Uma janela tropical: análise do desempenho luminoso de ambientes com aberturas sombreadas para o clima de Natal/RN

Detalhes bibliográficos
Autor(a) principal: Araújo, Juliana de Sá
Data de Publicação: 2012
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFRN
Texto Completo: https://repositorio.ufrn.br/jspui/handle/123456789/12375
Resumo: This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential
id UFRN_be100b6041b61e250a063be44f2864c4
oai_identifier_str oai:https://repositorio.ufrn.br:123456789/12375
network_acronym_str UFRN
network_name_str Repositório Institucional da UFRN
repository_id_str
spelling Araújo, Juliana de Sáhttp://lattes.cnpq.br/7305922773348169http://lattes.cnpq.br/9012296636400514Cabús, Ricardo Carvalhohttp://lattes.cnpq.br/1150075301427239Leder, Solange MariaÚltima atualização do currículo em 14/10/2009Goulart, Solange Virgínia Galarcahttp://lattes.cnpq.br/3736189855910739Pedrini, Aldomar2014-12-17T13:57:08Z2012-11-192014-12-17T13:57:08Z2012-02-27ARAÚJO, Juliana de Sá. Uma janela tropical: análise do desempenho luminoso de ambientes com aberturas sombreadas para o clima de Natal/RN. 2012. 136 f. Dissertação (Mestrado em Conforto no Ambiente Construído; Forma Urbana e Habitação) - Universidade Federal do Rio Grande do Norte, Natal, 2012.https://repositorio.ufrn.br/jspui/handle/123456789/12375This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influentialA pesquisa propõe procedimentos de análise do desempenho de iluminação natural em salas de escritório com aberturas sombreadas, para características de céu de Natal/RN (Latitude 05,47' S, Longitude 35,11' W). Os estudos partem da premissa que aberturas em edificações localizadas em clima quente e úmido devem ser sombreadas. As características de céu se baseiam em tratamento estatístico dos registros da estação climatológica e de iluminação natural do INPE-CRN, em Natal/RN. As análises se baseiam no comportamento luminoso dos modelos entre 08h00 e 16h00, com características de pé direito de 2,8 m, largura de 6,0m e com profundidades de 4,0 m, 6,0 m e 8,0 m, com uma abertura única com três frações de tamanho (20%, 40% e 60% de Paf). Foram desenvolvidos dois métodos de simulação dinâmica no programa Troplux (versão 3.12 e versão 5.0), sendo o primeiro com dados monitorados de céu e outro com dados da IES presentes no sistema do programa. São considerados, para o primeiro método de simulação, três níveis de iluminâncias (300, 500 e 1000 lux), quatro orientações (Norte, Leste, Sul e Oeste), e duas condições de céus (claro e parcial). Para as simulações com dados da IES são considerados os três níveis de iluminâncias (300,500 e 1000 lux), duas orientações (Norte e Sul), e três condições de céus (claro, parcial e encoberto). São gerados 72 modelos e 18 modelos respectivamente. Os resultados das simulações foram analisados por meio de um parâmetro de quantificação do aproveitamento de luz natural no ambiente construído denominado percentual útil de luz natural (PULN), que corresponde à fração de tempo com luz suficiente para atender uma determinada iluminância de projeto. A caracterização da profundidade da zona passiva de iluminação natural se baseia no PULN para atendimento das iluminâncias de projeto. Os resultados entre os dois métodos de simulação foram comparados sendo identificado que os dados monitorados de céu coletados na estação solarimétrica apresentam falhas operacionais que limitam a caracterização do tipo de céu. A proposta gráfica de determinação de recomendações empregou os dados de simulação troplux/IES. As variáveis mais influentes no desempenho luminoso são o tamanho da abertura e o nível de iluminância de projeto, enquanto que a orientação da abertura pouco influenciouConselho Nacional de Desenvolvimento Científico e Tecnológicoapplication/pdfporUniversidade Federal do Rio Grande do NortePrograma de Pós-Graduação em Arquitetura e UrbanismoUFRNBRConforto no Ambiente Construído; Forma Urbana e Habitaçãoiluminação naturaleficiência energéticatipo de céudaylightingenergy efficiencysky typeCNPQ::CIENCIAS SOCIAIS APLICADAS::ARQUITETURA E URBANISMOUma janela tropical: análise do desempenho luminoso de ambientes com aberturas sombreadas para o clima de Natal/RNinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFRNinstname:Universidade Federal do Rio Grande do Norte (UFRN)instacron:UFRNORIGINALJanelaTropicalAnálise_Araujo_2012.pdfapplication/pdf4368174https://repositorio.ufrn.br/bitstream/123456789/12375/1/JanelaTropicalAn%c3%a1lise_Araujo_2012.pdf1c4f744379fc80dd647cde4951df73f8MD51TEXTJulianaSA_DISSERT.pdf.txtJulianaSA_DISSERT.pdf.txtExtracted texttext/plain262383https://repositorio.ufrn.br/bitstream/123456789/12375/6/JulianaSA_DISSERT.pdf.txt87563acb0826a2ee7beed684ca9e0c30MD56JanelaTropicalAnálise_Araujo_2012.pdf.txtJanelaTropicalAnálise_Araujo_2012.pdf.txtExtracted texttext/plain262383https://repositorio.ufrn.br/bitstream/123456789/12375/8/JanelaTropicalAn%c3%a1lise_Araujo_2012.pdf.txt87563acb0826a2ee7beed684ca9e0c30MD58THUMBNAILJulianaSA_DISSERT.pdf.jpgJulianaSA_DISSERT.pdf.jpgIM Thumbnailimage/jpeg1954https://repositorio.ufrn.br/bitstream/123456789/12375/7/JulianaSA_DISSERT.pdf.jpg9f113a5b3be872f0db5707e30de55788MD57JanelaTropicalAnálise_Araujo_2012.pdf.jpgJanelaTropicalAnálise_Araujo_2012.pdf.jpgIM Thumbnailimage/jpeg1954https://repositorio.ufrn.br/bitstream/123456789/12375/9/JanelaTropicalAn%c3%a1lise_Araujo_2012.pdf.jpg9f113a5b3be872f0db5707e30de55788MD59123456789/123752019-01-30 05:27:16.722oai:https://repositorio.ufrn.br:123456789/12375Repositório de PublicaçõesPUBhttp://repositorio.ufrn.br/oai/opendoar:2019-01-30T08:27:16Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)false
dc.title.por.fl_str_mv Uma janela tropical: análise do desempenho luminoso de ambientes com aberturas sombreadas para o clima de Natal/RN
title Uma janela tropical: análise do desempenho luminoso de ambientes com aberturas sombreadas para o clima de Natal/RN
spellingShingle Uma janela tropical: análise do desempenho luminoso de ambientes com aberturas sombreadas para o clima de Natal/RN
Araújo, Juliana de Sá
iluminação natural
eficiência energética
tipo de céu
daylighting
energy efficiency
sky type
CNPQ::CIENCIAS SOCIAIS APLICADAS::ARQUITETURA E URBANISMO
title_short Uma janela tropical: análise do desempenho luminoso de ambientes com aberturas sombreadas para o clima de Natal/RN
title_full Uma janela tropical: análise do desempenho luminoso de ambientes com aberturas sombreadas para o clima de Natal/RN
title_fullStr Uma janela tropical: análise do desempenho luminoso de ambientes com aberturas sombreadas para o clima de Natal/RN
title_full_unstemmed Uma janela tropical: análise do desempenho luminoso de ambientes com aberturas sombreadas para o clima de Natal/RN
title_sort Uma janela tropical: análise do desempenho luminoso de ambientes com aberturas sombreadas para o clima de Natal/RN
author Araújo, Juliana de Sá
author_facet Araújo, Juliana de Sá
author_role author
dc.contributor.authorID.por.fl_str_mv
dc.contributor.authorLattes.por.fl_str_mv http://lattes.cnpq.br/7305922773348169
dc.contributor.advisorID.por.fl_str_mv
dc.contributor.advisorLattes.por.fl_str_mv http://lattes.cnpq.br/9012296636400514
dc.contributor.referees1.pt_BR.fl_str_mv Cabús, Ricardo Carvalho
dc.contributor.referees1ID.por.fl_str_mv
dc.contributor.referees1Lattes.por.fl_str_mv http://lattes.cnpq.br/1150075301427239
dc.contributor.referees2.pt_BR.fl_str_mv Leder, Solange Maria
dc.contributor.referees2ID.por.fl_str_mv
dc.contributor.referees2Lattes.por.fl_str_mv Última atualização do currículo em 14/10/2009
dc.contributor.referees3.pt_BR.fl_str_mv Goulart, Solange Virgínia Galarca
dc.contributor.referees3ID.por.fl_str_mv
dc.contributor.referees3Lattes.por.fl_str_mv http://lattes.cnpq.br/3736189855910739
dc.contributor.author.fl_str_mv Araújo, Juliana de Sá
dc.contributor.advisor1.fl_str_mv Pedrini, Aldomar
contributor_str_mv Pedrini, Aldomar
dc.subject.por.fl_str_mv iluminação natural
eficiência energética
tipo de céu
topic iluminação natural
eficiência energética
tipo de céu
daylighting
energy efficiency
sky type
CNPQ::CIENCIAS SOCIAIS APLICADAS::ARQUITETURA E URBANISMO
dc.subject.eng.fl_str_mv daylighting
energy efficiency
sky type
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS SOCIAIS APLICADAS::ARQUITETURA E URBANISMO
description This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential
publishDate 2012
dc.date.available.fl_str_mv 2012-11-19
2014-12-17T13:57:08Z
dc.date.issued.fl_str_mv 2012-02-27
dc.date.accessioned.fl_str_mv 2014-12-17T13:57:08Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv ARAÚJO, Juliana de Sá. Uma janela tropical: análise do desempenho luminoso de ambientes com aberturas sombreadas para o clima de Natal/RN. 2012. 136 f. Dissertação (Mestrado em Conforto no Ambiente Construído; Forma Urbana e Habitação) - Universidade Federal do Rio Grande do Norte, Natal, 2012.
dc.identifier.uri.fl_str_mv https://repositorio.ufrn.br/jspui/handle/123456789/12375
identifier_str_mv ARAÚJO, Juliana de Sá. Uma janela tropical: análise do desempenho luminoso de ambientes com aberturas sombreadas para o clima de Natal/RN. 2012. 136 f. Dissertação (Mestrado em Conforto no Ambiente Construído; Forma Urbana e Habitação) - Universidade Federal do Rio Grande do Norte, Natal, 2012.
url https://repositorio.ufrn.br/jspui/handle/123456789/12375
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal do Rio Grande do Norte
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Arquitetura e Urbanismo
dc.publisher.initials.fl_str_mv UFRN
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Conforto no Ambiente Construído; Forma Urbana e Habitação
publisher.none.fl_str_mv Universidade Federal do Rio Grande do Norte
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFRN
instname:Universidade Federal do Rio Grande do Norte (UFRN)
instacron:UFRN
instname_str Universidade Federal do Rio Grande do Norte (UFRN)
instacron_str UFRN
institution UFRN
reponame_str Repositório Institucional da UFRN
collection Repositório Institucional da UFRN
bitstream.url.fl_str_mv https://repositorio.ufrn.br/bitstream/123456789/12375/1/JanelaTropicalAn%c3%a1lise_Araujo_2012.pdf
https://repositorio.ufrn.br/bitstream/123456789/12375/6/JulianaSA_DISSERT.pdf.txt
https://repositorio.ufrn.br/bitstream/123456789/12375/8/JanelaTropicalAn%c3%a1lise_Araujo_2012.pdf.txt
https://repositorio.ufrn.br/bitstream/123456789/12375/7/JulianaSA_DISSERT.pdf.jpg
https://repositorio.ufrn.br/bitstream/123456789/12375/9/JanelaTropicalAn%c3%a1lise_Araujo_2012.pdf.jpg
bitstream.checksum.fl_str_mv 1c4f744379fc80dd647cde4951df73f8
87563acb0826a2ee7beed684ca9e0c30
87563acb0826a2ee7beed684ca9e0c30
9f113a5b3be872f0db5707e30de55788
9f113a5b3be872f0db5707e30de55788
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)
repository.mail.fl_str_mv
_version_ 1802117713077731328