Assessment methods of vastus lateralis muscle architecture using panoramic ultrasound: a new approach, test-retest reliability and measurement error

Detalhes bibliográficos
Autor(a) principal: Soares, André Luiz Conveniente
Data de Publicação: 2021
Outros Autores: Nogueira, Fernando dos Santos, Gomes, Paulo Sergio Chagas
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
Texto Completo: https://periodicos.ufsc.br/index.php/rbcdh/article/view/76402
Resumo: Extended-field-of-view ultrasonography is a valid alternative to determine the dimensions of the skeletal striated muscle; however, some factors may influence the final measurement. The aim of this study was to determine the test-retest reliability and measurement error of  vastus lateralis muscle architecture variables through internal anatomical landmarks and to compare three fixed determined points using extended-field-of-view ultrasonography. Twelve young (24 ± 6 years) adult university male students participated in the study. Images were obtained through extended-field-of-view ultrasonography of the vastus lateralis muscle. Measurements were made for muscle thickness (MT), fascicle length (FL), and fascicle pennation angle (FA) using a method that identifies internal anatomical landmarks. MT was also measured at predetermined distances of 2 cm proximal, 6 cm proximal, and 2 cm distal. One-way ANOVA with repeated measures did not identify any test-retest significant differences for all variables measured. Typical measurement error in centimeters (cm) or degrees (º), coefficient of variation in percentage (%) and intraclass correlation coefficient were MT = 0.07 cm, 2.93%, 0.964; FL = 0.31 cm, 2.89%, 0.947; FA = 0.92°, 4.08%, 0.942; MT 2 cm proximal = 0.10 cm, 3.77%, 0.910; MT 6 cm proximal = 0.27 cm, 9.66%, 0.576; MT 2 cm distal = 0.35 cm, 19.76%, 0.564. MT, FL and FA showed high reliability and low measurement error. Internal anatomical landmarks proved to be more reliable and presented smaller measurement errors when compared to the predetermined distances method.
id UFSC-16_778decea19d60cd3a8d365327b5fa861
oai_identifier_str oai:periodicos.ufsc.br:article/76402
network_acronym_str UFSC-16
network_name_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository_id_str
spelling Assessment methods of vastus lateralis muscle architecture using panoramic ultrasound: a new approach, test-retest reliability and measurement errorMétodos de avaliação da arquitetura do músculo vasto lateral usando ultrassonografia panorâmica: nova abordagem, confiabilidade teste-reteste e erro da medidaExtended-field-of-view ultrasonography is a valid alternative to determine the dimensions of the skeletal striated muscle; however, some factors may influence the final measurement. The aim of this study was to determine the test-retest reliability and measurement error of  vastus lateralis muscle architecture variables through internal anatomical landmarks and to compare three fixed determined points using extended-field-of-view ultrasonography. Twelve young (24 ± 6 years) adult university male students participated in the study. Images were obtained through extended-field-of-view ultrasonography of the vastus lateralis muscle. Measurements were made for muscle thickness (MT), fascicle length (FL), and fascicle pennation angle (FA) using a method that identifies internal anatomical landmarks. MT was also measured at predetermined distances of 2 cm proximal, 6 cm proximal, and 2 cm distal. One-way ANOVA with repeated measures did not identify any test-retest significant differences for all variables measured. Typical measurement error in centimeters (cm) or degrees (º), coefficient of variation in percentage (%) and intraclass correlation coefficient were MT = 0.07 cm, 2.93%, 0.964; FL = 0.31 cm, 2.89%, 0.947; FA = 0.92°, 4.08%, 0.942; MT 2 cm proximal = 0.10 cm, 3.77%, 0.910; MT 6 cm proximal = 0.27 cm, 9.66%, 0.576; MT 2 cm distal = 0.35 cm, 19.76%, 0.564. MT, FL and FA showed high reliability and low measurement error. Internal anatomical landmarks proved to be more reliable and presented smaller measurement errors when compared to the predetermined distances method.A ultrassonografia panorâmica é uma alternativa válida para determinar as dimensões da musculatura estriada esquelética, entretanto alguns fatores podem influenciar a medida final. Objetivou-se determinar a confiabilidade e o erro da medida das variáveis da arquitetura do músculo vasto lateral através de marcações anatômicas internas, bem como comparar dois métodos de avaliação diferentes através da ultrassonografia panorâmica. Doze homens (idade: 24 ± 6 anos) participaram do estudo. As imagens foram obtidas através da ultrassonografia panorâmica do músculo vasto lateral. Foram realizadas as medidas da espessura muscular (EM), comprimento do fascículo (CF) e ângulo de penação do fascículo (AP) através do método que identifica marcações anatômicas internas. A EM também foi medida através de distâncias predeterminadas de 2 cm proximal, 6 cm proximal e 2 cm distal. A ANOVA de uma via com medidas repetidas não identificou diferença significativa para todas as variáveis mensuradas, o erro típico de medida em centímetros (cm) ou graus (º), o coeficiente de variação em percentual (%) e o coeficiente de correlação intraclasse foram respectivamente: EM = 0,07 cm, 2,93%, 0,964; CF = 0,31 cm, 2,89%, 0,947; AP = 0,92º; 4,08%; 0,942; EM 2 cm proximal = 0,10 cm, 3,77%, 0,910; EM 6 cm proximal = 0,27 cm, 9,66%, 0,576; EM 2 cm distal = 0,35 cm, 19,76%, 0,564. EM, CF e AP apresentaram alta confiabilidade e baixo erro de medida. As marcações anatômicas internas demonstraram ser mais confiáveis e apresentam menores erros de medida quando comparados ao método de distâncias predeterminadas.Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil2021-03-10info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion"Avaliado por Pares",Reliability; Measurement errorAvaliado por Paresapplication/pdfhttps://periodicos.ufsc.br/index.php/rbcdh/article/view/7640210.1590/1980-0037.2021v23e76402Brazilian Journal of Kinanthropometry and Human Performance; Vol. 23 (2021); e76402Revista Brasileira de Cineantropometria e Desempenho Humano; v. 23 (2021); e764021980-00371415-8426reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)instname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCenghttps://periodicos.ufsc.br/index.php/rbcdh/article/view/76402/45741Copyright (c) 2021 Revista Brasileira de Cineantropometria e Desempenho Humanoinfo:eu-repo/semantics/openAccessSoares, André Luiz ConvenienteNogueira, Fernando dos SantosGomes, Paulo Sergio Chagas2021-03-10T13:31:04Zoai:periodicos.ufsc.br:article/76402Revistahttps://periodicos.ufsc.br/index.php/rbcdh/PUBhttps://periodicos.ufsc.br/index.php/rbcdh/oairbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br1980-00371415-8426opendoar:2021-03-10T13:31:04Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)false
dc.title.none.fl_str_mv Assessment methods of vastus lateralis muscle architecture using panoramic ultrasound: a new approach, test-retest reliability and measurement error
Métodos de avaliação da arquitetura do músculo vasto lateral usando ultrassonografia panorâmica: nova abordagem, confiabilidade teste-reteste e erro da medida
title Assessment methods of vastus lateralis muscle architecture using panoramic ultrasound: a new approach, test-retest reliability and measurement error
spellingShingle Assessment methods of vastus lateralis muscle architecture using panoramic ultrasound: a new approach, test-retest reliability and measurement error
Soares, André Luiz Conveniente
title_short Assessment methods of vastus lateralis muscle architecture using panoramic ultrasound: a new approach, test-retest reliability and measurement error
title_full Assessment methods of vastus lateralis muscle architecture using panoramic ultrasound: a new approach, test-retest reliability and measurement error
title_fullStr Assessment methods of vastus lateralis muscle architecture using panoramic ultrasound: a new approach, test-retest reliability and measurement error
title_full_unstemmed Assessment methods of vastus lateralis muscle architecture using panoramic ultrasound: a new approach, test-retest reliability and measurement error
title_sort Assessment methods of vastus lateralis muscle architecture using panoramic ultrasound: a new approach, test-retest reliability and measurement error
author Soares, André Luiz Conveniente
author_facet Soares, André Luiz Conveniente
Nogueira, Fernando dos Santos
Gomes, Paulo Sergio Chagas
author_role author
author2 Nogueira, Fernando dos Santos
Gomes, Paulo Sergio Chagas
author2_role author
author
dc.contributor.author.fl_str_mv Soares, André Luiz Conveniente
Nogueira, Fernando dos Santos
Gomes, Paulo Sergio Chagas
description Extended-field-of-view ultrasonography is a valid alternative to determine the dimensions of the skeletal striated muscle; however, some factors may influence the final measurement. The aim of this study was to determine the test-retest reliability and measurement error of  vastus lateralis muscle architecture variables through internal anatomical landmarks and to compare three fixed determined points using extended-field-of-view ultrasonography. Twelve young (24 ± 6 years) adult university male students participated in the study. Images were obtained through extended-field-of-view ultrasonography of the vastus lateralis muscle. Measurements were made for muscle thickness (MT), fascicle length (FL), and fascicle pennation angle (FA) using a method that identifies internal anatomical landmarks. MT was also measured at predetermined distances of 2 cm proximal, 6 cm proximal, and 2 cm distal. One-way ANOVA with repeated measures did not identify any test-retest significant differences for all variables measured. Typical measurement error in centimeters (cm) or degrees (º), coefficient of variation in percentage (%) and intraclass correlation coefficient were MT = 0.07 cm, 2.93%, 0.964; FL = 0.31 cm, 2.89%, 0.947; FA = 0.92°, 4.08%, 0.942; MT 2 cm proximal = 0.10 cm, 3.77%, 0.910; MT 6 cm proximal = 0.27 cm, 9.66%, 0.576; MT 2 cm distal = 0.35 cm, 19.76%, 0.564. MT, FL and FA showed high reliability and low measurement error. Internal anatomical landmarks proved to be more reliable and presented smaller measurement errors when compared to the predetermined distances method.
publishDate 2021
dc.date.none.fl_str_mv 2021-03-10
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
"Avaliado por Pares",
Reliability; Measurement error
Avaliado por Pares
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/76402
10.1590/1980-0037.2021v23e76402
url https://periodicos.ufsc.br/index.php/rbcdh/article/view/76402
identifier_str_mv 10.1590/1980-0037.2021v23e76402
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://periodicos.ufsc.br/index.php/rbcdh/article/view/76402/45741
dc.rights.driver.fl_str_mv Copyright (c) 2021 Revista Brasileira de Cineantropometria e Desempenho Humano
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2021 Revista Brasileira de Cineantropometria e Desempenho Humano
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
publisher.none.fl_str_mv Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
dc.source.none.fl_str_mv Brazilian Journal of Kinanthropometry and Human Performance; Vol. 23 (2021); e76402
Revista Brasileira de Cineantropometria e Desempenho Humano; v. 23 (2021); e76402
1980-0037
1415-8426
reponame:Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
collection Revista Brasileira de Cineantropometria & Desempenho Humano (Online)
repository.name.fl_str_mv Revista Brasileira de Cineantropometria & Desempenho Humano (Online) - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv rbcdh@contato.ufsc.br || portaldeperiodicos.bu@contato.ufsc.br
_version_ 1789435126043639808