Avaliação do estresse oxidativo induzido por superfícies de titânio

Detalhes bibliográficos
Autor(a) principal: Queiroz, Jana Dara Freires de
Data de Publicação: 2011
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFRN
Texto Completo: https://repositorio.ufrn.br/jspui/handle/123456789/12591
Resumo: Commercially pure Titanium (cp Ti) is a material largely used in orthopedic and dental implants due to its biocompatibility properties. Changes in the surface of cp Ti can determine the functional response of the cells such as facilitating implant fixation and stabilization, and increased roughness of the surface has been shown to improve adhesion and cellular proliferation. Various surface modification methods have been developed to increase roughness, such as mechanical, chemical, electrochemical and plasma treatment. An argon plasma treatment generates a surface that has good mechanical proprieties without chemical composition modification. Besides the topography, biological responses to the implant contribute significantly to its success. Oxidative stress induced by the biomaterials is considered one of the major causes of implant failure. For this reason the oxidative potential of titanium surfaces subjected to plasma treatment was evaluated on this work. CHO-k1 cells were cultivated on smooth or roughed Ti disks, and after three days, the redox balance was investigated measuring reactive oxygen species (ROS) generation, total antioxidant capacity and biomarkers of ROS attack. The results showed cells grown on titanium surfaces are subjected to intracellular oxidative stress due to hydrogen peroxide generation. Titanium discs subjected to the plasma treatment induced less oxidative stress than the untreated ones, which resulted in improved cellular ability. Our data suggest that plasma treated titanium may be a more biocompatible biomaterial.
id UFRN_13faddb387017135097564242edfe0f2
oai_identifier_str oai:https://repositorio.ufrn.br:123456789/12591
network_acronym_str UFRN
network_name_str Repositório Institucional da UFRN
repository_id_str
spelling Queiroz, Jana Dara Freires dehttp://lattes.cnpq.br/8506299133324434http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4781004Y8Bressel, Tatiana Azevedo Bastianhttp://lattes.cnpq.br/6481010060472030Cota, Renata Guerra de Sáhttp://lattes.cnpq.br/0707635962488663Medeiros, Sílvia Regina Batistuzzo de2014-12-17T14:03:39Z2012-08-082014-12-17T14:03:39Z2011-11-29QUEIROZ, Jana Dara Freires de. Avaliação do estresse oxidativo induzido por superfícies de titânio. 2011. 126 f. Dissertação (Mestrado em Bioquímica; Biologia Molecular) - Universidade Federal do Rio Grande do Norte, Natal, 2011.https://repositorio.ufrn.br/jspui/handle/123456789/12591Commercially pure Titanium (cp Ti) is a material largely used in orthopedic and dental implants due to its biocompatibility properties. Changes in the surface of cp Ti can determine the functional response of the cells such as facilitating implant fixation and stabilization, and increased roughness of the surface has been shown to improve adhesion and cellular proliferation. Various surface modification methods have been developed to increase roughness, such as mechanical, chemical, electrochemical and plasma treatment. An argon plasma treatment generates a surface that has good mechanical proprieties without chemical composition modification. Besides the topography, biological responses to the implant contribute significantly to its success. Oxidative stress induced by the biomaterials is considered one of the major causes of implant failure. For this reason the oxidative potential of titanium surfaces subjected to plasma treatment was evaluated on this work. CHO-k1 cells were cultivated on smooth or roughed Ti disks, and after three days, the redox balance was investigated measuring reactive oxygen species (ROS) generation, total antioxidant capacity and biomarkers of ROS attack. The results showed cells grown on titanium surfaces are subjected to intracellular oxidative stress due to hydrogen peroxide generation. Titanium discs subjected to the plasma treatment induced less oxidative stress than the untreated ones, which resulted in improved cellular ability. Our data suggest that plasma treated titanium may be a more biocompatible biomaterial.O Titânio comercialmente puro (cpTi) é amplamente utilizado em implantes ortopédicos e dentais graças às suas propriedades físico-químicas. Mudanças na superfície do cpTi podem determinar respostas funcionais nas células influenciando a fixação e estabilização do implante. Muitos métodos de modificação na superfície podem ser aplicados para aumentar a rugosidade como, por exemplo, tratamentos mecânicos, químicos, eletroquímicos e a plasma. Este último, quando realizado em atmosfera de argônio gera uma superfície rugosa com boas propriedades mecânicas sem alterar a composição química do material. Superfícies rugosas geralmente são mais biocompatíveis que as lisas, pois esse tipo de topografia facilita os processos de adesão e proliferação celular. Além da topografia, as reações biológicas desencadeadas em resposta ao implante contribuem de forma significativa para o sucesso do mesmo. Dentre estas reações, o estresse oxidativo tem sido apontado como um dos principais responsáveis por falhas na implantação. Diante do exposto, o potencial oxidativo das superfícies de titânio tratadas e não tratadas a plasma em atmosfera de argônio foi avaliado neste trabalho. Para tanto, células CHOk1 foram cultivadas sobre as superfícies de titânio (tratadas e não tratadas). Após três dias de cultivo o potencial oxidativo foi investigado por meio da quantificação de espécies reativas, análise da capacidade antioxidante e análise de biomarcadores de dano oxidativo (lipoperoxidação, carbonilação protéica e oxidação das bases do DNA). Os resultados obtidos indicam que ambas as superfícies de titânio induzem estresse oxidativo, sendo o peróxido de hidrogênio a principal espécie envolvida. O tratamento a plasma reduziu os danos oxidativos e promoveu melhora na habilidade celular em responder ao estresse oxidativo. Deste modo, a modificação da superfície de titânio através do tratamento a plasma pode ser uma alternativa para a obtenção de um material com melhor biocompatibilidade.2019-01-15application/pdfporUniversidade Federal do Rio Grande do NortePrograma de Pós-Graduação em BioquímicaUFRNBRBioquímica; Biologia MolecularBiomaterialTitânioPlasma de argônioEstresse oxidativo.BiomaterialTitaniumPlasma treatmentOxidative stress.CNPQ::CIENCIAS BIOLOGICAS::BIOQUIMICAAvaliação do estresse oxidativo induzido por superfícies de titânioinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFRNinstname:Universidade Federal do Rio Grande do Norte (UFRN)instacron:UFRNORIGINALAvaliacaoEstresseOxidativo_Queiroz_2011.pdfAvaliacaoEstresseOxidativo_Queiroz_2011.pdfapplication/pdf1850683https://repositorio.ufrn.br/bitstream/123456789/12591/3/AvaliacaoEstresseOxidativo_Queiroz_2011.pdfe5171a51c7f0d0df9cc94a873195a0f7MD53TEXTJanaDFQ_DISSERT.pdf.txtJanaDFQ_DISSERT.pdf.txtExtracted texttext/plain137542https://repositorio.ufrn.br/bitstream/123456789/12591/14/JanaDFQ_DISSERT.pdf.txt639209f92946ec02ecf7bca64ad9dbddMD514AvaliacaoEstresseOxidativo_Queiroz_2011.pdf.txtAvaliacaoEstresseOxidativo_Queiroz_2011.pdf.txtExtracted texttext/plain137542https://repositorio.ufrn.br/bitstream/123456789/12591/16/AvaliacaoEstresseOxidativo_Queiroz_2011.pdf.txt639209f92946ec02ecf7bca64ad9dbddMD516THUMBNAILJanaDFQ_DISSERT.pdf.jpgJanaDFQ_DISSERT.pdf.jpgIM Thumbnailimage/jpeg2911https://repositorio.ufrn.br/bitstream/123456789/12591/15/JanaDFQ_DISSERT.pdf.jpgebe89f4d358f69f3ea73a87d45340629MD515AvaliacaoEstresseOxidativo_Queiroz_2011.pdf.jpgAvaliacaoEstresseOxidativo_Queiroz_2011.pdf.jpgIM Thumbnailimage/jpeg2911https://repositorio.ufrn.br/bitstream/123456789/12591/17/AvaliacaoEstresseOxidativo_Queiroz_2011.pdf.jpgebe89f4d358f69f3ea73a87d45340629MD517123456789/125912024-03-19 01:02:56.071oai:https://repositorio.ufrn.br:123456789/12591Repositório de PublicaçõesPUBhttp://repositorio.ufrn.br/oai/opendoar:2024-03-19T04:02:56Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)false
dc.title.por.fl_str_mv Avaliação do estresse oxidativo induzido por superfícies de titânio
title Avaliação do estresse oxidativo induzido por superfícies de titânio
spellingShingle Avaliação do estresse oxidativo induzido por superfícies de titânio
Queiroz, Jana Dara Freires de
Biomaterial
Titânio
Plasma de argônio
Estresse oxidativo.
Biomaterial
Titanium
Plasma treatment
Oxidative stress.
CNPQ::CIENCIAS BIOLOGICAS::BIOQUIMICA
title_short Avaliação do estresse oxidativo induzido por superfícies de titânio
title_full Avaliação do estresse oxidativo induzido por superfícies de titânio
title_fullStr Avaliação do estresse oxidativo induzido por superfícies de titânio
title_full_unstemmed Avaliação do estresse oxidativo induzido por superfícies de titânio
title_sort Avaliação do estresse oxidativo induzido por superfícies de titânio
author Queiroz, Jana Dara Freires de
author_facet Queiroz, Jana Dara Freires de
author_role author
dc.contributor.authorID.por.fl_str_mv
dc.contributor.authorLattes.por.fl_str_mv http://lattes.cnpq.br/8506299133324434
dc.contributor.advisorID.por.fl_str_mv
dc.contributor.advisorLattes.por.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4781004Y8
dc.contributor.referees1.pt_BR.fl_str_mv Bressel, Tatiana Azevedo Bastian
dc.contributor.referees1ID.por.fl_str_mv
dc.contributor.referees1Lattes.por.fl_str_mv http://lattes.cnpq.br/6481010060472030
dc.contributor.referees2.pt_BR.fl_str_mv Cota, Renata Guerra de Sá
dc.contributor.referees2ID.por.fl_str_mv
dc.contributor.referees2Lattes.por.fl_str_mv http://lattes.cnpq.br/0707635962488663
dc.contributor.author.fl_str_mv Queiroz, Jana Dara Freires de
dc.contributor.advisor1.fl_str_mv Medeiros, Sílvia Regina Batistuzzo de
contributor_str_mv Medeiros, Sílvia Regina Batistuzzo de
dc.subject.por.fl_str_mv Biomaterial
Titânio
Plasma de argônio
Estresse oxidativo.
topic Biomaterial
Titânio
Plasma de argônio
Estresse oxidativo.
Biomaterial
Titanium
Plasma treatment
Oxidative stress.
CNPQ::CIENCIAS BIOLOGICAS::BIOQUIMICA
dc.subject.eng.fl_str_mv Biomaterial
Titanium
Plasma treatment
Oxidative stress.
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS BIOLOGICAS::BIOQUIMICA
description Commercially pure Titanium (cp Ti) is a material largely used in orthopedic and dental implants due to its biocompatibility properties. Changes in the surface of cp Ti can determine the functional response of the cells such as facilitating implant fixation and stabilization, and increased roughness of the surface has been shown to improve adhesion and cellular proliferation. Various surface modification methods have been developed to increase roughness, such as mechanical, chemical, electrochemical and plasma treatment. An argon plasma treatment generates a surface that has good mechanical proprieties without chemical composition modification. Besides the topography, biological responses to the implant contribute significantly to its success. Oxidative stress induced by the biomaterials is considered one of the major causes of implant failure. For this reason the oxidative potential of titanium surfaces subjected to plasma treatment was evaluated on this work. CHO-k1 cells were cultivated on smooth or roughed Ti disks, and after three days, the redox balance was investigated measuring reactive oxygen species (ROS) generation, total antioxidant capacity and biomarkers of ROS attack. The results showed cells grown on titanium surfaces are subjected to intracellular oxidative stress due to hydrogen peroxide generation. Titanium discs subjected to the plasma treatment induced less oxidative stress than the untreated ones, which resulted in improved cellular ability. Our data suggest that plasma treated titanium may be a more biocompatible biomaterial.
publishDate 2011
dc.date.issued.fl_str_mv 2011-11-29
dc.date.available.fl_str_mv 2012-08-08
2014-12-17T14:03:39Z
dc.date.accessioned.fl_str_mv 2014-12-17T14:03:39Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv QUEIROZ, Jana Dara Freires de. Avaliação do estresse oxidativo induzido por superfícies de titânio. 2011. 126 f. Dissertação (Mestrado em Bioquímica; Biologia Molecular) - Universidade Federal do Rio Grande do Norte, Natal, 2011.
dc.identifier.uri.fl_str_mv https://repositorio.ufrn.br/jspui/handle/123456789/12591
identifier_str_mv QUEIROZ, Jana Dara Freires de. Avaliação do estresse oxidativo induzido por superfícies de titânio. 2011. 126 f. Dissertação (Mestrado em Bioquímica; Biologia Molecular) - Universidade Federal do Rio Grande do Norte, Natal, 2011.
url https://repositorio.ufrn.br/jspui/handle/123456789/12591
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal do Rio Grande do Norte
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Bioquímica
dc.publisher.initials.fl_str_mv UFRN
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Bioquímica; Biologia Molecular
publisher.none.fl_str_mv Universidade Federal do Rio Grande do Norte
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFRN
instname:Universidade Federal do Rio Grande do Norte (UFRN)
instacron:UFRN
instname_str Universidade Federal do Rio Grande do Norte (UFRN)
instacron_str UFRN
institution UFRN
reponame_str Repositório Institucional da UFRN
collection Repositório Institucional da UFRN
bitstream.url.fl_str_mv https://repositorio.ufrn.br/bitstream/123456789/12591/3/AvaliacaoEstresseOxidativo_Queiroz_2011.pdf
https://repositorio.ufrn.br/bitstream/123456789/12591/14/JanaDFQ_DISSERT.pdf.txt
https://repositorio.ufrn.br/bitstream/123456789/12591/16/AvaliacaoEstresseOxidativo_Queiroz_2011.pdf.txt
https://repositorio.ufrn.br/bitstream/123456789/12591/15/JanaDFQ_DISSERT.pdf.jpg
https://repositorio.ufrn.br/bitstream/123456789/12591/17/AvaliacaoEstresseOxidativo_Queiroz_2011.pdf.jpg
bitstream.checksum.fl_str_mv e5171a51c7f0d0df9cc94a873195a0f7
639209f92946ec02ecf7bca64ad9dbdd
639209f92946ec02ecf7bca64ad9dbdd
ebe89f4d358f69f3ea73a87d45340629
ebe89f4d358f69f3ea73a87d45340629
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)
repository.mail.fl_str_mv
_version_ 1814832746432823296