Avaliação comparativa da taxa de oclusão da veia safena magna submetida a termoablação com laser endovenoso 1470 NM, utilizando alta e baixa potência
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Tipo de documento: | Tese |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFPR |
Texto Completo: | http://hdl.handle.net/1884/40871 |
Resumo: | Orientador: Prof. Dr. Jorge Rufino Ribas Timi |
id |
UFPR_d84fd62a458f009a8a00bb81b5271646 |
---|---|
oai_identifier_str |
oai:acervodigital.ufpr.br:1884/40871 |
network_acronym_str |
UFPR |
network_name_str |
Repositório Institucional da UFPR |
repository_id_str |
308 |
spelling |
Nejm Junior, Carlos SemeMatias, Jorge Eduardo FoutoUniversidade Federal do Paraná. Setor de Ciências da Saúde. Programa de Pós-Graduação em Clínica CirúrgicaTimi, Jorge Rufino Ribas2016-03-21T16:58:05Z2016-03-21T16:58:05Z2015http://hdl.handle.net/1884/40871Orientador: Prof. Dr. Jorge Rufino Ribas TimiCo-orientador: Prof. Dr. Jorge Eduardo Fouto MatiasTese (doutorado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Clínica Cirúrgica. Defesa: Curitiba, 19/06/2015Inclui referências : f.69-78Área de concentração : Clínica cirúrgicaResumo: As pesquisas em clínica cirúrgica tendem a buscar utilização de tecnologias menos invasivas com menor comorbidade para os pacientes. Na cirurgia de varizes dos membros inferiores não é diferente. A termoablação com endolaser venoso (EVLT) representa a principal tecnologia com este propósito na cirurgia vascular venosa. Diversos são os estudos tentando demonstrar qual a melhor técnica de se realizar a termoablação com o EVLT. Objetivo: determinar a existência de diferença ou não na taxa de oclusão ao ecodoppler colorido da veia safena magna submetida a termoablação com laser endovenoso 1470 nm utilizando alta (15w) e baixa (7w) potência ( objetivo primário) bem como as complicações relacionadas ao procedimento ( objetivo secundário). Material e Método: estudo prospectivo e randomizado ulitlizando sessenta veias safenas magna. Os pacientes, após apresentarem indicação de cirurgia de varizes, preencherem os critérios de inclusão, e não apresentarem critérios de exclusão, foram divididos em dois grupos, baixa (7 W) e alta (15) potência. Os pacientes foram randomizados por data de nascimento. Foi realizada termoablação utilizando laser de diodo 1470 nm. Apenas o pesquisador tinha ciência de quais pacientes usaram alta ou baixa potência, deste modo os pacientes e o médico ecografista vascular não tinham este conhecimento. Foram realizados exames de controle com 3-5 dias, 30 dias e 180 dias de pós-operatório. Foi avaliada a taxa de oclusão ao ecodoppler e as complicações inerentes ao procedimento nos dois grupos. As características clínicas avaliadas foram: trombose venosa profunda (TVP), flebite, parestesia, equimose, dor, quantidade de analgésicos, escore de serveridade clínica, embolia pulmonar, queimadura de pele. Para comparação dos grupos definidos pela potência, em relação a variáveis quantitativas, foram considerados os testes t de Student para amostras independentes e o teste não paramétrico de Mann- Whitney. Para avaliação da associação entre variáveis qualitativas foram considerados os testes Qui-Quadrado e Exato de Fisher. Para comparação dos diferentes momentos de avaliação, em relação ao escore de gravidade foi considerado o teste não paramétrico de Friedman. A avaliação da condição de normalidade das variáveis foi realizada considerando-se o teste de Jarque-Béra. Valores de p menores do que 0,05 indicaram significância estatística. Resultados: os grupos foram homogêneos em todos os critérios avaliados exceto o IMC. O grupo de baixa potência apresentou taxa de recanalização maior, com menor incidência de complicações. Porém, não houve diferença estatística entre os grupos. Conclusão: a utilização de baixa (7w) ou alta (15) potência são equivalentes na efetividade (objetivo primário) e apresentaram semelhantes taxas de complicações (objetivo secundário) e escores de severidade clínica. Descritores: varizes de membros inferiores, cirurgia, termoablação, laserAbstract: Research in surgical clinic tend to seek the use of less invasive technologies with lower comorbidity for patients. In the surgery of varicose veins is no different. The thermal ablation with venous endolaser (TAVE) is the key technology for this purpose in the venous vascular surgery. There are several studies trying to demonstrate the best technique of performing thermal ablation with TAVE. Objective: To determine if there is a difference or not in occlusion rate of the great saphenous vein submitted to thermal ablation with endovenous laser 1470 nm using high (15w) and low (7w) power (primary objective) using color Doppler ultrasound ; and the procedure-related complications (secondary objective). Material and Method: A prospective randomized study using sixty great saphenous veins. The patients, after being selected for varicose vein surgery, met the criteria for inclusion and having no exclusion criteria present were divided into two groups, low (7 W) and high (15) power. Patients were randomized by date of birth. Thermal ablation was performed using 1470 nm laser diode. Only the researcher was aware of which patients used high or low power, so patients and vascular medical sonographer did not have this knowledge. Control tests were performed 3-5 days, 30 days and 180 days after surgery. The occlusion rate was assessed with Doppler ultrasound and complications related to the procedure in both groups. The clinical signs evaluated were deep vein thrombosis (DVT), phlebitis, numbness, bruising, pain, amount of analgesia, clinical severety score, pulmonary embolism, and skin burn. To compare the groups defined by power, for quantitative variables, we considered the Student t test for independent samples and the nonparametric test Mann-Whitney. To evaluate the association between qualitative variables the Chi-square and Fisher exact tests were considered To compare the different time points, compared to the severity score the nonparametric Friedman was considered. The evaluation of the variables normality condition was performed considering the Jarque-Bera test. P values less than 0.05 were considered statistically significant. Results: The groups were homogeneous in all criteria evaluated except BMI. The low-power group showed higher recanalization rate with a lower incidence of complications. However, there was no statistical difference between the groups. Conclusion: The use of low (7w) or high (15) power are equivalent in effectiveness (primary objective) and had similar complication rates (secondary objective) and clinical severity scores. Keywords: varicose veins, surgery, thermal ablation, laser.105 f. : il. algumas color., tabs.application/pdfDisponível em formato digitalCirurgiaVarizesVeia safenaLasersCirurgiaAvaliação comparativa da taxa de oclusão da veia safena magna submetida a termoablação com laser endovenoso 1470 NM, utilizando alta e baixa potênciainfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisporreponame:Repositório Institucional da UFPRinstname:Universidade Federal do Paraná (UFPR)instacron:UFPRinfo:eu-repo/semantics/openAccessORIGINALR - T - CARLOS SEME NEJM JUNIOR.pdfapplication/pdf167605083https://acervodigital.ufpr.br/bitstream/1884/40871/1/R%20-%20T%20-%20CARLOS%20SEME%20NEJM%20JUNIOR.pdf4d33a6560183abe2fa3710165f91a4b2MD51open accessTEXTR - T - CARLOS SEME NEJM JUNIOR.pdf.txtExtracted Texttext/plain104517https://acervodigital.ufpr.br/bitstream/1884/40871/2/R%20-%20T%20-%20CARLOS%20SEME%20NEJM%20JUNIOR.pdf.txtdcb48bb1de98bb9b1246b262f0c4b092MD52open accessTHUMBNAILR - T - CARLOS SEME NEJM JUNIOR.pdf.jpgR - T - CARLOS SEME NEJM JUNIOR.pdf.jpgGenerated Thumbnailimage/jpeg1247https://acervodigital.ufpr.br/bitstream/1884/40871/3/R%20-%20T%20-%20CARLOS%20SEME%20NEJM%20JUNIOR.pdf.jpgaff4faac9f9da0a4d2f99b07180aaeeaMD53open access1884/408712016-04-07 06:35:52.629open accessoai:acervodigital.ufpr.br:1884/40871Repositório de PublicaçõesPUBhttp://acervodigital.ufpr.br/oai/requestopendoar:3082016-04-07T09:35:52Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)false |
dc.title.none.fl_str_mv |
Avaliação comparativa da taxa de oclusão da veia safena magna submetida a termoablação com laser endovenoso 1470 NM, utilizando alta e baixa potência |
title |
Avaliação comparativa da taxa de oclusão da veia safena magna submetida a termoablação com laser endovenoso 1470 NM, utilizando alta e baixa potência |
spellingShingle |
Avaliação comparativa da taxa de oclusão da veia safena magna submetida a termoablação com laser endovenoso 1470 NM, utilizando alta e baixa potência Nejm Junior, Carlos Seme Cirurgia Varizes Veia safena Lasers Cirurgia |
title_short |
Avaliação comparativa da taxa de oclusão da veia safena magna submetida a termoablação com laser endovenoso 1470 NM, utilizando alta e baixa potência |
title_full |
Avaliação comparativa da taxa de oclusão da veia safena magna submetida a termoablação com laser endovenoso 1470 NM, utilizando alta e baixa potência |
title_fullStr |
Avaliação comparativa da taxa de oclusão da veia safena magna submetida a termoablação com laser endovenoso 1470 NM, utilizando alta e baixa potência |
title_full_unstemmed |
Avaliação comparativa da taxa de oclusão da veia safena magna submetida a termoablação com laser endovenoso 1470 NM, utilizando alta e baixa potência |
title_sort |
Avaliação comparativa da taxa de oclusão da veia safena magna submetida a termoablação com laser endovenoso 1470 NM, utilizando alta e baixa potência |
author |
Nejm Junior, Carlos Seme |
author_facet |
Nejm Junior, Carlos Seme |
author_role |
author |
dc.contributor.other.none.fl_str_mv |
Matias, Jorge Eduardo Fouto Universidade Federal do Paraná. Setor de Ciências da Saúde. Programa de Pós-Graduação em Clínica Cirúrgica |
dc.contributor.author.fl_str_mv |
Nejm Junior, Carlos Seme |
dc.contributor.advisor1.fl_str_mv |
Timi, Jorge Rufino Ribas |
contributor_str_mv |
Timi, Jorge Rufino Ribas |
dc.subject.por.fl_str_mv |
Cirurgia Varizes Veia safena Lasers Cirurgia |
topic |
Cirurgia Varizes Veia safena Lasers Cirurgia |
description |
Orientador: Prof. Dr. Jorge Rufino Ribas Timi |
publishDate |
2015 |
dc.date.issued.fl_str_mv |
2015 |
dc.date.accessioned.fl_str_mv |
2016-03-21T16:58:05Z |
dc.date.available.fl_str_mv |
2016-03-21T16:58:05Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
format |
doctoralThesis |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1884/40871 |
url |
http://hdl.handle.net/1884/40871 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
Disponível em formato digital |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
105 f. : il. algumas color., tabs. application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFPR instname:Universidade Federal do Paraná (UFPR) instacron:UFPR |
instname_str |
Universidade Federal do Paraná (UFPR) |
instacron_str |
UFPR |
institution |
UFPR |
reponame_str |
Repositório Institucional da UFPR |
collection |
Repositório Institucional da UFPR |
bitstream.url.fl_str_mv |
https://acervodigital.ufpr.br/bitstream/1884/40871/1/R%20-%20T%20-%20CARLOS%20SEME%20NEJM%20JUNIOR.pdf https://acervodigital.ufpr.br/bitstream/1884/40871/2/R%20-%20T%20-%20CARLOS%20SEME%20NEJM%20JUNIOR.pdf.txt https://acervodigital.ufpr.br/bitstream/1884/40871/3/R%20-%20T%20-%20CARLOS%20SEME%20NEJM%20JUNIOR.pdf.jpg |
bitstream.checksum.fl_str_mv |
4d33a6560183abe2fa3710165f91a4b2 dcb48bb1de98bb9b1246b262f0c4b092 aff4faac9f9da0a4d2f99b07180aaeea |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR) |
repository.mail.fl_str_mv |
|
_version_ |
1813898920830435328 |