Efeito da aplicação do microjateamento de óxido de alumínio e discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte previamente erodido

Detalhes bibliográficos
Autor(a) principal: Leão, Luciana de Vasconcelos
Data de Publicação: 2017
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Institucional da UFS
Texto Completo: https://ri.ufs.br/handle/riufs/5907
Resumo: Dental erosion is a result of the demineralization of enamel surface by the action of acids that soften it, and it may affect bracket adhesion to enamel. This research aimed to assess the effect of the application of aluminum oxide sandblasting and aluminum oxide discs on bond strength of metal brackets rebonded on artificially eroded enamel. Fifty-four crowns of bovine incisors were divided into group functions: Control (artificial saliva), Ox Al (aluminum oxide sandblasting), and SL (aluminum oxide discs Sof-Lex Pop On, 3M ESPE). The crowns were fixed in PVC tubes and enamel surface was flattened with carborundum discs (#320, 600, and 1200 Al2O3 discs; Buehler, Lake Bluff, IL, USA) in metallographic polisher (APL4, Arotec). Knoop microhardness was assessed for the standardization of enamel surfaces (HMV-2000; Shimadzu Corporation, Tokyo, Japan). Next, Ox Al and SL teeth were subjected to the erosive action, submerged in Coca-Cola™ for 1 minute, 3x a day for 7 days. Kirium metal brackets, specific for upper right central incisors, slot 022, Roth prescription (3M/Abzil, São José do Rio Preto, São Paulo, Brazil) were bonded on the buccal aspect of teeth. Shear strength was measured with a universal testing machine EMIC (DL200, EMIC, São José dos Pinhais, Paraná, Brazil) at speed of 0.5 mm/min. The Adhesive Remnant Index (ARI) was performed in samples after shear through a magnifying glass (10x). Kolmogorov-Smirnov, Levene, and homoscedasticity tests were used, as well as ANOVA, for the assessment of microhardness and shear strength. The three groups presented no significant differences for microhardness and shear, but the control group had the highest microhardness mean. There were no statistically significant differences among the three groups for shear bond strength (p=0.163). However, the Ox Al group showed higher values for bond strength. The assessment of ARI of groups showed statistically significant difference when comparing the Control group with Ox Al and SL groups. The ARI values showed the prevalence of ARI 3 (50%) for the control group, followed by ARI 4 (22%) and 5 (22%). For Ox Al and SL, ARI 1 and 2 prevailed. The use of aluminum oxide sandblasting and aluminum oxide discs did not increase bond strength of brackets when they were bonded on artificially eroded enamel. The Adhesive Remnant Index indicated that eroded teeth present higher resin adhesion to enamel.
id UFS-2_a9d4bfe046fb44cd6e2af0ab2642a4b8
oai_identifier_str oai:ufs.br:riufs/5907
network_acronym_str UFS-2
network_name_str Repositório Institucional da UFS
repository_id_str
spelling Leão, Luciana de VasconcelosNahsan, Flavia Pardo SalataParanhos, Luiz Renatohttp://lattes.cnpq.br/87958414607022982017-09-27T13:50:44Z2017-09-27T13:50:44Z2017-02-08LEÃO, Luciana de Vasconcelos. Efeito da aplicação do microjateamento de óxido de alumínio e discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte previamente erodido. 2017. 48 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Sergipe, Aracaju, 2017.https://ri.ufs.br/handle/riufs/5907Dental erosion is a result of the demineralization of enamel surface by the action of acids that soften it, and it may affect bracket adhesion to enamel. This research aimed to assess the effect of the application of aluminum oxide sandblasting and aluminum oxide discs on bond strength of metal brackets rebonded on artificially eroded enamel. Fifty-four crowns of bovine incisors were divided into group functions: Control (artificial saliva), Ox Al (aluminum oxide sandblasting), and SL (aluminum oxide discs Sof-Lex Pop On, 3M ESPE). The crowns were fixed in PVC tubes and enamel surface was flattened with carborundum discs (#320, 600, and 1200 Al2O3 discs; Buehler, Lake Bluff, IL, USA) in metallographic polisher (APL4, Arotec). Knoop microhardness was assessed for the standardization of enamel surfaces (HMV-2000; Shimadzu Corporation, Tokyo, Japan). Next, Ox Al and SL teeth were subjected to the erosive action, submerged in Coca-Cola™ for 1 minute, 3x a day for 7 days. Kirium metal brackets, specific for upper right central incisors, slot 022, Roth prescription (3M/Abzil, São José do Rio Preto, São Paulo, Brazil) were bonded on the buccal aspect of teeth. Shear strength was measured with a universal testing machine EMIC (DL200, EMIC, São José dos Pinhais, Paraná, Brazil) at speed of 0.5 mm/min. The Adhesive Remnant Index (ARI) was performed in samples after shear through a magnifying glass (10x). Kolmogorov-Smirnov, Levene, and homoscedasticity tests were used, as well as ANOVA, for the assessment of microhardness and shear strength. The three groups presented no significant differences for microhardness and shear, but the control group had the highest microhardness mean. There were no statistically significant differences among the three groups for shear bond strength (p=0.163). However, the Ox Al group showed higher values for bond strength. The assessment of ARI of groups showed statistically significant difference when comparing the Control group with Ox Al and SL groups. The ARI values showed the prevalence of ARI 3 (50%) for the control group, followed by ARI 4 (22%) and 5 (22%). For Ox Al and SL, ARI 1 and 2 prevailed. The use of aluminum oxide sandblasting and aluminum oxide discs did not increase bond strength of brackets when they were bonded on artificially eroded enamel. The Adhesive Remnant Index indicated that eroded teeth present higher resin adhesion to enamel.O objetivo desta pesquisa foi avaliar o efeito da aplicação do microjateamento de óxido de alumínio e de discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte erodido artificialmente. Cinquenta e quatro coroas de incisivos bovinos foram divididas em função dos grupos: Controle (Saliva Artificial), Ox Al (Microjateamento com óxido de alumínio) e SL (discos de óxido de alumínio (Sof-Lex Pop On, 3M ESPE). As coroas foram fixadas em tubos de PVC e a superfície do esmalte foi planificada com discos de carborundum (numerações 320, 600 e 1200 discos de Al2O3; Buehler, Lake Bluff, IL, USA), em Politriz Metalográfica (APL4, Arotec). A microdureza Knoop foi aferida para padronização das superfícies de esmalte (HMV-2000; Shimadzu Corporation, Tokyo, Japan). Após aferição os dentes de OxAl e SL foram submetidos ao desafio erosivo, submersos em Coca-Cola® por 1 minuto, 3X ao dia, por 7 dias. Foram colados braquetes metálicos Kirium específicos para incisivos centrais superiores direitos, slot 022”, prescrição Roth [(3M/Abzil, São José do Rio Preto, São Paulo, Brasil)] na face vestibular do dente. A força de cisalhamento foi mensurada por meio de uma máquina de teste universal EMIC (DL200, EMIC, São José dos Pinhais, Paraná) com velocidade 0,5mm/min. O Índice de Remanescente Adesivo (IRA) foi obtido nas amostras utilizando-se lupa (10X). Foram aplicados os testes de Kolmogorv-Smirnov, de Levene e a homocedasticidade e ANOVA para avaliação da microdureza e força de cisalhamento. Não houve diferenças estatisticamente significantes entre os três grupos quando avaliadas microdureza (p=0,163). Porém, ao avaliar o IRA entre grupos, houve diferença estatisticamente significativa ao comparar o grupo Controle com o OxAl e SL. Sendo a prevalência de IRA 3 (50%) para o grupo controle, seguido de IRA 4 (22%) e 5 (22%), respectivamente. Para OxAl e SL, IRA 1 e 2 prevaleceram. Concluiu-se que o uso de microjateamento de óxido de alumínio e discos de óxido de alumínio não aumentaram positivamente a resistência adesiva dos braquetes quando colados em esmalte erodido artificialmente. O índice de remanescente adesivo indicou que dentes erodidos apresentam uma maior adesão da resina ao esmalte.application/pdfporUniversidade Federal de SergipePós-Graduação em OdontologiaUFSBrasilOdontologiaResistência ao cisalhamentoBraqueteOrtodontiaErosão dentáriaShear bond strengthOrthodonticsEnamel erosionCIENCIAS DA SAUDE::ODONTOLOGIAEfeito da aplicação do microjateamento de óxido de alumínio e discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte previamente erodidoThe effectiveness of aluminum oxide sandblasting and aluminum oxide discs on shear bond strenght of metal brackets bonded in eroded enamelinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSinstname:Universidade Federal de Sergipe (UFS)instacron:UFSORIGINALLUCIANA_VASCONCELOS_LEAO.pdfapplication/pdf1190277https://ri.ufs.br/jspui/bitstream/riufs/5907/1/LUCIANA_VASCONCELOS_LEAO.pdf0865e723a00569311b8f270856c9f516MD51TEXTLUCIANA_VASCONCELOS_LEAO.pdf.txtLUCIANA_VASCONCELOS_LEAO.pdf.txtExtracted texttext/plain76354https://ri.ufs.br/jspui/bitstream/riufs/5907/2/LUCIANA_VASCONCELOS_LEAO.pdf.txt48ccbbdf583188c2171e6bdde345beacMD52THUMBNAILLUCIANA_VASCONCELOS_LEAO.pdf.jpgLUCIANA_VASCONCELOS_LEAO.pdf.jpgGenerated Thumbnailimage/jpeg1234https://ri.ufs.br/jspui/bitstream/riufs/5907/3/LUCIANA_VASCONCELOS_LEAO.pdf.jpg784700fa93df6ed2972be592c05d84edMD53riufs/59072017-12-21 21:41:04.898oai:ufs.br:riufs/5907Repositório InstitucionalPUBhttps://ri.ufs.br/oai/requestrepositorio@academico.ufs.bropendoar:2017-12-22T00:41:04Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS)false
dc.title.por.fl_str_mv Efeito da aplicação do microjateamento de óxido de alumínio e discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte previamente erodido
dc.title.alternative.eng.fl_str_mv The effectiveness of aluminum oxide sandblasting and aluminum oxide discs on shear bond strenght of metal brackets bonded in eroded enamel
title Efeito da aplicação do microjateamento de óxido de alumínio e discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte previamente erodido
spellingShingle Efeito da aplicação do microjateamento de óxido de alumínio e discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte previamente erodido
Leão, Luciana de Vasconcelos
Odontologia
Resistência ao cisalhamento
Braquete
Ortodontia
Erosão dentária
Shear bond strength
Orthodontics
Enamel erosion
CIENCIAS DA SAUDE::ODONTOLOGIA
title_short Efeito da aplicação do microjateamento de óxido de alumínio e discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte previamente erodido
title_full Efeito da aplicação do microjateamento de óxido de alumínio e discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte previamente erodido
title_fullStr Efeito da aplicação do microjateamento de óxido de alumínio e discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte previamente erodido
title_full_unstemmed Efeito da aplicação do microjateamento de óxido de alumínio e discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte previamente erodido
title_sort Efeito da aplicação do microjateamento de óxido de alumínio e discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte previamente erodido
author Leão, Luciana de Vasconcelos
author_facet Leão, Luciana de Vasconcelos
author_role author
dc.contributor.author.fl_str_mv Leão, Luciana de Vasconcelos
dc.contributor.advisor1.fl_str_mv Nahsan, Flavia Pardo Salata
dc.contributor.advisor-co1.fl_str_mv Paranhos, Luiz Renato
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/8795841460702298
contributor_str_mv Nahsan, Flavia Pardo Salata
Paranhos, Luiz Renato
dc.subject.por.fl_str_mv Odontologia
Resistência ao cisalhamento
Braquete
Ortodontia
Erosão dentária
topic Odontologia
Resistência ao cisalhamento
Braquete
Ortodontia
Erosão dentária
Shear bond strength
Orthodontics
Enamel erosion
CIENCIAS DA SAUDE::ODONTOLOGIA
dc.subject.eng.fl_str_mv Shear bond strength
Orthodontics
Enamel erosion
dc.subject.cnpq.fl_str_mv CIENCIAS DA SAUDE::ODONTOLOGIA
description Dental erosion is a result of the demineralization of enamel surface by the action of acids that soften it, and it may affect bracket adhesion to enamel. This research aimed to assess the effect of the application of aluminum oxide sandblasting and aluminum oxide discs on bond strength of metal brackets rebonded on artificially eroded enamel. Fifty-four crowns of bovine incisors were divided into group functions: Control (artificial saliva), Ox Al (aluminum oxide sandblasting), and SL (aluminum oxide discs Sof-Lex Pop On, 3M ESPE). The crowns were fixed in PVC tubes and enamel surface was flattened with carborundum discs (#320, 600, and 1200 Al2O3 discs; Buehler, Lake Bluff, IL, USA) in metallographic polisher (APL4, Arotec). Knoop microhardness was assessed for the standardization of enamel surfaces (HMV-2000; Shimadzu Corporation, Tokyo, Japan). Next, Ox Al and SL teeth were subjected to the erosive action, submerged in Coca-Cola™ for 1 minute, 3x a day for 7 days. Kirium metal brackets, specific for upper right central incisors, slot 022, Roth prescription (3M/Abzil, São José do Rio Preto, São Paulo, Brazil) were bonded on the buccal aspect of teeth. Shear strength was measured with a universal testing machine EMIC (DL200, EMIC, São José dos Pinhais, Paraná, Brazil) at speed of 0.5 mm/min. The Adhesive Remnant Index (ARI) was performed in samples after shear through a magnifying glass (10x). Kolmogorov-Smirnov, Levene, and homoscedasticity tests were used, as well as ANOVA, for the assessment of microhardness and shear strength. The three groups presented no significant differences for microhardness and shear, but the control group had the highest microhardness mean. There were no statistically significant differences among the three groups for shear bond strength (p=0.163). However, the Ox Al group showed higher values for bond strength. The assessment of ARI of groups showed statistically significant difference when comparing the Control group with Ox Al and SL groups. The ARI values showed the prevalence of ARI 3 (50%) for the control group, followed by ARI 4 (22%) and 5 (22%). For Ox Al and SL, ARI 1 and 2 prevailed. The use of aluminum oxide sandblasting and aluminum oxide discs did not increase bond strength of brackets when they were bonded on artificially eroded enamel. The Adhesive Remnant Index indicated that eroded teeth present higher resin adhesion to enamel.
publishDate 2017
dc.date.accessioned.fl_str_mv 2017-09-27T13:50:44Z
dc.date.available.fl_str_mv 2017-09-27T13:50:44Z
dc.date.issued.fl_str_mv 2017-02-08
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv LEÃO, Luciana de Vasconcelos. Efeito da aplicação do microjateamento de óxido de alumínio e discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte previamente erodido. 2017. 48 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Sergipe, Aracaju, 2017.
dc.identifier.uri.fl_str_mv https://ri.ufs.br/handle/riufs/5907
identifier_str_mv LEÃO, Luciana de Vasconcelos. Efeito da aplicação do microjateamento de óxido de alumínio e discos de óxido de alumínio na resistência adesiva de braquetes metálicos recolados em esmalte previamente erodido. 2017. 48 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Sergipe, Aracaju, 2017.
url https://ri.ufs.br/handle/riufs/5907
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Sergipe
dc.publisher.program.fl_str_mv Pós-Graduação em Odontologia
dc.publisher.initials.fl_str_mv UFS
dc.publisher.country.fl_str_mv Brasil
publisher.none.fl_str_mv Universidade Federal de Sergipe
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFS
instname:Universidade Federal de Sergipe (UFS)
instacron:UFS
instname_str Universidade Federal de Sergipe (UFS)
instacron_str UFS
institution UFS
reponame_str Repositório Institucional da UFS
collection Repositório Institucional da UFS
bitstream.url.fl_str_mv https://ri.ufs.br/jspui/bitstream/riufs/5907/1/LUCIANA_VASCONCELOS_LEAO.pdf
https://ri.ufs.br/jspui/bitstream/riufs/5907/2/LUCIANA_VASCONCELOS_LEAO.pdf.txt
https://ri.ufs.br/jspui/bitstream/riufs/5907/3/LUCIANA_VASCONCELOS_LEAO.pdf.jpg
bitstream.checksum.fl_str_mv 0865e723a00569311b8f270856c9f516
48ccbbdf583188c2171e6bdde345beac
784700fa93df6ed2972be592c05d84ed
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS)
repository.mail.fl_str_mv repositorio@academico.ufs.br
_version_ 1802110781367517184