Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam

Detalhes bibliográficos
Autor(a) principal: Albuquerque Neto, Carlos Morais de
Data de Publicação: 2017
Tipo de documento: Trabalho de conclusão de curso
Idioma: por
Título da fonte: Repositório Institucional da UFRN
Texto Completo: https://repositorio.ufrn.br/handle/123456789/39000
Resumo: CAD/CAM systems are today an important ally to the Dentist and the Prosthodontics Technician in the manufacture of ceramic crowns with greater accuracy and efficiency. With the passing of the years this equipment has been obtaining an increasing adhesion on the part of the Dental professionals. The Purpose of this study was to evaluate the influence of different CAD/CAM systems on the occlusal and interproximal contacts accuracy of ceramic unit crowns. This is a comparative In Vitro study involving 2 groups of 10 crowns of lithium disilicate manufactured from 2 types of scanning, the CEREC BlueCam system and CEREC Apollo DI system. Evaluations of occlusal and interproximal were performed by a previously single trained examiner. For the occlusal contacts accuracy, CEREC BlueCam system presented 90% of the crowns manufactured in lithium disilicate according to the parameter considered “clinically excellent” compared to 30% of the crowns manufactured from CEREC Apollo DI system for the same parameter. Standing this second system with 70% of its manufactured crowns according to the parameter considered “clinically good” to the occlusal contacts accuracy. Concerning the interproximal contacts accuracy there were no significant differences, with CEREC BlueCam system presenting 100% of the manufactured crowns according to the parameter considered “clinically excellent” compared to 80% of the crowns manufactured by CEREC Apollo DI system for the same parameter. Within the limitations of the study, it can be concluded that, for the aspects of occlusal contacts accuracy and interproximal contacts accuracy, CEREC BlueCam system was superior than CEREC Apollo DI system.
id UFRN_897f0f11bd2fd235d1d70444c1780bf2
oai_identifier_str oai:https://repositorio.ufrn.br:123456789/39000
network_acronym_str UFRN
network_name_str Repositório Institucional da UFRN
repository_id_str
spelling Albuquerque Neto, Carlos Morais deBARBOSA, Gustavo Augusto SeabraALMEIDA, Érika Oliveira deRESENDE, Camila Maria Bastos Machado deBarbosa, Gustavo Augusto Seabra2017-10-02T13:09:53Z2021-09-27T14:01:52Z2017-10-02T13:09:53Z2021-09-27T14:01:52Z2017-06-192013040704ALBUQUERQUE NETO, Carlos Morais de. Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam. 2017. Monografia (Graduação) - Departamento de Odontologia, Universidade Federal do Rio Grande do Norte, Natal, 2017.https://repositorio.ufrn.br/handle/123456789/39000CAD/CAM systems are today an important ally to the Dentist and the Prosthodontics Technician in the manufacture of ceramic crowns with greater accuracy and efficiency. With the passing of the years this equipment has been obtaining an increasing adhesion on the part of the Dental professionals. The Purpose of this study was to evaluate the influence of different CAD/CAM systems on the occlusal and interproximal contacts accuracy of ceramic unit crowns. This is a comparative In Vitro study involving 2 groups of 10 crowns of lithium disilicate manufactured from 2 types of scanning, the CEREC BlueCam system and CEREC Apollo DI system. Evaluations of occlusal and interproximal were performed by a previously single trained examiner. For the occlusal contacts accuracy, CEREC BlueCam system presented 90% of the crowns manufactured in lithium disilicate according to the parameter considered “clinically excellent” compared to 30% of the crowns manufactured from CEREC Apollo DI system for the same parameter. Standing this second system with 70% of its manufactured crowns according to the parameter considered “clinically good” to the occlusal contacts accuracy. Concerning the interproximal contacts accuracy there were no significant differences, with CEREC BlueCam system presenting 100% of the manufactured crowns according to the parameter considered “clinically excellent” compared to 80% of the crowns manufactured by CEREC Apollo DI system for the same parameter. Within the limitations of the study, it can be concluded that, for the aspects of occlusal contacts accuracy and interproximal contacts accuracy, CEREC BlueCam system was superior than CEREC Apollo DI system.Os sistemas CAD/CAM são hoje um importante aliado ao Cirurgião Dentista e o Técnico em Prótese Dentária na confecção de coroas em cerâmica com maior precisão e eficácia. Com o passar dos anos estes equipamentos vem obtendo uma crescente adesão por parte dos profissionais da área odontológica. O Objetivo desse estudo foi avaliar a influência de diferentes sistemas de CAD/CAM na precisão dos contatos oclusais e interproximais de coroas unitárias cerâmicas. Trata-se de um estudo do tipo In vitro, comparativo envolvendo 2 grupos de 10 coroas de dissilicato de lítio fabricadas a partir de 2 tipos de escaneamento, o sistema CEREC BlueCam e o sistema CEREC Apollo DI. As avaliações dos contatos oclusais e interproximais foram realizadas por um único examinador previamente treinado. Para a precisão dos contatos oclusais, o sistema CEREC BlueCam apresentou 90% das coroas fabricadas em dissilicato de lítio atendendo o parâmetro considerado “clinicamente excelente” frente a 30% das coroas fabricadas a partir do sistema CEREC Apollo DI para o mesmo parâmetro. Ficando esse segundo sistema com 70% de suas coroas fabricadas atendendo ao parâmetro de “clinicamente bom” para a precisão dos contatos oclusais. Já com relação a precisão dos contatos interproximais não houve diferenças, com o sistema CEREC BlueCam apresentando 100% das coroas fabricadas atendendo ao parâmetro de “clinicamente excelente” frente a 80% das coroas fabricadas pelo sistema CEREC Apollo DI para o mesmo parâmetro. Dentro das limitações do estudo, pode-se concluir que, para os aspectos de precisão dos contatos oclusais e precisão dos contatos interproximais, o sistema CEREC BlueCam mostrou-se superior quando comparado ao sistema CEREC Apollo DI.Universidade Federal do Rio Grande do NorteUFRNBrasilOdontologiaSistema CAD/CAMPrecisão dos contatos oclusaisPrecisão dos contatos interproximaisCEREC BlueCAMCEREC Apollo DIInfluência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/caminfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisinfo:eu-repo/semantics/openAccessporreponame:Repositório Institucional da UFRNinstname:Universidade Federal do Rio Grande do Norte (UFRN)instacron:UFRNTEXT[2017.1] Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cadcam..pdf.txtExtracted texttext/plain29889https://repositorio.ufrn.br/bitstream/123456789/39000/1/%5b2017.1%5d%20Influ%c3%aancia%20de%20sistemas%20de%20escaneamento%20na%20precis%c3%a3o%20de%20contatos%20oclusais%20e%20interproximais%20de%20coroas%20cer%c3%a2micas%20obtidas%20por%20tecnologia%20cadcam..pdf.txta919ae7ef6444be9d41b480ff73f644fMD51ORIGINALInfluenciasSistemasEscaneamento_Albuquerque_2017.pdfTrabalho de conclusão de curso - odontologia 2017.1application/pdf883101https://repositorio.ufrn.br/bitstream/123456789/39000/2/InfluenciasSistemasEscaneamento_Albuquerque_2017.pdf85e51f861b439d4547512ae0b03714dcMD52LICENSElicense.txttext/plain756https://repositorio.ufrn.br/bitstream/123456789/39000/3/license.txta80a9cda2756d355b388cc443c3d8a43MD53123456789/390002023-05-03 10:38:16.936oai:https://repositorio.ufrn.br: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ório de PublicaçõesPUBhttp://repositorio.ufrn.br/oai/opendoar:2023-05-03T13:38:16Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)false
dc.title.pr_BR.fl_str_mv Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
title Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
spellingShingle Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
Albuquerque Neto, Carlos Morais de
Sistema CAD/CAM
Precisão dos contatos oclusais
Precisão dos contatos interproximais
CEREC BlueCAM
CEREC Apollo DI
title_short Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
title_full Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
title_fullStr Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
title_full_unstemmed Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
title_sort Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam
author Albuquerque Neto, Carlos Morais de
author_facet Albuquerque Neto, Carlos Morais de
author_role author
dc.contributor.referees1.none.fl_str_mv BARBOSA, Gustavo Augusto Seabra
dc.contributor.referees2.none.fl_str_mv ALMEIDA, Érika Oliveira de
dc.contributor.referees3.none.fl_str_mv RESENDE, Camila Maria Bastos Machado de
dc.contributor.author.fl_str_mv Albuquerque Neto, Carlos Morais de
dc.contributor.advisor1.fl_str_mv Barbosa, Gustavo Augusto Seabra
contributor_str_mv Barbosa, Gustavo Augusto Seabra
dc.subject.pr_BR.fl_str_mv Sistema CAD/CAM
Precisão dos contatos oclusais
Precisão dos contatos interproximais
CEREC BlueCAM
CEREC Apollo DI
topic Sistema CAD/CAM
Precisão dos contatos oclusais
Precisão dos contatos interproximais
CEREC BlueCAM
CEREC Apollo DI
description CAD/CAM systems are today an important ally to the Dentist and the Prosthodontics Technician in the manufacture of ceramic crowns with greater accuracy and efficiency. With the passing of the years this equipment has been obtaining an increasing adhesion on the part of the Dental professionals. The Purpose of this study was to evaluate the influence of different CAD/CAM systems on the occlusal and interproximal contacts accuracy of ceramic unit crowns. This is a comparative In Vitro study involving 2 groups of 10 crowns of lithium disilicate manufactured from 2 types of scanning, the CEREC BlueCam system and CEREC Apollo DI system. Evaluations of occlusal and interproximal were performed by a previously single trained examiner. For the occlusal contacts accuracy, CEREC BlueCam system presented 90% of the crowns manufactured in lithium disilicate according to the parameter considered “clinically excellent” compared to 30% of the crowns manufactured from CEREC Apollo DI system for the same parameter. Standing this second system with 70% of its manufactured crowns according to the parameter considered “clinically good” to the occlusal contacts accuracy. Concerning the interproximal contacts accuracy there were no significant differences, with CEREC BlueCam system presenting 100% of the manufactured crowns according to the parameter considered “clinically excellent” compared to 80% of the crowns manufactured by CEREC Apollo DI system for the same parameter. Within the limitations of the study, it can be concluded that, for the aspects of occlusal contacts accuracy and interproximal contacts accuracy, CEREC BlueCam system was superior than CEREC Apollo DI system.
publishDate 2017
dc.date.accessioned.fl_str_mv 2017-10-02T13:09:53Z
2021-09-27T14:01:52Z
dc.date.available.fl_str_mv 2017-10-02T13:09:53Z
2021-09-27T14:01:52Z
dc.date.issued.fl_str_mv 2017-06-19
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
status_str publishedVersion
dc.identifier.pr_BR.fl_str_mv 2013040704
dc.identifier.citation.fl_str_mv ALBUQUERQUE NETO, Carlos Morais de. Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam. 2017. Monografia (Graduação) - Departamento de Odontologia, Universidade Federal do Rio Grande do Norte, Natal, 2017.
dc.identifier.uri.fl_str_mv https://repositorio.ufrn.br/handle/123456789/39000
identifier_str_mv 2013040704
ALBUQUERQUE NETO, Carlos Morais de. Influência de sistemas de escaneamento na precisão de contatos oclusais e interproximais de coroas cerâmicas obtidas por tecnologia cad/cam. 2017. Monografia (Graduação) - Departamento de Odontologia, Universidade Federal do Rio Grande do Norte, Natal, 2017.
url https://repositorio.ufrn.br/handle/123456789/39000
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade Federal do Rio Grande do Norte
dc.publisher.initials.fl_str_mv UFRN
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Odontologia
publisher.none.fl_str_mv Universidade Federal do Rio Grande do Norte
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFRN
instname:Universidade Federal do Rio Grande do Norte (UFRN)
instacron:UFRN
instname_str Universidade Federal do Rio Grande do Norte (UFRN)
instacron_str UFRN
institution UFRN
reponame_str Repositório Institucional da UFRN
collection Repositório Institucional da UFRN
bitstream.url.fl_str_mv https://repositorio.ufrn.br/bitstream/123456789/39000/1/%5b2017.1%5d%20Influ%c3%aancia%20de%20sistemas%20de%20escaneamento%20na%20precis%c3%a3o%20de%20contatos%20oclusais%20e%20interproximais%20de%20coroas%20cer%c3%a2micas%20obtidas%20por%20tecnologia%20cadcam..pdf.txt
https://repositorio.ufrn.br/bitstream/123456789/39000/2/InfluenciasSistemasEscaneamento_Albuquerque_2017.pdf
https://repositorio.ufrn.br/bitstream/123456789/39000/3/license.txt
bitstream.checksum.fl_str_mv a919ae7ef6444be9d41b480ff73f644f
85e51f861b439d4547512ae0b03714dc
a80a9cda2756d355b388cc443c3d8a43
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)
repository.mail.fl_str_mv
_version_ 1802117800198668288