Obtenção dos elementos de calibração e certificação de medidores eletrônicos de distância em campo e laboratório

Detalhes bibliográficos
Autor(a) principal: Faggion, Pedro Luis
Data de Publicação: 2001
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFPR
Texto Completo: https://hdl.handle.net/1884/41975
Resumo: Orientador: Silvio Rogério Correia de Freitas
id UFPR_d435f25b9b7cf45bc5fe340ee34a0e0d
oai_identifier_str oai:acervodigital.ufpr.br:1884/41975
network_acronym_str UFPR
network_name_str Repositório Institucional da UFPR
repository_id_str 308
spelling Universidade Federal do Paraná. Setor de Ciências da Terra. Programa de Pós-Graduação em Ciências GeodésicasFreitas, Sílvio Rogério Correia de, 1952-Faggion, Pedro Luis2024-03-25T20:51:23Z2024-03-25T20:51:23Z2001https://hdl.handle.net/1884/41975Orientador: Silvio Rogério Correia de FreitasTese (doutorado) - Universidade Federal do Paraná, Setor de Ciências da Terra, Programa de Pós-Graduação em Ciências GeodésicasResumo: A calibração de Medidores Eletrônicos de Distancia (MED) consiste na determinação do erro de zero, fator de escala e elementos do erro cíclico. Para tal, são necessárias três etapas envolvendo operações de campo e de laboratório. Essas etapas são: determinação do erro de zero (não coincidência entre o centro mecânico e o centro eletrônico do MED); fator de escala (variação na frequência da onda portadora do sinal de medida); elementos do erro cíclico (amplitude e fase). Suas determinações são efetuadas respectivamente por meio de: observações em uma base para calibração em campo, tal como a disponível na UFPR; determinação do fator de escala em laboratório (medindo a frequência da onda portadora) e determinação precisa dos elementos do erro cíclico (amplitude e fase) por observações em uma base em ambiente fechado. O presente trabalho aborda a determinação dos fatores de calibração dos MEDs em laboratório e compara-os com o valor obtido em campo. As principais fontes de erros nos MEDs estão diretamente relacionadas com as variações produzidas pelo envelhecimento e temperatura dos cristais que modulam o sinal utilizado para determinar a distancia entre o emissor e refletor, e também mau uso do equipamento. Com relação a medida da frequência o Professor Harald Schlemmer da Universidade de Darmstadt desenvolveu um fotodetector (EMI C536) cuja finalidade e captar o sinal emitido pelo MED, o qual e analisado por um frequencimetro e por um osciloscópio de alta precisão disponível no (LAIG) e calibrados em laboratório credenciado pelo (INMETRO). O primeiro faz a medida da frequência e o segundo mostra o comportamento da onda. Esses procedimentos permitem a determinação da diferença entre a frequência nominal do equipamento fornecida pelo fabricante, e a frequência obtida em laboratório. Essa diferença afeta o fator de escala. Com relação ao erro cíclico, a calibração em laboratório consiste em comparar deslocamentos dados pelo instrumento que esta sendo calibrado e o mesmo deslocamento medido com um instrumento de alta precisão. Neste trabalho de pesquisa, o instrumento que será considerado como padrão primário e um interferômetro LASER, que nas condições em que esta instalado permite definir deslocamentos com precisão de 10 mp. No campo, são necessárias observações sobre uma base linear. Essa base deve ser medida, em uma primeira fase, com um MED de alta precisão e, posteriormente pelo processo de ajustamento, obtém-se os fatores de calibração dos MEDs de menor precisão ou equivalente. Neste processo e possível determinar também o erro de zero e uma estimativa do erro cíclico. O presente trabalho, além de apresentar a metodologia de calibração de MED com observações de campo e laboratório, faz um estudo da estabilidade de redes geodésicas para definir possíveis variações temporais dos pilares que compõem a base de calibração de campo.Abstract: The calibration of Electronic Distance Meters (EDM) consists in the determination of the zero mistake, scale factor and elements of the cyclical mistake. For such, it is necessary three stages involving field and laboratory operations. These stages are: determination of the zero mistake (no coincidence between the mechanical and electronic center of MED); scale factor (variation in the frequency of the wave bearer of the measure sign); elements of the cyclical mistake (width and phase). These determinations are made respectively through: observations in a field base, just as the available in the extent of UFPR; determination of the scale factor in laboratory (measuring the frequency of the wave bearer); determination the elements of the cyclical mistake (width and phase) through observations in a base in closed atmosphere. The present work approaches the determination of the factors of calibration of MEDs in laboratory and it compares them with the value obtained in field. The principal error source in the EDMs are directly related with the variations produced by ageing and temperature of the crystals that modulate the sign used to determine the distance between the originator and reflector, and also bad use of the equipment. Regarding measure of the frequency the professor Harald Schlemmer of the University of Darmstadt developed a fotodetector (EMI C536) whose purpose is to capture the sign emitted by MED, which is analyzed by a frequency metero and for an oscilloscope of high precision, available in LAIG and gaged at laboratory accredited by INMETRO. The first makes the measure of the frequency and the second shows the behavior of the wave. Those procedures allow the determination of the difference between the nominal frequency of the equipment, supplied by the manufacturer, and the frequency obtained at laboratory. That difference affects the scale factor. Regarding the cyclical mistake, the calibration in laboratory consists of comparing displacements given by the instrument that is being gaged and the same measured displacement with an instrument of high precision. In this research work, the instrument that will be considered as pattern it is an interferometro LASER, that in the conditions that it is installed allows to define displacements accurately of 10 micrometers. In the field, it is necessary observations on a base (as the one of UFPR). That base should be measured, in a first phase with a MED of high precision and later, through adjustment process, be obtained the calibration factors of MEDs of smaller equivalent precision. In this process it is possible also to determine the zero mistake and an estimate of the cyclical mistake. The present work besides presenting the methodology of calibration of MED with field observations and laboratory, makes a study of the geodesic stability of nets to define possible temporary variations of the pillars that compose the calibration field base.130 f. : il., grafs., tabs. ; 30cm.application/pdfDisponível em formato digitalDistanciômetros eletrônicosCalibraçãoDistancias - MediçãoGeodésiaObtenção dos elementos de calibração e certificação de medidores eletrônicos de distância em campo e laboratórioinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisporreponame:Repositório Institucional da UFPRinstname:Universidade Federal do Paraná (UFPR)instacron:UFPRinfo:eu-repo/semantics/openAccessTEXTT - PEDRO LUIS FAGGION.pdf.txtExtracted Texttext/plain172501https://acervodigital.ufpr.br/bitstream/1884/41975/1/T%20-%20PEDRO%20LUIS%20FAGGION.pdf.txt81dfc805411506d27b9efd7eeb23807eMD51open accessORIGINALT - PEDRO LUIS FAGGION.pdfapplication/pdf10422165https://acervodigital.ufpr.br/bitstream/1884/41975/2/T%20-%20PEDRO%20LUIS%20FAGGION.pdfcc9bc68bd7bf73e74d971628aba2cb34MD52open accessTHUMBNAILT - PEDRO LUIS FAGGION.pdf.jpgGenerated Thumbnailimage/jpeg1313https://acervodigital.ufpr.br/bitstream/1884/41975/3/T%20-%20PEDRO%20LUIS%20FAGGION.pdf.jpga0fc5db906f86430def53a79345807a0MD53open access1884/419752024-03-25 17:51:23.622open accessoai:acervodigital.ufpr.br:1884/41975Repositório de PublicaçõesPUBhttp://acervodigital.ufpr.br/oai/requestopendoar:3082024-03-25T20:51:23Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)false
dc.title.pt_BR.fl_str_mv Obtenção dos elementos de calibração e certificação de medidores eletrônicos de distância em campo e laboratório
title Obtenção dos elementos de calibração e certificação de medidores eletrônicos de distância em campo e laboratório
spellingShingle Obtenção dos elementos de calibração e certificação de medidores eletrônicos de distância em campo e laboratório
Faggion, Pedro Luis
Distanciômetros eletrônicos
Calibração
Distancias - Medição
Geodésia
title_short Obtenção dos elementos de calibração e certificação de medidores eletrônicos de distância em campo e laboratório
title_full Obtenção dos elementos de calibração e certificação de medidores eletrônicos de distância em campo e laboratório
title_fullStr Obtenção dos elementos de calibração e certificação de medidores eletrônicos de distância em campo e laboratório
title_full_unstemmed Obtenção dos elementos de calibração e certificação de medidores eletrônicos de distância em campo e laboratório
title_sort Obtenção dos elementos de calibração e certificação de medidores eletrônicos de distância em campo e laboratório
author Faggion, Pedro Luis
author_facet Faggion, Pedro Luis
author_role author
dc.contributor.other.pt_BR.fl_str_mv Universidade Federal do Paraná. Setor de Ciências da Terra. Programa de Pós-Graduação em Ciências Geodésicas
dc.contributor.advisor1.fl_str_mv Freitas, Sílvio Rogério Correia de, 1952-
dc.contributor.author.fl_str_mv Faggion, Pedro Luis
contributor_str_mv Freitas, Sílvio Rogério Correia de, 1952-
dc.subject.por.fl_str_mv Distanciômetros eletrônicos
Calibração
Distancias - Medição
Geodésia
topic Distanciômetros eletrônicos
Calibração
Distancias - Medição
Geodésia
description Orientador: Silvio Rogério Correia de Freitas
publishDate 2001
dc.date.issued.fl_str_mv 2001
dc.date.accessioned.fl_str_mv 2024-03-25T20:51:23Z
dc.date.available.fl_str_mv 2024-03-25T20:51:23Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1884/41975
url https://hdl.handle.net/1884/41975
dc.language.iso.fl_str_mv por
language por
dc.relation.pt_BR.fl_str_mv Disponível em formato digital
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 130 f. : il., grafs., tabs. ; 30cm.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFPR
instname:Universidade Federal do Paraná (UFPR)
instacron:UFPR
instname_str Universidade Federal do Paraná (UFPR)
instacron_str UFPR
institution UFPR
reponame_str Repositório Institucional da UFPR
collection Repositório Institucional da UFPR
bitstream.url.fl_str_mv https://acervodigital.ufpr.br/bitstream/1884/41975/1/T%20-%20PEDRO%20LUIS%20FAGGION.pdf.txt
https://acervodigital.ufpr.br/bitstream/1884/41975/2/T%20-%20PEDRO%20LUIS%20FAGGION.pdf
https://acervodigital.ufpr.br/bitstream/1884/41975/3/T%20-%20PEDRO%20LUIS%20FAGGION.pdf.jpg
bitstream.checksum.fl_str_mv 81dfc805411506d27b9efd7eeb23807e
cc9bc68bd7bf73e74d971628aba2cb34
a0fc5db906f86430def53a79345807a0
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)
repository.mail.fl_str_mv
_version_ 1813898685218553856