Predição do limiar de lactato em atletas de endurance a partir da curva de esforço percebido durante teste progressivo

Detalhes bibliográficos
Autor(a) principal: Ferreira, Guilherme Assunção
Data de Publicação: 2015
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFPR
Texto Completo: http://hdl.handle.net/1884/37895
Resumo: Orientador : Prof. Dr. Raul Osiecki
id UFPR_fe413c068dbb789cd6944ec6cd9b0927
oai_identifier_str oai:acervodigital.ufpr.br:1884/37895
network_acronym_str UFPR
network_name_str Repositório Institucional da UFPR
repository_id_str 308
spelling Ferreira, Guilherme AssunçãoUniversidade Federal do Paraná. Setor de Ciências Biológicas. Programa de Pós-Graduação em Educação FísicaOsiecki, Raul, 1965-2018-03-27T12:38:09Z2018-03-27T12:38:09Z2015http://hdl.handle.net/1884/37895Orientador : Prof. Dr. Raul OsieckiDissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências Biológicas, Programa de Pós-Graduação em Educação Física. Defesa: Curitiba, 23/02/2015Inclui referênciasÁrea de concentração: Exercício e esporteResumo: A identificação do limiar de lactato (LL) em teste progressivo (TP) é comumente empregado para a discriminação da aptidão aeróbia e verificação de efeitos de treinamento. Alternativamente, a percepção subjetiva de esforço (PSE) possibilita a identificação de um limiar de PSE (LPSE) em não atletas, restando dúvidas sobre sua intensidade de ocorrência e seu uso na identificação do LL em atletas. O objetivo deste estudo foi verificar intensidade de ocorrência do LPSE e sua associação com o LL em atletas de endurance. Vinte e quatro sujeitos (13 atletas de endurance (GA) e 11 indivíduos ativos fisicamente - grupo não atletas (NA)) realizaram um TP em ciclo ergômetro, à 80 rpm, carga inicial de 110 W durante cinco minutos, estágios de três minutos e incrementos de 47 W. O LL foi identificado por três diferentes critérios: 1) - intensidade do exercício que precede um aumento na concentração de lactato em 1 mmol.l-1 sobre os valores de repouso (LL1mmol); 2) - intensidade do exercício correspondente à concentração fixa de 4 mmol.l-1 (LL4mmol); e 3) - Dmax da diferença entre um ajuste polinomial de 3° ordem da curva formada pela relação Lactato/carga e um ajuste linear ligando os extremos da curva (LLDmax). O LPSE foi identificado no Dmax da diferença entre um ajuste polinomial de 3° ordem da curva formada pela relação PSE/carga e um ajuste linear ligando os extremos da curva (LPSE). No GA a potência máxima (Wmax) e a potência de ocorrência dos Limiares (i.e. LPSE, LL1mmol, LLDmax e LL4mmol) foram significativamente superiores ao valores obtidos para o NA (p < 0,05). Similarmente, o mesmo foi observado para a %Wmax de ocorrência do LL1mmol (p < 0,05) e a FC (bpm) e %FCpico de ocorrência do LL1mmol e LL4mmol (p < 0,05). O LPSE no GA foi encontrado em intensidade similares ao LL1mmol e, em menores intensidade que LLDmax e LL4mmol (p < 0,05). Foi encontrado um pequeno viés entre a potência mensurada no LPSE e a potência mensurada no LL1mmol ( > 5%) e um amplo viés entre a potência mensurada no LPSE e a potência mensurada no LLDmax e LL4mmol ( > 5%). Para o NA, o LPSE foi encontrando em maiores intensidades que o LL1mmol (p < 0,05), mas em intensidades similares ao LLDmax e LL4mmol (p > 0,05). Embora fosse observado um amplo viés entre a potência mensurada no LPSE e a potência mensurada no LLDmax e LL4mmol (> 5%). Estes resultados sugerem que o LPSE pode predizer alternativamente o LL identificado na intensidade do exercício que precede um aumento na concentração de lactato em 1 mmol.l-1 sobre os valores de repouso em atletas, mas deve ser utilizado com cautela para a identificação do LLDmax, uma vez que o LPSE tende a subestimar o LLDmax em atletas e não atletas. Palavras Chaves: Limiar de percepção subjetiva de esforço; Atletas; Limiares de transição fisiológica; Avaliação de atletas; Desempenho.Abstract: The lactate threshold (LT) identified in progressive test has been widely used to discriminate aerobic fitness. Alternatively, the rate of perceived exertion (RPE) present a threshold (RPET) in non-athletes, but it is unclear if this possible to determinate LT in athletes. The aim of this study was to verify the occurrence of RPET and its association with LT in endurance athletes. Twenty four subjects (13 endurance athletes - athlete group (AG) with age = 35.9 ± 9.3 years; body mass = 72.4 ± 5.4 kg; height = 176.0 ± 4.9 cm and body fat = 9.3 ± 3.2 % and 11 physically active individuals - non-athlete group (NA) with age = 28.5 ± 10.1 years; body mass = 88.8 ± 11.0 kg, height = 179, 6 ± 7.2 cm and body fat = 14.5 ± 6.2 %) performed an incremental test on a cycle ergometer, at 80 rpm, with initial load of 110 W, and increments of 47 W each 3 min. until voluntary exhaustion or inability to maintain the specified pace. The LT was identified by three different criteria: 1) - intensity of exercise that precedes an increase in lactate concentration in 1 mmol.l-1 on resting values (LT1mmol); 2) - intensity of the corresponding fixed blood lactate concentration of 4 mmol.l-1 (LT4mmol); and 3) - Dmax of the difference between a polynomial fit to the 3rd order of the curve formed by lactate / power output and a linear fitting curve connecting the end (LTDmax). The RPET was identified by Dmax of the difference between a polynomial fit to the 3rd order curve formed by the RPE/power output relationship and a linear fitting curve connecting the end (RPET). For GA the maximum power output (Wmax) and power output of occurrence of thresholds (I.e. RPET, LT1mmol, LTDmax and LT4mmol) were significantly higher than the values obtained for the NA (P < 0.05). Similarly, the same was observed for the %Wmax at LT1mmol (p < 0.05) and HR and %HRpeak at LT1mmol and LT4mmol (p < 0.05). The RPET in GA was found in similar intensity to LT1mmol (p > 0.05), and lower intensity that LTDmax and LT4mmol (p < 0.05). A small bias was found between the power output measured in RPET and LT1mmol (< 5%) and a large bias was found between the power output of measured RPET and other thresholds (LTDmax and LL4mmol) (> 5%). For the NA the REPT was found in higher intensity that LT1mmol (p < 0.05) and in similar intensities that LTDmax and LL4mmol (p > 0.05). Although a large bias was found between the power output measured at RPET and thresholds (LTDmax and LL4mmol). These results suggest that RPET may alternatively predict the LT identified in exercise intensity above an increase in lactate concentration of 1 mmol.l-1 over basal levels in athletes, however the RPET should to be utilized with precaution to predict to LTDmax, since RPET tends to underestimate the LTDmax in athletes and non-athletes. Key words: Perception exertion threshold; athletes; Physiological transition threshold; Athletes evaluation; Performance.81p. : tabs., grafs.application/pdfDisponível em formato digitalEducação FísicaPercepcao subjetiva de esforcoAtletasLimiar de lactatoTeste progressivoPredição do limiar de lactato em atletas de endurance a partir da curva de esforço percebido durante teste progressivoinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisporreponame:Repositório Institucional da UFPRinstname:Universidade Federal do Paraná (UFPR)instacron:UFPRinfo:eu-repo/semantics/openAccessTHUMBNAILR - D - GUILHERME ASSUNCAO FERREIRA.pdf.jpgGenerated Thumbnailimage/jpeg1676https://acervodigital.ufpr.br/bitstream/1884/37895/1/R%20-%20D%20-%20GUILHERME%20ASSUNCAO%20FERREIRA.pdf.jpg6a59d5bae886d5813685abf8be72f2b6MD51open accessTEXTR - D - GUILHERME ASSUNCAO FERREIRA.pdf.txtExtracted Texttext/plain130817https://acervodigital.ufpr.br/bitstream/1884/37895/2/R%20-%20D%20-%20GUILHERME%20ASSUNCAO%20FERREIRA.pdf.txt12ee11acf7f3c9668e31130e129d5496MD52open accessORIGINALR - D - GUILHERME ASSUNCAO FERREIRA.pdfapplication/pdf1754406https://acervodigital.ufpr.br/bitstream/1884/37895/3/R%20-%20D%20-%20GUILHERME%20ASSUNCAO%20FERREIRA.pdfb8fb442cc2b26f489752002a2ac7376cMD53open access1884/378952018-03-27 09:38:09.27open accessoai:acervodigital.ufpr.br:1884/37895Repositório de PublicaçõesPUBhttp://acervodigital.ufpr.br/oai/requestopendoar:3082018-03-27T12:38:09Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)false
dc.title.pt_BR.fl_str_mv Predição do limiar de lactato em atletas de endurance a partir da curva de esforço percebido durante teste progressivo
title Predição do limiar de lactato em atletas de endurance a partir da curva de esforço percebido durante teste progressivo
spellingShingle Predição do limiar de lactato em atletas de endurance a partir da curva de esforço percebido durante teste progressivo
Ferreira, Guilherme Assunção
Educação Física
Percepcao subjetiva de esforco
Atletas
Limiar de lactato
Teste progressivo
title_short Predição do limiar de lactato em atletas de endurance a partir da curva de esforço percebido durante teste progressivo
title_full Predição do limiar de lactato em atletas de endurance a partir da curva de esforço percebido durante teste progressivo
title_fullStr Predição do limiar de lactato em atletas de endurance a partir da curva de esforço percebido durante teste progressivo
title_full_unstemmed Predição do limiar de lactato em atletas de endurance a partir da curva de esforço percebido durante teste progressivo
title_sort Predição do limiar de lactato em atletas de endurance a partir da curva de esforço percebido durante teste progressivo
author Ferreira, Guilherme Assunção
author_facet Ferreira, Guilherme Assunção
author_role author
dc.contributor.other.pt_BR.fl_str_mv Universidade Federal do Paraná. Setor de Ciências Biológicas. Programa de Pós-Graduação em Educação Física
dc.contributor.author.fl_str_mv Ferreira, Guilherme Assunção
dc.contributor.advisor1.fl_str_mv Osiecki, Raul, 1965-
contributor_str_mv Osiecki, Raul, 1965-
dc.subject.por.fl_str_mv Educação Física
Percepcao subjetiva de esforco
Atletas
Limiar de lactato
Teste progressivo
topic Educação Física
Percepcao subjetiva de esforco
Atletas
Limiar de lactato
Teste progressivo
description Orientador : Prof. Dr. Raul Osiecki
publishDate 2015
dc.date.issued.fl_str_mv 2015
dc.date.accessioned.fl_str_mv 2018-03-27T12:38:09Z
dc.date.available.fl_str_mv 2018-03-27T12:38:09Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1884/37895
url http://hdl.handle.net/1884/37895
dc.language.iso.fl_str_mv por
language por
dc.relation.pt_BR.fl_str_mv Disponível em formato digital
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 81p. : tabs., grafs.
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFPR
instname:Universidade Federal do Paraná (UFPR)
instacron:UFPR
instname_str Universidade Federal do Paraná (UFPR)
instacron_str UFPR
institution UFPR
reponame_str Repositório Institucional da UFPR
collection Repositório Institucional da UFPR
bitstream.url.fl_str_mv https://acervodigital.ufpr.br/bitstream/1884/37895/1/R%20-%20D%20-%20GUILHERME%20ASSUNCAO%20FERREIRA.pdf.jpg
https://acervodigital.ufpr.br/bitstream/1884/37895/2/R%20-%20D%20-%20GUILHERME%20ASSUNCAO%20FERREIRA.pdf.txt
https://acervodigital.ufpr.br/bitstream/1884/37895/3/R%20-%20D%20-%20GUILHERME%20ASSUNCAO%20FERREIRA.pdf
bitstream.checksum.fl_str_mv 6a59d5bae886d5813685abf8be72f2b6
12ee11acf7f3c9668e31130e129d5496
b8fb442cc2b26f489752002a2ac7376c
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFPR - Universidade Federal do Paraná (UFPR)
repository.mail.fl_str_mv
_version_ 1813898860096913408