Perturbative measurement of magnetoresistance

Detalhes bibliográficos
Autor(a) principal: Oliveira, Alexandre Barbosa de
Data de Publicação: 2018
Outros Autores: Melo, A. C. C., Costa, R. B., Costa, N. P., Azevedo, A., Feitosa, Carlos Chesman de Araújo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UFRN
Texto Completo: https://repositorio.ufrn.br/jspui/handle/123456789/28836
https://doi.org/10.1063/1.5047661
Resumo: In this paper, we report the development of a novel technique in which the magnetoresistance of nanostructures is perturbatively measured by transversally modulating the DC magnetic field. It measures the electrical transport counterpart of the transverse magnetic AC-susceptibility. The technique was developed in a conventional four-probe configuration in which a small DC current flows through the sample and a small transverse AC-field perturbates the equilibrium position of the sample magnetization. Lock-in detection, in-phase with the AC-perturbation, is used to measure the voltage signal between the two inner electrodes of the four-probe station. We successfully demonstrated that this signal is proportional to the product of the first derivative of sample resistance with respect to the equilibrium position of the magnetization times the second derivative of the energy with respect to the equilibrium position of the magnetization. These dependences add new features to the technique investigated here that were not captured by the investigations previously reported on the same subject. To show the effective use of the technique, we discuss its application in measuring magnetic properties of thin magnetic films in the non-saturated regime.
id UFRN_5743d53eccf25b1a88f7204f85b708e3
oai_identifier_str oai:https://repositorio.ufrn.br:123456789/28836
network_acronym_str UFRN
network_name_str Repositório Institucional da UFRN
repository_id_str
spelling Oliveira, Alexandre Barbosa deMelo, A. C. C.Costa, R. B.Costa, N. P.Azevedo, A.Feitosa, Carlos Chesman de Araújo2020-04-29T20:18:56Z2020-04-29T20:18:56Z2018-12-21OLIVEIRA, Alexandre Barbosa de et al. Perturbative measurement of magnetoresistance. Review of Scientific Instruments, v. 89, p. 125115, 2018. ISSN 1089-7623 versão online. DOI https://doi.org/10.1063/1.5047661. Disponível em: https://aip.scitation.org/doi/10.1063/1.5047661. Acesso em: 29 abr. 2020.0034-6748 (print), 1089-7623 (online)https://repositorio.ufrn.br/jspui/handle/123456789/28836https://doi.org/10.1063/1.5047661AIP PublishingPerturbative measurementMagnetoresistancePerturbative measurement of magnetoresistanceinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleIn this paper, we report the development of a novel technique in which the magnetoresistance of nanostructures is perturbatively measured by transversally modulating the DC magnetic field. It measures the electrical transport counterpart of the transverse magnetic AC-susceptibility. The technique was developed in a conventional four-probe configuration in which a small DC current flows through the sample and a small transverse AC-field perturbates the equilibrium position of the sample magnetization. Lock-in detection, in-phase with the AC-perturbation, is used to measure the voltage signal between the two inner electrodes of the four-probe station. We successfully demonstrated that this signal is proportional to the product of the first derivative of sample resistance with respect to the equilibrium position of the magnetization times the second derivative of the energy with respect to the equilibrium position of the magnetization. These dependences add new features to the technique investigated here that were not captured by the investigations previously reported on the same subject. To show the effective use of the technique, we discuss its application in measuring magnetic properties of thin magnetic films in the non-saturated regime.engreponame:Repositório Institucional da UFRNinstname:Universidade Federal do Rio Grande do Norte (UFRN)instacron:UFRNinfo:eu-repo/semantics/openAccessORIGINALPerturbative measurement of magnetoresistance_oliveira_2018.pdfPerturbative measurement of magnetoresistance_oliveira_2018.pdfapplication/pdf1968435https://repositorio.ufrn.br/bitstream/123456789/28836/1/Perturbative%20measurement%20of%20magnetoresistance_oliveira_2018.pdf0e89a3ac006c152c876d0c18b3792f0eMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81484https://repositorio.ufrn.br/bitstream/123456789/28836/2/license.txte9597aa2854d128fd968be5edc8a28d9MD52TEXTPerturbative measurement of magnetoresistance_oliveira_2018.pdf.txtPerturbative measurement of magnetoresistance_oliveira_2018.pdf.txtExtracted texttext/plain29343https://repositorio.ufrn.br/bitstream/123456789/28836/3/Perturbative%20measurement%20of%20magnetoresistance_oliveira_2018.pdf.txt4d1158e350d24ee30db245e8518f72b1MD53THUMBNAILPerturbative measurement of magnetoresistance_oliveira_2018.pdf.jpgPerturbative measurement of magnetoresistance_oliveira_2018.pdf.jpgGenerated Thumbnailimage/jpeg1824https://repositorio.ufrn.br/bitstream/123456789/28836/4/Perturbative%20measurement%20of%20magnetoresistance_oliveira_2018.pdf.jpgff1775b911972a46162dd6e8a11ec0d8MD54123456789/288362020-06-18 17:26:22.973oai:https://repositorio.ufrn.br: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Repositório de PublicaçõesPUBhttp://repositorio.ufrn.br/oai/opendoar:2020-06-18T20:26:22Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)false
dc.title.pt_BR.fl_str_mv Perturbative measurement of magnetoresistance
title Perturbative measurement of magnetoresistance
spellingShingle Perturbative measurement of magnetoresistance
Oliveira, Alexandre Barbosa de
Perturbative measurement
Magnetoresistance
title_short Perturbative measurement of magnetoresistance
title_full Perturbative measurement of magnetoresistance
title_fullStr Perturbative measurement of magnetoresistance
title_full_unstemmed Perturbative measurement of magnetoresistance
title_sort Perturbative measurement of magnetoresistance
author Oliveira, Alexandre Barbosa de
author_facet Oliveira, Alexandre Barbosa de
Melo, A. C. C.
Costa, R. B.
Costa, N. P.
Azevedo, A.
Feitosa, Carlos Chesman de Araújo
author_role author
author2 Melo, A. C. C.
Costa, R. B.
Costa, N. P.
Azevedo, A.
Feitosa, Carlos Chesman de Araújo
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Oliveira, Alexandre Barbosa de
Melo, A. C. C.
Costa, R. B.
Costa, N. P.
Azevedo, A.
Feitosa, Carlos Chesman de Araújo
dc.subject.por.fl_str_mv Perturbative measurement
Magnetoresistance
topic Perturbative measurement
Magnetoresistance
description In this paper, we report the development of a novel technique in which the magnetoresistance of nanostructures is perturbatively measured by transversally modulating the DC magnetic field. It measures the electrical transport counterpart of the transverse magnetic AC-susceptibility. The technique was developed in a conventional four-probe configuration in which a small DC current flows through the sample and a small transverse AC-field perturbates the equilibrium position of the sample magnetization. Lock-in detection, in-phase with the AC-perturbation, is used to measure the voltage signal between the two inner electrodes of the four-probe station. We successfully demonstrated that this signal is proportional to the product of the first derivative of sample resistance with respect to the equilibrium position of the magnetization times the second derivative of the energy with respect to the equilibrium position of the magnetization. These dependences add new features to the technique investigated here that were not captured by the investigations previously reported on the same subject. To show the effective use of the technique, we discuss its application in measuring magnetic properties of thin magnetic films in the non-saturated regime.
publishDate 2018
dc.date.issued.fl_str_mv 2018-12-21
dc.date.accessioned.fl_str_mv 2020-04-29T20:18:56Z
dc.date.available.fl_str_mv 2020-04-29T20:18:56Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.citation.fl_str_mv OLIVEIRA, Alexandre Barbosa de et al. Perturbative measurement of magnetoresistance. Review of Scientific Instruments, v. 89, p. 125115, 2018. ISSN 1089-7623 versão online. DOI https://doi.org/10.1063/1.5047661. Disponível em: https://aip.scitation.org/doi/10.1063/1.5047661. Acesso em: 29 abr. 2020.
dc.identifier.uri.fl_str_mv https://repositorio.ufrn.br/jspui/handle/123456789/28836
dc.identifier.issn.none.fl_str_mv 0034-6748 (print), 1089-7623 (online)
dc.identifier.doi.none.fl_str_mv https://doi.org/10.1063/1.5047661
identifier_str_mv OLIVEIRA, Alexandre Barbosa de et al. Perturbative measurement of magnetoresistance. Review of Scientific Instruments, v. 89, p. 125115, 2018. ISSN 1089-7623 versão online. DOI https://doi.org/10.1063/1.5047661. Disponível em: https://aip.scitation.org/doi/10.1063/1.5047661. Acesso em: 29 abr. 2020.
0034-6748 (print), 1089-7623 (online)
url https://repositorio.ufrn.br/jspui/handle/123456789/28836
https://doi.org/10.1063/1.5047661
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv AIP Publishing
publisher.none.fl_str_mv AIP Publishing
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFRN
instname:Universidade Federal do Rio Grande do Norte (UFRN)
instacron:UFRN
instname_str Universidade Federal do Rio Grande do Norte (UFRN)
instacron_str UFRN
institution UFRN
reponame_str Repositório Institucional da UFRN
collection Repositório Institucional da UFRN
bitstream.url.fl_str_mv https://repositorio.ufrn.br/bitstream/123456789/28836/1/Perturbative%20measurement%20of%20magnetoresistance_oliveira_2018.pdf
https://repositorio.ufrn.br/bitstream/123456789/28836/2/license.txt
https://repositorio.ufrn.br/bitstream/123456789/28836/3/Perturbative%20measurement%20of%20magnetoresistance_oliveira_2018.pdf.txt
https://repositorio.ufrn.br/bitstream/123456789/28836/4/Perturbative%20measurement%20of%20magnetoresistance_oliveira_2018.pdf.jpg
bitstream.checksum.fl_str_mv 0e89a3ac006c152c876d0c18b3792f0e
e9597aa2854d128fd968be5edc8a28d9
4d1158e350d24ee30db245e8518f72b1
ff1775b911972a46162dd6e8a11ec0d8
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)
repository.mail.fl_str_mv
_version_ 1814832721011146752