Avaliação dos teores de enxofre em amostras de gasolina nas redes de distribuição de combustíveis na cidade de Natal/RN
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Tipo de documento: | Trabalho de conclusão de curso |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFRN |
Texto Completo: | https://repositorio.ufrn.br/handle/123456789/38295 |
Resumo: | The sulfur content in petroleum products is an important variable, since sulfur compounds are associated with problems from storage to distribution. Currently, sulfur levels in fuels have been reduced by government agencies to reduce air pollution. According to ANP Resolution No. 40/2013 the sulfur content must be a maximum of 50 mg/kg. For these and other reasons, one of the means to quantify the sulfur with a high value of course, is by validated methods. The validation of the methodology for fluorescence sulfur determination in the UV region was carried out taking as base to ASTM D5453 for determining the sulfur content in gasoline samples of the ordinary and additive type, distributed at gas stations in the city of Natal, RN. It was used certified reference material for the validation and construction of the curve for reading the collected samples. The method showed a validated after 0.006079 mg/L detection limit, a limit of quantitation of 0.020265 mg/L and a coefficient of determination r2 0.9994 curve. The standard addition recovery tests showing 91.0% were made. The tests showed that the method is selective and reliable but must be used the operating conditions under which the experiments were conducted because the sensitivity parameters, injection and quality of the solvent volume showed significant effects, and the detector sensitivity the most critical factor. The results showed that all samples are in accordance to the sulfur content and other analyzed parameters. It is still observed a tendency of leaded gasoline have higher sulfur content than regular gasoline due to the presence of derivatives of sulfonic acids additives. Thus, it can be concluded that the UV fluorescence technique can be applied to gas samples as well as assist in monitoring the concentrations of sulfur contained in gasoline sold in Natal. |
id |
UFRN_ac042c71401175ae8c747f1842684cd6 |
---|---|
oai_identifier_str |
oai:https://repositorio.ufrn.br:123456789/38295 |
network_acronym_str |
UFRN |
network_name_str |
Repositório Institucional da UFRN |
repository_id_str |
|
spelling |
Costa, Letícia Gracyelle AlexandreLarissa Sobral HilárioCosta, Emily Cintia Tossi de AraújoSilva, Djalma Ribeiro da2016-09-21T19:07:58Z2021-09-27T11:47:09Z2016-09-21T19:07:58Z2021-09-27T11:47:09Z2015-12-17201296059COSTA, Letícia Gracyelle Alexandre. Avaliação dos teores de enxofre em amostras de gasolina nas redes de distribuição de combustíveis na cidade de Natal/RN. 2015. 78f. Trabalho de Conclusão de Curso (Graduação em Química do Petróleo), Instituto de Química, Universidade Federal do Rio Grande do Norte, Natal, 2015.https://repositorio.ufrn.br/handle/123456789/38295The sulfur content in petroleum products is an important variable, since sulfur compounds are associated with problems from storage to distribution. Currently, sulfur levels in fuels have been reduced by government agencies to reduce air pollution. According to ANP Resolution No. 40/2013 the sulfur content must be a maximum of 50 mg/kg. For these and other reasons, one of the means to quantify the sulfur with a high value of course, is by validated methods. The validation of the methodology for fluorescence sulfur determination in the UV region was carried out taking as base to ASTM D5453 for determining the sulfur content in gasoline samples of the ordinary and additive type, distributed at gas stations in the city of Natal, RN. It was used certified reference material for the validation and construction of the curve for reading the collected samples. The method showed a validated after 0.006079 mg/L detection limit, a limit of quantitation of 0.020265 mg/L and a coefficient of determination r2 0.9994 curve. The standard addition recovery tests showing 91.0% were made. The tests showed that the method is selective and reliable but must be used the operating conditions under which the experiments were conducted because the sensitivity parameters, injection and quality of the solvent volume showed significant effects, and the detector sensitivity the most critical factor. The results showed that all samples are in accordance to the sulfur content and other analyzed parameters. It is still observed a tendency of leaded gasoline have higher sulfur content than regular gasoline due to the presence of derivatives of sulfonic acids additives. Thus, it can be concluded that the UV fluorescence technique can be applied to gas samples as well as assist in monitoring the concentrations of sulfur contained in gasoline sold in Natal.O teor de enxofre nos produtos derivados do petróleo é uma variável importante, já que compostos sulfurados são associados a problemas desde o armazenamento até a sua distribuição. Na atualidade, os níveis de enxofre em combustíveis têm sido reduzidos pelos órgãos governamentais para diminuir a poluição do ar. De acordo com a Resolução ANP Nº 40/2013 o teor de enxofre deve ser no máximo de 50 mg/kg. Por estes e outros motivos, um dos meios de quantificar o enxofre com um alto valor de certeza, é através de métodos validados. A validação da metodologia para determinação de enxofre por fluorescência na região do Ultravioleta foi realizada tendo-se como base a norma ASTM D5453, para determinação do teor de enxofre em amostras de gasolina do tipo comum e aditivada, distribuída em postos de combustíveis na cidade de Natal, RN. Foi utilizado material de referência certificado para a validação e construção da curva para a leitura das amostras coletadas. O método depois de validado apresentou um limite de detecção de 0,006079 mg/L, um limite de quantificação de 0,020265 mg/L e um coeficiente de determinação da curva de r2 0,9994. Foram feitos os testes de adição de padrão apresentando recuperação de 91,0%. Os testes mostraram que o método é seletivo e confiável, porém deve ser utilizado as condições operacionais em que os experimentos foram realizados, pois os parâmetros sensibilidade, volume de injeção e qualidade do solvente apresentaram efeitos significativos, sendo a sensibilidade do detector o fator mais crítico. Os resultados mostraram que todas as amostras estão em conformidade para o teor de enxofre e para os outros parâmetros analisados. observa-se ainda uma tendência da gasolina aditivada apresentar um maior teor de enxofre do que a gasolina comum, devido à presença de aditivos derivados de ácidos sulfônicos. Sendo assim, pode-se concluir que a técnica de Fluorescência de Ultravioleta pode ser aplicada à amostras de gasolina, bem como auxiliar no monitoramento das concentrações de enxofre contidas na gasolina comercializada na cidade de Natal.PFRH PB 222Universidade Federal do Rio Grande do NorteUFRNBrasilQuímica do PetróleoGasolinaFluorescência na região do UltravioletaEnxofreGasolineSulphurFluorescence in the ultraviolet regionQuímica do PetróleoAvaliação dos teores de enxofre em amostras de gasolina nas redes de distribuição de combustíveis na cidade de Natal/RNinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisinfo:eu-repo/semantics/openAccessporreponame:Repositório Institucional da UFRNinstname:Universidade Federal do Rio Grande do Norte (UFRN)instacron:UFRNTEXTAvaliacaoTeoresEnxofre_Costa_2015.pdf.txtExtracted texttext/plain131772https://repositorio.ufrn.br/bitstream/123456789/38295/1/AvaliacaoTeoresEnxofre_Costa_2015.pdf.txt01f4caa54168e8a9bfc6a148f88ef937MD51ORIGINALAvaliacaoTeoresEnxofre_Costa_2015.pdfapplication/pdf1605232https://repositorio.ufrn.br/bitstream/123456789/38295/2/AvaliacaoTeoresEnxofre_Costa_2015.pdf10e38c28af268f6adb7c8268a722b960MD52CC-LICENSElicense_urlapplication/octet-stream46https://repositorio.ufrn.br/bitstream/123456789/38295/3/license_url587cd8ffae15c8598ed3c46d248a3f38MD53license_textapplication/octet-stream21809https://repositorio.ufrn.br/bitstream/123456789/38295/4/license_textb1e0d4672cb11319e5d5fd66a3b084b5MD54license_rdfapplication/octet-stream0https://repositorio.ufrn.br/bitstream/123456789/38295/5/license_rdfd41d8cd98f00b204e9800998ecf8427eMD55LICENSElicense.txttext/plain756https://repositorio.ufrn.br/bitstream/123456789/38295/6/license.txta80a9cda2756d355b388cc443c3d8a43MD56123456789/382952023-05-18 09:26:49.971oai:https://repositorio.ufrn.br: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ório de PublicaçõesPUBhttp://repositorio.ufrn.br/oai/opendoar:2023-05-18T12:26:49Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)false |
dc.title.pr_BR.fl_str_mv |
Avaliação dos teores de enxofre em amostras de gasolina nas redes de distribuição de combustíveis na cidade de Natal/RN |
title |
Avaliação dos teores de enxofre em amostras de gasolina nas redes de distribuição de combustíveis na cidade de Natal/RN |
spellingShingle |
Avaliação dos teores de enxofre em amostras de gasolina nas redes de distribuição de combustíveis na cidade de Natal/RN Costa, Letícia Gracyelle Alexandre Gasolina Fluorescência na região do Ultravioleta Enxofre Gasoline Sulphur Fluorescence in the ultraviolet region Química do Petróleo |
title_short |
Avaliação dos teores de enxofre em amostras de gasolina nas redes de distribuição de combustíveis na cidade de Natal/RN |
title_full |
Avaliação dos teores de enxofre em amostras de gasolina nas redes de distribuição de combustíveis na cidade de Natal/RN |
title_fullStr |
Avaliação dos teores de enxofre em amostras de gasolina nas redes de distribuição de combustíveis na cidade de Natal/RN |
title_full_unstemmed |
Avaliação dos teores de enxofre em amostras de gasolina nas redes de distribuição de combustíveis na cidade de Natal/RN |
title_sort |
Avaliação dos teores de enxofre em amostras de gasolina nas redes de distribuição de combustíveis na cidade de Natal/RN |
author |
Costa, Letícia Gracyelle Alexandre |
author_facet |
Costa, Letícia Gracyelle Alexandre |
author_role |
author |
dc.contributor.referees1.none.fl_str_mv |
Costa, Emily Cintia Tossi de Araújo |
dc.contributor.author.fl_str_mv |
Costa, Letícia Gracyelle Alexandre |
dc.contributor.advisor-co1.fl_str_mv |
Larissa Sobral Hilário |
dc.contributor.advisor1.fl_str_mv |
Silva, Djalma Ribeiro da |
contributor_str_mv |
Larissa Sobral Hilário Silva, Djalma Ribeiro da |
dc.subject.pr_BR.fl_str_mv |
Gasolina Fluorescência na região do Ultravioleta Enxofre Gasoline Sulphur Fluorescence in the ultraviolet region |
topic |
Gasolina Fluorescência na região do Ultravioleta Enxofre Gasoline Sulphur Fluorescence in the ultraviolet region Química do Petróleo |
dc.subject.cnpq.fl_str_mv |
Química do Petróleo |
description |
The sulfur content in petroleum products is an important variable, since sulfur compounds are associated with problems from storage to distribution. Currently, sulfur levels in fuels have been reduced by government agencies to reduce air pollution. According to ANP Resolution No. 40/2013 the sulfur content must be a maximum of 50 mg/kg. For these and other reasons, one of the means to quantify the sulfur with a high value of course, is by validated methods. The validation of the methodology for fluorescence sulfur determination in the UV region was carried out taking as base to ASTM D5453 for determining the sulfur content in gasoline samples of the ordinary and additive type, distributed at gas stations in the city of Natal, RN. It was used certified reference material for the validation and construction of the curve for reading the collected samples. The method showed a validated after 0.006079 mg/L detection limit, a limit of quantitation of 0.020265 mg/L and a coefficient of determination r2 0.9994 curve. The standard addition recovery tests showing 91.0% were made. The tests showed that the method is selective and reliable but must be used the operating conditions under which the experiments were conducted because the sensitivity parameters, injection and quality of the solvent volume showed significant effects, and the detector sensitivity the most critical factor. The results showed that all samples are in accordance to the sulfur content and other analyzed parameters. It is still observed a tendency of leaded gasoline have higher sulfur content than regular gasoline due to the presence of derivatives of sulfonic acids additives. Thus, it can be concluded that the UV fluorescence technique can be applied to gas samples as well as assist in monitoring the concentrations of sulfur contained in gasoline sold in Natal. |
publishDate |
2015 |
dc.date.issued.fl_str_mv |
2015-12-17 |
dc.date.accessioned.fl_str_mv |
2016-09-21T19:07:58Z 2021-09-27T11:47:09Z |
dc.date.available.fl_str_mv |
2016-09-21T19:07:58Z 2021-09-27T11:47:09Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
format |
bachelorThesis |
status_str |
publishedVersion |
dc.identifier.pr_BR.fl_str_mv |
201296059 |
dc.identifier.citation.fl_str_mv |
COSTA, Letícia Gracyelle Alexandre. Avaliação dos teores de enxofre em amostras de gasolina nas redes de distribuição de combustíveis na cidade de Natal/RN. 2015. 78f. Trabalho de Conclusão de Curso (Graduação em Química do Petróleo), Instituto de Química, Universidade Federal do Rio Grande do Norte, Natal, 2015. |
dc.identifier.uri.fl_str_mv |
https://repositorio.ufrn.br/handle/123456789/38295 |
identifier_str_mv |
201296059 COSTA, Letícia Gracyelle Alexandre. Avaliação dos teores de enxofre em amostras de gasolina nas redes de distribuição de combustíveis na cidade de Natal/RN. 2015. 78f. Trabalho de Conclusão de Curso (Graduação em Química do Petróleo), Instituto de Química, Universidade Federal do Rio Grande do Norte, Natal, 2015. |
url |
https://repositorio.ufrn.br/handle/123456789/38295 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Universidade Federal do Rio Grande do Norte |
dc.publisher.initials.fl_str_mv |
UFRN |
dc.publisher.country.fl_str_mv |
Brasil |
dc.publisher.department.fl_str_mv |
Química do Petróleo |
publisher.none.fl_str_mv |
Universidade Federal do Rio Grande do Norte |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFRN instname:Universidade Federal do Rio Grande do Norte (UFRN) instacron:UFRN |
instname_str |
Universidade Federal do Rio Grande do Norte (UFRN) |
instacron_str |
UFRN |
institution |
UFRN |
reponame_str |
Repositório Institucional da UFRN |
collection |
Repositório Institucional da UFRN |
bitstream.url.fl_str_mv |
https://repositorio.ufrn.br/bitstream/123456789/38295/1/AvaliacaoTeoresEnxofre_Costa_2015.pdf.txt https://repositorio.ufrn.br/bitstream/123456789/38295/2/AvaliacaoTeoresEnxofre_Costa_2015.pdf https://repositorio.ufrn.br/bitstream/123456789/38295/3/license_url https://repositorio.ufrn.br/bitstream/123456789/38295/4/license_text https://repositorio.ufrn.br/bitstream/123456789/38295/5/license_rdf https://repositorio.ufrn.br/bitstream/123456789/38295/6/license.txt |
bitstream.checksum.fl_str_mv |
01f4caa54168e8a9bfc6a148f88ef937 10e38c28af268f6adb7c8268a722b960 587cd8ffae15c8598ed3c46d248a3f38 b1e0d4672cb11319e5d5fd66a3b084b5 d41d8cd98f00b204e9800998ecf8427e a80a9cda2756d355b388cc443c3d8a43 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN) |
repository.mail.fl_str_mv |
|
_version_ |
1802117521973706752 |