Estratégias de co-processamento de lodo séptico em ETEs empregando reatores UASB

Detalhes bibliográficos
Autor(a) principal: Samways, Guilherme, 1978-
Data de Publicação: 2015
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFPR
Texto Completo: https://hdl.handle.net/1884/64779
Resumo: Orientador: Prof. Dr. Miguel Mansur Aisse
id UFPR_d45d5c0185ac3af8cabb69c48d675f7b
oai_identifier_str oai:acervodigital.ufpr.br:1884/64779
network_acronym_str UFPR
network_name_str Repositório Institucional da UFPR
repository_id_str 308
spelling Samways, Guilherme, 1978-Universidade Federal do Paraná. Setor de Tecnologia. Programa de Pós-Graduação em Engenharia de Recursos Hídricos e AmbientalAisse, Miguel Mansur, 1953-2021-06-17T21:23:35Z2021-06-17T21:23:35Z2015https://hdl.handle.net/1884/64779Orientador: Prof. Dr. Miguel Mansur AisseTese (doutorado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Engenharia de Recursos Hídricos e Ambiental. Defesa : Curitiba, 02/09/2015Inclui referências: p. 152-167Resumo: Sistemas individuais de tratamento de esgoto sanitário, que empregam tanques sépticos são alternativas importantes, principalmente se associadas a sistemas de esgotamento sanitário convencional. Procedimentos inadequados na operação de tanques sépticos para tratamento de esgotos, sobretudo na frequência de retirada do lodo, transporte e destinação final, são pontos negativos no uso dessa tecnologia. Este estudo buscou definir algumas estratégias para o pré-tratamento do lodo séptico antes do co-processamento em Estações de Tratamento de Esgoto (ETEs) que empregam sistemas anaeróbios. O trabalho incluiu a pré-hidrólise térmica, a aplicação do lodo séptico pré-hidrolisado em digestores, comparou a degradabilidade do lodo séptico e do lodo séptico hidrolisado, propôs uma definição de um sistema de recepção, pré-tratamento e equalização do lodo séptico em ETEs e verificou a capacidade de recepção de lodo em algumas ETEs paranaenses. Como resultados, o lodo séptico pré-hidrolisado termicamente por 1 hora, a 60oC apresentou resultados positivos, porém inferiores aos encontrados em literatura na hidrólise de outros tipos de matéria orgânica. Houve um aumento da ordem de 1,5x na DQO em função da desintegração térmica da fração orgânica do lodo anaeróbio, um aumento na relação alcalinidade/acidez na ordem de 72%. Na digestão do lodo pré-hidrolisado em reator de bancada foi encontrada uma eficiência na remoção de DQO da ordem de 57% para uma aplicação de Carga Orgânica Volumétrica (COV) 2 kgSTV. m-3d-1, 43% para COV 4 kgSTV. m-3d-1. A eficiência de remoção da DBO na primeira carga foi de 58% para COV 2 kgSTV. m-3d-1, e de 87% para COV 4 kgSTV. m-3d-1. A eficiência na remoção de Sólidos Totais foi de 48% para COV 2 kgSTV. m- 3d-1 e de 50% para COV 4 kgSTV. m-3d-1. Foi encontrado uma boa degradabilidade do lodo séptico e lodo séptico, hidrolisado em temperatura ambiente e controlada a 35oC, entre as faixas de 0,65 a 0,80 kgSST.m-3.d-1. Foi sugerida uma Central de Recepção de Lodo de Tanques Sépticos (CRLTS), localizado a montante das ETEs, sistematizando as informações de propostas encontradas na literatura. Verificou-se a potencialidade de recepção de lodo séptico em todos os municípios paranaenses que operam ETEs com tecnologia anaeróbia, sendo todas aptas em receber o lodo para cargas adicionais de até 0,71 kgDQO.m-3.d-1. Palavras-chave: biodegradabilidade anaeróbia do lodo; Central de Recepção de Lodo de Tanques Sépticos (CRLTS); estações de tratamento de esgoto, hidrólise térmica do lodo; lodo séptico. ,Abstract: On-site sewage treatment systems, employing septic tanks are important alternative, especially if associated with conventional sewage systems. Inadequate procedures in the operation of septic tanks, especially in sludge removal frequency, transportation and disposal are drawbacks in using this technology. This study sought to define some strategies for septic sludge pre-treated before co-processing with sewage in Wastewater Treatment Plants (WWTPs) that employ anaerobic systems. This work included thermal pre-hydrolysis, the application of the thermal pre-hydrolysis sludge in digesters, thermal pre-hydrolysis septic sludge degradability comparison investigation with raw septic sludge, proposed a definition of a system for receive, equalize and pre-treat septic sludge in WWTPs, and at last, found the sludge reception capacity in some Paraná WWTPs. As a result, the pre-septic sludge thermally hydrolysed for 1 hour, at 60 °C, showed positive results, but lower than those found in the literature for hydrolysis of other types of organic material. There was a 1.5x increase in COD in thermal disintegration of the organic fraction of the anaerobic sludge, an increase of 72% in alkalinity/acidity relation. The digestion in bench reactor of the hydrolysed sludge has an efficiency of COD removal of 57% for a Volumetric Organic Load (VOL) 2 kgTVS. m-3d-1 application, 43% for 4 kgTVS. m- 3d-1. The BOD removal efficiency was 58% for 2 kgTVS. m-3d-1and 87% for 4 kgTVS. m-3d-1. The removal efficiency of total solids was 48% for 2 kgTVS. m-3d-1 and 50% for VOL kgTVS. m-3d-1. A good degradability of septic sludge and hydrolyzed septic sludge at room and controlled temperature at 35 °C was found between 0.65 to 0.80 kgTSS.m-3.d-1. One Sludge Reception Center (CRLTS), located upstream of the WWTPs, was proposal, systematizing information found in the literature. All Paraná municipal districts operating with anaerobic wastewater treatment technology are able to receive sludge loads up to 0.71 kgCOD.m-3.d-1. Keywords: sludge anaerobic biodegradability; Sludge Reception Center (CRLTS); Wastewater Treatment Plants, thermal hydrolysis of sludge; septic sludge.1 arquivo (172 p.) : il. (algumas color.).application/pdfLodoDigestão anaerobicaEsgotosFossas sépticasRecursos HídricosEstratégias de co-processamento de lodo séptico em ETEs empregando reatores UASBinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisporreponame:Repositório Institucional da UFPRinstname:Universidade Federal do Paraná (UFPR)instacron:UFPRinfo:eu-repo/semantics/openAccessORIGINALR - T - GUILHERME SAMWAYS.pdfapplication/pdf7859622https://acervodigital.ufpr.br/bitstream/1884/64779/1/R%20-%20T%20-%20GUILHERME%20SAMWAYS.pdf72e053819ed4e6613858e0f9fb8b1804MD51open access1884/647792021-06-17 18:23:36.072open accessoai:acervodigital.ufpr.br:1884/64779Repositório de PublicaçõesPUBhttp://acervodigital.ufpr.br/oai/requestopendoar:3082021-06-17T21:23:36Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)false
dc.title.pt_BR.fl_str_mv Estratégias de co-processamento de lodo séptico em ETEs empregando reatores UASB
title Estratégias de co-processamento de lodo séptico em ETEs empregando reatores UASB
spellingShingle Estratégias de co-processamento de lodo séptico em ETEs empregando reatores UASB
Samways, Guilherme, 1978-
Lodo
Digestão anaerobica
Esgotos
Fossas sépticas
Recursos Hídricos
title_short Estratégias de co-processamento de lodo séptico em ETEs empregando reatores UASB
title_full Estratégias de co-processamento de lodo séptico em ETEs empregando reatores UASB
title_fullStr Estratégias de co-processamento de lodo séptico em ETEs empregando reatores UASB
title_full_unstemmed Estratégias de co-processamento de lodo séptico em ETEs empregando reatores UASB
title_sort Estratégias de co-processamento de lodo séptico em ETEs empregando reatores UASB
author Samways, Guilherme, 1978-
author_facet Samways, Guilherme, 1978-
author_role author
dc.contributor.other.pt_BR.fl_str_mv Universidade Federal do Paraná. Setor de Tecnologia. Programa de Pós-Graduação em Engenharia de Recursos Hídricos e Ambiental
dc.contributor.author.fl_str_mv Samways, Guilherme, 1978-
dc.contributor.advisor1.fl_str_mv Aisse, Miguel Mansur, 1953-
contributor_str_mv Aisse, Miguel Mansur, 1953-
dc.subject.por.fl_str_mv Lodo
Digestão anaerobica
Esgotos
Fossas sépticas
Recursos Hídricos
topic Lodo
Digestão anaerobica
Esgotos
Fossas sépticas
Recursos Hídricos
description Orientador: Prof. Dr. Miguel Mansur Aisse
publishDate 2015
dc.date.issued.fl_str_mv 2015
dc.date.accessioned.fl_str_mv 2021-06-17T21:23:35Z
dc.date.available.fl_str_mv 2021-06-17T21:23:35Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1884/64779
url https://hdl.handle.net/1884/64779
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 1 arquivo (172 p.) : il. (algumas color.).
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFPR
instname:Universidade Federal do Paraná (UFPR)
instacron:UFPR
instname_str Universidade Federal do Paraná (UFPR)
instacron_str UFPR
institution UFPR
reponame_str Repositório Institucional da UFPR
collection Repositório Institucional da UFPR
bitstream.url.fl_str_mv https://acervodigital.ufpr.br/bitstream/1884/64779/1/R%20-%20T%20-%20GUILHERME%20SAMWAYS.pdf
bitstream.checksum.fl_str_mv 72e053819ed4e6613858e0f9fb8b1804
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)
repository.mail.fl_str_mv
_version_ 1813898759131627520