Suino como modelo experimental na pesquisa biomédica: valores fisiológicos normais

Detalhes bibliográficos
Autor(a) principal: Gianotti, Giordano
Data de Publicação: 2010
Outros Autores: Beheregaray, Wanessa Kruger, Bianchi, Simone Passos, Mombachi, Verônica Santos, Carregaro, Adriano Bonfim, Contesini, Emerson Antônio
Tipo de documento: Artigo
Idioma: por
Título da fonte: Repositório Institucional da UFRGS
Texto Completo: http://hdl.handle.net/10183/29189
Resumo: Background: The use of animals in biomedical research is of great importance. It is fundamental for the development and improvement of new practices and technologies. The selection of the species must take into consideration the practicality of handling and the suitability for the experiment, and it must have low operational costs. Swine are important as an experimental model in several experiment areas, because the functionality of many of their organic systems is developed similarly as it is in humans. Swine are animals that become easily stressed. For that reason, their conditioning is necessary to allow the obtainment of data that is closer to normal parameters. This study aims at reporting the physiological values obtained from awake swine, under normal conditions and minimum stress. Materials, Methods & Results: The animals were maintained under ideal environmental conditions, and they were always handled and conditioned by the same persons. Twenty crossbred swine were evaluated, aged between 60 and 90 days and with a body mass ranging between 17 and 25 kg. The parameters considered were cardiac frequency (FC), hemoglobin oxygen saturation (pulse oxymetry – SPO2), respiratory frequency (fR), end tidal carbon dioxide (ETCO2), systolic (PAM), diastolic (PAD) and mean (PAM) arterial pressure and arterial blood gas values – pH, arterial pressure of CO2 (PACO2), arterial pressure of O2 (PAO2), total CO2 (TCO2), base excess (EB), bicarbonate (HCO3) and O2 saturation (SATO2). The experiment was developed in compliance with the Standards of Animal Ethics and Welfare recommended by the National Council on the Control of Animal Experiments and with Law 11.794 of October 2008, being further approved by the Ethics Committee of the Hospital de Clínicas de Porto Alegre. To obtain the FC, fR, ETCO2 and SPO2 values, 20 animal samples were used. FC presented mean values (± standard deviation) of 134 ± 20.67 beats per minute (bpm), showing a maximum value of 180 bpm and a minimum of 103 bpm. The mean fR was 24.5 ± 5.61 breaths per minute (bpm), with a maximum value of 34 bpm and a minimum of 14 bpm, and SPO2 was 96 ± 2.10 %. Moreover, the values obtained in the analysis of exhaled gases showed a ETCO2 at 44.6 ± 5.41 mmHg, with a maximum value of 53 mmHg and minimum value of 34 mmHg. The arterial pressure was obtained from 19 animals, yielding the following values: 135.8 ± 16.29 mmHg for systolic pressure, 81.6 ± 14.10 mmHg for diastolic pressure and 103.3 ± 12.65 mmHg for mean pressure. Samples from 18 animals were used to measure the arterial blood gas. The values obtained were as follows: 7.497 ± 0.019 for Mean pH , 41.7 ± 6.95 mmHg for partial O2 pressure, 90.65 ± 2.5 mmHg for partial CO2 pressure, 32.8 ± 2.18 mmol/L for total CO2, 7.57 ± 1.9 mmol/L for base excess, 31.5 ± 2.12 mmol/L for bicarbonate and 97.55 ± 0.64 for oxygen saturation. Discussion: The animals seemed submissive and able to be conditioned and therefore it was easy to obtain basal values. These data were slightly different from the values obtained in other studies, thus becoming more reliable to be used as parameters in exsperiments employing this species. There seem to be interspecies differences when one intends to make a comparison with human beings. Values such as O2 concentration in arterial blood are normally lower in swine, possibly due to a lower hemoglobin concentration and a higher body temperature in the species. Despite some differences, there are many physiological similarities with human beings, which allows for the conclusion that swine is a great species to be employed in the biomedical research.
id UFRGS-2_52afb8a9e3d0a45466199d0c3730b5b3
oai_identifier_str oai:www.lume.ufrgs.br:10183/29189
network_acronym_str UFRGS-2
network_name_str Repositório Institucional da UFRGS
repository_id_str
spelling Gianotti, GiordanoBeheregaray, Wanessa KrugerBianchi, Simone PassosMombachi, Verônica SantosCarregaro, Adriano BonfimContesini, Emerson Antônio2011-05-27T06:00:14Z20101678-0345http://hdl.handle.net/10183/29189000745552Background: The use of animals in biomedical research is of great importance. It is fundamental for the development and improvement of new practices and technologies. The selection of the species must take into consideration the practicality of handling and the suitability for the experiment, and it must have low operational costs. Swine are important as an experimental model in several experiment areas, because the functionality of many of their organic systems is developed similarly as it is in humans. Swine are animals that become easily stressed. For that reason, their conditioning is necessary to allow the obtainment of data that is closer to normal parameters. This study aims at reporting the physiological values obtained from awake swine, under normal conditions and minimum stress. Materials, Methods & Results: The animals were maintained under ideal environmental conditions, and they were always handled and conditioned by the same persons. Twenty crossbred swine were evaluated, aged between 60 and 90 days and with a body mass ranging between 17 and 25 kg. The parameters considered were cardiac frequency (FC), hemoglobin oxygen saturation (pulse oxymetry – SPO2), respiratory frequency (fR), end tidal carbon dioxide (ETCO2), systolic (PAM), diastolic (PAD) and mean (PAM) arterial pressure and arterial blood gas values – pH, arterial pressure of CO2 (PACO2), arterial pressure of O2 (PAO2), total CO2 (TCO2), base excess (EB), bicarbonate (HCO3) and O2 saturation (SATO2). The experiment was developed in compliance with the Standards of Animal Ethics and Welfare recommended by the National Council on the Control of Animal Experiments and with Law 11.794 of October 2008, being further approved by the Ethics Committee of the Hospital de Clínicas de Porto Alegre. To obtain the FC, fR, ETCO2 and SPO2 values, 20 animal samples were used. FC presented mean values (± standard deviation) of 134 ± 20.67 beats per minute (bpm), showing a maximum value of 180 bpm and a minimum of 103 bpm. The mean fR was 24.5 ± 5.61 breaths per minute (bpm), with a maximum value of 34 bpm and a minimum of 14 bpm, and SPO2 was 96 ± 2.10 %. Moreover, the values obtained in the analysis of exhaled gases showed a ETCO2 at 44.6 ± 5.41 mmHg, with a maximum value of 53 mmHg and minimum value of 34 mmHg. The arterial pressure was obtained from 19 animals, yielding the following values: 135.8 ± 16.29 mmHg for systolic pressure, 81.6 ± 14.10 mmHg for diastolic pressure and 103.3 ± 12.65 mmHg for mean pressure. Samples from 18 animals were used to measure the arterial blood gas. The values obtained were as follows: 7.497 ± 0.019 for Mean pH , 41.7 ± 6.95 mmHg for partial O2 pressure, 90.65 ± 2.5 mmHg for partial CO2 pressure, 32.8 ± 2.18 mmol/L for total CO2, 7.57 ± 1.9 mmol/L for base excess, 31.5 ± 2.12 mmol/L for bicarbonate and 97.55 ± 0.64 for oxygen saturation. Discussion: The animals seemed submissive and able to be conditioned and therefore it was easy to obtain basal values. These data were slightly different from the values obtained in other studies, thus becoming more reliable to be used as parameters in exsperiments employing this species. There seem to be interspecies differences when one intends to make a comparison with human beings. Values such as O2 concentration in arterial blood are normally lower in swine, possibly due to a lower hemoglobin concentration and a higher body temperature in the species. Despite some differences, there are many physiological similarities with human beings, which allows for the conclusion that swine is a great species to be employed in the biomedical research.application/pdfporActa scientiae veterinariae. Porto Alegre, RS. Vol. 38, n.2 (2010), p. 133-137Cirurgia veterinaria : SuinosPesquisa biomédicaSwineBiomedical researchPhysiological parametersPigsSuino como modelo experimental na pesquisa biomédica: valores fisiológicos normaisinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/otherinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFRGSinstname:Universidade Federal do Rio Grande do Sul (UFRGS)instacron:UFRGSTEXT000745552.pdf.txt000745552.pdf.txtExtracted Texttext/plain20124http://www.lume.ufrgs.br/bitstream/10183/29189/2/000745552.pdf.txtee9ce23741c679b7122219112958b37aMD52ORIGINAL000745552.pdf000745552.pdfTexto completoapplication/pdf88285http://www.lume.ufrgs.br/bitstream/10183/29189/1/000745552.pdf1da663a62e21b0d4a55d893a2ff0c12dMD51THUMBNAIL000745552.pdf.jpg000745552.pdf.jpgGenerated Thumbnailimage/jpeg1942http://www.lume.ufrgs.br/bitstream/10183/29189/3/000745552.pdf.jpg4abf13b66fad1aa31a9c617b48006938MD5310183/291892018-10-09 09:17:37.32oai:www.lume.ufrgs.br:10183/29189Repositório de PublicaçõesPUBhttps://lume.ufrgs.br/oai/requestopendoar:2018-10-09T12:17:37Repositório Institucional da UFRGS - Universidade Federal do Rio Grande do Sul (UFRGS)false
dc.title.pt_BR.fl_str_mv Suino como modelo experimental na pesquisa biomédica: valores fisiológicos normais
title Suino como modelo experimental na pesquisa biomédica: valores fisiológicos normais
spellingShingle Suino como modelo experimental na pesquisa biomédica: valores fisiológicos normais
Gianotti, Giordano
Cirurgia veterinaria : Suinos
Pesquisa biomédica
Swine
Biomedical research
Physiological parameters
Pigs
title_short Suino como modelo experimental na pesquisa biomédica: valores fisiológicos normais
title_full Suino como modelo experimental na pesquisa biomédica: valores fisiológicos normais
title_fullStr Suino como modelo experimental na pesquisa biomédica: valores fisiológicos normais
title_full_unstemmed Suino como modelo experimental na pesquisa biomédica: valores fisiológicos normais
title_sort Suino como modelo experimental na pesquisa biomédica: valores fisiológicos normais
author Gianotti, Giordano
author_facet Gianotti, Giordano
Beheregaray, Wanessa Kruger
Bianchi, Simone Passos
Mombachi, Verônica Santos
Carregaro, Adriano Bonfim
Contesini, Emerson Antônio
author_role author
author2 Beheregaray, Wanessa Kruger
Bianchi, Simone Passos
Mombachi, Verônica Santos
Carregaro, Adriano Bonfim
Contesini, Emerson Antônio
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Gianotti, Giordano
Beheregaray, Wanessa Kruger
Bianchi, Simone Passos
Mombachi, Verônica Santos
Carregaro, Adriano Bonfim
Contesini, Emerson Antônio
dc.subject.por.fl_str_mv Cirurgia veterinaria : Suinos
Pesquisa biomédica
topic Cirurgia veterinaria : Suinos
Pesquisa biomédica
Swine
Biomedical research
Physiological parameters
Pigs
dc.subject.eng.fl_str_mv Swine
Biomedical research
Physiological parameters
Pigs
description Background: The use of animals in biomedical research is of great importance. It is fundamental for the development and improvement of new practices and technologies. The selection of the species must take into consideration the practicality of handling and the suitability for the experiment, and it must have low operational costs. Swine are important as an experimental model in several experiment areas, because the functionality of many of their organic systems is developed similarly as it is in humans. Swine are animals that become easily stressed. For that reason, their conditioning is necessary to allow the obtainment of data that is closer to normal parameters. This study aims at reporting the physiological values obtained from awake swine, under normal conditions and minimum stress. Materials, Methods & Results: The animals were maintained under ideal environmental conditions, and they were always handled and conditioned by the same persons. Twenty crossbred swine were evaluated, aged between 60 and 90 days and with a body mass ranging between 17 and 25 kg. The parameters considered were cardiac frequency (FC), hemoglobin oxygen saturation (pulse oxymetry – SPO2), respiratory frequency (fR), end tidal carbon dioxide (ETCO2), systolic (PAM), diastolic (PAD) and mean (PAM) arterial pressure and arterial blood gas values – pH, arterial pressure of CO2 (PACO2), arterial pressure of O2 (PAO2), total CO2 (TCO2), base excess (EB), bicarbonate (HCO3) and O2 saturation (SATO2). The experiment was developed in compliance with the Standards of Animal Ethics and Welfare recommended by the National Council on the Control of Animal Experiments and with Law 11.794 of October 2008, being further approved by the Ethics Committee of the Hospital de Clínicas de Porto Alegre. To obtain the FC, fR, ETCO2 and SPO2 values, 20 animal samples were used. FC presented mean values (± standard deviation) of 134 ± 20.67 beats per minute (bpm), showing a maximum value of 180 bpm and a minimum of 103 bpm. The mean fR was 24.5 ± 5.61 breaths per minute (bpm), with a maximum value of 34 bpm and a minimum of 14 bpm, and SPO2 was 96 ± 2.10 %. Moreover, the values obtained in the analysis of exhaled gases showed a ETCO2 at 44.6 ± 5.41 mmHg, with a maximum value of 53 mmHg and minimum value of 34 mmHg. The arterial pressure was obtained from 19 animals, yielding the following values: 135.8 ± 16.29 mmHg for systolic pressure, 81.6 ± 14.10 mmHg for diastolic pressure and 103.3 ± 12.65 mmHg for mean pressure. Samples from 18 animals were used to measure the arterial blood gas. The values obtained were as follows: 7.497 ± 0.019 for Mean pH , 41.7 ± 6.95 mmHg for partial O2 pressure, 90.65 ± 2.5 mmHg for partial CO2 pressure, 32.8 ± 2.18 mmol/L for total CO2, 7.57 ± 1.9 mmol/L for base excess, 31.5 ± 2.12 mmol/L for bicarbonate and 97.55 ± 0.64 for oxygen saturation. Discussion: The animals seemed submissive and able to be conditioned and therefore it was easy to obtain basal values. These data were slightly different from the values obtained in other studies, thus becoming more reliable to be used as parameters in exsperiments employing this species. There seem to be interspecies differences when one intends to make a comparison with human beings. Values such as O2 concentration in arterial blood are normally lower in swine, possibly due to a lower hemoglobin concentration and a higher body temperature in the species. Despite some differences, there are many physiological similarities with human beings, which allows for the conclusion that swine is a great species to be employed in the biomedical research.
publishDate 2010
dc.date.issued.fl_str_mv 2010
dc.date.accessioned.fl_str_mv 2011-05-27T06:00:14Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/other
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10183/29189
dc.identifier.issn.pt_BR.fl_str_mv 1678-0345
dc.identifier.nrb.pt_BR.fl_str_mv 000745552
identifier_str_mv 1678-0345
000745552
url http://hdl.handle.net/10183/29189
dc.language.iso.fl_str_mv por
language por
dc.relation.ispartof.pt_BR.fl_str_mv Acta scientiae veterinariae. Porto Alegre, RS. Vol. 38, n.2 (2010), p. 133-137
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFRGS
instname:Universidade Federal do Rio Grande do Sul (UFRGS)
instacron:UFRGS
instname_str Universidade Federal do Rio Grande do Sul (UFRGS)
instacron_str UFRGS
institution UFRGS
reponame_str Repositório Institucional da UFRGS
collection Repositório Institucional da UFRGS
bitstream.url.fl_str_mv http://www.lume.ufrgs.br/bitstream/10183/29189/2/000745552.pdf.txt
http://www.lume.ufrgs.br/bitstream/10183/29189/1/000745552.pdf
http://www.lume.ufrgs.br/bitstream/10183/29189/3/000745552.pdf.jpg
bitstream.checksum.fl_str_mv ee9ce23741c679b7122219112958b37a
1da663a62e21b0d4a55d893a2ff0c12d
4abf13b66fad1aa31a9c617b48006938
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFRGS - Universidade Federal do Rio Grande do Sul (UFRGS)
repository.mail.fl_str_mv
_version_ 1798487108825907200