Extração em fase sólida magnética : nova abordagem na determinação de hidrocarbonetos policíclicos aromáticos (HPA) em água produzida por cromatografia líquida de alta eficiência

Detalhes bibliográficos
Autor(a) principal: Caetano, Vinícius Crispim Lima de Barros
Data de Publicação: 2017
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFS
Texto Completo: http://ri.ufs.br/jspui/handle/riufs/9139
Resumo: The oil and gas industry produces huge amounts of produced water (PW), a complex effluent. This product is one of the main constituents of polycyclic aromatic hydrocarbons (PAH), which exhibit high toxicity. Therefore, this study aims at developing and validating a method for determining PAH (Benz(a)anthracene, Benzo(b)fluoranthene, Benzo(k)fluoranthene, Benzo(a)pyrene, and Dibenzo (a,h)anthracene) in PW by using magnetic solid phase extraction (MSPE) and high-performance liquid chromatography with fluorescence detector. We synthesized three new adsorbents: FeCt (with ferric chloride and water rich in natural organic matter); FeCc (with ferric chloride, distilled water, and coconut husk), and FeSt (with ferric sulfate and water rich in natural organic matter). The x-ray diffraction and infrared spectroscopy confirmed obtaining the hybrid materials. The best extraction conditions were obtained by using ultrasonic cleaning as a mixing mechanism with time set to 2.5 minutes for adsorption and 2.5 minutes for desorption, using 10 mL of ethyl acetate as an extractor and 20 mg of hybrid FeSt; the values of PAH recovery varied from 84.3 to 92.3 %. The capacity of reusing the material was assessed and the results exhibited a great recovery with up to 4 cycles of adsorption/desorption. The methodology we propose was applied to two PW samples. The recovery values for samples PWW1 (produced water at well 1) enriched with 100μg L-1 were of 81 – 104%, without the presence of B(a)P standard. As for the PAH concentrations in the sample, they varied from 0.63 to 1.66 μg L-1 for PWW1 from 0.54 to 1.62 μg L-1 for PWW2 (produced water at well 2). The validation of the method was performed for the following parameters: linearity, which exhibits a correlation coefficient (r) above 0.9943 within the interval of 0.5 - 25 μg L-1 ; accuracy and precision, with recovery values between 98.2 – 108.9 %, and coefficient of variation 0.64 – 6.72 % for the concentration levels of 3.8 and 15 μg L-1 (n=3), respectively. LODs varied from 0.012 and 0.02 μg L-1 and LOQs, from 0.036 to 0.06 μg L-1.
id UFS-2_7928534108683d779f9dbe9b070c0bbc
oai_identifier_str oai:ufs.br:riufs/9139
network_acronym_str UFS-2
network_name_str Repositório Institucional da UFS
repository_id_str
spelling Caetano, Vinícius Crispim Lima de BarrosRomão, Luciane Pimenta CruzCunha, Graziele da Costa2018-10-03T16:55:11Z2018-10-03T16:55:11Z2017-11-30CAETANO, Vinícius Crispim Lima de Barros. Extração em fase sólida magnética : nova abordagem na determinação de hidrocarbonetos policíclicos aromáticos (HPA) em água produzida por cromatografia líquida de alta eficiência. 2017. 87 f. Dissertação (Mestrado em Química) - Universidade Federal de Sergipe, São Cristóvão, SE, 2017.http://ri.ufs.br/jspui/handle/riufs/9139The oil and gas industry produces huge amounts of produced water (PW), a complex effluent. This product is one of the main constituents of polycyclic aromatic hydrocarbons (PAH), which exhibit high toxicity. Therefore, this study aims at developing and validating a method for determining PAH (Benz(a)anthracene, Benzo(b)fluoranthene, Benzo(k)fluoranthene, Benzo(a)pyrene, and Dibenzo (a,h)anthracene) in PW by using magnetic solid phase extraction (MSPE) and high-performance liquid chromatography with fluorescence detector. We synthesized three new adsorbents: FeCt (with ferric chloride and water rich in natural organic matter); FeCc (with ferric chloride, distilled water, and coconut husk), and FeSt (with ferric sulfate and water rich in natural organic matter). The x-ray diffraction and infrared spectroscopy confirmed obtaining the hybrid materials. The best extraction conditions were obtained by using ultrasonic cleaning as a mixing mechanism with time set to 2.5 minutes for adsorption and 2.5 minutes for desorption, using 10 mL of ethyl acetate as an extractor and 20 mg of hybrid FeSt; the values of PAH recovery varied from 84.3 to 92.3 %. The capacity of reusing the material was assessed and the results exhibited a great recovery with up to 4 cycles of adsorption/desorption. The methodology we propose was applied to two PW samples. The recovery values for samples PWW1 (produced water at well 1) enriched with 100μg L-1 were of 81 – 104%, without the presence of B(a)P standard. As for the PAH concentrations in the sample, they varied from 0.63 to 1.66 μg L-1 for PWW1 from 0.54 to 1.62 μg L-1 for PWW2 (produced water at well 2). The validation of the method was performed for the following parameters: linearity, which exhibits a correlation coefficient (r) above 0.9943 within the interval of 0.5 - 25 μg L-1 ; accuracy and precision, with recovery values between 98.2 – 108.9 %, and coefficient of variation 0.64 – 6.72 % for the concentration levels of 3.8 and 15 μg L-1 (n=3), respectively. LODs varied from 0.012 and 0.02 μg L-1 and LOQs, from 0.036 to 0.06 μg L-1.A indústria de petróleo e gás produz grandes quantidades de água produzida (AP), que é um efluente complexo, sendo que um dos seus principais constituintes são os Hidrocarbonetos Policíclicos Aromáticos (HPA), os quais apresentam elevada toxicidade. Assim, o presente trabalho tem por objetivo desenvolver e validar um método de determinação de HPA (Benzo(a)Antraceno, Benzo(b)Fluoranteno, Benzo(k)Fluoranteno, Benzo(a)Pireno e Dibenzo(ah)Antraceno) em AP utilizando a extração em fase sólida magnética (MSPE) e cromatografia líquida de alta eficiência com detector de fluorescência. Foram sintetizados três novos adsorventes FeCt (com cloreto férrico e água com alto teor de MON), FeCc (com cloreto férrico, água destilada e bagaço de coco) e FeSt (com sulfato férrico e água com alto teor de MON). A difração de raios X e a espectroscopia de infravermelho confirmaram a obtenção dos materiais híbridos. As melhores condições de extração foram obtidas em banho de ultrassom como mecanismo de agitação, com tempo estipulado em 2,5 min para a adsorção e 2,5 min para a dessorção, utilizando 10 mL de acetato de etila como extrator e 20 mg do híbrido FeSt. Os valores de recuperação dos HPA variaram de 84,3 – 92,3 %. A capacidade de reutilização do material foi avaliada e os resultados apresentaram ótima recuperação com até 4 ciclos de adsorção/dessorção. A metodologia proposta foi aplicada em duas amostras de AP e os valores de recuperação para a amostra de APP1 (água produzida poço 1), enriquecida com 100 μg L-1, foram de 81 – 104 %, sem a presença do padrão do B(a)P, e a concentração dos HPA na amostra variou de 0,63 – 1,66 μg L-1 para o APP1, e de 0,54 – 1,62 μg L-1 para o APP2 (água produzida poço 2). A validação do método foi realizada para os parâmetros: linearidade, com o coeficiente de correlação (r) acima de 0,9943 no intervalo de 0,5 - 25 μg L-1; exatidão e precisão, com valores de recuperação entre 98,2 - 108,9 % e coeficiente de variação 0,64 - 6,72 % para os níveis de concentração 3, 8 e 15 μg L-1 (n=3), respectivamente. Os limites de detecção (LD) variaram entre 0,012 a 0,02 μg L-1 e os limites de quantificação (LQ) entre 0,036 a 0,06 μg L-1.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESSão Cristóvão, SEporHidrocarbonetosIndústria petrolíferaAdsorçãoHidrocarbonetos policíclicos aromáticos (HPA)Água produzidaAdsorvente híbrido magnéticoExtração em fase sólida magnéticaPolycyclic aromatic hydrocarbons (PAH)Produced waterHybrid magnetic adsorbentMagnetic solid phase extractionCIENCIAS EXATAS E DA TERRA::QUIMICAExtração em fase sólida magnética : nova abordagem na determinação de hidrocarbonetos policíclicos aromáticos (HPA) em água produzida por cromatografia líquida de alta eficiênciaMagnetic solid phase extraction : new approach to determining polycyclic aromatic hydrocarbons (PAH) in water produced by high performance liquid chromatographyinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisPós-Graduação em QuímicaUniversidade Federal de Sergipereponame:Repositório Institucional da UFSinstname:Universidade Federal de Sergipe (UFS)instacron:UFSinfo:eu-repo/semantics/openAccessTEXTVINICIUS_CRISPIM_L_BARROS_CAETANO.pdf.txtVINICIUS_CRISPIM_L_BARROS_CAETANO.pdf.txtExtracted texttext/plain146270https://ri.ufs.br/jspui/bitstream/riufs/9139/3/VINICIUS_CRISPIM_L_BARROS_CAETANO.pdf.txt53655abc1ad031202b706644e42fe4e6MD53THUMBNAILVINICIUS_CRISPIM_L_BARROS_CAETANO.pdf.jpgVINICIUS_CRISPIM_L_BARROS_CAETANO.pdf.jpgGenerated Thumbnailimage/jpeg1485https://ri.ufs.br/jspui/bitstream/riufs/9139/4/VINICIUS_CRISPIM_L_BARROS_CAETANO.pdf.jpgb457eab03260e5edc0a5ab209948c582MD54LICENSElicense.txtlicense.txttext/plain; charset=utf-81475https://ri.ufs.br/jspui/bitstream/riufs/9139/1/license.txt098cbbf65c2c15e1fb2e49c5d306a44cMD51ORIGINALVINICIUS_CRISPIM_L_BARROS_CAETANO.pdfVINICIUS_CRISPIM_L_BARROS_CAETANO.pdfapplication/pdf1474381https://ri.ufs.br/jspui/bitstream/riufs/9139/2/VINICIUS_CRISPIM_L_BARROS_CAETANO.pdf72ab2ecfcce6561a8047d2e88f986992MD52riufs/91392018-10-03 13:55:12.105oai:ufs.br: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Repositório InstitucionalPUBhttps://ri.ufs.br/oai/requestrepositorio@academico.ufs.bropendoar:2018-10-03T16:55:12Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS)false
dc.title.pt_BR.fl_str_mv Extração em fase sólida magnética : nova abordagem na determinação de hidrocarbonetos policíclicos aromáticos (HPA) em água produzida por cromatografia líquida de alta eficiência
dc.title.alternative.eng.fl_str_mv Magnetic solid phase extraction : new approach to determining polycyclic aromatic hydrocarbons (PAH) in water produced by high performance liquid chromatography
title Extração em fase sólida magnética : nova abordagem na determinação de hidrocarbonetos policíclicos aromáticos (HPA) em água produzida por cromatografia líquida de alta eficiência
spellingShingle Extração em fase sólida magnética : nova abordagem na determinação de hidrocarbonetos policíclicos aromáticos (HPA) em água produzida por cromatografia líquida de alta eficiência
Caetano, Vinícius Crispim Lima de Barros
Hidrocarbonetos
Indústria petrolífera
Adsorção
Hidrocarbonetos policíclicos aromáticos (HPA)
Água produzida
Adsorvente híbrido magnético
Extração em fase sólida magnética
Polycyclic aromatic hydrocarbons (PAH)
Produced water
Hybrid magnetic adsorbent
Magnetic solid phase extraction
CIENCIAS EXATAS E DA TERRA::QUIMICA
title_short Extração em fase sólida magnética : nova abordagem na determinação de hidrocarbonetos policíclicos aromáticos (HPA) em água produzida por cromatografia líquida de alta eficiência
title_full Extração em fase sólida magnética : nova abordagem na determinação de hidrocarbonetos policíclicos aromáticos (HPA) em água produzida por cromatografia líquida de alta eficiência
title_fullStr Extração em fase sólida magnética : nova abordagem na determinação de hidrocarbonetos policíclicos aromáticos (HPA) em água produzida por cromatografia líquida de alta eficiência
title_full_unstemmed Extração em fase sólida magnética : nova abordagem na determinação de hidrocarbonetos policíclicos aromáticos (HPA) em água produzida por cromatografia líquida de alta eficiência
title_sort Extração em fase sólida magnética : nova abordagem na determinação de hidrocarbonetos policíclicos aromáticos (HPA) em água produzida por cromatografia líquida de alta eficiência
author Caetano, Vinícius Crispim Lima de Barros
author_facet Caetano, Vinícius Crispim Lima de Barros
author_role author
dc.contributor.author.fl_str_mv Caetano, Vinícius Crispim Lima de Barros
dc.contributor.advisor1.fl_str_mv Romão, Luciane Pimenta Cruz
dc.contributor.advisor-co1.fl_str_mv Cunha, Graziele da Costa
contributor_str_mv Romão, Luciane Pimenta Cruz
Cunha, Graziele da Costa
dc.subject.por.fl_str_mv Hidrocarbonetos
Indústria petrolífera
Adsorção
Hidrocarbonetos policíclicos aromáticos (HPA)
Água produzida
Adsorvente híbrido magnético
Extração em fase sólida magnética
topic Hidrocarbonetos
Indústria petrolífera
Adsorção
Hidrocarbonetos policíclicos aromáticos (HPA)
Água produzida
Adsorvente híbrido magnético
Extração em fase sólida magnética
Polycyclic aromatic hydrocarbons (PAH)
Produced water
Hybrid magnetic adsorbent
Magnetic solid phase extraction
CIENCIAS EXATAS E DA TERRA::QUIMICA
dc.subject.eng.fl_str_mv Polycyclic aromatic hydrocarbons (PAH)
Produced water
Hybrid magnetic adsorbent
Magnetic solid phase extraction
dc.subject.cnpq.fl_str_mv CIENCIAS EXATAS E DA TERRA::QUIMICA
description The oil and gas industry produces huge amounts of produced water (PW), a complex effluent. This product is one of the main constituents of polycyclic aromatic hydrocarbons (PAH), which exhibit high toxicity. Therefore, this study aims at developing and validating a method for determining PAH (Benz(a)anthracene, Benzo(b)fluoranthene, Benzo(k)fluoranthene, Benzo(a)pyrene, and Dibenzo (a,h)anthracene) in PW by using magnetic solid phase extraction (MSPE) and high-performance liquid chromatography with fluorescence detector. We synthesized three new adsorbents: FeCt (with ferric chloride and water rich in natural organic matter); FeCc (with ferric chloride, distilled water, and coconut husk), and FeSt (with ferric sulfate and water rich in natural organic matter). The x-ray diffraction and infrared spectroscopy confirmed obtaining the hybrid materials. The best extraction conditions were obtained by using ultrasonic cleaning as a mixing mechanism with time set to 2.5 minutes for adsorption and 2.5 minutes for desorption, using 10 mL of ethyl acetate as an extractor and 20 mg of hybrid FeSt; the values of PAH recovery varied from 84.3 to 92.3 %. The capacity of reusing the material was assessed and the results exhibited a great recovery with up to 4 cycles of adsorption/desorption. The methodology we propose was applied to two PW samples. The recovery values for samples PWW1 (produced water at well 1) enriched with 100μg L-1 were of 81 – 104%, without the presence of B(a)P standard. As for the PAH concentrations in the sample, they varied from 0.63 to 1.66 μg L-1 for PWW1 from 0.54 to 1.62 μg L-1 for PWW2 (produced water at well 2). The validation of the method was performed for the following parameters: linearity, which exhibits a correlation coefficient (r) above 0.9943 within the interval of 0.5 - 25 μg L-1 ; accuracy and precision, with recovery values between 98.2 – 108.9 %, and coefficient of variation 0.64 – 6.72 % for the concentration levels of 3.8 and 15 μg L-1 (n=3), respectively. LODs varied from 0.012 and 0.02 μg L-1 and LOQs, from 0.036 to 0.06 μg L-1.
publishDate 2017
dc.date.issued.fl_str_mv 2017-11-30
dc.date.accessioned.fl_str_mv 2018-10-03T16:55:11Z
dc.date.available.fl_str_mv 2018-10-03T16:55:11Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv CAETANO, Vinícius Crispim Lima de Barros. Extração em fase sólida magnética : nova abordagem na determinação de hidrocarbonetos policíclicos aromáticos (HPA) em água produzida por cromatografia líquida de alta eficiência. 2017. 87 f. Dissertação (Mestrado em Química) - Universidade Federal de Sergipe, São Cristóvão, SE, 2017.
dc.identifier.uri.fl_str_mv http://ri.ufs.br/jspui/handle/riufs/9139
identifier_str_mv CAETANO, Vinícius Crispim Lima de Barros. Extração em fase sólida magnética : nova abordagem na determinação de hidrocarbonetos policíclicos aromáticos (HPA) em água produzida por cromatografia líquida de alta eficiência. 2017. 87 f. Dissertação (Mestrado em Química) - Universidade Federal de Sergipe, São Cristóvão, SE, 2017.
url http://ri.ufs.br/jspui/handle/riufs/9139
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.program.fl_str_mv Pós-Graduação em Química
dc.publisher.initials.fl_str_mv Universidade Federal de Sergipe
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFS
instname:Universidade Federal de Sergipe (UFS)
instacron:UFS
instname_str Universidade Federal de Sergipe (UFS)
instacron_str UFS
institution UFS
reponame_str Repositório Institucional da UFS
collection Repositório Institucional da UFS
bitstream.url.fl_str_mv https://ri.ufs.br/jspui/bitstream/riufs/9139/3/VINICIUS_CRISPIM_L_BARROS_CAETANO.pdf.txt
https://ri.ufs.br/jspui/bitstream/riufs/9139/4/VINICIUS_CRISPIM_L_BARROS_CAETANO.pdf.jpg
https://ri.ufs.br/jspui/bitstream/riufs/9139/1/license.txt
https://ri.ufs.br/jspui/bitstream/riufs/9139/2/VINICIUS_CRISPIM_L_BARROS_CAETANO.pdf
bitstream.checksum.fl_str_mv 53655abc1ad031202b706644e42fe4e6
b457eab03260e5edc0a5ab209948c582
098cbbf65c2c15e1fb2e49c5d306a44c
72ab2ecfcce6561a8047d2e88f986992
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS)
repository.mail.fl_str_mv repositorio@academico.ufs.br
_version_ 1802110807532634112