New methodology for evaluation of non-pilot relay distance protection
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UFRN |
Texto Completo: | https://repositorio.ufrn.br/jspui/handle/123456789/29809 |
Resumo: | Distance relays are typically used in transmission line protection. Their accuracy depends on the correct relay parameterization, phasor estimators, and correct usage of distance characteristics. Identifying suitable relay parameterization and algorithms considering multiple transmission line with various topologies and different fault types is a hard task. Here, a methodology based on the relay trip performance is proposed to evaluate all the main concerns of distance protection such as: maloperation trips per relay units in each fault type, overreach operation, and maloperation due to faults closer to the relay. The methodology could identify the best phasor estimators and distance configurations among those evaluated, as well as it could verify the power system topologies which yield in challenges for distance protection. The results achieved by the proposed methodology demonstrated that it can be useful for assisting the development of phasor estimators and new distance characteristics, as well as for setting existing distance protection in specific power system topologies |
id |
UFRN_e8c66f82bca7f176bb55896f54d2d256 |
---|---|
oai_identifier_str |
oai:https://repositorio.ufrn.br:123456789/29809 |
network_acronym_str |
UFRN |
network_name_str |
Repositório Institucional da UFRN |
repository_id_str |
|
spelling |
Campos, João T. L. S.Neves, W. L. A.Costa, Flávio BezerraFernandes Júnior, D.2020-08-13T00:56:10Z2020-08-13T00:56:10Z2018-12-18CAMPOS, J.T.L.S; NEVES, W.L.A.; COSTA, F.B.; FERNANDES, D.. New methodology for evaluation of non-pilot relay distance protection. Journal of Control, Automation and Electrical Systems, [s.l.], v. 30, n. 1, p. 113-124, 18 dez. 2018. Disponível em: https://link.springer.com/article/10.1007/s40313-018-00432-z. Acesso em: 10 ago. 2020. http://dx.doi.org/10.1007/s40313-018-00432-z.2195-3880https://repositorio.ufrn.br/jspui/handle/123456789/2980910.1007/s40313-018-00432-zSpringerAttribution 3.0 Brazilhttp://creativecommons.org/licenses/by/3.0/br/info:eu-repo/semantics/openAccessDistance protectionRelay algorithmsPhasor estimationNew methodology for evaluation of non-pilot relay distance protectioninfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleDistance relays are typically used in transmission line protection. Their accuracy depends on the correct relay parameterization, phasor estimators, and correct usage of distance characteristics. Identifying suitable relay parameterization and algorithms considering multiple transmission line with various topologies and different fault types is a hard task. Here, a methodology based on the relay trip performance is proposed to evaluate all the main concerns of distance protection such as: maloperation trips per relay units in each fault type, overreach operation, and maloperation due to faults closer to the relay. The methodology could identify the best phasor estimators and distance configurations among those evaluated, as well as it could verify the power system topologies which yield in challenges for distance protection. The results achieved by the proposed methodology demonstrated that it can be useful for assisting the development of phasor estimators and new distance characteristics, as well as for setting existing distance protection in specific power system topologiesengreponame:Repositório Institucional da UFRNinstname:Universidade Federal do Rio Grande do Norte (UFRN)instacron:UFRNORIGINALNewMethodologyEvaluation_COSTA_2018.pdfNewMethodologyEvaluation_COSTA_2018.pdfArtigoapplication/pdf538940https://repositorio.ufrn.br/bitstream/123456789/29809/1/NewMethodologyEvaluation_COSTA_2018.pdf5196e7a4c47f827d39b0e46e527d7f17MD51CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8914https://repositorio.ufrn.br/bitstream/123456789/29809/2/license_rdf4d2950bda3d176f570a9f8b328dfbbefMD52LICENSElicense.txtlicense.txttext/plain; charset=utf-81484https://repositorio.ufrn.br/bitstream/123456789/29809/3/license.txte9597aa2854d128fd968be5edc8a28d9MD53TEXTNewMethodologyEvaluation_COSTA_2018.pdf.txtNewMethodologyEvaluation_COSTA_2018.pdf.txtExtracted texttext/plain50577https://repositorio.ufrn.br/bitstream/123456789/29809/4/NewMethodologyEvaluation_COSTA_2018.pdf.txtc148153539ee9ef4d9a4001c8b8e1263MD54THUMBNAILNewMethodologyEvaluation_COSTA_2018.pdf.jpgNewMethodologyEvaluation_COSTA_2018.pdf.jpgGenerated Thumbnailimage/jpeg1720https://repositorio.ufrn.br/bitstream/123456789/29809/5/NewMethodologyEvaluation_COSTA_2018.pdf.jpg09245b4d4726c4e04e1eb68b7d69b2f9MD55123456789/298092020-08-16 04:12:11.414oai:https://repositorio.ufrn.br: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Repositório de PublicaçõesPUBhttp://repositorio.ufrn.br/oai/opendoar:2020-08-16T07:12:11Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)false |
dc.title.pt_BR.fl_str_mv |
New methodology for evaluation of non-pilot relay distance protection |
title |
New methodology for evaluation of non-pilot relay distance protection |
spellingShingle |
New methodology for evaluation of non-pilot relay distance protection Campos, João T. L. S. Distance protection Relay algorithms Phasor estimation |
title_short |
New methodology for evaluation of non-pilot relay distance protection |
title_full |
New methodology for evaluation of non-pilot relay distance protection |
title_fullStr |
New methodology for evaluation of non-pilot relay distance protection |
title_full_unstemmed |
New methodology for evaluation of non-pilot relay distance protection |
title_sort |
New methodology for evaluation of non-pilot relay distance protection |
author |
Campos, João T. L. S. |
author_facet |
Campos, João T. L. S. Neves, W. L. A. Costa, Flávio Bezerra Fernandes Júnior, D. |
author_role |
author |
author2 |
Neves, W. L. A. Costa, Flávio Bezerra Fernandes Júnior, D. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Campos, João T. L. S. Neves, W. L. A. Costa, Flávio Bezerra Fernandes Júnior, D. |
dc.subject.por.fl_str_mv |
Distance protection Relay algorithms Phasor estimation |
topic |
Distance protection Relay algorithms Phasor estimation |
description |
Distance relays are typically used in transmission line protection. Their accuracy depends on the correct relay parameterization, phasor estimators, and correct usage of distance characteristics. Identifying suitable relay parameterization and algorithms considering multiple transmission line with various topologies and different fault types is a hard task. Here, a methodology based on the relay trip performance is proposed to evaluate all the main concerns of distance protection such as: maloperation trips per relay units in each fault type, overreach operation, and maloperation due to faults closer to the relay. The methodology could identify the best phasor estimators and distance configurations among those evaluated, as well as it could verify the power system topologies which yield in challenges for distance protection. The results achieved by the proposed methodology demonstrated that it can be useful for assisting the development of phasor estimators and new distance characteristics, as well as for setting existing distance protection in specific power system topologies |
publishDate |
2018 |
dc.date.issued.fl_str_mv |
2018-12-18 |
dc.date.accessioned.fl_str_mv |
2020-08-13T00:56:10Z |
dc.date.available.fl_str_mv |
2020-08-13T00:56:10Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
CAMPOS, J.T.L.S; NEVES, W.L.A.; COSTA, F.B.; FERNANDES, D.. New methodology for evaluation of non-pilot relay distance protection. Journal of Control, Automation and Electrical Systems, [s.l.], v. 30, n. 1, p. 113-124, 18 dez. 2018. Disponível em: https://link.springer.com/article/10.1007/s40313-018-00432-z. Acesso em: 10 ago. 2020. http://dx.doi.org/10.1007/s40313-018-00432-z. |
dc.identifier.uri.fl_str_mv |
https://repositorio.ufrn.br/jspui/handle/123456789/29809 |
dc.identifier.issn.none.fl_str_mv |
2195-3880 |
dc.identifier.doi.none.fl_str_mv |
10.1007/s40313-018-00432-z |
identifier_str_mv |
CAMPOS, J.T.L.S; NEVES, W.L.A.; COSTA, F.B.; FERNANDES, D.. New methodology for evaluation of non-pilot relay distance protection. Journal of Control, Automation and Electrical Systems, [s.l.], v. 30, n. 1, p. 113-124, 18 dez. 2018. Disponível em: https://link.springer.com/article/10.1007/s40313-018-00432-z. Acesso em: 10 ago. 2020. http://dx.doi.org/10.1007/s40313-018-00432-z. 2195-3880 10.1007/s40313-018-00432-z |
url |
https://repositorio.ufrn.br/jspui/handle/123456789/29809 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.rights.driver.fl_str_mv |
Attribution 3.0 Brazil http://creativecommons.org/licenses/by/3.0/br/ info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Attribution 3.0 Brazil http://creativecommons.org/licenses/by/3.0/br/ |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Springer |
publisher.none.fl_str_mv |
Springer |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFRN instname:Universidade Federal do Rio Grande do Norte (UFRN) instacron:UFRN |
instname_str |
Universidade Federal do Rio Grande do Norte (UFRN) |
instacron_str |
UFRN |
institution |
UFRN |
reponame_str |
Repositório Institucional da UFRN |
collection |
Repositório Institucional da UFRN |
bitstream.url.fl_str_mv |
https://repositorio.ufrn.br/bitstream/123456789/29809/1/NewMethodologyEvaluation_COSTA_2018.pdf https://repositorio.ufrn.br/bitstream/123456789/29809/2/license_rdf https://repositorio.ufrn.br/bitstream/123456789/29809/3/license.txt https://repositorio.ufrn.br/bitstream/123456789/29809/4/NewMethodologyEvaluation_COSTA_2018.pdf.txt https://repositorio.ufrn.br/bitstream/123456789/29809/5/NewMethodologyEvaluation_COSTA_2018.pdf.jpg |
bitstream.checksum.fl_str_mv |
5196e7a4c47f827d39b0e46e527d7f17 4d2950bda3d176f570a9f8b328dfbbef e9597aa2854d128fd968be5edc8a28d9 c148153539ee9ef4d9a4001c8b8e1263 09245b4d4726c4e04e1eb68b7d69b2f9 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN) |
repository.mail.fl_str_mv |
|
_version_ |
1814832671917867008 |