Efficacy of light-emitting diode (LED) photobiomodulation in pain management, facial edema, trismus, and quality of life after extraction of retained lower third molars : A randomized, double-blind, placebo-controlled clinical trial

Detalhes bibliográficos
Autor(a) principal: Tenis, Carlos Alberto
Data de Publicação: 2018
Outros Autores: Martins, Manoela Domingues, Gonçalves, Marcela Leticia Leal, Silva, Daniela de Fátima Teixeira da, Cunha Filho, João Julio da, Martins, Marco Antonio Trevizani, Mesquita-Ferrari, Raquel Agnelli, Bussadori, Sandra Kalil, Fernandes, Kristianne Porta Santos
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UFRGS
Texto Completo: http://hdl.handle.net/10183/206451
Resumo: Background: In dentistry, one of the most common surgical procedures is the removal of retained third molars. This surgery generates great morbidity to the participants for causing pain, edema, and trismus due to surgical trauma. The objective of the present study is to evaluate the efficacy of photobiomodulation with light emitting diode (LED) in the control of pain, facial edema, trismus, and quality of life resulting from the extraction of retained lower third molars. Methods:A randomized, double-blind, placebo-controlled clinical trial involving 38 adult participants, who meet the criteria of eligibility and agree to participate in the study. Before the surgeries are performed, the facial and mouth opening measures of all the participants will be taken. Immediately after the surgeries, participants will be randomized into 2 groups. In the LED group, participants will receive LED applications (intra oral with 660 nm, 12J and extraoral with 850 nm, 108J) in the immediate postoperative, first and second days after the surgical procedure. In the control group, the participants will be attended in the same way as in the LED group, however, the person in charge of the application will simulate the irradiation. Pain (EVA and NRS-101), postoperative edema, trismus, temperature, dysphagia, and hematoma will be evaluated after 1, 2, 5, and 7 days. The oral health impact profile (OHIP-14 Questionnaire) and anxiety analysis (Beck anxiety inventory -BAI) questionnaires will be applied preoperatively and 7 days after treatment. The appropriate statistical tests will be applied for each specific analysis in a significance level of 5%. Discussion: Although the use of low-power laser in the postoperative has shown good results in the control of postoperative sequelae, this is the first study on the efficacy of the use of LED in this situation. Abbreviations: BAI = Beck anxiety inventory, LED = light emitting diode, NRS-101 = numerical rating scale 101, OHIP-14 = oral health impact profile, PBM = pohotobiomodulation, VAS = visual analog scale.
id UFRGS-2_e035c36e21191913fd5e403345a2e351
oai_identifier_str oai:www.lume.ufrgs.br:10183/206451
network_acronym_str UFRGS-2
network_name_str Repositório Institucional da UFRGS
repository_id_str
spelling Tenis, Carlos AlbertoMartins, Manoela DominguesGonçalves, Marcela Leticia LealSilva, Daniela de Fátima Teixeira daCunha Filho, João Julio daMartins, Marco Antonio TrevizaniMesquita-Ferrari, Raquel AgnelliBussadori, Sandra KalilFernandes, Kristianne Porta Santos2020-03-05T04:15:19Z20180025-7974http://hdl.handle.net/10183/206451001112878Background: In dentistry, one of the most common surgical procedures is the removal of retained third molars. This surgery generates great morbidity to the participants for causing pain, edema, and trismus due to surgical trauma. The objective of the present study is to evaluate the efficacy of photobiomodulation with light emitting diode (LED) in the control of pain, facial edema, trismus, and quality of life resulting from the extraction of retained lower third molars. Methods:A randomized, double-blind, placebo-controlled clinical trial involving 38 adult participants, who meet the criteria of eligibility and agree to participate in the study. Before the surgeries are performed, the facial and mouth opening measures of all the participants will be taken. Immediately after the surgeries, participants will be randomized into 2 groups. In the LED group, participants will receive LED applications (intra oral with 660 nm, 12J and extraoral with 850 nm, 108J) in the immediate postoperative, first and second days after the surgical procedure. In the control group, the participants will be attended in the same way as in the LED group, however, the person in charge of the application will simulate the irradiation. Pain (EVA and NRS-101), postoperative edema, trismus, temperature, dysphagia, and hematoma will be evaluated after 1, 2, 5, and 7 days. The oral health impact profile (OHIP-14 Questionnaire) and anxiety analysis (Beck anxiety inventory -BAI) questionnaires will be applied preoperatively and 7 days after treatment. The appropriate statistical tests will be applied for each specific analysis in a significance level of 5%. Discussion: Although the use of low-power laser in the postoperative has shown good results in the control of postoperative sequelae, this is the first study on the efficacy of the use of LED in this situation. Abbreviations: BAI = Beck anxiety inventory, LED = light emitting diode, NRS-101 = numerical rating scale 101, OHIP-14 = oral health impact profile, PBM = pohotobiomodulation, VAS = visual analog scale.application/pdfengMedicine (Baltimore). Hagerstown. Vol. 97, no. 37 (Sept. 2018), p. 1-6, e12264Método duplo-cegoEdemaFaceLasers semicondutoresTerapia com luz de baixa intensidadeDente serotinoManejo da dorQualidade de vidaProjetos de pesquisaExtração dentáriaTrismoDouble-Blind MethodLasers, SemiconductorLow-Level Light TherapyMolar, ThirdPain ManagementQuality of LifeResearch DesignTooth ExtractionTrismusEfficacy of light-emitting diode (LED) photobiomodulation in pain management, facial edema, trismus, and quality of life after extraction of retained lower third molars : A randomized, double-blind, placebo-controlled clinical trialEstrangeiroinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFRGSinstname:Universidade Federal do Rio Grande do Sul (UFRGS)instacron:UFRGSTEXT001112878.pdf.txt001112878.pdf.txtExtracted Texttext/plain29708http://www.lume.ufrgs.br/bitstream/10183/206451/2/001112878.pdf.txtbc8a196a51489c63f67ebb50bc5148b6MD52ORIGINAL001112878.pdfTexto completo (inglês)application/pdf254096http://www.lume.ufrgs.br/bitstream/10183/206451/1/001112878.pdf9e3369df8117374d76112de7d5d7b6c4MD5110183/2064512020-03-06 04:14:15.482174oai:www.lume.ufrgs.br:10183/206451Repositório de PublicaçõesPUBhttps://lume.ufrgs.br/oai/requestopendoar:2020-03-06T07:14:15Repositório Institucional da UFRGS - Universidade Federal do Rio Grande do Sul (UFRGS)false
dc.title.pt_BR.fl_str_mv Efficacy of light-emitting diode (LED) photobiomodulation in pain management, facial edema, trismus, and quality of life after extraction of retained lower third molars : A randomized, double-blind, placebo-controlled clinical trial
title Efficacy of light-emitting diode (LED) photobiomodulation in pain management, facial edema, trismus, and quality of life after extraction of retained lower third molars : A randomized, double-blind, placebo-controlled clinical trial
spellingShingle Efficacy of light-emitting diode (LED) photobiomodulation in pain management, facial edema, trismus, and quality of life after extraction of retained lower third molars : A randomized, double-blind, placebo-controlled clinical trial
Tenis, Carlos Alberto
Método duplo-cego
Edema
Face
Lasers semicondutores
Terapia com luz de baixa intensidade
Dente serotino
Manejo da dor
Qualidade de vida
Projetos de pesquisa
Extração dentária
Trismo
Double-Blind Method
Lasers, Semiconductor
Low-Level Light Therapy
Molar, Third
Pain Management
Quality of Life
Research Design
Tooth Extraction
Trismus
title_short Efficacy of light-emitting diode (LED) photobiomodulation in pain management, facial edema, trismus, and quality of life after extraction of retained lower third molars : A randomized, double-blind, placebo-controlled clinical trial
title_full Efficacy of light-emitting diode (LED) photobiomodulation in pain management, facial edema, trismus, and quality of life after extraction of retained lower third molars : A randomized, double-blind, placebo-controlled clinical trial
title_fullStr Efficacy of light-emitting diode (LED) photobiomodulation in pain management, facial edema, trismus, and quality of life after extraction of retained lower third molars : A randomized, double-blind, placebo-controlled clinical trial
title_full_unstemmed Efficacy of light-emitting diode (LED) photobiomodulation in pain management, facial edema, trismus, and quality of life after extraction of retained lower third molars : A randomized, double-blind, placebo-controlled clinical trial
title_sort Efficacy of light-emitting diode (LED) photobiomodulation in pain management, facial edema, trismus, and quality of life after extraction of retained lower third molars : A randomized, double-blind, placebo-controlled clinical trial
author Tenis, Carlos Alberto
author_facet Tenis, Carlos Alberto
Martins, Manoela Domingues
Gonçalves, Marcela Leticia Leal
Silva, Daniela de Fátima Teixeira da
Cunha Filho, João Julio da
Martins, Marco Antonio Trevizani
Mesquita-Ferrari, Raquel Agnelli
Bussadori, Sandra Kalil
Fernandes, Kristianne Porta Santos
author_role author
author2 Martins, Manoela Domingues
Gonçalves, Marcela Leticia Leal
Silva, Daniela de Fátima Teixeira da
Cunha Filho, João Julio da
Martins, Marco Antonio Trevizani
Mesquita-Ferrari, Raquel Agnelli
Bussadori, Sandra Kalil
Fernandes, Kristianne Porta Santos
author2_role author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Tenis, Carlos Alberto
Martins, Manoela Domingues
Gonçalves, Marcela Leticia Leal
Silva, Daniela de Fátima Teixeira da
Cunha Filho, João Julio da
Martins, Marco Antonio Trevizani
Mesquita-Ferrari, Raquel Agnelli
Bussadori, Sandra Kalil
Fernandes, Kristianne Porta Santos
dc.subject.por.fl_str_mv Método duplo-cego
Edema
Face
Lasers semicondutores
Terapia com luz de baixa intensidade
Dente serotino
Manejo da dor
Qualidade de vida
Projetos de pesquisa
Extração dentária
Trismo
topic Método duplo-cego
Edema
Face
Lasers semicondutores
Terapia com luz de baixa intensidade
Dente serotino
Manejo da dor
Qualidade de vida
Projetos de pesquisa
Extração dentária
Trismo
Double-Blind Method
Lasers, Semiconductor
Low-Level Light Therapy
Molar, Third
Pain Management
Quality of Life
Research Design
Tooth Extraction
Trismus
dc.subject.eng.fl_str_mv Double-Blind Method
Lasers, Semiconductor
Low-Level Light Therapy
Molar, Third
Pain Management
Quality of Life
Research Design
Tooth Extraction
Trismus
description Background: In dentistry, one of the most common surgical procedures is the removal of retained third molars. This surgery generates great morbidity to the participants for causing pain, edema, and trismus due to surgical trauma. The objective of the present study is to evaluate the efficacy of photobiomodulation with light emitting diode (LED) in the control of pain, facial edema, trismus, and quality of life resulting from the extraction of retained lower third molars. Methods:A randomized, double-blind, placebo-controlled clinical trial involving 38 adult participants, who meet the criteria of eligibility and agree to participate in the study. Before the surgeries are performed, the facial and mouth opening measures of all the participants will be taken. Immediately after the surgeries, participants will be randomized into 2 groups. In the LED group, participants will receive LED applications (intra oral with 660 nm, 12J and extraoral with 850 nm, 108J) in the immediate postoperative, first and second days after the surgical procedure. In the control group, the participants will be attended in the same way as in the LED group, however, the person in charge of the application will simulate the irradiation. Pain (EVA and NRS-101), postoperative edema, trismus, temperature, dysphagia, and hematoma will be evaluated after 1, 2, 5, and 7 days. The oral health impact profile (OHIP-14 Questionnaire) and anxiety analysis (Beck anxiety inventory -BAI) questionnaires will be applied preoperatively and 7 days after treatment. The appropriate statistical tests will be applied for each specific analysis in a significance level of 5%. Discussion: Although the use of low-power laser in the postoperative has shown good results in the control of postoperative sequelae, this is the first study on the efficacy of the use of LED in this situation. Abbreviations: BAI = Beck anxiety inventory, LED = light emitting diode, NRS-101 = numerical rating scale 101, OHIP-14 = oral health impact profile, PBM = pohotobiomodulation, VAS = visual analog scale.
publishDate 2018
dc.date.issued.fl_str_mv 2018
dc.date.accessioned.fl_str_mv 2020-03-05T04:15:19Z
dc.type.driver.fl_str_mv Estrangeiro
info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10183/206451
dc.identifier.issn.pt_BR.fl_str_mv 0025-7974
dc.identifier.nrb.pt_BR.fl_str_mv 001112878
identifier_str_mv 0025-7974
001112878
url http://hdl.handle.net/10183/206451
dc.language.iso.fl_str_mv eng
language eng
dc.relation.ispartof.pt_BR.fl_str_mv Medicine (Baltimore). Hagerstown. Vol. 97, no. 37 (Sept. 2018), p. 1-6, e12264
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFRGS
instname:Universidade Federal do Rio Grande do Sul (UFRGS)
instacron:UFRGS
instname_str Universidade Federal do Rio Grande do Sul (UFRGS)
instacron_str UFRGS
institution UFRGS
reponame_str Repositório Institucional da UFRGS
collection Repositório Institucional da UFRGS
bitstream.url.fl_str_mv http://www.lume.ufrgs.br/bitstream/10183/206451/2/001112878.pdf.txt
http://www.lume.ufrgs.br/bitstream/10183/206451/1/001112878.pdf
bitstream.checksum.fl_str_mv bc8a196a51489c63f67ebb50bc5148b6
9e3369df8117374d76112de7d5d7b6c4
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFRGS - Universidade Federal do Rio Grande do Sul (UFRGS)
repository.mail.fl_str_mv
_version_ 1815447708935127040