Análise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morse
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Tipo de documento: | Dissertação |
Idioma: | por |
Título da fonte: | Repositório Institucional da UFS |
Texto Completo: | https://ri.ufs.br/handle/riufs/5894 |
Resumo: | Objective: Examine the fatigue resistance of the joint implant-abutment, in straight and anatomical types, submitted to cyclic loads. Material and methods: We used 37 implants (3.75 x 11mm) with morse taper system and 37 abutments, divided into two groups (n = 16: straight abutment, n=21 anatomical abutment, Neodent® Curitiba, Paraná, Brazil). The sets were submitted to cyclic testing using servo-hydraulic equipment, fixing the number of cycles at 5 million. Three sets implant-abutment of each group were subjected to bending tests to determine the maximum load resistance of the samples, which served as a parameter to measure the cyclic tests. We evaluated number of cycles, load and bending moment of the samples. The Fisher’s Test and simple independent test of Mann Whitney were applied. To characterize the survival timings of the test samples, the log-rank test was used. Results: Out of the 31 abutments cyclically tested, 17 (54.8%) fractured in a number of cycles below 5 million established, and 8 (25.8%) belonged to the group of the straight abutments and 9 (29%) of the anatomical abutments, 14 samples (45.2%) resisted the cyclic (5-straight abutments and 9-anatomical abutments). According to Fisher's Exact Test showed no statistical difference between groups (p = 0.394). In relation to the load (N) submitted during the cyclic test, the straight abutments showed larger fracture loads (mean: 566N±59N) that anatomical abutments (mean: 367N±80N). In addition, the minimum and maximum load values occurring in fractured samples of the straight group were higher compared to the anatomical. Regarding the average values of bending moment (Nmm), the Mann Whitney showed variations of the moment in both groups, and the fractured samples behaved slightly significant (p = 0.09). Conclusion: In cyclic fatigue tests, the solid straight abutments obtained average load and bending moment greater than the anatomical abutments. Considering fatigue strength of the fractured samples, there was a significant difference in the load variable and bending moment, with the straight abutment showing higher mean, moreover, for the varying cycles, the two types of abutments (straight and anatomical) behaved mechanically in a similar way. |
id |
UFS-2_d6b8b34548584d47c816a473310487a1 |
---|---|
oai_identifier_str |
oai:ufs.br:riufs/5894 |
network_acronym_str |
UFS-2 |
network_name_str |
Repositório Institucional da UFS |
repository_id_str |
|
spelling |
Santos, Vanessa Tavares de GoisTrento, Cleverson Lucianohttp://lattes.cnpq.br/13606113368488062017-09-27T13:50:39Z2017-09-27T13:50:39Z2014-02-17Santos, Vanessa Tavares de Gois. Análise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morse. 2014. 62 f. Dissertação (Pós-Graduação em Odontologia) - Universidade Federal de Sergipe, Aracaju, 2014.https://ri.ufs.br/handle/riufs/5894Objective: Examine the fatigue resistance of the joint implant-abutment, in straight and anatomical types, submitted to cyclic loads. Material and methods: We used 37 implants (3.75 x 11mm) with morse taper system and 37 abutments, divided into two groups (n = 16: straight abutment, n=21 anatomical abutment, Neodent® Curitiba, Paraná, Brazil). The sets were submitted to cyclic testing using servo-hydraulic equipment, fixing the number of cycles at 5 million. Three sets implant-abutment of each group were subjected to bending tests to determine the maximum load resistance of the samples, which served as a parameter to measure the cyclic tests. We evaluated number of cycles, load and bending moment of the samples. The Fisher’s Test and simple independent test of Mann Whitney were applied. To characterize the survival timings of the test samples, the log-rank test was used. Results: Out of the 31 abutments cyclically tested, 17 (54.8%) fractured in a number of cycles below 5 million established, and 8 (25.8%) belonged to the group of the straight abutments and 9 (29%) of the anatomical abutments, 14 samples (45.2%) resisted the cyclic (5-straight abutments and 9-anatomical abutments). According to Fisher's Exact Test showed no statistical difference between groups (p = 0.394). In relation to the load (N) submitted during the cyclic test, the straight abutments showed larger fracture loads (mean: 566N±59N) that anatomical abutments (mean: 367N±80N). In addition, the minimum and maximum load values occurring in fractured samples of the straight group were higher compared to the anatomical. Regarding the average values of bending moment (Nmm), the Mann Whitney showed variations of the moment in both groups, and the fractured samples behaved slightly significant (p = 0.09). Conclusion: In cyclic fatigue tests, the solid straight abutments obtained average load and bending moment greater than the anatomical abutments. Considering fatigue strength of the fractured samples, there was a significant difference in the load variable and bending moment, with the straight abutment showing higher mean, moreover, for the varying cycles, the two types of abutments (straight and anatomical) behaved mechanically in a similar way.Objetivo: Analisar a resistência à fadiga dos conjuntos implante/pilar, nos tipos reto e anatômico, submetidos a cargas cíclicas. Material e métodos: Foram utilizados 37 implantes (3.75 x 11mm) com sistema cone morse e 37 pilares, divididos em dois grupos (n=16: pilar reto, n=21: pilar anatômico, Neodent® Curitiba, Paraná, Brasil). Os conjuntos foram submetidos a testes de flexão e testes cíclicos, fixando-se o número de ciclos em 5 milhões, em equipamento servo-hidráulico. Três conjuntos implante/pilar de cada grupo foram submetidos a testes de flexão para determinação da carga máxima de resistência das amostras, que serviu como medida parâmetro para os ensaios cíclicos. Foram avaliados número de ciclos, carga e momento fletor das amostras. O Teste de Fisher e teste independente simples de Mann Whitney foram aplicados. Para caracterizar os tempos de sobrevivência das amostras em ensaio, foi utilizado o Teste Log-Rank. Resultados: Dos 31 pilares testados ciclicamente, 17 (54,8%) fraturaram em um número de ciclos abaixo dos 5 milhões estabelecidos, sendo que 8 (25,8%) pertenciam ao grupo dos pilares retos e 9 (29%) dos pilares anatômicos; 14 amostras (45,2%) resistiram aos testes cíclicos (5-pilares retos (16,1%) e 9-pilares anatômicos (29,1%). De acordo com o Teste Exato de Fisher não houve diferença estatística entre os grupos (p=0,394). Em relação à carga (N) submetida durante o ensaio cíclico, os pilares retos apresentaram cargas maiores de fratura (média: 566N±59N) que os pilares anatômicos (média: 367N±80N). Além disso, os valores mínimos e máximos de carga ocorridos nas amostras fraturadas do grupo reto foram maiores em relação aos anatômicos. Quanto aos valores médios de momento fletor (Nmm), o Teste de Mann Whitney constatou variações do momento nos dois grupos, as amostras fraturadas comportaram-se de maneira ligeiramente significante (p=0,09). Conclusão: Nos ensaios cíclicos de fadiga, os pilares retos sólidos obtiveram médias de carga e de momento fletor maiores que os pilares anatômicos. Considerando resistência à fadiga das amostras fraturadas, houve diferença significante nas variáveis carga e momento fletor, com o pilar reto mostrando maiores médias; além disso, quanto à variável ciclo, os dois tipos de pilares (retos e anatômicos) comportaram-se mecanicamente de maneira semelhante.Fundação de Apoio a Pesquisa e à Inovação Tecnológica do Estado de Sergipe - FAPITEC/SEapplication/pdfporUniversidade Federal de SergipePós-Graduação em OdontologiaUFSBrasilImplantes dentáriosMateriais (fadiga)Carga imediata em implantes dentáriosMateriais dentáriosTratamento dentárioOdontologiaResistência de materiaisFenômenos mecânicosCIENCIAS DA SAUDE::ODONTOLOGIAAnálise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morseinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFSinstname:Universidade Federal de Sergipe (UFS)instacron:UFSORIGINALVANESSA_TAVARES_GOIS_SANTOS.pdfapplication/pdf935700https://ri.ufs.br/jspui/bitstream/riufs/5894/1/VANESSA_TAVARES_GOIS_SANTOS.pdf5c90f5edd33f5b024761c68239aa1889MD51TEXTVANESSA_TAVARES_GOIS_SANTOS.pdf.txtVANESSA_TAVARES_GOIS_SANTOS.pdf.txtExtracted texttext/plain90287https://ri.ufs.br/jspui/bitstream/riufs/5894/2/VANESSA_TAVARES_GOIS_SANTOS.pdf.txtf06488df55da0798a2237c0528aafd10MD52THUMBNAILVANESSA_TAVARES_GOIS_SANTOS.pdf.jpgVANESSA_TAVARES_GOIS_SANTOS.pdf.jpgGenerated Thumbnailimage/jpeg1196https://ri.ufs.br/jspui/bitstream/riufs/5894/3/VANESSA_TAVARES_GOIS_SANTOS.pdf.jpgae34a9ff72c85dd9dbfadad336f7947dMD53riufs/58942017-12-21 21:40:09.695oai:ufs.br:riufs/5894Repositório InstitucionalPUBhttps://ri.ufs.br/oai/requestrepositorio@academico.ufs.bropendoar:2017-12-22T00:40:09Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS)false |
dc.title.por.fl_str_mv |
Análise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morse |
title |
Análise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morse |
spellingShingle |
Análise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morse Santos, Vanessa Tavares de Gois Implantes dentários Materiais (fadiga) Carga imediata em implantes dentários Materiais dentários Tratamento dentário Odontologia Resistência de materiais Fenômenos mecânicos CIENCIAS DA SAUDE::ODONTOLOGIA |
title_short |
Análise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morse |
title_full |
Análise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morse |
title_fullStr |
Análise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morse |
title_full_unstemmed |
Análise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morse |
title_sort |
Análise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morse |
author |
Santos, Vanessa Tavares de Gois |
author_facet |
Santos, Vanessa Tavares de Gois |
author_role |
author |
dc.contributor.author.fl_str_mv |
Santos, Vanessa Tavares de Gois |
dc.contributor.advisor1.fl_str_mv |
Trento, Cleverson Luciano |
dc.contributor.authorLattes.fl_str_mv |
http://lattes.cnpq.br/1360611336848806 |
contributor_str_mv |
Trento, Cleverson Luciano |
dc.subject.por.fl_str_mv |
Implantes dentários Materiais (fadiga) Carga imediata em implantes dentários Materiais dentários Tratamento dentário Odontologia Resistência de materiais Fenômenos mecânicos |
topic |
Implantes dentários Materiais (fadiga) Carga imediata em implantes dentários Materiais dentários Tratamento dentário Odontologia Resistência de materiais Fenômenos mecânicos CIENCIAS DA SAUDE::ODONTOLOGIA |
dc.subject.cnpq.fl_str_mv |
CIENCIAS DA SAUDE::ODONTOLOGIA |
description |
Objective: Examine the fatigue resistance of the joint implant-abutment, in straight and anatomical types, submitted to cyclic loads. Material and methods: We used 37 implants (3.75 x 11mm) with morse taper system and 37 abutments, divided into two groups (n = 16: straight abutment, n=21 anatomical abutment, Neodent® Curitiba, Paraná, Brazil). The sets were submitted to cyclic testing using servo-hydraulic equipment, fixing the number of cycles at 5 million. Three sets implant-abutment of each group were subjected to bending tests to determine the maximum load resistance of the samples, which served as a parameter to measure the cyclic tests. We evaluated number of cycles, load and bending moment of the samples. The Fisher’s Test and simple independent test of Mann Whitney were applied. To characterize the survival timings of the test samples, the log-rank test was used. Results: Out of the 31 abutments cyclically tested, 17 (54.8%) fractured in a number of cycles below 5 million established, and 8 (25.8%) belonged to the group of the straight abutments and 9 (29%) of the anatomical abutments, 14 samples (45.2%) resisted the cyclic (5-straight abutments and 9-anatomical abutments). According to Fisher's Exact Test showed no statistical difference between groups (p = 0.394). In relation to the load (N) submitted during the cyclic test, the straight abutments showed larger fracture loads (mean: 566N±59N) that anatomical abutments (mean: 367N±80N). In addition, the minimum and maximum load values occurring in fractured samples of the straight group were higher compared to the anatomical. Regarding the average values of bending moment (Nmm), the Mann Whitney showed variations of the moment in both groups, and the fractured samples behaved slightly significant (p = 0.09). Conclusion: In cyclic fatigue tests, the solid straight abutments obtained average load and bending moment greater than the anatomical abutments. Considering fatigue strength of the fractured samples, there was a significant difference in the load variable and bending moment, with the straight abutment showing higher mean, moreover, for the varying cycles, the two types of abutments (straight and anatomical) behaved mechanically in a similar way. |
publishDate |
2014 |
dc.date.issued.fl_str_mv |
2014-02-17 |
dc.date.accessioned.fl_str_mv |
2017-09-27T13:50:39Z |
dc.date.available.fl_str_mv |
2017-09-27T13:50:39Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
format |
masterThesis |
status_str |
publishedVersion |
dc.identifier.citation.fl_str_mv |
Santos, Vanessa Tavares de Gois. Análise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morse. 2014. 62 f. Dissertação (Pós-Graduação em Odontologia) - Universidade Federal de Sergipe, Aracaju, 2014. |
dc.identifier.uri.fl_str_mv |
https://ri.ufs.br/handle/riufs/5894 |
identifier_str_mv |
Santos, Vanessa Tavares de Gois. Análise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morse. 2014. 62 f. Dissertação (Pós-Graduação em Odontologia) - Universidade Federal de Sergipe, Aracaju, 2014. |
url |
https://ri.ufs.br/handle/riufs/5894 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidade Federal de Sergipe |
dc.publisher.program.fl_str_mv |
Pós-Graduação em Odontologia |
dc.publisher.initials.fl_str_mv |
UFS |
dc.publisher.country.fl_str_mv |
Brasil |
publisher.none.fl_str_mv |
Universidade Federal de Sergipe |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFS instname:Universidade Federal de Sergipe (UFS) instacron:UFS |
instname_str |
Universidade Federal de Sergipe (UFS) |
instacron_str |
UFS |
institution |
UFS |
reponame_str |
Repositório Institucional da UFS |
collection |
Repositório Institucional da UFS |
bitstream.url.fl_str_mv |
https://ri.ufs.br/jspui/bitstream/riufs/5894/1/VANESSA_TAVARES_GOIS_SANTOS.pdf https://ri.ufs.br/jspui/bitstream/riufs/5894/2/VANESSA_TAVARES_GOIS_SANTOS.pdf.txt https://ri.ufs.br/jspui/bitstream/riufs/5894/3/VANESSA_TAVARES_GOIS_SANTOS.pdf.jpg |
bitstream.checksum.fl_str_mv |
5c90f5edd33f5b024761c68239aa1889 f06488df55da0798a2237c0528aafd10 ae34a9ff72c85dd9dbfadad336f7947d |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional da UFS - Universidade Federal de Sergipe (UFS) |
repository.mail.fl_str_mv |
repositorio@academico.ufs.br |
_version_ |
1802110674760892416 |