Avaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadas

Detalhes bibliográficos
Autor(a) principal: Oliveira, José Luiz Góes de
Data de Publicação: 2013
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFS
Texto Completo: https://ri.ufs.br/handle/riufs/3570
Resumo: Passivity fit of an implant fixed partial denture (FPD) is one of major factor in treatment success. Among various factors that influence the passive fit of a prostheses is the kind of retained. Thus, the aim of this study was to evaluate, with the aid of linear strain gages (gauges), the tension generated around two implants after installation of a three-unit implant FPD. Five groups were analyzed (n = 5): 1. Control (only the abutments on implants); 2. Cement-retained prosthesis; 3. Screw-retained prosthesis made from plastic cylinders; 4. Screw-retained prosthesis made from Co-Cr machined collar abutments; 5. Hybrid prosthesis (cemented / screwed). For the investigation, homogeneous polyurethane experimental model with two parallel external hexagon implants was used. From this model, transfer impression and one master stone cast was made on which all frameworks were made accompanying a wax pattern. Aiming to measure the tensions, four strain gauges for each implant placed in the mesial, distal, buccal and lingual were glued on the top surface of the experimental block. The tests were performed by installing the samples on the implants according to the characteristics of each group. Five repetitions of readings for each specimen were performed. One-way ANOVA and Tukey test were applied to the average values (p <.05). The mean and standard deviation were obtained: Group 1 (48.71 με ± 0.29), Group 2 (60.03 με ± 22.65) and group 3 (254.15 με ± 46.23), Group 4 (215,42 με ± 30.48), Group 5 (70.05 με ± 13.78). These results showed that the cement-retained prostheses have the ability to produce less stress on the peri-implant area when compared to the screw-retained prosthesis (p≤.05). It was observed that the hybrid group had similar performance to the cement-retained prostheses and the control group (p>.05). Furthermore, the screw-retained prosthesis made from plastic cylinders showed similar performance to the Co-Cr machined collar abutments (p>.05). Finally, these results demonstrated that the generated tension to the peri-implant tissues is directly related to the type of retention.
id UFS-2_06530b9ef30e3265ac7a196c4a25e813
oai_identifier_str oai:ufs.br:riufs/3570
network_acronym_str UFS-2
network_name_str Repositório Institucional da UFS
repository_id_str
spelling Oliveira, José Luiz Góes dehttp://lattes.cnpq.br/3663856976613751Bonjardim, Leonardo Rigoldihttp://lattes.cnpq.br/21754326016352252017-09-26T12:07:08Z2017-09-26T12:07:08Z2013-07-18OLIVEIRA, José Luiz Góes de. Avaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadas. 2013. 64 f. Tese (Doutorado em Ciências da Saúde) - Universidade Federal de Sergipe, Aracaju, 2013.https://ri.ufs.br/handle/riufs/3570Passivity fit of an implant fixed partial denture (FPD) is one of major factor in treatment success. Among various factors that influence the passive fit of a prostheses is the kind of retained. Thus, the aim of this study was to evaluate, with the aid of linear strain gages (gauges), the tension generated around two implants after installation of a three-unit implant FPD. Five groups were analyzed (n = 5): 1. Control (only the abutments on implants); 2. Cement-retained prosthesis; 3. Screw-retained prosthesis made from plastic cylinders; 4. Screw-retained prosthesis made from Co-Cr machined collar abutments; 5. Hybrid prosthesis (cemented / screwed). For the investigation, homogeneous polyurethane experimental model with two parallel external hexagon implants was used. From this model, transfer impression and one master stone cast was made on which all frameworks were made accompanying a wax pattern. Aiming to measure the tensions, four strain gauges for each implant placed in the mesial, distal, buccal and lingual were glued on the top surface of the experimental block. The tests were performed by installing the samples on the implants according to the characteristics of each group. Five repetitions of readings for each specimen were performed. One-way ANOVA and Tukey test were applied to the average values (p <.05). The mean and standard deviation were obtained: Group 1 (48.71 με ± 0.29), Group 2 (60.03 με ± 22.65) and group 3 (254.15 με ± 46.23), Group 4 (215,42 με ± 30.48), Group 5 (70.05 με ± 13.78). These results showed that the cement-retained prostheses have the ability to produce less stress on the peri-implant area when compared to the screw-retained prosthesis (p≤.05). It was observed that the hybrid group had similar performance to the cement-retained prostheses and the control group (p>.05). Furthermore, the screw-retained prosthesis made from plastic cylinders showed similar performance to the Co-Cr machined collar abutments (p>.05). Finally, these results demonstrated that the generated tension to the peri-implant tissues is directly related to the type of retention.A passividade de assentamento de uma prótese parcial fixa sobre implantes é um fator primordial para o sucesso no tratamento. Dentre vários fatores que interferem na adaptação passiva de uma prótese está o tipo de retenção utilizado. Desta forma, o objetivo deste estudo foi avaliar, com o auxílio de extensômetros elétricos lineares (strain gauges), a tensão gerada ao redor de dois implantes após assentamento de uma prótese parcial fixa implantossuportada de 3 elementos. Cinco grupos foram analisados (n=5): 1. Controle (apenas os munhões sobre os implantes); 2. Prótese Cimentada; 3. Prótese Parafusada confeccionada com cilindros plásticos; 4. Prótese Parafusada confeccionada com cilindros com base de Co-Cr; 5. Prótese híbrida (cimentada/parafusada). Para a investigação, foi utilizado um modelo experimental homogêneo a base de poliuretano com dois implantes hexágono externo paralelos entre si. Visando medir as tensões, foram colados na superfície superior do bloco experimental quatro strain gauges para cada implante, posicionados nas faces mesial, distal, vestibular e lingual. Os testes foram executados instalando os corpos de prova sobre os implantes de acordo com as características de cada grupo. Realizou-se 5 repetições de leituras para cada corpo de prova. Análise de variância e teste de Tukey foram aplicados sobre os valores médios obtidos, utilizando um nível de significância de 0,05. A média e desvio-padrão obtidos foram: Grupo 1 (48,71 με ± 0,29); Grupo 2 (60,03 με ± 22,65); Grupo 3 (254,15 με ± 46,23), Grupo 4 (215,42 με ± 30,48), Grupo 5 (70,05 με ± 13,78). Esses resultados mostraram que as próteses cimentadas geraram menos tensão à região periimplantar quando comparadas às próteses parafusadas (p=0,0004/p=0,0008). Observou-se que o grupo híbrido teve desempenho semelhante às próteses cimentadas e ao grupo controle (p=0,9540/p=0,3402). Além disso, as próteses parafusadas confeccionadas com cilindros plásticos apresentaram desempenho semelhante às confeccionadas com cilindros com a base de Co-Cr (p=0,1580). Por fim, estes resultados demonstraram que a tensão gerada aos tecidos perimplantares está diretamente relacionada ao tipo de retenção.Coordenação de Aperfeiçoamento de Pessoal de Nível Superiorapplication/pdfporUniversidade Federal de SergipePós-Graduação em Ciências da SaúdeUFSBRImplante dentárioRetenção em prótese dentáriaPrótese dentáriaDental implantDental prosthesis retentionProsthodonticsCNPQ::CIENCIAS DA SAUDEAvaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadasinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSinstname:Universidade Federal de Sergipe (UFS)instacron:UFSTEXTJOSE_LUIZ_GOES_OLIVEIRA.pdf.txtJOSE_LUIZ_GOES_OLIVEIRA.pdf.txtExtracted texttext/plain119674https://ri.ufs.br/jspui/bitstream/riufs/3570/2/JOSE_LUIZ_GOES_OLIVEIRA.pdf.txt1ecf002f61bf08df5d74c97e9b279a42MD52THUMBNAILJOSE_LUIZ_GOES_OLIVEIRA.pdf.jpgJOSE_LUIZ_GOES_OLIVEIRA.pdf.jpgGenerated Thumbnailimage/jpeg1383https://ri.ufs.br/jspui/bitstream/riufs/3570/3/JOSE_LUIZ_GOES_OLIVEIRA.pdf.jpg743030aa79903bcc71290bb6f1997f3fMD53ORIGINALJOSE_LUIZ_GOES_OLIVEIRA.pdfapplication/pdf1216566https://ri.ufs.br/jspui/bitstream/riufs/3570/1/JOSE_LUIZ_GOES_OLIVEIRA.pdf4ddec552da9469762826a2b18265a0d8MD51riufs/35702017-11-28 16:11:07.122oai:ufs.br:riufs/3570Repositório InstitucionalPUBhttps://ri.ufs.br/oai/requestrepositorio@academico.ufs.bropendoar:2017-11-28T19:11:07Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS)false
dc.title.por.fl_str_mv Avaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadas
title Avaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadas
spellingShingle Avaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadas
Oliveira, José Luiz Góes de
Implante dentário
Retenção em prótese dentária
Prótese dentária
Dental implant
Dental prosthesis retention
Prosthodontics
CNPQ::CIENCIAS DA SAUDE
title_short Avaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadas
title_full Avaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadas
title_fullStr Avaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadas
title_full_unstemmed Avaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadas
title_sort Avaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadas
author Oliveira, José Luiz Góes de
author_facet Oliveira, José Luiz Góes de
author_role author
dc.contributor.author.fl_str_mv Oliveira, José Luiz Góes de
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/3663856976613751
dc.contributor.advisor1.fl_str_mv Bonjardim, Leonardo Rigoldi
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/2175432601635225
contributor_str_mv Bonjardim, Leonardo Rigoldi
dc.subject.por.fl_str_mv Implante dentário
Retenção em prótese dentária
Prótese dentária
topic Implante dentário
Retenção em prótese dentária
Prótese dentária
Dental implant
Dental prosthesis retention
Prosthodontics
CNPQ::CIENCIAS DA SAUDE
dc.subject.eng.fl_str_mv Dental implant
Dental prosthesis retention
Prosthodontics
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS DA SAUDE
description Passivity fit of an implant fixed partial denture (FPD) is one of major factor in treatment success. Among various factors that influence the passive fit of a prostheses is the kind of retained. Thus, the aim of this study was to evaluate, with the aid of linear strain gages (gauges), the tension generated around two implants after installation of a three-unit implant FPD. Five groups were analyzed (n = 5): 1. Control (only the abutments on implants); 2. Cement-retained prosthesis; 3. Screw-retained prosthesis made from plastic cylinders; 4. Screw-retained prosthesis made from Co-Cr machined collar abutments; 5. Hybrid prosthesis (cemented / screwed). For the investigation, homogeneous polyurethane experimental model with two parallel external hexagon implants was used. From this model, transfer impression and one master stone cast was made on which all frameworks were made accompanying a wax pattern. Aiming to measure the tensions, four strain gauges for each implant placed in the mesial, distal, buccal and lingual were glued on the top surface of the experimental block. The tests were performed by installing the samples on the implants according to the characteristics of each group. Five repetitions of readings for each specimen were performed. One-way ANOVA and Tukey test were applied to the average values (p <.05). The mean and standard deviation were obtained: Group 1 (48.71 με ± 0.29), Group 2 (60.03 με ± 22.65) and group 3 (254.15 με ± 46.23), Group 4 (215,42 με ± 30.48), Group 5 (70.05 με ± 13.78). These results showed that the cement-retained prostheses have the ability to produce less stress on the peri-implant area when compared to the screw-retained prosthesis (p≤.05). It was observed that the hybrid group had similar performance to the cement-retained prostheses and the control group (p>.05). Furthermore, the screw-retained prosthesis made from plastic cylinders showed similar performance to the Co-Cr machined collar abutments (p>.05). Finally, these results demonstrated that the generated tension to the peri-implant tissues is directly related to the type of retention.
publishDate 2013
dc.date.issued.fl_str_mv 2013-07-18
dc.date.accessioned.fl_str_mv 2017-09-26T12:07:08Z
dc.date.available.fl_str_mv 2017-09-26T12:07:08Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv OLIVEIRA, José Luiz Góes de. Avaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadas. 2013. 64 f. Tese (Doutorado em Ciências da Saúde) - Universidade Federal de Sergipe, Aracaju, 2013.
dc.identifier.uri.fl_str_mv https://ri.ufs.br/handle/riufs/3570
identifier_str_mv OLIVEIRA, José Luiz Góes de. Avaliação da tensão formada na região periimplantar após a instalação de próteses parciais fixas parafusadas e cimentadas. 2013. 64 f. Tese (Doutorado em Ciências da Saúde) - Universidade Federal de Sergipe, Aracaju, 2013.
url https://ri.ufs.br/handle/riufs/3570
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Sergipe
dc.publisher.program.fl_str_mv Pós-Graduação em Ciências da Saúde
dc.publisher.initials.fl_str_mv UFS
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv Universidade Federal de Sergipe
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFS
instname:Universidade Federal de Sergipe (UFS)
instacron:UFS
instname_str Universidade Federal de Sergipe (UFS)
instacron_str UFS
institution UFS
reponame_str Repositório Institucional da UFS
collection Repositório Institucional da UFS
bitstream.url.fl_str_mv https://ri.ufs.br/jspui/bitstream/riufs/3570/2/JOSE_LUIZ_GOES_OLIVEIRA.pdf.txt
https://ri.ufs.br/jspui/bitstream/riufs/3570/3/JOSE_LUIZ_GOES_OLIVEIRA.pdf.jpg
https://ri.ufs.br/jspui/bitstream/riufs/3570/1/JOSE_LUIZ_GOES_OLIVEIRA.pdf
bitstream.checksum.fl_str_mv 1ecf002f61bf08df5d74c97e9b279a42
743030aa79903bcc71290bb6f1997f3f
4ddec552da9469762826a2b18265a0d8
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS)
repository.mail.fl_str_mv repositorio@academico.ufs.br
_version_ 1802110677668593664