Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres por radiologia convencional

Detalhes bibliográficos
Autor(a) principal: Cunha, João Paulo Monteiro Carvalho Mori da
Data de Publicação: 2017
Outros Autores: Cunha, Marina Gabriela Monteiro Carvalho Mori da, Gomes, Cristiano, Treichel, Tiago Luís Eilers, Marconato, Francieli, Linhares, Marcella Teixeira, Beckmann, Diego Vilibaldo, Hora, Aline Medeiros da, Godoy, Carmen Lice Buckman de, Pippi, Ney Luis
Tipo de documento: Artigo
Idioma: por
Título da fonte: Repositório Institucional da UFRGS
Texto Completo: http://hdl.handle.net/10183/181577
Resumo: Background: Several routes of administration have been used for cell and gene therapy delivery in kidney disease in the last years. Moreover, a more homogenous distribution and a higher response was observed when administered intra-arterially. The main objective of the present study was to describe and to compare the use of Fogarty thru-lumen embolectomy catheter with angiographic catheter through the femoral artery by using conventional radiology as a guide. Materials, Methods & Results: Seven healthy dogs were used in these experiments. First, a Fogarty thru-lumen embolectomy catheter was introduced followed by an angiographic catheter. The primary outcome was the number of attempts for the placement of the introducer and the number of radiographic studies to carry out nephrography. Preceding the surgical procedure, ultrasonographic evaluation was performed in all animals in order to measure the diameter of the left and right femoral arteries, left and right renal and abdominal aorta at the renal level. After trichotomy and antisepsis of the medial face of the two pelvic limbs, the 6F valve introducer was placed based on the modified Seldinger technique Thereafter, aortography was performed, showing its collateral arteries, with contrast injection, and it was estimated how much of the Fogarty 5,5F catheter had to be introduced. Subsequently, a guidewire was inserted through the catheter followed by the Fogarty catheter. Another x-ray was taken to show the position of the catheter. It was observed whether the catheter was positioned correctly and the cuff was filled, and then another contrasting radiograph was performed. If the contrast was not going to the kidneys, the cuff of the catheter was deflated, the catheter was repositioned and a new contrast radiography was performed. For the angiographic catheters technique, it was estimated how much of the catheter needed to be introduced, and then the curvature of the catheter was directed to the left kidney, followed by placement of the guidewire. The guidewire was then removed and X-rays were taken to confirm the position as many times as necessary for the correct positioning of the catheter. After selective catheterization of the left kidney, the catheter was removed and its tip was repositioned for catheterization of the right kidney, repeating the same procedure After the radiographic evaluation, the 6F valve introducer was removed followed by the hemostasis of the femoral artery. In five out of seven animals it was possible to place the introducer tube 6F. Angiographic catheter technique needed significantly more radiographic films compared to Fogarty catheter when both arteries were evaluated. No significant difference was observed when compared to only one renal artery. The only complication observed was hematoma in three animals. Discussion: The access of the renal artery for drug delivery and cell therapy is possible using both Fogarty thru-lumen embolectomy catheter and angiographic catheter with conventional radiology as a guide in dogs over 10 kg. However, we considered the Fogarty catheter easier to be applied, since only one procedure is needed to access both renal arteries, thus making it less expensive and faster to run. If access to only one renal artery is required, the angiographic catheter is recommended, since cell therapy would be administered more selectively in the target kidney.
id UFRGS-2_b36f8f2bde586c13d220906e0baff262
oai_identifier_str oai:www.lume.ufrgs.br:10183/181577
network_acronym_str UFRGS-2
network_name_str Repositório Institucional da UFRGS
repository_id_str
spelling Cunha, João Paulo Monteiro Carvalho Mori daCunha, Marina Gabriela Monteiro Carvalho Mori daGomes, CristianoTreichel, Tiago Luís EilersMarconato, FrancieliLinhares, Marcella TeixeiraBeckmann, Diego VilibaldoHora, Aline Medeiros daGodoy, Carmen Lice Buckman dePippi, Ney Luis2018-09-01T02:54:58Z20171678-0345http://hdl.handle.net/10183/181577001073478Background: Several routes of administration have been used for cell and gene therapy delivery in kidney disease in the last years. Moreover, a more homogenous distribution and a higher response was observed when administered intra-arterially. The main objective of the present study was to describe and to compare the use of Fogarty thru-lumen embolectomy catheter with angiographic catheter through the femoral artery by using conventional radiology as a guide. Materials, Methods & Results: Seven healthy dogs were used in these experiments. First, a Fogarty thru-lumen embolectomy catheter was introduced followed by an angiographic catheter. The primary outcome was the number of attempts for the placement of the introducer and the number of radiographic studies to carry out nephrography. Preceding the surgical procedure, ultrasonographic evaluation was performed in all animals in order to measure the diameter of the left and right femoral arteries, left and right renal and abdominal aorta at the renal level. After trichotomy and antisepsis of the medial face of the two pelvic limbs, the 6F valve introducer was placed based on the modified Seldinger technique Thereafter, aortography was performed, showing its collateral arteries, with contrast injection, and it was estimated how much of the Fogarty 5,5F catheter had to be introduced. Subsequently, a guidewire was inserted through the catheter followed by the Fogarty catheter. Another x-ray was taken to show the position of the catheter. It was observed whether the catheter was positioned correctly and the cuff was filled, and then another contrasting radiograph was performed. If the contrast was not going to the kidneys, the cuff of the catheter was deflated, the catheter was repositioned and a new contrast radiography was performed. For the angiographic catheters technique, it was estimated how much of the catheter needed to be introduced, and then the curvature of the catheter was directed to the left kidney, followed by placement of the guidewire. The guidewire was then removed and X-rays were taken to confirm the position as many times as necessary for the correct positioning of the catheter. After selective catheterization of the left kidney, the catheter was removed and its tip was repositioned for catheterization of the right kidney, repeating the same procedure After the radiographic evaluation, the 6F valve introducer was removed followed by the hemostasis of the femoral artery. In five out of seven animals it was possible to place the introducer tube 6F. Angiographic catheter technique needed significantly more radiographic films compared to Fogarty catheter when both arteries were evaluated. No significant difference was observed when compared to only one renal artery. The only complication observed was hematoma in three animals. Discussion: The access of the renal artery for drug delivery and cell therapy is possible using both Fogarty thru-lumen embolectomy catheter and angiographic catheter with conventional radiology as a guide in dogs over 10 kg. However, we considered the Fogarty catheter easier to be applied, since only one procedure is needed to access both renal arteries, thus making it less expensive and faster to run. If access to only one renal artery is required, the angiographic catheter is recommended, since cell therapy would be administered more selectively in the target kidney.application/pdfporActa scientiae veterinariae. Porto Alegre, RS. Vol. 45 (2017), Pub. 1503, 7 p.CateterismoEmbolectomia com balãoAngiografiaArtéria renalRadiografia intervencionistaTerapia celularCãesArteriographyRenal diseaseCellular therapyIntervencionismAcesso minimamente invasivo da artéria renal com diferentes tipos de cateteres por radiologia convencionalMinimally invasive approach to renal artery using different types of catheter by conventional radiology info:eu-repo/semantics/articleinfo:eu-repo/semantics/otherinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFRGSinstname:Universidade Federal do Rio Grande do Sul (UFRGS)instacron:UFRGSORIGINAL001073478.pdfTexto completoapplication/pdf795726http://www.lume.ufrgs.br/bitstream/10183/181577/1/001073478.pdfd6a9fd2961000ff2238be689b0dc9abeMD51TEXT001073478.pdf.txt001073478.pdf.txtExtracted Texttext/plain30762http://www.lume.ufrgs.br/bitstream/10183/181577/2/001073478.pdf.txt8a9acbcbbcef336e1469db0bd7213a31MD52THUMBNAIL001073478.pdf.jpg001073478.pdf.jpgGenerated Thumbnailimage/jpeg1943http://www.lume.ufrgs.br/bitstream/10183/181577/3/001073478.pdf.jpgfcbe8fea40a3a25de761561c2d466bd7MD5310183/1815772018-10-05 07:45:30.37oai:www.lume.ufrgs.br:10183/181577Repositório de PublicaçõesPUBhttps://lume.ufrgs.br/oai/requestopendoar:2018-10-05T10:45:30Repositório Institucional da UFRGS - Universidade Federal do Rio Grande do Sul (UFRGS)false
dc.title.pt_BR.fl_str_mv Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres por radiologia convencional
dc.title.alternative.en.fl_str_mv Minimally invasive approach to renal artery using different types of catheter by conventional radiology
title Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres por radiologia convencional
spellingShingle Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres por radiologia convencional
Cunha, João Paulo Monteiro Carvalho Mori da
Cateterismo
Embolectomia com balão
Angiografia
Artéria renal
Radiografia intervencionista
Terapia celular
Cães
Arteriography
Renal disease
Cellular therapy
Intervencionism
title_short Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres por radiologia convencional
title_full Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres por radiologia convencional
title_fullStr Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres por radiologia convencional
title_full_unstemmed Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres por radiologia convencional
title_sort Acesso minimamente invasivo da artéria renal com diferentes tipos de cateteres por radiologia convencional
author Cunha, João Paulo Monteiro Carvalho Mori da
author_facet Cunha, João Paulo Monteiro Carvalho Mori da
Cunha, Marina Gabriela Monteiro Carvalho Mori da
Gomes, Cristiano
Treichel, Tiago Luís Eilers
Marconato, Francieli
Linhares, Marcella Teixeira
Beckmann, Diego Vilibaldo
Hora, Aline Medeiros da
Godoy, Carmen Lice Buckman de
Pippi, Ney Luis
author_role author
author2 Cunha, Marina Gabriela Monteiro Carvalho Mori da
Gomes, Cristiano
Treichel, Tiago Luís Eilers
Marconato, Francieli
Linhares, Marcella Teixeira
Beckmann, Diego Vilibaldo
Hora, Aline Medeiros da
Godoy, Carmen Lice Buckman de
Pippi, Ney Luis
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Cunha, João Paulo Monteiro Carvalho Mori da
Cunha, Marina Gabriela Monteiro Carvalho Mori da
Gomes, Cristiano
Treichel, Tiago Luís Eilers
Marconato, Francieli
Linhares, Marcella Teixeira
Beckmann, Diego Vilibaldo
Hora, Aline Medeiros da
Godoy, Carmen Lice Buckman de
Pippi, Ney Luis
dc.subject.por.fl_str_mv Cateterismo
Embolectomia com balão
Angiografia
Artéria renal
Radiografia intervencionista
Terapia celular
Cães
topic Cateterismo
Embolectomia com balão
Angiografia
Artéria renal
Radiografia intervencionista
Terapia celular
Cães
Arteriography
Renal disease
Cellular therapy
Intervencionism
dc.subject.eng.fl_str_mv Arteriography
Renal disease
Cellular therapy
Intervencionism
description Background: Several routes of administration have been used for cell and gene therapy delivery in kidney disease in the last years. Moreover, a more homogenous distribution and a higher response was observed when administered intra-arterially. The main objective of the present study was to describe and to compare the use of Fogarty thru-lumen embolectomy catheter with angiographic catheter through the femoral artery by using conventional radiology as a guide. Materials, Methods & Results: Seven healthy dogs were used in these experiments. First, a Fogarty thru-lumen embolectomy catheter was introduced followed by an angiographic catheter. The primary outcome was the number of attempts for the placement of the introducer and the number of radiographic studies to carry out nephrography. Preceding the surgical procedure, ultrasonographic evaluation was performed in all animals in order to measure the diameter of the left and right femoral arteries, left and right renal and abdominal aorta at the renal level. After trichotomy and antisepsis of the medial face of the two pelvic limbs, the 6F valve introducer was placed based on the modified Seldinger technique Thereafter, aortography was performed, showing its collateral arteries, with contrast injection, and it was estimated how much of the Fogarty 5,5F catheter had to be introduced. Subsequently, a guidewire was inserted through the catheter followed by the Fogarty catheter. Another x-ray was taken to show the position of the catheter. It was observed whether the catheter was positioned correctly and the cuff was filled, and then another contrasting radiograph was performed. If the contrast was not going to the kidneys, the cuff of the catheter was deflated, the catheter was repositioned and a new contrast radiography was performed. For the angiographic catheters technique, it was estimated how much of the catheter needed to be introduced, and then the curvature of the catheter was directed to the left kidney, followed by placement of the guidewire. The guidewire was then removed and X-rays were taken to confirm the position as many times as necessary for the correct positioning of the catheter. After selective catheterization of the left kidney, the catheter was removed and its tip was repositioned for catheterization of the right kidney, repeating the same procedure After the radiographic evaluation, the 6F valve introducer was removed followed by the hemostasis of the femoral artery. In five out of seven animals it was possible to place the introducer tube 6F. Angiographic catheter technique needed significantly more radiographic films compared to Fogarty catheter when both arteries were evaluated. No significant difference was observed when compared to only one renal artery. The only complication observed was hematoma in three animals. Discussion: The access of the renal artery for drug delivery and cell therapy is possible using both Fogarty thru-lumen embolectomy catheter and angiographic catheter with conventional radiology as a guide in dogs over 10 kg. However, we considered the Fogarty catheter easier to be applied, since only one procedure is needed to access both renal arteries, thus making it less expensive and faster to run. If access to only one renal artery is required, the angiographic catheter is recommended, since cell therapy would be administered more selectively in the target kidney.
publishDate 2017
dc.date.issued.fl_str_mv 2017
dc.date.accessioned.fl_str_mv 2018-09-01T02:54:58Z
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/other
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10183/181577
dc.identifier.issn.pt_BR.fl_str_mv 1678-0345
dc.identifier.nrb.pt_BR.fl_str_mv 001073478
identifier_str_mv 1678-0345
001073478
url http://hdl.handle.net/10183/181577
dc.language.iso.fl_str_mv por
language por
dc.relation.ispartof.pt_BR.fl_str_mv Acta scientiae veterinariae. Porto Alegre, RS. Vol. 45 (2017), Pub. 1503, 7 p.
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFRGS
instname:Universidade Federal do Rio Grande do Sul (UFRGS)
instacron:UFRGS
instname_str Universidade Federal do Rio Grande do Sul (UFRGS)
instacron_str UFRGS
institution UFRGS
reponame_str Repositório Institucional da UFRGS
collection Repositório Institucional da UFRGS
bitstream.url.fl_str_mv http://www.lume.ufrgs.br/bitstream/10183/181577/1/001073478.pdf
http://www.lume.ufrgs.br/bitstream/10183/181577/2/001073478.pdf.txt
http://www.lume.ufrgs.br/bitstream/10183/181577/3/001073478.pdf.jpg
bitstream.checksum.fl_str_mv d6a9fd2961000ff2238be689b0dc9abe
8a9acbcbbcef336e1469db0bd7213a31
fcbe8fea40a3a25de761561c2d466bd7
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFRGS - Universidade Federal do Rio Grande do Sul (UFRGS)
repository.mail.fl_str_mv
_version_ 1815447667231162368