics/openAccessORIGINALR - T - PRISCILLA MENGARDA.pdfapplication/pdf7048827https://acervodigital.ufpr.br/bitstream/1884/58935/1/R%20-%20T%20-%20PRISCILLA%20MENGARDA.pdf47b68b799225e66c182688c86b6f8a39MD51open access1884/589352019-03-29 13:47:57.224open accessoai:acervodigital.ufpr.br:1884/58935Repositório de PublicaçõesPUBhttp://acervodigital.ufpr.br/oai/requestopendoar:3082019-03-29T16:47:57Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)false
dc.title.pt_BR.fl_str_mv Desenvolvimento de sensores potenciométricos baseados em filmes de polipirrol para detecção de lactato e cloreto em amostras de fluídos biológicos
title Desenvolvimento de sensores potenciométricos baseados em filmes de polipirrol para detecção de lactato e cloreto em amostras de fluídos biológicos
spellingShingle Desenvolvimento de sensores potenciométricos baseados em filmes de polipirrol para detecção de lactato e cloreto em amostras de fluídos biológicos
Mengarda, Priscilla
Detectores
Química
Fluidos
Polimerização
title_short Desenvolvimento de sensores potenciométricos baseados em filmes de polipirrol para detecção de lactato e cloreto em amostras de fluídos biológicos
title_full Desenvolvimento de sensores potenciométricos baseados em filmes de polipirrol para detecção de lactato e cloreto em amostras de fluídos biológicos
title_fullStr Desenvolvimento de sensores potenciométricos baseados em filmes de polipirrol para detecção de lactato e cloreto em amostras de fluídos biológicos
title_full_unstemmed Desenvolvimento de sensores potenciométricos baseados em filmes de polipirrol para detecção de lactato e cloreto em amostras de fluídos biológicos
title_sort Desenvolvimento de sensores potenciométricos baseados em filmes de polipirrol para detecção de lactato e cloreto em amostras de fluídos biológicos
author Mengarda, Priscilla
author_facet Mengarda, Priscilla
author_role author
dc.contributor.other.pt_BR.fl_str_mv Bergamini, Márcio Fernando
Universidade Federal do Paraná. Setor de Ciências Exatas. Programa de Pós-Graduação em Química
dc.contributor.author.fl_str_mv Mengarda, Priscilla
dc.contributor.advisor1.fl_str_mv Marcolino Junior, Luiz Humberto
contributor_str_mv Marcolino Junior, Luiz Humberto
dc.subject.por.fl_str_mv Detectores
Química
Fluidos
Polimerização
topic Detectores
Química
Fluidos
Polimerização
description Orientador: Prof. Dr. Luiz Humberto Marcolino Junior
publishDate 2018
dc.date.issued.fl_str_mv 2018
dc.date.accessioned.fl_str_mv 2019-03-29T16:47:57Z
dc.date.available.fl_str_mv 2019-03-29T16:47:57Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1884/58935
url https://hdl.handle.net/1884/58935
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 124 p. : il. (algumas color.).
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFPR
instname:Universidade Federal do Paraná (UFPR)
instacron:UFPR
instname_str Universidade Federal do Paraná (UFPR)
instacron_str UFPR
institution UFPR
reponame_str Repositório Institucional da UFPR
collection Repositório Institucional da UFPR
bitstream.url.fl_str_mv https://acervodigital.ufpr.br/bitstream/1884/58935/1/R%20-%20T%20-%20PRISCILLA%20MENGARDA.pdf
bitstream.checksum.fl_str_mv 47b68b799225e66c182688c86b6f8a39
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)
repository.mail.fl_str_mv
_version_ 1801860653915308032